• 제목/요약/키워드: Reliable Transfer

검색결과 445건 처리시간 0.028초

대리송수신자 개념을 이용한 신뢰성 있는 멀티캐스트 전송기법 (A Reliable Multicast Transfer Method Using Agent Sender & Receiver Concept)

  • 안병호;조국현
    • 한국정보처리학회논문지
    • /
    • 제6권2호
    • /
    • pp.396-407
    • /
    • 1999
  • A Multicast transfer is a critical delivery method to provide a transport service to multipeer applications, the various problems on the multicast transfer environments have been occurred from the results of current research. One of these problems is the multicast transport service issue to guarantee reliability and scalability. First, this paper presents the related research of the reliable multicast transport methods, and then proposes a new transfer architecture using the Agent Sender and Receiver Concept(ASRC) to solve a reliable multicast transfer issue. we also propose a method to apply the proposed architecture(ASRC) to the well-known sender-initiated and receiver-initiated transport protocol. In order 새 validate the proposed ASRC architecture, t도 applied sender and receiver system si compared and analyzed over the processing requirement and maximum throughput.

  • PDF

원자로 냉각재 펌프의 과도 상태의 유동 및 열전달 해석 연구 (Flow and Heat Transfer Analysis of Reactor Coolant Pump in Transient Conditions)

  • 허남건;김성원;유기풍;김승태
    • 유체기계공업학회:학술대회논문집
    • /
    • 유체기계공업학회 1999년도 유체기계 연구개발 발표회 논문집
    • /
    • pp.245-251
    • /
    • 1999
  • The structural analysis of a reactor coolant pump(RCP) of a nuclear power plant is very important for the safety assessment of the plant. Accurate boundary conditions for the heat transfer coefficient are required for reliable thermal stress analysis of the pump casing, especially in transient operations of the pump since the coolant properties are largely dependent on operational conditions. In the present study, a 3D mixed flow type coolant pump was modeled from the RCP drawings and analyzed in the steady state and number of transient flow conditions by using a commercial code STAR-CD. From the result of the computation, it is seem that the average heat transfer coefficients for the cases considered are found to be the suggested values of the manufacturer, Westinghouse Energy System. The unevenness in local heat transfer coefficients, however, is found to be considerable so that the use of average heat transfer coefficients in all boundaries might not give reliable thermal stresses.

  • PDF

상용2회선 수전방식을 적용한 무정전 수변전설비 구축방안 검토·제안연구 (Construction of Uninterruptible Power System by Reliable Incoming Dual-Power Line)

  • 최진성;이상중
    • 조명전기설비학회논문지
    • /
    • 제24권12호
    • /
    • pp.64-70
    • /
    • 2010
  • High capacity UPS and emergency generators are commonly employed at facilities where power interruption is not allowed. Nowadays, combinations of existing commercial incoming power and an emergency generator or combination of multiple generators and CTTS(Closed Transition Transfer Switch) is adopted sometimes for more reliable power supply. In this paper, application of CTTS and STS(Static Transfer Switch) to dual-power line is suggested for highly reliable uninterruptible power. By realizing such a system, construction of incoming power facilities, installation of emergency generator and large capacity UPS can be omitted, through which saving of the installation space and corresponding capital investment can be expected.

무선 센서 네트워크에서 신뢰성 있는 데이터 전송과 혼잡 제어를 위한 프로토콜 (A Protocol for Reliable Data Transfer and Congestion Control in Wireless Sensor Networks)

  • 김현태;주영훈;나인호
    • 제어로봇시스템학회논문지
    • /
    • 제13권3호
    • /
    • pp.230-234
    • /
    • 2007
  • Generally, huge amounts of data traffic are generated by using broadcasting method to deliver sensing data to a sink node reliably so that it makes a severe network saturation problem resulting in unreliable data transfer. In order to handle this problem, a new congestion control protocol is required for supporting reliable data transfer, minimal use of energy and network resources at the same time in wireless sensor networks. In this paper, it proposes a Protocol to guarantee both a reliable transfer in data accuracy and minimum consumption of energy waste by using Hop-by-Hop sequence number and DSbACK(Delayed and Selective ACK Buffer Condition) scheme. In addition, it proves that reliability and energy efficiency are enhanced by the proposed method with the simulation results performed on TinyOS platform which is a component based built-in OS announced by UC Berkely with the performance comparison of other existing methods.

Force transfer mechanisms for reliable design of reinforced concrete deep beams

  • Park, Jung-Woong;Kim, Seung-Eock
    • Structural Engineering and Mechanics
    • /
    • 제30권1호
    • /
    • pp.77-97
    • /
    • 2008
  • In this paper, a strut-and-tie model approach has been proposed to directly calculate the amount of reinforcements in deep beams, and the force transfer mechanisms for this approach were investigated using linear finite element analysis. The proposed strut-and-tie model provides quite similar force transfer mechanisms to the results of linear finite element analysis for the 28 deep beams. The load-carrying capacities calculated from the proposed method are both accurate and conservative with little scatter or trends for the 214 deep beams. The deep beams have different concrete strengths including high-strength, various combinations of web reinforcements, and wide range of and a/d ratios. Good accuracy was also obtained using VecTor2, nonlinear finite element analysis tool based on the Modified Compression Field Theory. Since the proposed method provides a safe and reliable means for design of deep beams, this can serve to improve design provisions in future adjustments and development of design guidelines.

