• Title/Summary/Keyword: Reference weight

Search Result 789, Processing Time 0.026 seconds

Empirical and Numerical Analyses of a Small Planing Ship Resistance using Longitudinal Center of Gravity Variations (경험식과 수치해석을 이용한 종방향 무게중심 변화에 따른 소형선박의 저항성능 변화에 관한 연구)

  • Michael;Jun-Taek Lim;Nam-Kyun Im;Kwang-Cheol Seo
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.29 no.7
    • /
    • pp.971-979
    • /
    • 2023
  • Small ships (<499 GT) constitute 46% of the existing ships, therefore, it can be concluded that they produce relatively high CO2 gas emissions. Operating in optimal trim conditions can reduce the resistance of the ship, which results in fewer greenhouse gases. An affordable way for trim optimization is to adjust the weight distribution to obtain an optimum longitudinal center of gravity (LCG). Therefore, in this study, the effect of LCG changes on the resistance of a small planing ship is studied using empirical and numerical analyses. The Savitsky method employing Maxsurf resistance and the STAR-CCM+ commercial computational fluid dynamics (CFD) software is used for the empirical and numerical analyses, respectively. Finally, the total resistance from the ship design process is compared to obtain the optimum LCG. To summarize, using numerical analysis, optimum LCG is achieved at the 46.2% length overall (LoA) at Froude Number 0.56, and 43.4% LoA at Froude Number 0.63, which provides a significant resistance reduction of 41.12 - 45.16% compared to the reference point at 29.2% LoA.

Shielding Design Optimization of the HANARO Cold Neutron Triple-Axis Spectrometer and Radiation Dose Measurement (냉중성자 삼축분광장치의 차폐능 최적화 설계 및 선량 측정)

  • Ryu, Ji Myung;Hong, Kwang Pyo;Park, J.M. Sungil;Choi, Young Hyeon;Lee, Kye Hong
    • Journal of Radiation Protection and Research
    • /
    • v.39 no.1
    • /
    • pp.21-29
    • /
    • 2014
  • A new cold neutron triple-axis spectrometer (Cold-TAS) was recently constructed at the 30 MWth research reactor, HANARO. The spectrometer, which is composed of neutron optical components and radiation shield, required a redesign of the segmented monochromator shield due to the lack of adequate support of its weight. To shed some weight, lowering the height of the segmented shield was suggested while adding more radiation shield to the top cover of the monochromator chamber. To investigate the radiological effect of such change, we performed MCNPX simulations of a few different configurations of the Cold-TAS monochromator shield and obtained neutron and photon intensities at 5 reference points just outside the shield. Reducing the 35% of the height of the segmented shield and locating lead 10 cm from the bottom of the top cover made of polyethylene was shown to perform just as well as the original configuration as radiation shield excepting gamma flux at two points. Using gamma map by MCNPX, it was checked that is distribution of gamma. Increased flux had direction to the top and it had longer distance from top of segmented shield. However, because of reducing the 35% of the height, height of dissipated gamma was lower than original geometry. Reducing the 35% of the height of the segmented shield and locating lead 10cm from the bottom of the top cover was selected. After changing geometry, radiation dose was measured by TLD for confirming tester's safety at any condition. Neutron(0.21 ${\mu}Svhr^{-1}$) and gamma(3.69 ${\mu}Svhr^{-1}$) radiation dose were satisfied standard(6.25 ${\mu}Svhr^{-1}$).

