• 제목/요약/키워드: Removal device

검색결과 413건 처리시간 0.022초

족관절 골절 치료에 사용한 금속 내고정물 제거 수술 시 시행한 균 배양 검사의 결과 (Results of Culture Test at the Time of Removal of Metal Implants Used for Ankle Fracture Management)

  • 정형진;배서영;유재하
    • 대한족부족관절학회지
    • /
    • 제18권2호
    • /
    • pp.68-71
    • /
    • 2014
  • Purpose: The purpose of this study is to report the results of culture test at the time of removal of metal devices used for management of ankle fractures and for analysis of contributing factors. Materials and Methods: We reviewed medical records of 132 patients with lower tibia and ankle fracture who had their metal devices removed during the period from January 2010 to February 2014. Patients with clinical signs of infection were excluded. Culture test was performed by taking the granulation tissue around the metal device at the time of removal. We divided the subjects into two groups, culture positive and negative. We then performed a retrospective review of each medical record of multiple factors that might contribute to the culture results, including laboratory results, medical history, material and size of metal device, indwelling period, and whether or not it was open injury. Results: Among 132 cases, six were culture positive. Enterococcus was detected in two cases and the others were Staphylococcus. No significant difference in medical history of patients and laboratory results, including C-reactive protein level, was observed between the culture positive and negative group. Culture positive rate was 5.4% in titanium and 3.9% in stainless steel. In terms of metal size, culture positive rate was 5.1% in small plates, 6.7% in large plates, and culture negative in intramedullary nails. The average indwelling period of metal device was 61.5 weeks in the culture positive group, and 68.6 weeks in the negative group. Nine cases were open fractures and all were in the culture negative group. Conclusion: Whether or not the culture result was positive, there were no meaningful contributing factors. Presence of bacterium on the metal device could not be screened by any laboratory results or other factors.

순산소의 MBR(Membrane Bio Reactor) 공정 적용을 통한 음식물류 폐기물 혐기성소화 유출수 처리 평가 (Evaluation of pure oxygen with MBR(Membrane Bio Reactor) process for anaerobic digester effluent treatment from food waste)

  • 박세용;김문일;박성혁
    • 유기물자원화
    • /
    • 제29권3호
    • /
    • pp.5-16
    • /
    • 2021
  • 본 연구에서는 MBR 공정 내 폭기조에서 순산소 용해와 일반 공기 폭기의 효율에 대한 비교·평가를 통해 순산소의 MBR 공정 적용성에 대해 평가 하였다. 순산소 장치에 의한 유기물 및 암모니아 산화 여부에 대해 평가하였으며, 실폐수(음식물류 폐기물의 혐기성소화 유출수) 적용 과포화산소용해 효율 평가를 진행하였다. 순산소용해와 일반공기폭기 방법의 SCOD, 암모니아 제거율과 속도는 비슷하였다. 하지만, 순산소 용해에 의한 미생물 수율이 일반공기폭기법에 의한 미생물 수율보다 약 0.03 g MLSS-produced/g SCOD-removed 낮아 잉여슬러지 처리 비용이 감소될 수 있을 것이라 판단된다. 음식물류 폐기물의 혐기성 소화 유출수의 고농도 유기물 (4,000 mg/L) 및 암모니아 (1,400 mg/L)의 제거율을 순산소용해와 일반공기폭기법을 비교한 결과, 순산소 용해기가 일반공기폭기법에 비해 유기물 제거율이 약 13% 가량 더 높게 평가되었다. 또한, MLSS의 경우 일반공기폭기법이 순산소장치에 비해 0.3배가량 높았다. 이는, 순산소장치의 경우 폭기조 내에 용존산소가 충분히 유지, 공급되기 때문에 슬러지 자산화가 고도로 진행된 결과로 판단되었다. 따라서, 고농도 유기물을 함유한 폐수 처리를 위한 방법으로는 기존에 많이 사용되었던 일반공기폭기법보다 순산소장치를 활용하는 것이 경제적인 면에서 더 유리할 것으로 판단되었다.

3축 MEMS 가속도 센서를 이용한 걸음 수 측정을 위한 중력 제거 및 백터 전환 알고리즘 (Gravity Removal and Vector Rotation Algorithm for Step counting using a 3-axis MEMS accelerometer)

