• 제목/요약/키워드: Removal device

검색결과 413건 처리시간 0.028초

Two-Phase Magnet in the Co/Co2MnSn System

  • Kim, Tae-Wan;Yim, Hye-In;Lee, Hyun-Yong;Lee, Kyoung-Il
    • Journal of Magnetics
    • /
    • 제16권1호
    • /
    • pp.10-14
    • /
    • 2011
  • This study reports on Co/$Co_2$MnSn two-phase magnets. The Co/$Co_2$MnSn two-phase magnet has Co precipitates in a $Co_2MnSn$ Heusler alloy matrix, in which the two phases are exchange-coupled at the phase boundary. The as-casted Co/$Co_2$MnSn system, which has Co-Mn solid solution precipitates in a $Co_2$MnSn Heusler alloy matrix, showed that the Co solid solution precipitates are crystallographically coherent and there is exchange coupling at the phase boundary. To form pure Co precipitates by removal of Mn solute atoms in Co-Mn solid solution, annealing was carried out 48 hours at $870^{\circ}C$. After annealing, the low $T_c$ and low magnetization phase of the Co-Mn solid solution became a high $T_c$ and high magnetization phase of hexagonal Co.

멀티빔 음향측심기를 이용한 하상지형 관측에 관한 연구: 백마강 레저파크를 중심으로 (A Study on the Observations of Riverbed Topography Using Multibeam Echo-Sounder Near Baeckma River Leisure Park)

  • 윤공현;양주경
    • 한국산업융합학회 논문집
    • /
    • 제24권1호
    • /
    • pp.61-67
    • /
    • 2021
  • With the recent development of bathemetry technology, the hydrographic surveying method has been changed from single beam depth device use to multi beam acoustic sounding technology. Also, various studies have been reported to obtain high accuracy and precision in the process of river bed topographic data. Especially south korea is geographically on three sides of the sea and the river topography is very developed. To build information about the underwater, and riverbed status, the public investigations has been continuously progressed. In this study, We investigasted the riverbed topography near Baeckma river leisure park. for this purpose, In this study, as the first preliminary survey, location of navigational dangerous objects and reefs and the dangerous areas are identified. Also, ground control points is selected for the optimal GPS surveying. Secondary, through test surveying the Gain, TVG, and pulse length are determined. In addition, the investigation of dangerous objects for navigation is also conducted. As the last step, the error analysis are conducted for the acquired data, and this process involves the removal and adjustments of errors. This section includes the analysis of tide level and navigational contributions, and finally generates a submarine topographic map.

Recovery of ammonia from wastewater by liquid-liquid membrane contactor: A review

  • Jang, Yoonmi;Lee, Wooram;Park, Jaebeom;Choi, Yongju
    • Membrane and Water Treatment
    • /
    • 제13권3호
    • /
    • pp.147-166
    • /
    • 2022
  • Liquid-liquid membrane contactor (LLMC), a device that exchanges dissolved gas molecules between the two sides of a hydrophobic membrane through membrane pores, can be employed to extract ammoniacal nitrogen from a feed solution, which is transported across the membrane and accumulated in a stripping solution. This LLMC process offers the promise of improving the sustainability of the global nitrogen cycle by cost-effectively recovering ammonia from wastewater. Despite recent technological advances in LLMC processes, a comprehensive review of their feasibility for ammonia recovery is rarely found in the literature. Our paper aims to close this knowledge gap, and in addition to analyze the challenges and provide potential solutions for improvement. We begin with discussions on the operational principles of the LLMC process for ammonia recovery and membrane types and membrane configurations commonly used in the process. We then assess the performance of the process by reviewing publications that demonstrate its practical application. Challenges involved in the implementation of the LLMC process, such as membrane fouling, membrane wetting, and chemical requirements, are presented, along with discussions on potential strategies to address each. These strategies, including membrane modification, hybrid process design, and process optimization based on cost-benefit analysis, guide the reader to identify key areas of future research and development.

