• Title/Summary/Keyword: Refraction Rate

Search Result 45, Processing Time 0.022 seconds

Shoreline Change Model in Haeundae Beach (해운대 해빈의 해안선변형 예측 모형)

  • 박일흠;이종섭
    • Journal of Korean Society of Coastal and Ocean Engineers
    • /
    • v.1 no.1
    • /
    • pp.50-62
    • /
    • 1989
  • Shoreline change of Haeundae beach was predicted by one-line model considering interaction of seawalls and longshore variation of wave height . Wave deformation was calculated by combined wave refraction-diffraction model . In this shoreline change model, empirical constants and offshore sediment transport rate are treated as calibration parameters, and the calculated results are in good agreement with the observed data.

  • PDF

A study of Nickel Oxide thin film deposited by DC magnetron and RF sputtering method (DC magnetron 방법과 RF 스퍼터링 방법으로 제작된 Nickel Oxide 박막의 특성 연구)

  • Choi, Kwang-Nam;Park, Jun-Woo;Baek, Seoung-Ho;Lee, Ho-Sun;Kwak, Sung-Kwan;Chung, Kwan-Soo
    • Proceedings of the IEEK Conference
    • /
    • 2007.07a
    • /
    • pp.441-442
    • /
    • 2007
  • We deposited nickel oxide(NiO) thin films on silicon(Si) substrates at Room temperature and $500^{\circ}C$ using a nickel target by reactive DC and RF sputtering. In addition, we anneal to NiO thin films deposited at room temperature. Using spectroscopic eillipsometry, we obtained optical characteristics of every films. We discussed relations of the optical and structural properties of NiO thin films with the oxygen flow rate, substrate temperature and annealing temperatures. Refraction was decreased and defect was increased when NiO thin films was annealed. We also analyzed the electrical characteristics of NiO films which deposited DC and RF sputtering method.

  • PDF

Container Identifier Recognition System for GATE Automation (게이트 자동화를 위한 컨테이너 식별자 인식 시스템)

  • 유영달;강대성
    • Journal of Korean Port Research
    • /
    • v.12 no.2
    • /
    • pp.225-232
    • /
    • 1998
  • Todays, the efficient management of container has not been realized in container terminal, because of the excessive quantity of container transported and manual system. For the efficient and automated management of container in terminal, the automated container identifier recognition system in terminal is a significant problem. However, the identifier recognition rate is decreased owing to the difficulty of image preprocessing caused the refraction of container surface, the change of weather and the damaged identifier characters. Therefore, this paper proposes more accurate system for container identifier recognition as suggestion of LSPRD(Line-Scan Proper Region Detection) for stronger preprocessing against external noisy element and MBP(Momentum Back-Propagation) neural network to recognize the identifier.

  • PDF

Research Trend of OCA (Optically Clear additive) for Display Panel by Analysis of Patent and Papers Publication (특허 및 논문 분석을 통한 디스플레이용 접착제의 기술경쟁력 분석)

  • Woo, Chang Hwa
    • Journal of the Semiconductor & Display Technology
    • /
    • v.17 no.3
    • /
    • pp.75-84
    • /
    • 2018
  • According to IHS, the overall display market is expected to grow at an average annual rate of 6% from $ 104 billion in 2016, to $ 138 billion in 2021. Among them, the OLED display panel will grow from $ 15 billion to $ 41 billion over the same period, forecasting a high annual growth rate of 22%. However, the refraction index, light leakage, bubble generation, adhesion deterioration, peeling phenomenon, moisture resistance, light transmittance, low turbidity. OCA (optically clear adhesive), which solves problems such as improving the resistance of the conductive film, is largely dependent on imported products. In addition, in 2016, the world market is worth KRW4.3 trillion, and the adhesive market has a large market effect. In this study, we tried to analyze the technical competitiveness of patent and thesis by classifying OCA (optically clear adhesive, optical adhesive) for display panel by curing method. As a result of the study, the amount of patents and papers in Korea was found to be superior to other competitors, but the quality level was low. In particular, it was found that the achievements of the papers in the hot melt field are lacking and the government should expand its support.