Quantifying Uncertainty of Vitamin C Determination in Infant Formula by Indophenol Titration Method (인도페놀 적정법에 의한 성장기용조제식 중 비타민 C 함량분석의 측정불확도 산정)

  • Jun, Jang-Young;Kwak, Byung-Man;Ahn, Jang-Hyuk;Kong, Un-Young
    • Korean Journal of Food Science and Technology
    • /
    • v.37 no.3
    • /
    • pp.352-359
    • /
    • 2005
  • Uncertainty involved during determination of vitamin C content in infant formula was quantified by indophenol titration method. Uncertainty sources in measurand, such as purity, weight, final volume of standard, volume of standard solution used for titration, sample weight, final volume of sample, extraction solution used for titration, titration of extraction solution and standard solution by indophenol solution were identified and used as parameters for combined standard uncertainty based on Guide to the expression of uncertainty in measurement (GUM) and Draft EURACHEM/CITAC Guide. Uncertainty parameters of each source in measurand were identified as resolution, reproducibility and stability of chemical balance, standard material purity, repeatability, reproducibility, end point of titration, 1 mL pipet, 5 mL autopipet, and 100 mL mass flask. Each uncertainty component was evaluated by types A and B and included to calculate combined uncertainty. Analytical test result for traceability under laboratorial conditions using Certified Reference Material (CRM) test was certified as $108.4{\pm}1.7mg/100g$, which was within CRM certification range of $114.6{\pm}6.6mg/100g$. Uncertainty test result of vitamin C content of 5 g sampling was $56.7{\pm}2.44mg/100g$. Uncertainty could be reduced by identification of uncertainty sources and components related with vitamin C determination by indophenol titration method and by decreasing uncertainty sources and components.

Nutritional Status of Continuous Ambulatory Peritoneal Dialysis Patients (지속성복막투석 환자의 영양상태에 관한 연구)

  • Park, Jin-Kyung;Son, Sook-Mee
    • Journal of Nutrition and Health
    • /
    • v.39 no.7
    • /
    • pp.624-640
    • /
    • 2006
  • Dialysis patients are at risk of malnutrition not only because of losses of nutrients during peritoneal dialysis but also because of anorexia that results in inadequate nutrient intakes. The aim of this study was to estimate the nutritional status of 154 patients receiving continuous ambulatory peritoneal dialysis (CAPD), especially focused on protein-energy malnutrition and vitamin and mineral status. The mean age of the subjects was $5.12\;{\pm}\;12.4\;y$ with educational years of $12.3\;{\pm}\;0.4\;y$ for male and $9.6\;{\pm}\;0.4\;y$ for female. The mean duration of dialysis was $22.7\;{\pm}\;21.7\;mo$. The causes of renal failure included diabetes (32.7), chronic glomerulonephritis (15.0%), and hypertension (8.5%). The main complications associated with chronic renal failure were hypertension (86.1%), diabetes (35.4%) and liver disease (9.0%). The mean daily energy intake was $1216.8\;{\pm}\;457.3\;kcal$ and increased to $1509.2\;{\pm}\;457.2\;kcal$ when added with the energy from dextrose in dialysate. The latter was still much lower than estimated energy requirement but energy intake per kg of body weight (28.1 kcal/1 g) was within the range of that recommended for CAPD patients' diet therapy (25 - 30 kcal/kg). The average daily intake of protein was $49.2\;{\pm}\;25.1\;g$ with 37.6% of the patients showing their intakes less than Estimated Average Requirement. The average protein intake per kg of weight was 0.9 g/kg, which is less than that recommended for CAPD patients (1.2-1.5g/kg) with mean serum albumin level $3.2\;{\pm}\;0.5\;g/dl$. The proportion of the patients with dietary calcium intake less than EAR was 90.9%, but when added with supplementary calcium (phosphorus binder), most patients showed their total calcium intake between EAR and UL. Fifty percent of the patients were observed with dietary iron intake less than EAR, however most patients revealed their total iron intake with supplementation above UL. The addition of folic acid with supplementation increased mean total folic intake to $1126.0\;{\pm}\;152.4\;{\mu}g$ and ninety eight percent of the subjects showed their total folic acid intake above UL. The prevalence of anemia was 83.1 % assessed with hemoglobin level, even with high intakes of iron with supplementation. Thirty four percent of the patients showed their fasting blood glucose was not under control $(\geq\;126\;mg/dl)$ even with medication or insulin probably due to dextrose from dialysate. The mean blood lipid levels were within the reference levels of hyperlipidemia, but with 72.1 % of the patients showing lower HDL-C. In conclusion, Fairly large proportion of the patients were observed with protein malnutrition with low intake of protein and serum albumin level. Few patients showed their vitamins and minerals intake less than EAR with supplementation. For iron and folic acid, their intakes were increased to above UL for large proportion of he patients. However, more than eighty percent of the patients were still anemic associated with decreased renal function. The serum blood glucose and lipid level were not under control for some patients with medication. It seems that supplementation and medications that patients are taking should be considered for dietary consulting of CAPD patients.