Effectiveness of a Hockey-Stick Probe to Localize a Catheter Fragment in a Dog

  • Kim, Kitae;Oh, Dayoung;Shin, Dongmin;Yoon, Junghee
    • 한국임상수의학회지
    • /
    • 제39권4호
    • /
    • pp.173-176
    • /
    • 2022
  • Intravenous catheterization is a common procedure in human and veterinary medicine. Occasionally, a catheter might break within the blood vessel, and the fragment may cause embolization, infections, or other severe complications, and therefore must be removed promptly. For a successful and low-risk removal, the fragment should be localized accurately; however, ultrasound may be challenging to perform on small dogs due to inadequate probes. We report the case of a 2-year-old, 2.6 kg, intact female toy poodle that presented to the veterinary medical center owing to a recent onion intake; the owner requested to induce emesis. A 24 gauge peripheral intravenous catheter was inserted into the cephalic vein prior to the emetic injection. When the clinician removed the catheter, a device breakage was observed. A tourniquet was applied immediately proximal to the elbow. Ultrasonography was performed with a high-frequency small-footprint linear array transducer, also called a hockey-stick probe, to localize the fragment. An additional ultrasound was performed before surgery to confirm the location of the catheter piece, which migrated 5 cm proximally. Afterward, a surgical intervention allowed us to retrieve the fragment. This report highlights the effectiveness of a hockey-stick probe to determine the location of a catheter fragment in small breed dogs.

정맥주입요법 간호실무지침 수용개작 (Adaptation of Intravenous Infusion Nursing Practice Guideline)

  • 구미옥;조용애;조명숙;은영;정재심;정인숙;이영근;김미경;김은현;김지혜;이선희;김현림;윤희숙
    • 임상간호연구
    • /
    • 제19권1호
    • /
    • pp.128-142
    • /
    • 2013
  • Purpose: This study was conducted to adapt the previously developed intravenous infusion guidelines with good quality for development of the evidence-based intravenous infusion nursing practice guideline in Korea. Methods: Guideline adaptation process was conducted according to guideline adaptation manual version 2.0 developed by NECA (Kim, Kim et al., 2011) which consisted of three main phases, 9 modules including a total of 24 steps. Results: Adapted intravenous infusion nursing practice guideline was consisted of 19 domains and 180 recommendations. The domains and number of recommendations in each domain were: general guide, 4; assessment, 1; vascular access device selection, 4;site selection, 14;site preparation, 5;site care, 29; maintaining patency, 11; blood sampling via vascular access, 4; vascular access device exchange and removal, 9; add-on device selection, 27; infusion related complications, 63; education, 7; and documentation and report, 2. There were 11.9% of A, 28.4% of B, 58.7% of C in grade of recommendations. Conclusion: Adapted intravenous infusion nursing practice guideline is expected to contribute providing an evidence based practice guides for intravenous infusion. The guideline is recommended to be disseminated to nurses nationwide to improve the efficiency of intravenous infusion practice.

안드로이드 환경의 OAuth 프로토콜을 이용한 원격지 데이터 수집 방법 연구 (Study on Remote Data Acquisition Methods Using OAuth Protocol of Android Operating System)

  • 남기훈;공성현;석병진;이창훈
    • 정보보호학회논문지
    • /
    • 제28권1호
    • /
    • pp.111-122
    • /
    • 2018
  • 안드로이드 운영체제의 서드파티 애플리케이션들은 사용자의 계정 및 개인정보에 대한 접근 권한을 획득하기 위해 OAuth 프로토콜을 이용하여 계정 정보 제공자들로부터 사용자의 크리덴셜 및 사용자의 자원에 접근할 수 있는 권한을 내포하는 접근 토큰을 전달받는다. 이러한 크리덴셜 및 토큰 정보는 안드로이드 운영체제가 제공하는 OAuth 관련 데이터 관리 방식에 의해 기기 내부에 저장되는데, 이 정보가 유출될 경우 공격자는 유출된 크리덴셜 및 토큰 정보를 이용하여 사용자의 계정에 대한 자유로운 로그인 및 데이터 접근이 가능하다. 이러한 특징은 디지털 포렌식 수사관이 증거 데이터를 수집하는 관점에서 피압수자가 사용하는 서비스의 원격지 서버로부터 직접 데이터를 수집하는 것을 가능하게 한다. 원격지에서 수집되는 증거 데이터는 2차적인 영장발부의 토대로 작용함으로써 수집한 디지털 증거의 증거능력을 확보할 수 있기 때문에 피압수자가 안드로이드 기기에서 애플리케이션 삭제 등의 증거 인멸을 시도한 경우 매우 중요한 증거가 될 수 있다. 본 논문에서는 다양한 안드로이드 운영체제 및 기기 환경에서 OAuth 토큰의 관리 현황을 분석하고, 이를 이용하여 다양한 서드파티 애플리케이션의 데이터를 수집하는 방법을 소개한다. 이를 통해 디지털 포렌식 관점에서 피압수자가 사용하는 서비스의 원격지 데이터를 수집함으로써 증거 수집의 영역을 확장할 수 있는 방안을 제안한다.

