• Title/Summary/Keyword: Reinforcement type

Search Result 886, Processing Time 0.031 seconds

Development of the Bone Type Concrete Spacer with Crack Resistance for Construction (시공균열저항성을 갖는 본타입 콘크리트 스페이서 개발)

  • Lee, Min-Jae;Kim, Ji-Ho;Sung, Jong-Hyun;Choi, Duck-Jin;Kim, Jin-Man
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2012.11a
    • /
    • pp.35-38
    • /
    • 2012
  • Spacers which we have studied is the secondary product of the concrete to apply on concrete structure. It is needed to secure equal or greater performance than structural concrete that it is applied. There is a tendency that concrete structures are strengthened more and more. Therefore, designed set up position of reinforcement is used more and more, so it is needed increasingly high strength spacer. We have been doing a series of research to develop the different typed high strength spacer having crack resistance during constructing. The bearing load of different type spacer shows approximately 35% lower load than those in the general spacers.

  • PDF

Seismic Performance Evaluation According to Seismic Retrofit Techniques of Existing School Buildings (기존 학교건축물의 내진보강기법에 따른 내진성능평가)

  • Kang, Jong
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.15 no.1
    • /
    • pp.29-36
    • /
    • 2012
  • Reinforced concrete shear walls and X-type steel braces were applied in seismic retrofit techniques for seismic performance evaluation of school buildings constructed in accordance with standard design announced by the ordinance of the ministry of construction in 1980s. Seismic performance evaluation was based on FEMA 356 using response spectrum as elastic analysis and conducted to pushover analysis with nonlinear static analysis. The maximum displacement ratio between floors in 4th and 3rd floors of the existing school buildings was less than 1.0%, which was functioning level in FEMA 356. However, because plastic hinge occurs somewhat in structural members according to the results of pushover analysis, partial reinforcement will be required. X-direction of the maximum lateral displacement of reinforced concrete shear walls than X-type steel braces was 45% and 32% in 4th and 3rd floors of school buildings, and Y-direction was 18% and 17%, respectively.

Seismic Performance Evaluation of Circular RC Bridge Piers with Various Steel Type (원형 실물 철근 콘크리트 교각의 철근 상세에 따른 내진성능 평가)

  • 정영수;박진영;이재훈;조대연;이대형
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2001.11a
    • /
    • pp.965-970
    • /
    • 2001
  • The object of this research is to evaluate the seismic performance of existing RC bridge piers that were constructed before the adoption of the seismic design provision of Korea Bridge Design Specification in 1992. In this research, adopted test parameters were limited ductile design or non-seismic design, aspect ratio, confinement steel type, loading pattern, lap-spliced ratio for longitudinal reinforcement. This study has been performed to verify the effect of test parameter by quasi-static test. Quasi-static test has been done to investigate the physical seismic performance of RC bridge piers, such as lateral force-displacement hysteretic curve, envelope curve etc. It has been observed that seismic performance of lap-spliced test specimen, non-seismically designed specimens, was significantly reduced.

  • PDF

A Survey on the Arrangement of Reinforcing Bars in Wall-Slab Type Apartment Buildings (벽식구조 아파트의 철근배근에 관한 조사연구)

  • 임재중;윤영호;양지수;정하선;이리형;홍성목
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1990.04a
    • /
    • pp.45-50
    • /
    • 1990
  • The purpose of this study was to find, through field and questionaire survey, the problems in arrngement of reinforcing bars in wall-slab type apartment buildings. The survey was done in 88 construction sites over the country. The findings from the survey were as followed : (1) reinforcement details were unnecessarily complex in some structural members and could be simplified without sacrificing the safety of the structures; (2) It was found in many cases that drawings of reiforcement failed to show the location of the laps, bent-up positions, and the development length; and (3) it was often found that the workers did not understand the importance of tloerence limits and anchorage in the steel bar arrangement.

  • PDF

Probabilistic Analysis on the Fatigue-Life of the Strengthened Bridge Decks (성능향상된 교량 바닥판에서의 피로수명에 대한 확률론적 해석)

  • 심종성;오홍섭;류승무;박성재
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 2002.05a
    • /
    • pp.393-398
    • /
    • 2002
  • This study shows the fatigue test results of experiment on the strengthened slabs, the probability analysis of the fatigue behavior is also presented. Static und fatigue tests were performed on bridge decks strengthened with fiber plastics(Carbon Fiber Sheet, Glass Fiber Sheet, Grid Type Carbon Fiber). In this study, to analyze the probabilistic distribution of the fatigue life, the Weibull distribution was adopted. The Weibull distribution coefficient is inferred from the S-N diagram and the number of repeated load. As the result analysis, as the stress level is higher, the fatigue limit of the strengthened bridge deck are similarly discovered but in the range of the fatigue limit, CG specimen that was strengthened with Grid Type Carbon was proved most effective of reinforcement.