Comparison of Reconstruction Methods after Distal Gsstrectomy for Gastric Carcinoma in Terms of the Long Term Physiologic Function and Nutritional Status; Billroth I Gastroduodenostomy versus Roux-en Y Gastrojejunostomy (수술 후 장기적인 생리적 기능과 영양적 측면에서 본 원위부위절제술 후 재건술식의 비교; Billroth I 위십이지장문합술과 Roux-en Y 위공장문합술의 비교)

  • Jeong, Oh;Oh, Sung-Tae;Yuk, Jung-Hwan;Choi, Ji-Eun;Kim, Kab-Jung;Lim, Jung-Taek;Park, Gun-Chun;Kim, Byung-Sik
    • Journal of Gastric Cancer
    • /
    • v.7 no.2
    • /
    • pp.88-96
    • /
    • 2007
  • Purpose: The only curative treatment for gastric carcinoma is surgery and it is still under debate which reconstruction method is better after performing gastrectomy for gastric carcinoma. The typical reconstruction methods after distal gastrectomy are Billroth I, Billroth II and Roux-en Y reconstruction. Yet it is difficult to compare these methods and not so much is known about which reconstruction is better in terms of the physiologic and nutritional function. With this background, we compared two reconstruction methods after distal gastrectomy (Billroth I versus Roux-en Y reconstruction) in terms of the long term physiologic function and nutritional status to create a reference for selecting reconstruction methods after distal gastrectomy. Materials and Methods: Between 1999 and 2002, 663 patients who underwent distal gastrectomy for early gastric carcinoma filled out questionnaires every six months after operation, and these questionnaires evaluated the physiologic function. To evaluate their nutritional status, blood tests were performed every six months to check their albumin, protein and hemoglobin levels, and we checked the body weight every 6 months as well. Results: The total score of the 15 questions on the questionnaire concerned with the physiologic function showed no difference between the two groups at every evaluation time, and both groups showed very low total scores, indicating tolerable physiologic function after operation. When comparing each question between two the groups, only symptoms of regurgitation and food passage showed a difference between the two groups, showing that the Roux-en Y group had better function in terms of these two symptoms. The Billroth I group showed a better nutrition status, indicating that the level of albumin, protein and hemoglobin were higher in the Billroth I group, with statistical significance. Body weight loss was severe in the Roux-en Y group. Conclusion: The physiologic function is slightly better in the Roux-en Y group in terms of some symptoms such as regurgitation and food passage. However, the nutritional status is better in the Billroth I group. In conclusion, because we cannot definitely ascertain which reconstruction is better when we consider both the physiologic and nutritional functions, it is reasonable that surgeon should choose reconstruction methods according to their experience and preference.

