• Title/Summary/Keyword: Refractivity

Search Result 42, Processing Time 0.026 seconds

Analysis on Vehicle Tracking Error due to Radio Refraction (전파굴절에 의한 비행체 추적오차 분석)

  • Oh, Chang-Yul;Lee, Hyo-Keun;Oh, Seung-Hyeub
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.11A
    • /
    • pp.1078-1084
    • /
    • 2010
  • The tracking performance of a big parabola tracking antenna system for tracking and receiving of the signal from the vehicle is impacted by many factors of the internal and the external of the system. In this paper, we analyze the tracking error due to the radio refraction in the application of the tracking and positioning of the vehicle by using radio frequency. The real measurement data are used for the analysis which had been acquired by using GPS and the tracking systems of C- and S-band frequencies in NARO Space centre. To verify the correlation between the tracking errors measured and the radio refraction, we review the error factors and the accuracies of the tracking systems, and the characteristics of the refractivity. The analysis shows that there are angular errors which are due to the radio refraction and not to be neglected, compared to the accuracies of the tracking systems, in case of low elevation angle less than 10 degrees. Also, the tracking errors depend on the target altitude as well as the elevation angle for the case of the target in the troposphere. It is recommended to correct the tracking angle considering the target altitude and elevation angle for the precise target positioning.

Ionospheric Correction for retrieving atmospheric variables from GPS occultation data

  • Huang Cheng-Yung;Liou Yuei-An
    • Proceedings of the KSRS Conference
    • /
    • 2005.10a
    • /
    • pp.43-46
    • /
    • 2005
  • [1] There are systematical errors associated with ionospheric influence in retrieving key atmospheric parameters from radio occultation (RO) soundings. In order to obtain better-quality retrievals, we develop a new method, hereafter called National Central University Radio Occultation (NCURO) scheme, to reduce the ionospheric influence. The excess phase is divided into two parts, namely geometric excess length and path excess length (excess length along ray path due to refractivity effect). An excess phase equation is presented and implemented in the NCURO scheme Whose performance is evaluated through comparisons with model simulation and experimental data. The model simulation is based on the use of the ionospheric model 002001 and atmospheric model NRLMSISE-OO. Results show that the NCURO scheme significantly reduces the ionospheric influence at altitudes above 70 km as does the scheme presented in the literature, and provides better corrections for the atmospheric profile. INDEX TERMS: 2400 Ionosphere: Ionosphere; 6964 Radio Science: Radio wave propagation; 6969 Radio Science: Remote sensing.

  • PDF

Development of Integration System for Epitope Prediction (항원결정부위 예측을 위한 통합시스템 개발)

  • Jin, Hye Jeong;Lee, Jihoo;Lee, In Seoung;Kim, Hak Yong
    • Proceedings of the Korea Contents Association Conference
    • /
    • 2015.05a
    • /
    • pp.227-228
    • /
    • 2015
  • 질병 치료에 대한 패러다임이 과거 치료 위주에서 조기진단 및 예방의 개념으로 전환되고 있으며 진단용 마커와 단클론 항체 제작은 핵심 기술로 부각되고 있다. 현재까지의 항원결정부위(epitope) 예측은 단백질의 1차구조인 아미노산 배열 순서를 바탕으로 추출되어 진다. 하지만 항원결정부위는 수용성의 항체와 직접 결합하기 때문에 친수성 잔기가 차지하는 비율이 높아야 하며, 면역계가 쉽게 인지할 수 있도록 노출되어 있어야하고, 긴 선상의 폴리펩티드 단백질이 3차원 구조를 형성하기 위해 회전, 유연성 등이 요구된다. 따라서 한 가지 성질 중심으로 할 경우 오류가 나올 가능성이 있다. 이를 보완하기 위하여 본 연구에서는 친수성(hydrophilicity), 극성(polarity), 파묻힘성(buried residues), 접근성(accessibility), 회전성(${\beta}-turns$), 유연성(flexibility), 굴절성(refractivity) 등을 분석한 후 통합 예측시스템을 개발하였다. 이를 검증하기 위해 고양이 백혈병 바이러스의 항원결정부위를 예측해보았다.

