• Title/Summary/Keyword: Reliability Simulator

Search Result 286, Processing Time 0.027 seconds

FTOG-based Recovery Services Through Replicated Objects (중복 객체를 통한 FTOG 모델 기반의 회복서비스)

  • Kang, Myung-Seok;Jung, Jae-Yun;Kim, Hag-Bae
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.31 no.12B
    • /
    • pp.1044-1048
    • /
    • 2006
  • This paper proposes a FTOG(Fault-Tolerant Object Group)-based recovery services through replicated objects. In the distributed system, the fault of the object component may cause an entire system failure, evidently raising the service breakdowns. Therefore, this paper proposes recovery services with the replicated objects in case of fault occurrences. Moreover, applying the FTOG model to a virtual home network simulation, we verify the consistency maintenance and the service reliability of the proposed model.

Dynamic Routing Protocol for Low-power and Ad-hoc Networks (저전력 애드혹 네트워크를 위한 동적 라우팅 프로토콜)

  • Hwang, So-Young;Yu, Don-Hui
    • Proceedings of the Korean Institute of Information and Commucation Sciences Conference
    • /
    • 2011.05a
    • /
    • pp.197-200
    • /
    • 2011
  • Many routing protocols have been proposed for low-power and ad-hoc networks where energy awareness and reliability are essential design issues. This paper proposes a dynamic routing protocol for low-power and ad-hoc networks. A dynamic path cost function is defined considering the constraints and characteristics of low-power and ad-hoc networks. The cost function can be applied flexibly depending on the characteristics of the networks. The performance of the proposed method is evaluated using a QualNet network simulator.

  • PDF

A study on Promotional App Development Using an Interactive Movie (인터랙티브 영상을 이용한 프로모션 앱 제작 연구)

  • Yoo, Wang-Yun
    • The Journal of the Korea Contents Association
    • /
    • v.14 no.10
    • /
    • pp.429-437
    • /
    • 2014
  • Product promotion App is developed using an interactive video in order to overcome the existing ATL marketing limitations and to respond to target age groups and lifestyle changes. The product promotion App which is positioned as a smart care center by analyzing customer needs with the Customer Journey Map, is comprised of 3 categories such as interest, information and management reflecting media characteristics of smart mobile contents. It intends to induce viral promotions with comical and interactive alopecia simulator directly described by a specialist doctor which ensures reliability of products. In addition, it is made for customers to continuously manage the alopecia through management tools, and company can expect an effect of being used as a core tool for marketing activities by offering promotional information along with product feedbacks.

Performance Investigation of Insulated Shallow Extension Silicon On Nothing (ISE-SON) MOSFET for Low Volatge Digital Applications

  • Kumari, Vandana;Saxena, Manoj;Gupta, R.S.;Gupta, Mridula
    • JSTS:Journal of Semiconductor Technology and Science
    • /
    • v.13 no.6
    • /
    • pp.622-634
    • /
    • 2013
  • The circuit level implementation of nanoscale Insulated Shallow Extension Silicon On Nothing (ISE-SON) MOSFET has been investigated and compared with the other conventional devices i.e. Insulated Shallow Extension (ISE) and Silicon On Nothing (SON) using the ATLAS 3D device simulator. It can be observed that ISE-SON based inverter shows better performance in terms of Voltage Transfer Characteristics, noise margin, switching current, inverter gain and propagation delay. The reliability issues of the various devices in terms of supply voltage, temperature and channel length variation has also been studied in the present work. Logic circuits (such as NAND and NOR gate) and ring oscillator are also implemented using different architectures to illustrate the capabilities of ISE-SON architecture for high speed logic circuits as compared to other devices. Results also illustrates that ISE-SON is much more temperature resistant than SON and ISE MOSFET. Hence, ISE-SON enables more aggressive device scaling for low-voltage applications.

An Intelligent Human-Machine Interface for Next Generation Nuclear Power Plants

  • Park, Seong-Soo;Park, Jin-Kyun;Hong, Jin-Hyuk;Chang, Soon-Heung;Kim, Han-Gon
    • Proceedings of the Korean Nuclear Society Conference
    • /
    • 1995.10a
    • /
    • pp.191-196
    • /
    • 1995
  • The intelligent human-machine interface (HMI) has been developed to enhance the safety and availability of a nuclear power plant by improving operational reliability The key elements of the HMI are the large display panels which present synopsis of the plant status and the compact, digital work stations for the primary operator control and monitoring functions. The work station consists of four consoles such as a dynamic alarm console (DAC), a system information console (SIC), a computerized operating-procedure console (COC), and a safety related information console (SRIC). The DAC provides clean alarm pictures, in which information overlapping is excluded and alarm impacts are discriminated, for quick situation awareness. The SIC covers a normal operation by offering all necessary plant information and control functions. In addition, it is closely linked with the DAC and the COC to automatically display related system information under the request of these consoles. The COC aids the operator with proper emergency operation guidelines so as to shutdown the plant safely, and it also reduces his physical/mental burden by automating the operating procedures. The SRIC continuously displays safety related information to allow the operator to assess the plant status focusing on plant safety. The proposed HMI has been validated and demonstrated with on-line data obtained from the full-scope simulator for Yonggwang Units 1,2.