  • PDF

Effect of the Dose Reduction Applied Low Dose for PET/CT According to CT Attenuation Correction Method (PET/CT 저선량 적용 시 CT 감쇠보정법에 따른 피폭선량 저감효과)

  • Jung, Seung Woo;Kim, Hong Kyun;Kwon, Jae Beom;Park, Sung Wook;Kim, Myeong Jun;Sin, Yeong Man;Kim, Yeong Heon
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.18 no.1
    • /
    • pp.127-133
    • /
    • 2014
  • Purpose: Low dose of PET/CT is important because of Patient's X-ray exposure. The aim of this study was to evaluate the effectiveness of low-dose PET/ CT image through the CTAC and QAC of patient study and phantom study. Materials and Methods: We used the discovery 710 PET/CT (GE). We used the NEMA IEC body phantom for evaluating the PET data corrected by ultra-low dose CT attenuation correction method and NU2-94 phantom for uniformity. After injection of 70.78 MBq and 22.2 MBq of 18 F-FDG were done to each of phantom, PET/CT scans were obtained. PET data were reconstructed by using of CTAC of which dose was for the diagnosis CT and Q. AC of which was only for attenuation correction. Quantitative analysis was performed by use of horizontal profile and vertical profile. Reference data which were corrected by CTAC were compared to PET data which was corrected by the ultra-low dose. The relative error was assessed. Patients with over weighted and normal weight also underwent a PET/CT scans according to low dose protocol and standard dose protocol. Relative error and signal to noise ratio of SUV were analyzed. Results: In the results of phantom test, phantom PET data were corrected by CTAC and Q.AC and they were compared each other. The relative error of Q.AC profile was been calculated, and it was shown in graph. In patient studies, PET data for overweight patient and normal weight patient were reconstructed by CTAC and Q.AC under routine dose and ultra-low dose. When routine dose was used, the relative error was small. When high dose was used, the result of overweight patient was effectively corrected by Q.AC. Conclusion: In phantom study, CTAC method with 80 kVp and 10 mA was resulted in bead hardening artifact. PET data corrected by ultra- low dose CTAC was not quantified, but those by the same dose were quantified properly. In patients' cases, PET data of over weighted patient could be quantified by Q.AC method. Its relative difference was not significant. Q.AC method was proper attenuation correction method when ultra-low dose was used. As a result, it is expected that Q.AC is a good method in order to reduce patient's exposure dose.

  • PDF

Compositional Variation of Arsenopyrites in Arsenic and Polymetallic Ores from the Ulsan Mine, Republic of Korea, and their Application to a Geothermometer (울산광산산(蔚山鑛山産) 유비철석(硫砒鐵石)의 조성변화(組成變化) 및 지질온도계(地質溫度計)에 대(對)한 적용(適用))

