• Title/Summary/Keyword: Reinforcement-reduction

Search Result 477, Processing Time 0.022 seconds

Change of groundwater inflow by cutoff grouting thickness and permeability coefficient

  • Kim, Youngsang;Moon, Joon-Shik
    • Geomechanics and Engineering
    • /
    • v.21 no.2
    • /
    • pp.165-170
    • /
    • 2020
  • The groundwater during tunnel excavation not only affects the stability of the tunnel and constructability but also causes the subsidence of the upper ground due to the lowering of groundwater. Generally, the cutoff grouting is applied as a countermeasure to reduce the groundwater inflow during tunnel excavation, and the cutoff grouting is often applied in the range of plastic zone around the tunnel. However, grouting in the plastic zone is only appropriate for ground reinforcement purposes, and guidelines for the application range of cutoff grouting and the targeted permeability coefficient of the grouting zone are required. In this study, the relationship between groundwater inflow into tunnel and application range of cutoff grouting and permeability coefficient is proposed and compared with numerical analysis results. It was found that grouting with tunnel radius thickness is appropriate to reduce the groundwater inflows effectively. More than 90% reduction in groundwater inflow can be achieved when the annular area of the tunnel radius thickness is grouted with a permeability reduction ratio of 1/50~1/200.

A Survey of Actual State of Treatment with Acupuncture and Moxibustion in Korea (한국 침구 치료 현황 파악을 위한 설문조사)

  • Han, Chang-Hyun;Shin, Sun-Wha;Ahn, Sang-Woo;Choi, Sun-Mi
    • Journal of Acupuncture Research
    • /
    • v.22 no.6
    • /
    • pp.141-153
    • /
    • 2005
  • Objectives : This survey was accomplished to find out how Korean medical doctors take acupuncture treatment in real clinics. Methods : The survey questions were developed by the consensus from the professors who major in acupuncture and moxibustion. The questionnaire was given the 2731 Korean medical doctors at the mending education site; In addition, it was given to 793 doctors working at the 105 Korean medical hospitals listed on the National Korean Medical Hospital Associations Address book by postal mail; and also it was given to the 142 public health care Korean medical doctors who attended the conference for the municipal and provincial representatives of the public health service Korean medical doctors. Total of 1277 questionnaires were retrieved out of the 3666 subjects. Results : 1. Nine hundred out of 1277 Korean medical doctors used method of differentiation syndromes(70.4%) and 1184 out of 1277 Korean medical doctors convalescence decide with subjective symptom improvement of patient(92.6%). 2. Nine hundred eight out of 1277 Korean medical doctors used both local and remote points(71.0%) and 916 out of 1277 Korean medical doctors treat with method of reinforcement-reduction(71.7%). 3. Eleven hundred fifth five out of 1277 Korean medical doctors used cupping a boil(90.3%) and 1023 out of 1277 Korean medical doctors used moxibustion(80.1%). Conclusion : When Korean medical doctors treat with acupuncture, most of them diagnose with differentiation methods and meridian theory, decide convalescence with subjective symptom improvement of patient, select out of both local and remote acupuncture points, treat with method of basic reinforcement-reduction, apply moxa and cupping a boil when they are necessary. The cupping a boil comes to be used when being muscle and joint disease. The moxa comes to be used when being chronic disease.

  • PDF

Comparison Analysis of Factor of Safety on Rock Slope in Boeun Region Using Distinct Element Method and Limit Equilibrium Method (개별요소법과 한계평형법을 이용한 보은지역 암반사면 안전율 비교해석)

  • 이지수;유광호;박혁진;민경덕
    • Journal of the Korean Geotechnical Society
    • /
    • v.19 no.4
    • /
    • pp.33-41
    • /
    • 2003
  • The large planar failure has occurred in a rock cut slope of highway construction site in Boeun. This area is considered to be unstable since the discontinuity, whose orientation is similar to the orientation of the failure plane, is observed in many areas. Therefore, several analysis techniques such as SMR, stereographic analysis, limit equilibrium, numerical analysis, which are commonly used in rock slope stability analysis, are adopted in this area. In order to analyze the stress redistribution and nonlinear displacement caused by cut, which are not able to be obtained in limit equilibrium method, DEM and shear strength reduction technique were used in this study. Then the factors of safety evaluated by shear strength reduction technique and limit equilibrium were compared. In addition, the factor of safety under fully saturated slope condition was calculated and subsequently, the effect of the reinforcement was evaluated.