Numerical Simulation and PIV Measurement on the Internal Flow in a Centrifugal Mini Pump at Low Flow Rate Conditions

  • Yuan, Hui-Jing;Shao, Jie;Cao, Guang-Jun;Liu, Shu-Hong;Wu, Yu-Lin
    • Proceedings of the Korean Society of Propulsion Engineers Conference
    • /
    • 2008.03a
    • /
    • pp.775-780
    • /
    • 2008
  • This paper reports on the internal flow of a centrifugal mini pump working at the low flow rate operating conditions. The RNG $\kappa-\varepsilon$ turbulence model was employed to simulate the three-dimensional turbulent flow in the pump. To examine and certify the simulation results, a transparent acrylic centrifugal mini pump model which is suitable for PIV measurement has been developed. The tongue region and the passages region between blades were investigated using PIV. In order to eliminate the effect of refraction on the area closed to the wall and increase the measurement accuracy, the fluorescent particles were scatted into the working fluid with the tracing particles. It is found from the calculation and PIV measurement results that there is a large area of recirculation flow near the tongue at low flow rate operating conditions. The computationally predicted water head using the $\kappa-\varepsilon$ turbulence model at low flow rate operating conditions are in very good agreement with the experimentally measured water head and the mean velocity distributions at investigation area obtained by PIV and calculation showed a satisfactory agreement as well. Meanwhile, the results of PIV measurements show that the flow status in one passage is different to another. And for capturing the internal flow detail information, the $\kappa-\varepsilon$ turbulence model is not very suitable.

  • PDF

The Investigation of the Changes of Visual Problems in VDT Workers (VDT 작업 전·후 시기능 변화)

  • Gang, Myoung Jin;Choe, Oh Mok
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.7 no.2
    • /
    • pp.33-39
    • /
    • 2002
  • The purpose of this study is to evaluate the effects of continuing work on VDT(video display terminal). Therefore, we examined visual fatigue by a questionnaire and measured frequency of blinking, tear film break-up time(BUT), height of palpebral fissure, visual acuity, refraction with retinoscopy and accommodation before and after two hour long VDT work. For the ocular symptoms, the greatest number was tired eyes accounting for 34%. In the visual symptoms, blurred vision was the highest rate of 83% and in case of systemic symptoms, shoulder pain was 38% marked top ranking but other symptoms were also distributed similar rate. The frequency of blinking during VDT work decreased significantly comparing with the one at rest. The average frequency of blinking is 8/min during VDT work and 22/min at rest. The BUT measured immediately after VDT work decreased much more than in the resting state. The average BUT was 7sec immediately after VDT work and 12sec at rest. The height of palpebral fissure during VDT work increased significantly comparing with the value at rest. The average height of palpebral fissure was 7.69mm at rest and 9.04mm during VDT work. The average visual acuity decreased almost 9.5% from 0.63 to 0.57, but refraction with retinoscopy increased about 0.28D to the direction of myopic shift. The amplitude of accommodation decreased approximately 1.49D from 7.98D to 6.49D and this resulted from the prolongation of near point of accommodation. Near point of convergence also was prolongated from 9.45cm to 10.30cm after VDT work.

  • PDF

Relationship on the Refractive Status of the High School 3rd Grade Students with Subnormal Visual Acuity in Gwangju Metropolitan City (광주지역 고등학교 3학년생의 비정시안의 굴절상태에 대한 고찰)

  • Yoon, Young;Ryu, Geun-Chang
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.12 no.3
    • /
    • pp.105-110
    • /
    • 2007
  • To investigate the ametropia and refractive error of 222 ametropic eyes of the 111 high school students in Gwangju Metropolitan City, the visual acuity test was performed by the object and subject method. 85% of the eye types were positive for myopia, 14% for emmetropia, and 1% for hyperopia, respectively. 38% of the abnormal refraction eyes were positive for simple myopia, 4% for myopia simple astigmatism, 56% for myopia compound astigmatism, and 0% for simple hyperopia, 0% for hyperopia simple astigmatism, 2% for hyperopia compound astigmatism, 0% for mixed astigmatism, respectively. 92% of the axes fo astigmatism were for astigmatism with-the-rule, 6% for astigmatism against-the rule, 2% for astigmatism oblique, respectively. As for the astigmatic power, 0.50 < cylinder < 1.00D was 68%, 1.00 < cylinder < 2.00D was 25%, and anything over the 2.00 cylinder D was 7%. As for the equivalent spheric power of myopic abnormal refraction eyes, -0.50 < spheric equivalent < -2.00D was 26%, -2.00D < spheric equivalent < -6.00D was 55% and anything over the -6.00D was 19%. The rate of wearing glasses was 74%. It increases compared to 20 years ago. 91% of the eye test place was the optical shop, 9% the eye doctor hospital. 80% of the students need to change their optical lenses because spherical equivalent power was over 0.50D.

