• 제목/요약/키워드: Renewable Energy Systems

검색결과 904건 처리시간 0.031초

Gas Hydrate Systems at Hydrate Ridge;Results from ODP Leg 204

  • Lee, Young-Joo;Kim, Ji-Hoon;Ryu, Byong-Jae
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.531-533
    • /
    • 2007
  • We report and discuss molecular and isotopic properties of hydrate-bound gases from 55 samples and void gases from 494 samples collected during Ocean Drilling Program (ODP) Leg 204 at Hydrate Ridge offshore Oregon. Gas hydrates appear to crystallize in sediments from two end-member gas sources (deep allochthonous and in situ) as mixtures of different proportions. In an area of high gas flux at the Southern Summit of the ridge (Sites 1248-1250), shallow (0-40 meters below the seafloor (mbsf)) gas hydrates are composed of mainly allochthonous mixed microbial and thermogenic methane and a small portion of thermogenic C2+ gases, which migrated vertically and laterally from as deep as 2-2.5 km depths. In contrast, deep (50-105 mbsf) gas hydrates at the Southern Summit (Sites 1248 and 1250) and on the flanks of the ridge (Sites 1244-1247) crystallize mainly from microbial methane and ethane generated dominantly in situ. A small contribution of allochthonous gas may also be present at sites where geologic and tectonic settings favor vertical gas migration from greater depth (e.g., Site 1244).

  • PDF

차량용 스택 고출력 내구성능 (High Durability of Stack for Automobile)

  • 김영민;이종현;윤종진;조장호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.557-560
    • /
    • 2007
  • The durability of 80 kW class stack module was tested in hydrogen recirculation and non-recirculation systems with the condition of 300Amps (constant current mode) and hydrogen pulse purging (10 seconds close/0.8 seconds open). A localized membrane failure in the interfacial area between membrane and sub-gasket, carbon corrosion in cathode electrode, and Pt dissolution/extraction have been found through the post mortem analysis such as CV, Impedance, SEM, and so on. The main reason of these mechanisms will be discussed in this study.

  • PDF

금속 수소화물을 이용한 수소공급시스템 (Hydrogen Supplying System using Metal Hydride)

  • 배상철;승전정문
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.13-19
    • /
    • 2007
  • To find out the optimum design of hydrogen storage and supply tank using Metal Hydride (briefly MH) and to make clear the performance characteristics under various conditions are our research purpose. In order to use the low-temperature exhaust heat, $LaNi_{4.7}Al_{0.3}$ which operates under the low pressure of 1 MPa is chosen, and we measure the basic properties, namely density, specific heat, PCT(Pressure-Concentration-Temperature) characteristics, and effective thermal conductivity. Then, a numerical calculation model of hydrogen storage using MH alloy is suggested and this thermal diffusion equation of model is solved by the backward difference method. This calculation results are compared with the experimental results of the systems which installed 1kg MH alloy and, it is found out that our calculation model can well predict the experimental results. By the experimental using MH alloy, it is recognized that the hydrogen flow rate can control by the step adjustment of brine temperature.

  • PDF

공기극 채널 형상이 직접 메탄올 연료전지의 성능에 미치는 영향 (Effect of air flow channel configuration on performance of direct methanol fuel cells.)

  • 황용신;최훈;차석원;이대영;김서영
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.137-140
    • /
    • 2007
  • We consider the optimum air flow channel design for DMFC's in the present study. The effect of pressure drop across the inlet and outlet of a stack on the performance of a DMFC is the optimization of such geometric parameters is crucial to minimize the parasitic power usage by the auxiliary devices such as fuel pumps and blowers. In this paper, we present how the pressure drop control can optimize the driving point of a DMFC stack. Further, we show how the optimal fuel utilization ratio can be achieved, not degrading the performance of DMFC stacks. Overall, we discuss how the flow channel design affects the selection of balance of plant(BOP) components, the design of DMFC systems and the system efficiency.

  • PDF

태양열발전 제어시스템 (A Control System for Solar Thermal Power Plant)

  • 박영칠
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 춘계학술대회
    • /
    • pp.693-697
    • /
    • 2007
  • A control system for solar thermal power plant is the control system to coordinate the whole system's operation, including management of distributed control systems, process control for optimal operation of total system, monitoring system operating conditions and doing administrative functions. This work, as a progress report, presents the results obtained so far in building a control system for the 1MW solar thermal power plant. To make the control system, we first defined the control system's hierarchy and classified the role of each layer. Then, as the first stage of making control system, we designed and developed the sun tracking control system for heliostat.