The Effect of Health Care Expenditure on Income Inequality (의료비 지출이 소득불평등에 미치는 영향)

  • Song, Eun-Cheol;Kim, Chang-Yup;Shin, Young-Jeon
    • Health Policy and Management
    • /
    • v.20 no.3
    • /
    • pp.36-57
    • /
    • 2010
  • The degree of income inequality deepened by health care expenditure was useful in assessing the health security level. This exploratory study was conducted to provide a basic evidence to prove the necessity of reinforcement the benefit coverage of South Korea's health security systems. Data from the Household Income and Expenditure Survey of Korea and Luxembourg Income Study were used. Income inequality indices before and after deduction of health care expenditure were computed, and the degree of the increase in the indices was compared among 13 countries. The degree of decrease against the effect of income inequality reduction policies by health care expenditure was determined. The relationships between the national characteristics and the increase in income inequality were examined. In South Korea, all income inequality indices increased after deducting health care expenditure, but the difference was not high compared to the mean of 13 countries. However, the degree of decrease against the effect of income inequality reduction policies by health care expenditure was high, compared to the mean of 13 countries. The proportion of public sector spending on health care proved to be statistically significant with the increase of income inequality indices (p<0.05). In the context of the continuous increase in health care expenditure, if benefit coverage of health security systems is not reinforced, income inequality will all the more increase due to health care expenditure. In the establishment of the policies for reinforcement of the benefit coverage, income inequality after deduction of health care expenditure should be continuously monitored.

Constructability and Cost Analysis of the Clip-Type Binding Implement Substituting 135° End-Hooked Transverse Reinforcement in Reinforced Concrete Columns (철근콘크리트 기둥의 띠철근에서 135° 갈고리 대체 클립형 연결장치의 시공성 및 비용 분석)

  • Park, Koung-Yeun;Yun, Hyun-Do
    • Journal of the Korea Institute of Building Construction
    • /
    • v.20 no.5
    • /
    • pp.459-469
    • /
    • 2020
  • The purpose of this study is to secure the same or more structural performance and constructability for the detail off hooks cross-constructed at 135° used as external-ties standard detail in reinforced concrete columns, therefore, to the purpose of improving constructability, The clip-type binding implement was suggested. the experiment on the constructability evaluation and cost analysis of the clip-type binding implement by 90° end-hooked transverse reinforcement in reinforced conrete columns was carried out. The results of the analysis confirmed that standard detail column took about an one hour regardless of the diameter of tie. When using the clip-type binding implement, It was reduced to about 50% of the standard detail column. and regardless of the building size, it was most effective for the cost down when using the clip-type binding implement 1ea, it was about 32% fo labor cost reduction effect in comparison with using standard detail. as a result, Using the clip-type binding implement is shown be very effective in the working time and construction cost reduction.

A Study on the Application of Low Crest Structures to Reduce Wave Overtopping (월파저감을 위한 저마루 구조물의 적용성 검토)

  • Kyu-Tae, Shim;Kyu-Han, Kim;Ki-Seock, Cha
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.34 no.6
    • /
    • pp.290-302
    • /
    • 2022
  • In this study, it was examined for the reduction of wave overtopping and water level fluctuation in front of the revetment when applying a reinforcement method to revetment where wave overtopping occurs. As a result of the study, in the case of the cross-sectional experiment. more than 70% of the wave overtopping reduction effect depending on the reinforcement conditions was occurred, and it was analyzed that the result increases by about four times or more in the comparison with the 3d test. The average water level in front of the revetment was lowered when a low crest structure was not installed. and there was a tendency to rise under the condition of low crest structures installed. In the comparison with the wave basin test, there was a difference of about 0.5 to 0.6 times when a low crest structure was not installed, and it was increased by 5.5 times after low crest structures were installed.

Global Stability of Geosynthetic Reinforced Segmental Retaining Walls in Tiered Configuration (계단식 블록식 보강토 옹벽의 전체 안전성)

  • Yoo, Chung-Sik;Kim, Sun-Bin
    • Journal of the Korean Geotechnical Society
    • /
    • v.24 no.9
    • /
    • pp.23-32
    • /
    • 2008
  • This paper presents the global stability of geosynthetic reinforced segmental retaining walls in tiered configuration. Four design cases of walls with different geometries and offset distances were analyzed based on the FHWA and NCMA design guidelines and the discrepancies between the different guidelines were identified. A series of global slope stability analyses were conducted using the limit-equilibrium analysis and the continuum mechanics based shear strength reduction method with the aim of identifying failure patterns and the associated factors of safety. The results indicated among other things that the FHWA design approach yields conservative results both in the external and internal stability calculations, i.e., lower factors of safety, than the NCMA design approach. It was also found that required reinforcement lengths are usually governed by the global slope stability requirement rather than the external stability calculations. Also shown is that the required reinforcement lengths for the upper tiers are much longer than those based on the current design guidelines.