  • PDF

Changes in Accommodative Function after VDT Work (VDT 작업 후의 조절기능 변화)

  • Seo, Eun-Sun
    • Journal of Korean Ophthalmic Optics Society
    • /
    • v.17 no.3
    • /
    • pp.285-291
    • /
    • 2012
  • Purpose: This study was conducted to research any effect on visual function related to accommodation by VDT work. Methods: The refraction power, accommodative lag, accommodative facility, relative accommodation, amplitude of accommodation and blink rate were measured before and after VDT work for 2 hours on 48 university students (16 males and 32 females), without abnormal accommodative function and systemic and ocular disease, who had never undergone corrective eye surgery. All examinations were performed with distant refraction, and a survey was conducted on the items related to subjective symptoms of VDT syndrome. Results: After 2 hours of VDT work, refractive power increased by 0.23 D, the amount of change in accommodative lag were $0.17{\pm}0.42D$ in the right eye and $0.23{\pm}0.47D$ in the left eye (t=2.26, p=0.03). There were statistically significant differences. Both the accommodative facility and relative accommodation and amplitude of accommodation were decreased after work. However, blink rate were increased. After VDT work, 33.4% of the subjects showed subjective symptoms of asthenopia and 33.3% of them showed shoulder pain. Conclusions: As a result, the accommodative lag increased in response to the two hours of VDT work, and overall accommodative functions were decreased. In addition, as symptoms of providing visual strain, asthenopia showed the most prominent subjective symptoms.

Acoustical Anisotropy Evaluation of Pure Titanium plate Using Neural Network (신경회로망을 이용한 순 티타늄판재의 음향이방성 평가)

  • Park, Hee-Dong;Yun, In-Sik;Yi, Won
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.28 no.9
    • /
    • pp.1103-1109
    • /
    • 2011
  • This research quantitatively confirmed an acoustical anisotropy that exists in a pure titanium plate from the signal of ultrasonic flow detection and suggested a new way to evaluate the acoustical anisotropy by inputting acquired characteristic of ultrasound signal into the neutral network. Using the fact with the suggested method that the characteristic of ultrasound signal is shown differently depending on the pure titanium plate's rolling direction, the neural network was constructed by extracting the characteristic that can decide each direction of $0^{\circ}$, $45^{\circ}$, and $90^{\circ}$ with waveform analysis program. As a result of inputting the characteristic of ultrasound signal acquired from a random rolling direction into the neural network that was built like this, it showed a pattern recognition rate higher than 95% on directions of $0^{\circ}$, $45^{\circ}$, $90^{\circ}$.

Numerical Study on the Wireless Communication at 550[nm], 850[nm] and 1550[nm] Wavelength LD in Fog and Pointing Error using Cassegrain Optics (카세그레인 광학계를 사용한 광무선통신 시스템에서 550[nm], 850[nm] 및 1550[nm]의 광 파장에 대한 안개 및 포인팅의 에러의 영향에 대한 해석)

  • Hong, Kwon-Eui
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.22 no.12
    • /
    • pp.164-175
    • /
    • 2008
  • Atmospheric effects on laser beam propagation can be broken down into two categories: attenuation of the laser power and fluctuation of laser power due to laser beam deformation. Attenuation consists of scattering of the laser light photons by the fog. Laser beam deformation occurs because of small-scale dynamic changes in the index of refraction of the atmosphere. This causes pointing error. In order to analyse these effect on optical wireless communication system, in this paper uses cassegrain optics as a transmitting and receiving telescope, AID as a detecting device and ill as a light source. The signal modulating and demodulating method is a IM/DD. I show the effects of fog and pointing error and calculate the possible communication distance for BER is $10^{-9}$.