수세탈취시스템을 이용한 축산악취저감에 관한 연구 (A Study on Livestock Odor Reduction Using Water Washing System)

  • 전경호;최동윤;송준익;박규현;김재환;곽정훈;강희설;정종원
    • 한국축산시설환경학회지
    • /
    • 제16권1호
    • /
    • pp.21-28
    • /
    • 2010
  • 수세탈취식을 이용한 축산악취저감에 관한 연구를 수행한 결과 다음과 같은 결과를 얻을 수 있었다. 개발된 용해도 측정장치를 이용하여 악취가스의 용해특성을 조사한 결과, 황화수소의 경우에는 용매와의 접촉 시간과 관계없이 매우 낮은 것을 알 수 있었다. 이에 비해, 메틸메르캅탄의 경우에는 물과의 접촉시간을 증가시킴에 따라 용해도도 함께 증가하는 것을 알 수 있었다. 이밖에 다른 황화합물인 디메틸설파이드, 디메탈디설파이드, 암모니아의 경우에는 매우 용해도가 높은 특성을 가지고 있었다. 따라서, 축사의 측벽에 수세탈취식 악취저감장치를 부착하여 사용할 경우에는 가능한 물과 환기가스의 접촉시간을 길게 유지시켜 주는 것이 악취저감성능을 향상 시킬 수 있는 것을 알 수 있었다. 그러나, 혐기성 상태에서 발생하기 쉬운 황화수소와 같은 경우에는 수세탈취식을 이용할 경우, 가스의 물에 대한 용해도가 낮기 때문에 높은 악취저감 효율을 기대하기는 어려울 것을 예측할 수 있었다. 그러나, 실제 벤치스케일을 제작하여 실험한 결과 포든 가스에서 용해도 측정실험보다 높은 저감효과를 얻을 수 있었다. 또한, 수세탈취 시스템에서의 분진 저감율이 93%으로 나타나, 악취저감 효과뿐만 아니라 분진발생량도 크게 줄일수 있는 것으로 나타났다.

광량에 따른 실내식물 디펜바키아와 스파티필럼의 미세먼지 제거능 (Particulate Matter Removal of Indoor Plants, Dieffenbachia amoena 'Marianne' and Spathiphyllum spp. according to Light Intensity)

  • 권계정;박봉주
    • 한국조경학회지
    • /
    • 제46권2호
    • /
    • pp.62-68
    • /
    • 2018
  • 본 연구는 실내공간을 모형화한 아크릴챔버($600{\times}800{\times}1,200mm$, $L{\times}W{\times}H$)와 공기정화 장치인 그린바이오필터($495{\times}495{\times}1,000mm$, $L{\times}W{\times}H$)를 아크릴로 제작하여 광량 0, 30, $60{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}PPFD$의 3수준에 따른 디펜바키아와 스파티필럼의 미세먼지(PM10) 및 초미세먼지(PM1) 제거능과 두식물의 광합성율, 기공전도도, 기공수를 비교하였다. PM10이 $1{\mu}g$이 될 때까지 걸리는 시간에 있어서 디펜바키아는 광의 유무에 따른 차이가 유의하게 나타났으며, 30과 $60{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}PPFD$에서는 유의적인 차이가 없었다. 스파티필럼은 0과 $30{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}PPFD$에서는 유의적인 차이가 없었으나, $60{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}PPFD$에서 유의적인 차이를 보였다. 90분 경과 후, $60{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}PPFD$에서 스파티필럼의 PM1, PM10 잔존량이 가장 적었으며, 이때 이산화탄소 잔존량도 가장 낮은 것으로 나타났다. 스파티필럼은 $0{\mu}mol{\cdot}m^{-2}{\cdot}s^{-1}PPFD$에서도 PM1, PM10 잔존량이 디펜바키아보다 낮은 것으로 나타났다. 두 식물 모두 광량이 높을수록 광합성율이 높게 나타났으며, 기공전도도는 유의적인 차이가 없었다. 스파티필럼은 디펜바키아보다 광합성율과 기공전도가 높았고, 기공수가 많았으며, 잎의 앞 뒷면 모두에서 기공이 관찰되었다. 이러한 식물적 특성으로 인하여 같은 광량에서 스파티필럼의 공기정화 효과가 디펜바키아보다 더 좋았던 것으로 판단된다. 따라서 효과적인 실내 미세먼지 제거를 위해서는 실내광량에 따른 식물의 광합성율과 기공수, 기공의 배치형태 등 식물 각각의 특성을 고려해야 할 것으로 판단된다.