  • PDF

2MW급 풍력발전시스템용 이중여자 발전기 설계 (The Design of Doubly-fed Induction Generator for 2MW wind power system)

  • 조동혁;황상연;조성호;이인우;이승구
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.257-260
    • /
    • 2006
  • This paper presents a design approach for wind power generator. Among several different generator systems, doubly-fed induction generator(DFIG) is selected for Hyosung 2MW wind turbine system from the view of cost and weight. The time step finite element method is applied to analyze the performance of DFIG, and design of experiment(DOE) is used as an optimization method.

  • PDF

에너지 저장 시스템을 위한 비절연 양방향 ZVT DC-DC 컨버터 (Nonisolated Bidirectional ZVT DC-DC Converter for an Energy Storage System)

  • 한기태;임창순;김래영;현동석
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2012년도 추계학술대회 논문집
    • /
    • pp.50-51
    • /
    • 2012
  • The paper presents a non-isolated bidirectional DC-DC converter for use in renewable power generation, battery, electric vehicles (EV) and small scale DC-UPS systems. In the propose design, the conventional interleaved operation of two-inductor boost structure is modified to accommodate bidirectional operation, and zero-voltage-transition (ZVT) is applied, where both the switch and the rectifier diode achieve soft condition without increasing their voltage and current stresses. The proposed converter has the merits of simple circuitry, reduced size, low cost and high efficiency. The operation principle of the converter is analyzed and verified. Also, simulation results of the proposed bidirectional dc-dc converter is shown.

  • PDF

수상/해상 태양광발전 시스템의 패키징 기술개발 동향 (Trend of Packaging Technology for Floating Photovoltaics)

  • 최수빈;김명훈;김광석
    • 마이크로전자및패키징학회지
    • /
    • 제27권3호
    • /
    • pp.21-27
    • /
    • 2020
  • The importance of floating photovoltaic systems has recently been emerging to address some issues arising from the installation of conventional ground-mounted photovoltaics. Floating photovoltaics have a few advantages such as cutting down land usage, reducing water evaporation or creating algae. Though there is still necessity to supplement with technical issues: mechanical stability, reliability and long-term durability of floaters and modules. In this paper, we focus the current level of packaging development and introduce research trends that could be applied to next-generation floating photovoltaics.

다중현상 유동 해석 및 설계를 위한 융복합 프레임웍 개발 (DEVELOPMENT OF A HYBRID CFD FRAMEDWORK FOR MULTI-PHENOMENA FLOW ANALYSIS AND DESIGN)

  • 허남건
    • 한국전산유체공학회:학술대회논문집
    • /
    • 한국전산유체공학회 2010년 춘계학술대회논문집
    • /
    • pp.517-523
    • /
    • 2010
  • Recently, the rapid evolution of computational fluid dynamics (CFD) has enabled its key role in industries and predictive sciences. From diverse research disciplines, however, are there strong needs for integrated analytical tools for multi-phenomena beyond simple flow simulation. Based on the concurrent simulation of multi-dynamics, multi-phenomena beyond simple flow simulation. Based on the concurrent simulation of multi-dynamics, multi-physics and multi-scale phenomena, the multi-phenomena CFD technology enables us to perform the flow simulation for integrated and complex systems. From the multi-phenomena CFD analysis, the high-precision analytical and predictive capacity can enhance the fast development of industrial technologies. It is also expected to further enhance the applicability of the simulation technique to medical and bio technology, new and renewable energy, nanotechnology, and scientific computing, among others.

  • PDF

Modified TOUGHREACT를 이용한 지중 열교환기 내 순환 유체의 온도 분포 추정 (A Study to Calculate Inlet Fluid Temperature of the Borehole Heat Exchanger (BHE) using Modified TOUGHREACT)

  • 김성균;배광옥;이강근;심병완;송윤호
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2007년도 추계학술대회 논문집
    • /
    • pp.477-480
    • /
    • 2007
  • Inlet fluid temperature of the BRE in the geothermal heat pump system depends on heat exchange rate between the refrigerant of the heat pump and the leaving fluid from the BRE. Because the outlet fluid temperature of the BHE varies with time, inlet fluid temperature has to vary with time. In this study, the module to calculate inlet fluid temperature is developed, which can consider the time-varying outlet fluid temperature and the heat exchange capacity of the heat pump. It is assumed that heat loss or gain of the leaving fluid from outlet to inlet of the BHE is negligible, except when the fluid contacts with the refrigerant of the heat pump. This module is combined with TOUGHREACT, a widely accepted three-dimensional numerical simulator for heat and water flow and geochemical reactions in geothermal systems and is applied to data analyses of the thermal response test.

  • PDF