• 제목/요약/키워드: Relative permeability

검색결과 244건 처리시간 0.026초

부직포 충전재의 구조적 특성이 수분전달 특성에 미치는 영향-단층구조와 이층구조 부직포의 비교- (The Effect of Geometrical Structure on the Moisture Transport Properties of Nonwoven Batting Materials)

  • 김희숙;나미희
    • 한국의류학회지
    • /
    • 제24권6호
    • /
    • pp.810-818
    • /
    • 2000
  • The purpose of this study was to analyze the effect of geometrical structure on the moisture transport properties of nonwoven batting materials. Two types of nonwovens were used such as single and double layered nonwovens. Steady and dynamic state water vapor transport properties were measured by absorption, evaporation and cobaltous chloride method respectively. The results of this study were as follows: 1) Geometrical structure affected water vapor evaporation, but there were no differences between single and double layered nonwovens in moisture absorption. Thickness and air permeability were influencing factor on water vapor transport rate. 2) Directionality of double layered nonwoven was observed both in steady and dynamic state moisture transport. There were differences between upper and lower layer of double layered nonwoven both in moisture absorption rate and color change by cobaltous chloride method. 3) In dynamic state of water vapor transport rate, single layered nonwoven reached more rapidly at the established relative humidity. It was confirmed that geometrical structure affected water vapor evaporation and hydrophilicity of fiber affected moisture absorption because there were much more water vapor transport rate by evaporation than absorption within the same period of time.

  • PDF

유한요소법을 이용한 IH-JAR의 열확산 예측에 관한 연구 (A Study on the Heat-Diffusion Prediction of Induction Heating JAR using Finite Element Method)

  • 오홍석
    • 한국화재소방학회논문지
    • /
    • 제16권2호
    • /
    • pp.8-13
    • /
    • 2002
  • 유도가열 기술은 담금질, 단조를 위한 예열, 용융 그리고 요리 등과 같은 산업 전반에 걸쳐서 아주 폭넓게 사용되는 기술이다. 본 논문에서는 IH-JAR의 효과적인 설계를 위하여 자계 및 열 해석을 하였다. IH-lAR의 내부자계는 3차원 축대칭 유한요소법을 사용하여 해석하였으며, 열원은 IH-JAR 내부에서 유도된 와전류에 의하여 발생되고, 열은 열원과 열방정식을 사용하여 계산되어진다. 또한, IH-JAR의 온도분포를 시간과 투자율에 따라 제시하였다.

화학적 합성에 의해 제조된 직접 메탄올 연료전지용 나피온/백금/폴리피롤 복합 막의 특성 분석 (Characterization of Nafion/Pt/Polypyrrole Composite Membrane Prepared by Chemical In-situ Polymerization for DMFC)

  • 박호석;김여진;임현숙;최봉길;홍원희
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 한국신재생에너지학회 2006년도 추계학술대회
    • /
    • pp.421-424
    • /
    • 2006
  • Nafion/Pt/Polypyrrole composite membranes were fabricated by chemical in-situ polymerization of pyrrole monomers with Pt precursors in Nafion matrix for DMFC. We demonstrated that positively charged pyrrolinum groups of polypyrrole particles were co-interacted with sulfonic groups of Nafion as verified by FT-IR results. Mutual interaction between $Nafion-SO_3^-$ (or negatively charged Pt precursors) and Polypyrrole$-NH_2^+$ influenced the physical properties of pristine Nafion. Thermal property proton conductivity, methanol permeability, and cell performance of pristine and modified Nafion were analyzed for an application of DMFC membrane. Thermal stabilities of sulfonic groups and side chains in Nafion/Pt/polypyrrole composite membranes were higher than those of Nafion due to mutual interaction between sulfonic groups of Nafion and pyrrolinum groups of polypyrrole. Methanol permeabilities of Nafion/Pt/Polypyrrole composite were reduced more proton conductivities with the increase in the content of Pt particles. As a result of that, the enhancement of cell performance by Nafion/Pt/Polypyrole O2 relative to Nafion was more pronounced under the specific experimental condition such as high temperature and more concentrated methanol solution.