  • PDF

Development of Automatic Coil-Handling Crane Control System (크레인 무인 자동 운전 시스템 개발)

  • Choi Chintae;Shin K.
    • Proceedings of the Korean Society for Technology of Plasticity Conference
    • /
    • 2004.08a
    • /
    • pp.126-133
    • /
    • 2004
  • Lots of researches and applications on the automated overhead cranes in shops have been done for some decades, but a few successful results are reported. Integrated crane control systems designed by famous engineering companies are still expensive and are not satisfactory in view of maintenance and reliability. A more reasonable control system fit to requirements of manufacturing industries is suggested in the study. The new deigned system has superior capabilities for anti-sway of rope and position control. The controller for automated operations is composed of a Linux-based PC for non real-time control and a high-speed PLC for hard real-time control. Some algorithms required for coil yard operations as well as main control algorithms such as reference position generation, position control and anti-sway control have been designed and fully tested on the new crane simulator. The designed crane control system showed satisfactory performance on position control accuracy and anti-sway of rope. The maximum positional error is 8mm and the maximum sway error is 0.1 degrees. The suggested control strategies have been successfully applied to the 10-1 crane in No. 4 CGL of in the Kwangyang Steel Works and in commercial operation.

  • PDF

The Development of Boiler Feedwater Master Control System for Power Plant (발전소 보일러 급수 주제어 시스템의 개발)

  • Lim, Gun-Pyo;Park, Doo-Yong;Kim, Jong-Ahn;Lee, Heung-Ho
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.3
    • /
    • pp.442-450
    • /
    • 2012
  • Almost domestic power plants are being operated by foreign distributed control system. Many korean power plants are being operated over their lifetime so they need to be retrofitted. So we are developing the distributed control system to solve this problem by our own technique. The simulator was already made to verify the reliability of the algorithms. The unit loop function tests of all algorithms were finished in the actual distributed control system for installation of power plant and their results were satisfactory. The unit loop function tests are for each unit equipment algorithm. So the total operation tests will be made with all algorithms together in the actual distributed control system to be applied to power plant. When the verification through all tests is finished, algorithms with hardware will be scheduled to be installed and operated in the actual power plant. This research result will contribute to the safe operation of the deteriorated power plant and korean electric power supply as well as domestic technical progress. This entire processes and results for the development are written for the example of boiler feedwater master algorithm out of all algorithms in this paper.

A Scheme of Transmission of Multimedia Stream Through SCTP (SCTP를 통한 멀티미디어 스트림 전송기법 연구)

  • Seok, Seung-Joon
    • Journal of Korea Multimedia Society
    • /
    • v.10 no.3
    • /
    • pp.401-410
    • /
    • 2007
  • Multimedia streams transmitted through the Internet have a strict playback delay time. Multimedia data arriving aster the playback time cannot be played in the receiver and are discarded. Thus, this paper proposed a protocol, in which the multimedia stream server determines whether data can be played in the receiver before sending the data. The proposed model has a PSCTP sub-layer on top of existing PR-SCTP and decides whether to send data messages, which have come from the multimedia applicationserver, and which PR-SCTP stream the data will be sent to. In addition, the proposed model uses the differentiated retransmission function of PR-SCTP. We evaluated the performance of SCTP, PR-SCTP and PSCTP using NS2 simulator. According to the results of the evaluation, the PSCTP protocol decreased the volume of transmission and increased the video decodable ratio compared to other protocols.

  • PDF

KOMPSAT-1 Satellite Orbit Control using GPS Data

  • Lee, Jin-Ho;Baek, Myuog-Jin;Koo, Ja-Chun;Yong, Ki-Lyuk;Chang, Young-Keun
    • International Journal of Aeronautical and Space Sciences
    • /
    • v.1 no.2
    • /
    • pp.43-49
    • /
    • 2000
  • The Global Positioning System (GPS) is becoming more attractive navigation means for LEO (Low Earth Orbit) spacecraft due to the data accuracy and convenience for utilization. The anomalies such as serious variations of Dilution-Of-Precision (DOP), loss of infrequent 3-dimensional position fix, and deterioration of instantaneous accuracy of position and velocity data could be observed, which have not been appeared during the ground testing. It may cause lots of difficulty for the processing of the orbit control algorithm using the GPS data. In this paper, the characteristics of the GPS data were analyzed according to the configuration of GPS receiver such as position fix algorithm and mask angle using GPS navigation data obtained from the first Korea Multi-Purpose Satellite (KOMPSAT). The problem in orbit tracking using GPS data, including the infrequent deterioration of the accuracy, and an efficient algorithm for its countermeasures has also been introduced. The reliability and efficiency of the modified algorithm were verified by analyzing the effect of the results between algorithm simulation using KOMPSAT flight data and ground simulator.

  • PDF

the power flow control and voltage compensation by 20kVA prototype UPFC (20kVA급 Prototype UPFC의 전력조류제어와 모선전압보상)

  • Jeon, Jin-Hong;Kim, Ji-Won;Chun, Yeung-Han;Kim, Hak-Man;Kook, Kyung-Soo;Oh, Tae-Kyoo
    • Proceedings of the KIEE Conference
    • /
    • 2001.04a
    • /
    • pp.349-352
    • /
    • 2001
  • FACTS technology is developed into the sophisticated system technology which combines conventional power system technology with power electronics, micro-process control, and information technology. Its objectives are achieving enhancement of the power system flexibility and maximum utilization of the power transfer capability through improvements of the system reliability, controllability, and efficiency [1]. As a series and shunt compensator, UPFC consists of two inverters with common dc link capacitor bank. It controls the magnitude of shunt bus voltage and real and reactive power flow of transmission line[2]. In this paper, we present the design, implementation and test results of developed 20kVA level prototype UPFC. It is applied to power system simulator and controls the real and reactive power flow and shunt bus voltage magnitude.

  • PDF