  • PDF

Automatic measurement of gage block using digital image processing (디지탈 화상처리를 이용한 게이지 블록의 측정 자동화)

  • Ko, Y.U.;Suh, H.S.;Eom, T.B.
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.11 no.5
    • /
    • pp.56-65
    • /
    • 1994
  • We have carried out a research on automatic measurement of gage blocks below 250mm and then improved the accuracy of the system, and reduced the measurement time using image processing technique and computer interface. The accuracy of the system is (230+10330 $L^{2}$)$^{2}$ nm (L:m) with confidence level of 95%. We participated APMP gage block intercomparision-1993/1994. The 1st round intercomparision showed that the measured values of all 5 gage blocks were within 21 nm from average.

  • PDF

Electron density measurment in arc discharge using Mach-Zenhder interferometer (Mach-Zenhder 간섭계를 이용한 아크방전 중의 전자밀도 측정)

  • Cho, J.H.;Roh, Y.S.;Lee, H.S.
    • Proceedings of the KIEE Conference
    • /
    • 1996.07c
    • /
    • pp.1898-1900
    • /
    • 1996
  • The Laser aided diagnostic method makes it possible to diagnose plasma characteristics which have never been done by other one. The aim of this study is to measure the electron density profile of an arc plasma by Mach-Zenhder interferometer. The two laser beams (He-Ne and Argon Lasers), which are different in wavelength, pass across an arc plasma and meet a change of refractivity which makes fringe shifts. From this effects we could find densities of electron and neutral particle.

  • PDF

Open Loop Technique in FORMOSAT-3/COSMIC mission

  • Yeh, Wen-Hao;Chiu, Tsen-Chieh;Liou, Yuei-An;Huang, Cheng-Yung
    • Proceedings of the KSRS Conference
    • /
    • 2007.10a
    • /
    • pp.394-396
    • /
    • 2007
  • Radio occultation (RO) technique has been used in planetary science since 1960s. When signal goes through atmosphere, it is refracted due to the gradient of atmospheric refractivity. In 1995, the first low earth orbit (LEO) satellite, MicroLab-1, was launched to conduct RO mission. It receives the signal from global positioning system (GPS) satellites. After MicroLab-1, other RO missions, such as CHAMP, SAC-C, and GRACE, are executed in several years later. In 2006, Taiwan launched six LEO satellites for RO mission. The mission name is Constellation Observing System for Meteorology, Ionosphere and Climate (COSMIC). Under some abnormal situations, multipath and strong fluctuation in phase and amplitude of the signal appear in moist troposphere. Therefore, open loop (OL) technique has been applied to replace traditional phase lock loop (PLL) technique. In this paper, we will summarize the retrieval processing procedure and discuss the advantages and disadvantages of OL technique.

  • PDF

Optical and Electrical Properties of $Ti_xSi_{1-x}O_y$ Films

  • Lim, Jung-Wook;Yun, Sun-Jin;Kim, Je-Ha
    • ETRI Journal
    • /
    • v.31 no.6
    • /
    • pp.675-679
    • /
    • 2009
  • $Ti_xSi_{1-x}O_y$ (TSO) thin films are fabricated using plasma-enhanced atomic layer deposition. The Ti content in the TSO films is controlled by adjusting the sub-cycle ratio of $TiO_2$ and $SiO_2$. The refractive indices of $SiO_2$ and $TiO_2$ are 1.4 and 2.4, respectively. Hence, tailoring of the refractivity indices from 1.4 to 2.4 is feasible. The controllability of the refractive index and film thickness enables application of an antireflection coating layer to TSO films for use as a thin film solar cell. The TSO coating layer on an Si wafer dramatically reduces reflectivity compared to a bare Si wafer. In the measurement of the current-voltage characteristics, a nonlinear coefficient of 13.6 is obtained in the TSO films.