  • PDF

HYSTERETIC MODELING ON THE CONVECTIVE TRANSPORT OF ORGANIC SOLVENT IN AN UNSATURATED SOIL ZONE

  • Lee, Kun-Sang
    • Environmental Engineering Research
    • /
    • 제11권5호
    • /
    • pp.241-249
    • /
    • 2006
  • A mathematical model is described for the prediction of convective upward transport of an organic solvent driven by evaporation at the surface, which is known as the major transport mechanism in the in-situ photolysis of a soil contaminated with 2,3,7,8-tetrachlorodibenzo-p-dioxin(TCDD). A finite-element model was proposed to incorporate the effects of multiphase flow on the distribution of each fluid, gravity as a driving force, and the use of hysteretic models for more accurate description of k-S-p relations. Extensive numerical calculations were performed to study fluid flow through three types of soils under different water table conditions. Predictions of relative permeability-saturation-pressure (k-S-p) relations and fluids distribution for an illustrative soil indicate that hysteresis effects may be quite substantial. This result emphasizes the need to use hysteretic models in performing flow simulations including reversals of flow paths. Results of additional calculations accounting for hysteresis on the one-dimensional unsaturated soil columns show that gravity affects significantly on the flow of each fluid during gravity drainage, solvent injection, and evaporation, especially for highly permeable soils. The rate and duration of solvent injection also have a profound influence on the fluid saturation profile and the amount of evaporated solvent. Key factors influencing water drainage and solvent evaporation in soils also include hydraulic conductivity and water table configuration.

The Characterization of the Increase of Membrane Conductance after Depolarization in Single Rat Adrenal Chromaffin Cells

  • Lim, Won-Il;Kim, Sang-Jeong;Kim, Jun
    • The Korean Journal of Physiology and Pharmacology
    • /
    • 제2권1호
    • /
    • pp.95-100
    • /
    • 1998
  • The conductance change evoked by step depolarization was studied in primarily cultured rat adrenal chromaffin cells using patch-clamp and capacitance measurement techniques. When we applied a depolarizing pulse to a chromaffin cell, the inward calcium current was followed by an outward current and depolarization-induced exocytosis was accompanied by an increase in conductance trace. The slow inward tail current which has the same time course as the conductance change was observed in current recording. The activation of slow tail current was calcium-dependent. Reversal potentials agreed with Nernst equation assuming relative permeability of $Cs^+\;to\;K^+$ is 0.095. The outward current and tail current were blocked by apamin (200 nM) and d-tubocurarine (2 mM). The conductance change was blocked by apamin and did not affect membrane capacitance recording. We confirmed that conductance change after depolarization comes from the activation of the SK channel and can be blocked by application of the SK channel blockers. Consequently, it is necessary to consider blocking of the SK channel during membrane capacitance recording.

  • PDF

슬래그 다짐말뚝의 원심모델링 (Centrifuge Modelling of Slag Compaction Pile)

  • 유남재;박병수;정길수;이명욱
    • 산업기술연구
    • /
    • 제22권B호
    • /
    • pp.191-197
    • /
    • 2002
  • This paper is experimental and numerical research results of performing centrifuge model tests to investigate the geotechnical engineering behavior of slag compaction pile as a substitute of sand compaction pile. In order to find the geotechnical engineering characteristics of the soft clay and the slag used in centrifuge model experiments, basic soil property tests, consolidation test, permeability tests and triaxial compression tests were performed. For centrifuge model tests, slags with changing relative density were used and their bearing capacity, stress concentrations in between pile and soft clay, settlement characteristics, and failure modes were investigated. As a results of centrifuge model tests, it was found that the bearing, capacity of model was increased with increasing density of slag pile and general shear failures were occured. Miniature soil pressure gauges were installed on model pile and soft ground respectively and thus vertical stress acting on them were measured. Stress concentration ratio was found to be in the range of 2.0~3.0. Bearing capacity obtained from the model test with slag was greater than that from the model test with a sand having the identical layout to each other. Thus it was confirmed the slag was an appropriate substitution of pile for sand.

  • PDF

Waste Isolation Pilot Plant Performance Assessment: Radionuclide Release Sensitivity to Diminished Brine and Gas Flows to/from Transuranic Waste Disposal Areas

  • Day, Brad A.;Camphouse, R.C.;Zeitler, Todd R.
    • Nuclear Engineering and Technology
    • /
    • 제49권2호
    • /
    • pp.450-457
    • /
    • 2017
  • Waste Isolation Pilot Plant repository releases are evaluated through the application of modified parameters to simulate accelerated creep closure, include capillary pressure effects on relative permeability, and increase brine and gas saturation in the operations and experimental (OPS/EXP) areas. The modifications to the repository model result in increased pressures and decreased brine saturations in waste areas and increased pressures and brine saturations in the OPS/EXP areas. Brine flows up the borehole during a hypothetical drilling intrusion are nearly identical and brine flows up the shaft are decreased. The modified parameters essentially halt the flow of gas from the southern waste areas to the northern nonwaste areas, except as transported through the marker beds and anhydrite layers. The combination of slightly increased waste region pressures and very slightly decreased brine saturations result in a modest increase in spallings and no significant effect on direct brine releases, with total releases from the Culebra and cutting and caving releases unaffected. Overall, the effects on total high-probability mean releases from the repository are insignificant, with total low-probability mean releases minimally increased. It is concluded that the modified OPS/EXP area parameters have an insignificant effect on the prediction of total releases.