중.소형 폐기물 소각시설에서 배출되는 수은, 납, 비소, 셀렌 배출특성 (A Characteristics of Hg, Pb, As and Se Emitted from Small and Medium Size Waste Incinerator Stacks)

  • 이한국;문부식;이동훈
    • 대한환경공학회지
    • /
    • 제27권11호
    • /
    • pp.1205-1214
    • /
    • 2005
  • 본 논문은 중소형 규모의 도시고형 폐기물소각시설 배가스의 수은, 납, 비소, 셀렌과 같은 휘발성중금속의 방출특성을 조사하는데 있다. 대체로, 소형 도시고형 폐기물소각시설에서 배출되는 수은, 납, 비소, 셀렌이 중형 소각시설에서 배출되는 것 보다 높게 나타났다. 이는 중형소각시설에 비하여 소형소각시설의 빈약한 대기오염제어장치의 가동과 높은 배가스 온도에 기인하는 것으로 판단된다. 중소형 소각시설의 배가스 온도는 2개의 온도그룹으로 나누어지는 것을 확인할 수 있다. 첫 번째 온도그룹은 대략 $100^{\circ}C$이고, 두 번째 온도그룹은 $400{\sim}700^{\circ}C$ 정도였다. 2번째 그룹에서의 배가스 중 수은, 납, 비소, 셀렌은 각각 $70.43\;{\mu}g/Sm^3$, $0.94\;{\mu}g/Sm^3$, $9.83\;{\mu}g/Sm^3$, $5.05\;{\mu}g/Sm^3$였다. 첫 번째 온도그룹에서 배가스의 수은, 납, 비소 셀렌은 두 번째 온도그룹의 것보다 낮은 특징을 가지고 있다. 한편, 중형소각시설에서의 수은제거효율은 $55.16{\sim}95.89%$로 나타났다. 이러한 수은의 감소는 폐열보일러의 온도저감이 기여를 하고 있었다. 상기 결과로, 중소형 소각시설에서 휘발성 중금속 제어에 중요한 역할을 하는 것은 배가스의 온도가 큰 역할을 한다. 따라서, 휘발성 중금속의 제거효율을 개선하기 위해서는, 냉각시스템의 온도가 제어되고 대기오염제어장치가 잘 운영되어야 한다.

미세기포 세척장비를 이용한 도로시설물 염화칼슘의 제거 (Removal of calcium chloride in road structure using ultra-fine bubble washing machine)

  • 박일건;이준형;박형준;김현진;김흥래;조일형
    • 한국응용과학기술학회지
    • /
    • 제36권4호
    • /
    • pp.1281-1289
    • /
    • 2019
  • 본 연구는 도로시설물의 염화칼슘 제거를 위한 미세기포 세척장비의 최적 운용조건에 대하여 성능평가를 수행하였다. 실험에 사용된 미세기포의 직경은 196.6±100.6nm에 1.36×108개/ml의 농도를 나타낸다. 세척장비의 분사장치에 대한 실험 성능결과, 100bar의 분사압력에서 100cm, 150cm 분사거리에 약 93%, 91%의 세척효율이 나타나는 것으로 확인되었다. 미세기포 생성(순환)횟수를 2-6회로 증가시킴에 따라 최소 1%에서 7%까지 염화물 제거율이 높아짐을 확인하였다. 미세기포 생성 공기유량을 4 ml/min에서 0.5 ml/min으로 낮춤에 따라 세척효율이 최대 30%까지 증가하는 것이 확인되었다. 일반 상수도와 미세기포의 세척효율은 미세기포가 일반상수도 보다 세척효율이 25% 높게 나타났다.