• Title/Summary/Keyword: Remote meter Reading System

Search Result 46, Processing Time 0.027 seconds

Distribution Remote Management System Design and Program Development Based on ADWHM(Advanced Digital Watt-Hour Meter) (차세대 디지털 적산전력계에 기반한 배전원격관리시스템 설계 및 프로그램 개발)

  • Ha Bok-Nam;Ko Yun-Seok
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.54 no.4
    • /
    • pp.185-192
    • /
    • 2005
  • This paper proposes a DRMS(Distribution Remote Management System) which can enhance highly the economics of automatic metering system and the power quality supplied to the electric customer improving the efficiency of the meter reading, voltage management and load management work by realizing the remote meter reading, the remote voltage management and the remote load management based on the ADWHM(Advanced Digital Watt Hour Meter). The DRMS is designed so that the voltage management and load management work in remote site can be processed by collecting the voltage pattern and current pattern as well as watt hour data from all ADWHMs one time every month regularly or from special ADWHMS several time irregularly, A new on-line voltage and load management strategy based on the ADWHM is designed by analyzing the existing voltage management and load management process. Also, DRMS is designed so that watt-hour data, voltage pattern data, load pattern data and power factor data can be collected selectively according to the selection of user to assist effectively the methodology. Remote management program and database of the DRMS are implemented based on Visual C++, MFC and database library of MS. Also, DRMS is designed so as to communicate with the ADWHM using RS232C-TCP/IP converter and ADSL. The effectiveness of the remote metering function is proven by collecting and analyzing the data after ADWHMs installed in any site. The developed strategy and program also is verified through the simulation of voltage management and load management.

Design of DRMS(Distribution Remote Management System) Based on Advanced Digital Kwh-Meter (차세대 디지털 적산전력계에 기반한 배전원격관리 시스템 설계)

  • Ko, Yun-Seok;Lee, Kyung-Ho;Yun, Sang-Moon;Seo, Seong-Jin;Lim, Chul-Su;Kim, Yun-Jib
    • Proceedings of the KIEE Conference
    • /
    • 2002.07a
    • /
    • pp.241-243
    • /
    • 2002
  • This paper proposes a DRMS(Distribution Remote Management System) based on the advanced digital kwh-meter. The proposed URMS is designed so as to be able to collect the voltage management data, the load management data as well as the used kwh data from advanced kwh-meter remotelly. It makes the integrated management of distribution system possible and enhances highly the economics of the existing remote meter-reading system based on the only used kwh-data. Also it can improve highly the quality of power supplied to the electric customer by minimizing the volt age management cost and by enhancing the efficiency of load management.

  • PDF

A Study on the Design of Remote Meter Reading System Using PL (전력선을 이용한 원격 검침 시스템의 설계에 관한 연구)

  • Park, Yang-ha;Kim, In-Soo;Oh, Sang-Ki;Kim, Kwan-Ho;Kim, Yo-Hee;Moon, Hong-Suk;Park, Sei-Ung
    • Proceedings of the KIEE Conference
    • /
    • 1991.07a
    • /
    • pp.866-869
    • /
    • 1991
  • The Remote Meter Reading System has a briefly wireless method, telephone line method and power line method. Our System is composed of Power Amp., Optical Sensing, Digital, Analog, Logic and Load Control Parts. We adapted PSK modulation method by Power Line Carrier in Communication System.

  • PDF

A Study on Encryption Module for Remote Terminal Security of Smart Water-Grid Network (스마트 워터그리드 네트워크의 원격 단말기 보안을 위한 암호화 모듈에 관한 연구)

  • Park, Seung-Hwan;Park, Hyung-Mo;Kim, Chang-Bok
    • Journal of Advanced Navigation Technology
    • /
    • v.17 no.6
    • /
    • pp.712-719
    • /
    • 2013
  • This paper studies the security module for the reliable transmission of the meter reading and the control data between the remote terminals and the upper server-side in smart water grid. The proposed security module was implemented to make it attachable to the remote terminal without security function. In particular, unlike the smart grid of electric field, the low power is considered due to the use of battery power in the smart water grid, and the ARIA-GCM-128 symmetric key method is adopted taking into the account that the damp and constrictive environments by the installed meter location in the underground occur a communication obstacle on building of the large-scale network system. The encryption module of this paper was devised to ensure the safety between the reading data on the terminal and the control data from the upper server, and secure the stability of the remote meter reading system by taking protection against an arbitrary alteration or modification.