  • 김승영;권구인
    • 한국컴퓨터정보학회논문지
    • /
    • 제19권5호
    • /
    • pp.43-52
    • /
    • 2014
  • 최근, 다양한 형태의 웨어러블 컴퓨팅 디바이스와 이에 따른 응용 프로그램이 개발되고 있으며, 이들 중에서 헬스 케어의 한 영역으로 웨어러블 컴퓨팅 디바이스를 이용하여 개인의 운동량은 측정하는 다양한 연구가 진행되고 있다. 본 논문에서는 가장 기초적인 운동인 걸음걸이 측정 알고리즘으로 중력 제거 및 백터 회전(Gravity Removal and Vector Rotation) 알고리즘을 제안하고, 이를 위한 실험으로 보행 또는 주행 중인 개인의 다양한 위치에 부착한 웨어러블 디바이스에 장착된 3축 MEMS 가속도 센서로부터 획득된 가속도 값을GRVR 알고리즘을 이용하여 걸음 수를 측정한다. GRVR은 가속도 센서로 획득된 3축 가속도 값으로 부터 중력에 의한 가속도 분은 저대역 필터를 이용하여 제거 하고, 이 후 각각의 가속도 값에서 직류 성분 제거 및 센서 축 회전 보상인 GRVR 알고리즘으로 보행 혹은 주행 중에 순수하게 걸음걸이에 의하여 발생하는 가속도 변화분 만을 추출한다. 실험 결과로 웨어러블 디바이스를 개인의 허리 중앙 혹은 우측에 부착한 경우 GRVR 알고리즘을 이용한 걸음 수 측정은 99.4%의 정확도, 또한 손목에 부착한 경우 상용 3축 가속도 만보계의 83%보다 정확한 91.1%의 정확도를 확인하였다.

고속도로 현장별 비점오염 저감시설 선정방안 연구 (A Study for selecting the Highway Sites' Best Management Practice for Nonpoint Source Pollution)

  • 이용복;최상일;박계수;성일종;정선국
    • 환경영향평가
    • /
    • 제20권6호
    • /
    • pp.857-866
    • /
    • 2011
  • This research categorized EIA target highways into following three types in order to minimize non-point source pollution from highway runoff. 1. Big drainage basin. 2. Small drainage basin. 3. Bridge section. The Natural, Filter and Swirl-Type devices were evaluated in terms of removal efficiency of TSS, BOD, COD, T-N, T-P, compatibility of site selection, economic feasibility, and maintenance convenience through which the final BMP was selected. According to the removal efficiency result, the area of Big and Small Drainage basin and bridge section had higher removal efficiency with natural facility than that of the Filter or Swirl-Type device. To make appropriate selection of highways'BMP for non-point source pollution, this study will aim to contribute to building more environmentally friendly highways by proposing the selection process that is made of 5 stages. 1. Selecting the target drainage basin. 2. Selecting the land for the mitigation facility. 3. Analysing the ease of maintenance. 4. Technically evaluating each installation. 5. Evaluating the effective implementation methods.

통합형 오일 정제 시스템의 개발 (Development of an Integrated Oil Purification System)

  • 홍성호;이경희;정남화
    • Tribology and Lubricants
    • /
    • 제38권4호
    • /
    • pp.121-127
    • /
    • 2022
  • This study presents the development of an integrated oil purification system consisting of moisture removal, oil flushing, and oil filtering devices. In this system, the oil flushing device is combined with a micro-bubble generator. Oil purification is necessary for ensuring the high performance of the lubricant through the efficient removal of contaminants and thus enables good maintenance of mechanical systems. The developed purification system removes moisture, varnish, and solid particles. Moreover, during oil purification, the oil flushing device separates foreign materials and contaminants remaining in the lubricating oil piping or mechanical systems. The microbubble generator, which is combined with the oil flushing device, can separate harmful contaminants, such as sludge, wear particles, and rust, from piping or lubrication systems through the cavitation effect. Moisture is removed using a double high-vacuum chamber, while sludge and varnish are removed via electro-absorption using a high-voltage generator. Additionally, the total maintenance cost of the system is reduced through the use of domestically fabricated cartridge filters composed of glass fiber and cellulose. The heater, which maintains the temperature of the lubricant at 60℃, can process 41,000 L of lubricant simultaneously. Multiple tests confirmed that the proposed integrated purification system exhibits good performance in oil flushing and removal of water and varnish.

미세먼지 포집장치 개발을 위한 관성충돌 프리필터 유동 전산해석 (CFD Analysis of the Inertial Impaction Pre-Filter for a Particulate Matter Collecting Device)

  • 경대승;황대성
    • 토지주택연구
    • /
    • 제10권2호
    • /
    • pp.53-58
    • /
    • 2019
  • Particulate matter (PM) is designated as a group 1 carcinogen by the International Agency for Research on Cancer (IARC) of the World Health Organization (WHO). In South Korea, the health threat caused by PM is the most serious level internationally. Therefore, in order to solve the urban PM problem, it is important to develop the technology that can control PM efficiently. In this study, CFD(Computational Fluid Dynamics) simulation was performed for PM pre-filter (type 1-3 with different PM collecting room) to develop a high-efficiency PM collecting device. The complex flow field and the local flow phenomenon inside the PM collecting device were understood with CFD simulation by changing the shape and size of the pre-filter. The PM removal performance can be described with flow rate through the device and PM removal efficiency. The type-1 pre-filter with 5x5 size collecting room was confirmed to have the highest efficiency. Based on the analysis results, the optimal type of pre-filter could be developed and it would be applied as an element technology included in the PM collecting device.