The Effect of Out-of-Plane Load on the In-Plane Shear Capacity of Reinforcement Concrete Shear Wall (철근 콘크리트 전단벽에서 면외 하중이 면내 전단성능에 미치는 영향)

  • Shin, Hye Min;Park, Jun Hee
    • Journal of the Earthquake Engineering Society of Korea
    • /
    • v.28 no.2
    • /
    • pp.77-83
    • /
    • 2024
  • The design shear strength equations of RC shear walls have been developed based on their performance under in-plane (IP) loads, thereby failing to account for the potential performance degradation of shear strength when subjected to simultaneous out-of-plane (OOP) loading. Most of the previous experimental studies on RC walls have been conducted in one direction under quasi-static conditions, and due to the difficulty in experimental planning, there is a lack of research on cyclic loading and results under multi-axial loading conditions. During an earthquake, shear walls may yield earlier than their design strength or fail unexpectedly when subjected to multi-directional forces, deviating from their intended failure mode. In this paper, nonlinear analysis in finite element models was performed based on the results of cyclic loading experiments on reinforced concrete shear walls of auxiliary buildings. To investigate the reduction trend in IP shear capacity concerning the OOP load ratio, parametric analysis was conducted using the shear wall FEM. The analysis results showed that as the magnitude of the OOP load increased, the IP strength decreased, with a more significant effect observed as the size of the opening increased. Thus, the necessity to incorporate this strength reduction as a factor for the OOP load effect in the wall design strength equation should be discussed by performing various parametric studies.

Predicting the flexural capacity of RC beam with partially unbonded steel reinforcement

  • Wang, Xiao-Hui;Liu, Xi-La
    • Computers and Concrete
    • /
    • v.6 no.3
    • /
    • pp.235-252
    • /
    • 2009
  • Due to the reduction of bond strength resulting from the high corrosion level of reinforcing bars, influence of this reduction on flexural capacity of reinforced concrete (RC) beam should be considered. An extreme case is considered, where bond strength is complete lost and/or the tensile steel are exposed due to heavy corrosion over a fraction of the beam length. A compatibility condition of deformations of the RC beam with partially unbonded length is proposed. Flexural capacity of this kind of RC beam is predicted by combining the proposed compatibility condition of deformations with equilibrium condition of forces. Comparison between the model's predictions with the experimental results published in the literature shows the practicability of the proposed model. Finally, influence of some parameters on the flexural capacity of RC beam with partially unbonded length is discussed. It is concluded that the flexural capacity of the beam may not be influenced by the completely loss of bond of the whole beam span as long as the tensile steel can yield; whether or not the reduction of the flexural capacity of the beam resulting from the loss of bond over certain length may occur depends on the detailed parameters of the given beam.

A Study on the Reduction Method of Heavy-weight floor impact sound and Plumbing noise in Decrepit Apartment houses (노후 아파트의 바닥충격음 및 급·배수 소음 저감방안에 관한 연구)

  • Joo, Moon Ki;Han, Myung Ho;Oh, Yang Ki
    • KIEAE Journal
    • /
    • v.9 no.2
    • /
    • pp.99-106
    • /
    • 2009
  • The noise in apartment buildings are major factor that determine the quality of indoor noise environment. Particularly, the noise from children's running footsteps and plumbing noise have caused the residents who live in decrepit apartment houses to uncomfortable environment. And as time go by, sound performance are getting worse according to the aging of the facilities. So this study deals with the plans to improve the sound performance of decrepit apartment house. To compare the noise reduction, we measured the heavy-weight impact sound level and plumbing noise level before and after changes the measurement conditions. As the results of measurements, the heavy-weight impact sound level were decreased when stiffness reinforcement were installed on slab. Especially the sound level were decreased 2.1-7.6dB in 50-80Hz of low frequency range. Instead of PVC pipe system, cast iron pipe and triple elbow drain pipe systems were installed. Noise level were decreased 15dB(A) in 250Hz. Noise level of pipe system's on the slab is less than under slab one. On the contrary water saving stool showed increasing the noise level.