Trends for Secure Authentication of Risk-related Remote Metering System (위험 관련 원격 검침 시스템의 보안 인증 기술 동향)

  • Kim, Hyo-Jin;Kim, Hyun-Ho;Lee, Hoon-Jae
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2016.05a
    • /
    • pp.752-754
    • /
    • 2016
  • Power is compared to the overall share of energy continues to increase, so as a way for efficient demand management and value added according to the AMR system was introduced. But there is a risk in a variety of external attack, such as when you use the remote meter reading system, cyber attacks and hacking. It is considered that the measures sought, which can be used to prevent or pre safer urgent. In this paper, I want to point out the current research trends and issues of security authentication technology of remote meter reading system.

  • PDF

Implementation of the mote Image Based Metering System bridging with PCS Network (PCS망을 연동한 원격영상 검침시스템 구현)

  • Lee, Chang-Su;Na, Jong-Ray;Hwang, Jin-Kwon
    • The KIPS Transactions:PartD
    • /
    • v.10D no.6
    • /
    • pp.1041-1048
    • /
    • 2003
  • This paper implements a remote image based metering(IBM) system which capture meter image, recognizes number automatically, and send the data wirelessly through PCS data network. We use existing gas/water meter and get NTSC camera image by installing small monochrome CMOS camera on the meter closely. For remote data transfer, we use SMS (short message service) that is provided by commercial PCS network. We developed DVR(digital video recorder) for capturing meter image and character recognition algorithm. In addition, hardware and software for SMS and meter selector were developed.

Development of Intelligent AMI Sensing Technique Using ICT (기존 전력량계를 ICT 기반 지능형 AMI 센싱 장치로 변환 연구)

  • Sang-Ok Yoon
    • The Journal of the Korea institute of electronic communication sciences
    • /
    • v.18 no.1
    • /
    • pp.23-28
    • /
    • 2023
  • The installation rate of AMI(: Advanced Metering Infrastructure) capable of automatic electricity measurement is less than 43% nationwide and 10.5% in rural areas, which is very poor. Therefore, for the smart grid, automatic information recording of the watt-hour meter is required. For this purpose, it is necessary to develop a system capable of remote meter reading and use control by improving the existing watt-hour meter. In this paper, in order to enable the AMI function of the existing electricity meter, the remote meter reading and control technology of the existing electricity meter for AMI, the core of the smart grid, was developed using IoT and AI. The main research content was to recognize numbers using Tensorflow and Open-cv to convert it into a power meter sensing device for SG. We confirmed and checked the performance using the protyope system.

Development of Intelligent AMI Sensing Technique Using ICT (기존 전력량계를 ICT 기반 지능형 AMI 센싱 장치로 변환 연구)

  • Lee, Yang-weon;Ok, Youn-sang
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2022.10a
    • /
    • pp.546-549
    • /
    • 2022
  • The installation rate of AMI (advanced metering infrastructure) capable of automatic electricity measurement is less than 43% nationwide and 10.5% in rural areas, which is very poor. Therefore, for the smart grid, automatic information recording of the watt-hour meter is required. For this purpose, it is necessary to develop a system capable of remote meter reading and use control by improving the existing watt-hour meter. In this paper, in order to enable the AMI function of the existing electricity meter, the remote meter reading and control technology of the existing electricity meter for AMI, the core of the smart grid, was developed using IoT and AI. The main research content was to recognize numbers using Tensorflow and Open-cv to convert it into a power meter sensing device for SG. We confirmed and checked the performance using the protyope system.

  • PDF

Ubiquitous Network and Wireless Embedded System with Intelligent Channel Scheduling Method (지능형 채널 할당 기법의 유비쿼터스 네트워크 및 무선 임베디드 시스템)

  • Park, Hyoung-Keun
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • v.12 no.3
    • /
    • pp.1336-1340
    • /
    • 2011
  • In this paper, the efficient prevention of cross talk technique for basically avoiding the confusion problem between the overlapped ubiquitous network of the other object is developed within the same area. The intelligent unified wireless network remote meter reading system of the ubiquitous ZigBee base is developed based on this technology. Therefore, in this paper, each meter reading equipments managed the information of its own adjacent ZigBee channel. The intelligent network system steadily transmitting data a relay was developed based upon this information in each region through the flexible channel conversion technique.