STI-CMP 공정 적용을 위한 연마 정지점 고찰 (A Study of End Point Detection Measurement for STI-CMP Applications)

  • 이경태;김상용;김창일;서용진;장의구
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2000년도 하계학술대회 논문집
    • /
    • pp.90-93
    • /
    • 2000
  • In this study, the rise throughput and the stability in fabrication of device can be obtained by applying of CMP process to STI structure in 0.18um semiconductor device. To employ in STI CMP, the reverse moat process has been added thus the process became complex and the defects were seriously increased. Removal rates of each thin films in STI CMP was not equal hence the devices must to be effected, that is, the damage was occured in the device dimension in the case of excessive CMP process and the nitride film was remained on the device dimension in the case of insufficient CMP process than these defects affect the device characteristics. To resolve these problems, the development of slurry for CMP with high removal rate and high selectivity between each thin films was studied then it can be prevent the reasons of many defects by reasons of many defects by simplification of process that directly apply CMP process to STI structure without the reverse moat pattern process.

  • PDF

산화막 CMP의 연마율 및 비균일도 특성 (Removal Rate and Non-Uniformity Characteristics of Oxide CMP (Chemical Mechanical polishing))

  • 정소영;박성우;박창준;이경진;김기욱;김철복;김상용;서용진
    • 한국전기전자재료학회:학술대회논문집
    • /
    • 한국전기전자재료학회 2002년도 춘계학술대회 논문집 유기절연재료 전자세라믹 방전플라즈마 일렉트렛트 및 응용기술
    • /
    • pp.223-227
    • /
    • 2002
  • As the channel length of device shrinks below $0.13{\mu}m$, CMP(chemical mechanical polishing) process got into key process for global planarization in the chip manufacturing process. The removal rate and non-uniformity of the CMP characteristics occupy an important position to CMP process control. Especially, the post-CMP thickness variation depends on the device yield as well as the stability of subsequent process. In this paper, every wafer polished two times for the improvement of oxide CMP process characteristics. Then, we discussed the removal rate and non-uniformity characteristics of post-CMP process. As a result of CMP experiment, we have obtained within-wafer non-uniformity (WIWNU) below 4 [%], and wafer-to-wafer non-uniformity (WTWNU) within 3.5 [%]. It is very good result, because the reliable non-uniformity of CMP process is within 5 [%].

  • PDF

와류형 미필터 비점오염저감장치의 개발과 실험적 검증 (Development and experimental verification of vortex typed nonfilter nonpoint source pollution reduction device)

  • 장석환;이재경;이해광;황성규
    • 한국수자원학회논문집
    • /
    • 제52권4호
    • /
    • pp.265-277
    • /
    • 2019
  • 본 연구에서는 효율적인 와류형 미필터 비점오염저감장치를 개발하고 검증하였다. 저감장치의 검증을 위해 오염물질을 이용하여 총 12개 형태(3개 강우강도${\times}$2개 상태${\times}$2개 단계)의 실험을 진행하였다. 실험은 (1) 모의유입량 산정(강우강도 2.5 mm/hr: $0.00152m^3/s$, 강우강도 3.395 mm/hr: $0.00206m^3/s$, 강우강도 6.870 mm/hr: $0.00326m^3/s$); (2) 오염물질 채취 및 투입(4개 입경 사이즈의 25%씩 혼합); (3) 오염물질 제거효율 측정으로 구성하였고, 장치 초기상태와 운영상태로 구분하여 수행되었다. 강우강도별로 분석한 결과, 모든 강우강도에서 초기상태 및 운영상태 모두 오염물질 농도가 감소하였으며, 유입수 대비 유출수 오염물질 제거효율에서도 오염물질을 환경부 기준 80% 이상 제거하는 결과를 보였다. 특히 제거효율이 시간이 지남에 따라 서서히 증가하여 약 90%를 상회하였으며, 초기상태보다 운영상태에서 오염물질 제거효율이 더 높은 것으로 나타났다. 따라서 본 연구에서 개발한 와류형 미필터 비점오염저감장치로 효율적인 비점오염원을 제거할 수 있음을 증명하였다.

STI-CMP 공정 적용을 위한 연마 정지점 고찰 (A Study of End Point Detection Measurement for STI-CMP Applications)

  • 김상용;서용진
    • 한국전기전자재료학회논문지
    • /
    • 제14권3호
    • /
    • pp.175-184
    • /
    • 2001
  • In this study, the improved throughput and stability in device fabrication could be obtained by applying CMP process to STi structue in 0.18 um semiconductor device. To employ the CMP process in STI structure, the Reverse Moat Process used to be added after STI Fill, as a result, the process became more complex and the defect were seriously increased than they had been,. Removal rate of each thin film in STI CMP was not uniform, so, the device must have been affected. That is, in case of excessive CMP, the damage on the active area was occurred, and in the case of insufficient CMP nitride remaining was happened on that area. Both of them deteriorated device characteristics. As a solution to these problems, the development of slurry having high removal rate and high oxide to nitride selectivity has been studied. The process using this slurry afford low defect levels, improved yield, and a simplified process flow. In this study, we evaluated the 'High Selectivity Slurry' to do a global planarization without reverse moat step, and also we evaluated EPD(Eend Point Detection) system with which 'in-situ end point detection' is possible.

  • PDF