  • PDF

The effect of magnetic field on a thermoelastic fiber-reinforced material under GN-III theory

  • Alzahrani, Faris S.;Abbas, Ibrahim A.
    • Steel and Composite Structures
    • /
    • v.22 no.2
    • /
    • pp.369-386
    • /
    • 2016
  • In this work, the two-dimensional generalized magneto-thermoelastic problem of a fiber-reinforced anisotropic material is investigated under Green and Naghdi theory of type III. The solution will be obtained for a certain model when the half space subjected to ramp-type heating and traction free surface. Laplace and exponential Fourier transform techniques are used to obtain the analytical solutions in the transformed domain by the eigenvalue approach. The inverses of Fourier transforms are obtained analytically. The results have been verified numerically and are represented graphically. Comparisons are made with the results predicted by the presence and absence of reinforcement and magnetic field.

Sensitivity Analysis for Determination of Series FACTS Location (직렬형 FACTS 기기 위치 선정을 위한 감도 해석)

  • Dosano, Jose Rodel;Song, Hwa-Chang;Chang, Byung-Hoon;Lee, Byong-Jun
    • Proceedings of the KIEE Conference
    • /
    • 2006.07a
    • /
    • pp.159-160
    • /
    • 2006
  • This paper discusses sensitivity analysis for determining adequate locations of series-type FACTS devices. The main objective of FACTS reinforcement is to alleviate line over-loadings against violation of thermal limits after disturbances. This paper, to obtain the information concerning series-type FACTS locations, proposes a formulation for the sensitivity of the PI (Performance Index) with respect to the variation of the branch parameters, and applies to 5-bus test system to show the effectiveness of the sensitivity.

  • PDF

Integral Bridge System with Geosynthetic-Reinforced Backfill

  • Tatsuoka, Fumio
    • Proceedings of the Korean Geotechical Society Conference
    • /
    • 2007.09a
    • /
    • pp.39-52
    • /
    • 2007
  • A new type bridge combining an integral bridge and a pair of geosynthetic-reinforced soil (GRS) retaining walls having full-height rigid (FHR) facings, called the GRS integral bridge, is proposed. The geosynthetic reinforcement layers are connected to the FHR facings (i.e., RC parapets) that are integrated with a girder without using any girder-support. GRS integral bridges are basically much more cost-effective in construction and long-term maintenance while having a much higher seismic stability than conventional-type bridges having a girder via movable and fixed supports on a pair of cantilever abutments. GRS integral bridges are better than bridges using GRS retaining walls as abutments and also than conventional integral bridges with unreinforced backfill. To validate the above, a series of static cyclic lateral loading tests of the facing and a series of shaking table tests were performed on smallscaled models of different bridge types.

  • PDF

Effect of Concrete Coating Materials for the Improvement of Concrete Durability (콘크리트 표면도장에 의한 내구성증진 효과)

  • 문한영;김성수;안태송;김홍삼
    • Proceedings of the Korea Concrete Institute Conference
    • /
    • 1999.04a
    • /
    • pp.433-436
    • /
    • 1999
  • Long-term durability of the reinforced concrete structures exposed to marine environment deteriorates seriously by the attack of the chloride ion from see water results in corrosion of steel reinforcement in concrete. Their coating effect is aluminum oxide-isocyanate-based coating material, resistance of chloride penetration, carbonation and freezing and thawing resistance were compared to acryl-based coating material and sealer type o waterproofing material. Aluminum oxide-isocyante-based and acryl-based coating material show higher resistance to chloride penetration and carbonation than the sealer type do waterproofing material and aluminum oxide-isocyanate-based coating resist about 99% of chloride penetration. Resultants to the accelerated test for freezing and thawing, coating concrete show higher resistance than non-coating concrete, respectively.

  • PDF

Compound waterproofing method of green roof using copper barrier sheet and recycled tire melting liquid waterproofing material that reinforced treatments are valve and glass fiber mesh. (알루미늄 판막과 유리섬유를 합지한 구리방근시트와 폐타이어 용융액상 도막방수재를 이용한 옥상녹화 복합방수공법)

  • Kim, Young chan;Cho, Il Kyu;choi, sung min;Oh, Sang Keun
    • Proceedings of the Korean Institute of Building Construction Conference
    • /
    • 2008.11a
    • /
    • pp.173-178
    • /
    • 2008
  • This is green roof bottom system which composed by aluminum valve and glass fiber together as major reinforcement, so the cooper sheet can have root proof, and using recycled tire gel-type membrane waterproofing system which dost not contains VOCs. The copper sheet reduce the plants' root growing, so it helpes to maintain the waterproofing layer and stability of root proofing. Gel type membrane waterproofing system can do waterproofing, stress dispersion, and reducing leakage expansion. So those two materials can help each other to make green roof bottom layer would have the stability and durability.

  • PDF