스커트의 열특성에 관한 연구 (A Study on the Thermal Properties of Skirts)

  • 최혜선
    • 한국의류학회지
    • /
    • 제13권4호
    • /
    • pp.388-399
    • /
    • 1989
  • The purpose of this study was to investigate the effects of garment design, fabric type and the presence of lining on the thermal insulation value $(I_{cle}\;and\;I{cl})$ and clothing area factor $(f_{cl})$ of skirts. A standing, electrically heated thermal maninkin was used to measure the insultation value of eighty skirts-five skirt styles with eight different fabrics, with and without lining. The air temperature of the chamber was set at $22.2^{\circ}C{\pm}0.5^{\circ}C$ , air velocity was limited to less than 0.1 m/s, and relative humidity was approximately $50\%$. The results are as follows: 1) The Ic, values of gathered skirt and flared skirt, which had high $f_{cl}$ values, were significantly higher than those of other skirts, though the highest $I_{cle}$ value among five styles wer pegged skirt. 2) Insulation values of various skirts were more relevant with physical properties such as thickness, air permeability, and thermal transmission of the materials rather than fiber content. 3) The addition of lining made significant difference in the insulation values of skirts and the differences of gathered and flared skirt were significantly higher than those of othere types of skirts.

  • PDF

${\mu}$-metal을 이용한 765kV 송전선의 자계 차폐에 관한 연구 (The Shielding of Magnetic field of 765kV transmission line by use of ${\mu}$-metal)

  • 이승철;장용무;이방욱;김정한;구자윤
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 제39회 하계학술대회
    • /
    • pp.1328-1329
    • /
    • 2008
  • 2000년 대 이후 송전선의 상태 및 송전선 주변 환경을 감시하기 위한 각종 센서들을 하나의 시스템으로 통합하여 실 선로에 적용하는 연구가 활발히 진행되고 있으며, 국내에서도 최근 765kV급 송전선을 감시하기 위한 통합 센서 시스템 개발을 진행 중에 있다. 이를 위해서는 송전선로에서 발생되는 자계로부터 센서 통합 시스템을 보호하기 위한 자계 차폐에 대한 연구가 선행되어야 한다. 따라서 본 논문에서는 상용 주파수에서 약 80,000[H/m]이상의 투자율(${\mu}_r$ : relative permeability)를 갖는 강자성체인 ${\mu}$-metal을 사용하여 765kV급 송전선 (2,000A/single phase)에 대한 차폐율을 연구하였고, 이를 위해 ${\mu}$-metal의 차폐율을 검증할 수 있는 magnetic probe를 자체 설계 제작하였다. 그 결과 magnetic probe에 의해 측정된 자계의 크기 및 분포를 통해 ${\mu}$-metal의 layer의 개수에 따라 변화하는 자계 차폐율을 분석할 수 있었다.

  • PDF

저전류/저가습 조건에서 고분자전해질 막 열화 (Degradation of Polymer Electrolyte Membrane under Low Current/Low Humidity Conditions)

  • 김태희;이정훈;이호;임태원;박권필
    • 한국수소및신에너지학회논문집
    • /
    • 제18권2호
    • /
    • pp.157-163
    • /
    • 2007
  • During PEMFC operation, low current and low humidity conditions accelerate the degradation of perfluorosulfonic acid membrane. But, there have been no studies that clearly explain why these conditions accelerate the membrane degradation. In this study, the hydrogen permeability through the membrane, I-V polarization of MEA, fluoride emission rate(FER) in effluent water were measured during cell operation under low current densities and low relative humidity(RH). The experimental results were evaluated with oxygen radical mechanism the most commonly known for membrane degradation. It seems that low RH of anode is a good condition for $H{\cdot}$ radical formation on the Pt catalyst and the low current condition accelerates the $H{\cdot}$ to form $HO_2{\cdot}$ radical attacking the polymer membrane.