Interrelation of Retention Factor of Amino-Acids by QSPR and Linear Regression

  • Lee, Seung-Ki;Polyakova, Yulia;Row, Kyung-Ho
    • Bulletin of the Korean Chemical Society
    • /
    • v.24 no.12
    • /
    • pp.1757-1762
    • /
    • 2003
  • The interrelation between retention factors of several L-amino acids and their physico-chemical and structural properties can be determined in chromatographic research. In this paper we describe a predictor for retention factors with various properties of the L-amino acids. Eighteen L-amino acids are included in this study, and retention factors are measured experimentally by RP-HPLC. Binding energy ($E_b$), hydrophobicity (log P), molecular refractivity (MR), polarizability (${\alpha}$), total energy ($E_t$), water solubility (log S), connectivity index (${\chi}$) of different orders and Wiener index (w) are theoretically calculated. Relationships between these properties and retention factors are established, and their predictive and interpretive ability are evaluated. The equation of the relationship between retention factors and various descriptors of L-amino acids is suggested as linear and multiple linear form, and the correlation coefficients estimated are relatively higher than 0.90.

A Study on the Effect of Atmosphere on the Space Surveillance Radar (우주감시레이다에 대한 지구 대기권 영향 분석 연구)

  • Moon, Hyun-Wook;Choi, Eun-Jung;Lee, Jonghyun;Yeum, Jaemeung;Kwon, Sewoong;Hong, Sungmin;Cho, Sungki;Park, Jang-Hyun;Jo, Jung Hyun
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.29 no.8
    • /
    • pp.648-659
    • /
    • 2018
  • In this study, both the altitude error due to the refraction and the range error due to the delay in the ionosphere with respect to the frequency are extracted according to the radar elevation to analyze the effect of atmosphere on the space surveillance radar. To achieve this, the radio refractivity profile is modeled using the measured data from domestic weather stations. Then, the altitude-error due to the refraction is extracted using the ray tracing method, and the range error in the ionosphere is extracted according to the frequency. Further, considerations for radar design with respect to the radar error characteristics are discussed based on the abroad space surveillance radar and proposed domestic space surveillance radar. This analysis of the error characteristics is expected to be utilized for the determination of radar location, range of steering, and frequency in the space surveillance radar design.

Range of physicochemical parameters for active ingredients of herbicides (제초제의 활성 성분에 대한 물리-화학 파라미터의 범위)

  • Sung, Nack-Do;Song, Seon-Seob
    • The Korean Journal of Pesticide Science
    • /
    • v.7 no.1
    • /
    • pp.58-65
    • /
    • 2003
  • Various physicochemical parameters for the active ingredients of 245 herbicides were calculated to develope a diagnosis and estimation system for utility as herbicide. The range of physico-chemical parameters for each inhibitors of photo system II (H1), acetolactate synthase (ALS) (H2) and herbicides were confirmed. The distribution ranges of 85% dependence for each physicochemical parameters were Obs.logP :$-0.90\sim4.50$, dipol moment: $1.80\sim12.22$ (debye), molecular refractivity: $53.0\sim104.0(cm^3/mol)$, polarizability: $19.0\sim37.0(\AA^3)$, HOMO energy: $-9.98\sim-7.34$ (eV), LUMO energy:$-2.76\sim0.40$ (eV), Van der Waals molecular volumes: $558.0\sim995.0(cm^3)$, molecular weight: $202.0\sim430.0$ (amu) and surface areas (Grids): $194.0\sim356.0(\AA^2)$, hydration energy: $-10.16\sim114.7$ Kcal/mol, respectively. It is suggested that MR and polarizability constants will be able to distinguish between herbicides and medicinal drugs. Results revealed that various compounds based on the range of physicochemical parameters of herbicides could be diagnosed and estimated.