The Fault Diagnosis of a Transformer Using Neural Network and Transfer Function

  • Park, Byung-Koo;Kim, Jong-Wook;Kim, Sang-Woo;Park, Poo-Gyeon;Park, Tae-Joon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2001년도 ICCAS
    • /
    • pp.127.2-127
    • /
    • 2001
  • A transformer is one of the most important elements in the power network. Transformer faults could cause costly repairs and be dangerous to personnel. To avoid this, its reliable operation has great significance and, therefore, the diagnosis system of the transformer is necessitated. The dissolved gas-in-oil analysis (DGA) is the worldwide popular method of detecting faults such as a hot spot or partial discharges inside the transformer. DGA, however, is not a reliable technique to identify aging phenomena and mechanical faults including insulation failure, inter-turn short, etc. To overcome the drawbacks of DGA, the transfer function method is used to identify effectively these kinds of the mechanical faults. The transformer has a unique transfer function independent of the shape of the input waveform, which can be evaluated through sweep test. This transfer function changes by winding ...

  • PDF

원자로 냉각재 펌프의 과도 상태의 유동 및 열전달 해석 연구 (Flow and Heat Transfer Analysis of a Reactor Coolant Pump in Transient Conditions)

  • 허남건;김성원;유기풍;김승태
    • 한국유체기계학회 논문집
    • /
    • 제3권2호
    • /
    • pp.24-30
    • /
    • 2000
  • The structural analysis of a reactor coolant pump(RCP) of a nuclear power plant is very important for the safety assessment of the plant. Accurate boundary conditions for the heat transfer coefficient are required for reliable thermal stress analysis of the pump casing, especially in transient operations of the pump since the coolant properties are largely dependent on operational conditions. In the present study, a 3D mixed flow type coolant pump was modeled from the RCP drawings and analyzed in the steady state and number of transient flow conditions by using a commercial code STAR-CD. From the result of the computation, it is seen that the average heat transfer coefficients for the cases considered are found to be the suggested values of the manufacturer, Westinghouse Energy System. The unevenness in local heat transfer coefficients, however, is found to be considerable so that the use of average heat transfer coefficients in all boundaries might not give reliable thermal stress predictions.

  • PDF

신뢰도 높은 수전방식에 의한 무(無)정전 전원설비 구축방안 (Construction Of Uninterruptible Power System by Reliable Incoming Power Method)

  • 최진성;이상중
    • 한국조명전기설비학회:학술대회논문집
    • /
    • 한국조명전기설비학회 2007년도 추계학술대회 논문집
    • /
    • pp.367-371
    • /
    • 2007
  • 무(無)정전을 요구하는 특정대상의 중요 전기시설에서, 신뢰도 낮은 수전방식의 정전 가능성 대책으로 대용량의 UPS와 비상발전기를 설치 운영 중에 있다. 근래에 와서 상용전원과 발전기 또는 복수의 발전기에 CTTS (Closed Transition Transfer Switch)를 무(無)정전 전환개폐기 전용으로 사용하고 있다. 본 논문에서 CTTS를 신뢰도 높은 상용2회선 수전방식의 수전변압기 2차 측에 적용한 새로운 무(無)정전 전원설비 구축 방안을 제안하였다. 그 결과 수전설비 구성 간략화와, UPS 비상발전기 설치 최소화로 공간 및 투자절감 효과를 얻을 수 있다.

  • PDF

High Resolution Patternning for Graphene Nanoribbons (GNRs) Using Electro-hydrodynamic Lithography

  • Lee, Su-Ok;Kim, Ha-Nah;Lee, Jae-Jong;Kang, Dae-Joon
    • 한국진공학회:학술대회논문집
    • /
    • 한국진공학회 2012년도 제42회 동계 정기 학술대회 초록집
    • /
    • pp.198-198
    • /
    • 2012
  • Graphene has been the subject of intense study in recent years owing to its good optoelectronic properties, possibility for stretchable electronics, and so on. Especially, many research groups have studied about graphene nanostructures with various sizes and shapes. Graphene needs to be fabricated into useful devices with controllable electrical properties for its successful device applications. However, this been far from satisfaction owing to a lack of reliable pattern transfer techniques. Photolithography, nanowire etching, and electron beam lithography methods are commonly used for construction of graphene patterns, but those techniques have limitations for getting controllable GNRs. We have developed a novel nanoscale pattern transfer technique based on an electro-hydrodynamic lithography providing highly scalable versatile pattern transfer technique viable for industrial applications. This technique was exploited to fabricate nanoscale patterned graphene structures in a predetermined shape on a substrate. FE-SEM, AFM, and Raman microscopy were used to characterize the patterned graphene structures. This technique may present a very reliable high resolution pattern transfer technique suitable for graphene device applications and can be extended to other inorganic materials.

  • PDF

다단사이클론 예열소성로와 로터리킬른 소성로의 성능 모형평가: 시멘트공정사례 (Performance Evaluation of a Multistage-Cyclone Pre-heating Calciner and a Rotary Kiln Calciner: Case of a Cement Process)

  • 엄태규;최상민
    • 한국연소학회지
    • /
    • 제20권2호
    • /
    • pp.14-27
    • /
    • 2015
  • Calcination, which represents thermal decomposition of $CaCO_3$, is the key reaction in a cement process. Some reactions including heating-up also take place simultaneously in the calcination reactors. Basic thermal performance and dimensions of the reactors in two cases, which are a rotary kiln wih a four-stage cyclone pre-heater and a simple single rotary kiln, were compared. To employ the heat transfer, mass transfer and reaction rate as well as calcination, one-dimensional modeling was conducted in each case. Some simplification about the reactors was described, however, the reliable Nusselt number and heat transfer coefficients on the reactors were used to make results reliable.