  • Choi, Seon-Gyu;Chung, Jae-Ill;Imai, Naoya
    • Economic and Environmental Geology
    • /
    • v.19 no.3
    • /
    • pp.199-218
    • /
    • 1986
  • Arsenopyrite in arsenic and polymetallic ores from calcic Fe-W skarn deposit of the Ulsan mine, Republic of Korea, has been investigated by means of electron microprobe analysis and X-ray diffractometry. As a result, it is revealed that the Ulsan arsenopyrite may be classified into the following three species with different generation on the basis of its mode of occurrence, chronological order during polymetallic mineralization and chemical composition; arsenopyrites I, II and III. 1) Arsenopyrite I-(Ni, Co)-bearing species belonging to the oldest generation, which has crystallized together with (Ni, Co)-arsenides and -sulpharsenides in the early stage of polymetallic mineralization. In rare cases, it contains a negligible amount of antimony. It occurs usually as discrete grains with irregular outline, showing rarely subhedral form, and is diffused in skarn zone. The maximum contents of nickel and cobalt are 10.04 Ni and 2.45 Co (in weight percent). Occasionally, it shows compositional zoning with narrow rim of lower (Ni+Co) content. 2) Arsenopyrite II-arsenian species, in which (Ni+Co) content is almost negligible, may occur widely in arsenic ores, and its crystallization has followed that of arsenopyrite I. It usually shows subhedral to euhedral form and is closely associated with $l{\ddot{o}}llingite$, bismuth, bismuthinite, chalcopyrite, sphalerite, bismuthian tennantite, etc. It is worthy of note that arsenopyrite II occasionally contains particles consisting of both bismuth and bismuthinite. 3) Arsenopyrite III-(Ni, Co)-free, S-excess and As-deficient species is close to the stoichiometric composition, FeAsS. It occurs in late hydrothermal veins, which cut clearly the Fe-W ore pipe and the surrounding skarn zone. It shows euhedral to subhedral form, being extremely coarse-grained, and is closely associated with pyrite, "primary" monoclinic pyrrhotite, galena, sphalerite, etc. Among three species of the Ulsan arsenopyrite, arsenopyrite I does not serve as a geothermometer, because (Ni+Co) content always exceeds 1 weight percent. In spite of the absence of Fe-S minerals as sulphur-buffer assemblage, the presence of $Bi(l)-Bi_2S_3$ sulphur-buffer enables arsenopyrite II to apply successfully to the estimation of either temperature and sulphur fugacity, the results are, $T=460{\sim}470^{\circ}C$, and log $f(S_2)=-7.4{\sim}7.0$. With reference to arsenopyrite III, only arsenopyrite coexisting with pyrite and "primary" monoclinic pyrrhotite may serve to restrict the range of both temperature and sulphur fugacity, $T=320{\sim}440^{\circ}C$, log $f(S_2)=-9.0{\sim}7.0$. These temperature data are consistent with those obtained by fluid inclusion geothermometry on late grandite garnet somewhat earlier than arsenopyrite II. At the beginning of this paper, the geological environments of the ore formation at Ulsan are considered from regional and local geologic settings, and physicochemical conditions are suspected, in particular the formation pressure (lithostatic pressure) is assumed to be 0.5kb (50MPa). The present study on arsenopyrite geothermometry, however, does not bring about any contradictions against the above premises. Thus, the following genetical view on the Ulsan ore deposit previously advocated by two of the present authors (Choi and Imai) becomes more evident; the ore deposit was formed at shallow depth and relatively high-temperature with steep geothermal gradient-xenothermal conditions.

  • PDF

Elucidation of Dishes High in N-Nitrosamines Using Total Diet Study Data (총식이조사 자료를 이용한 음식별 니트로사민 함량 분포 규명)

  • Choi, Seul Ki;Lee, Youngwon;Seo, Jung-eun;Park, Jong-eun;Lee, Jee-yeon;Kwon, Hoonjeong
    • Journal of Food Hygiene and Safety
    • /
    • v.33 no.5
    • /
    • pp.361-368
    • /
    • 2018
  • N-nitrosamines are probable or possible human carcinogens, which are produced by the reaction between secondary amines and nitrogen oxide in the acidic environment or by heating. Common risk assessment procedure involves the comparison between exposures expressed in the unit, mg/kg body weight/day and the Health-Based Reference dose expressed in the same unit. This procedure is suitable for the policy decision-making and is considered as inappropriate for the consumers to get information about their dietary decision-making. Therefore, the distributions of NDMA (N-nitrosodimethylamine), NDBA (N-nitrosodibutylamine), the six N-nitrosamines (NDMA, NDBA, NDEA (N-nitrosodiethylamine), NPYR (N-nitrosopyrrolidine), NPIP (N-nitrosopiperidine), and NMOR (N-nitrosomorpholine) in the menus grouped based on the presence of main ingredients and cooking methods were analyzed to generate consumer-friendly information regarding food contaminants. Recipes and intakes were taken from 2014 to 2016 KNHANES (The Korean National Health and Nutrition Examination Survey) and only the data from ages of 7 years or older were used. The contamination data were collected from the 2014~2016 Total Diet Study and all the analysis were performed using R software. Rockfish, eel, anchovy broth and pollock were mainly exposed to N-nitrosamines. In terms of cooking methods, soups and stews appeared to contain the highest amount of N-nitrosamines. Cereals, fruits, and dairy products in the ingredient categories, and rice dishes and rice combined with others in recipe categories had the lowest level exposure to N-nitrosamines. In case of N-nitrosamines, unlike other cooking related food contaminants, boiled dishes such as soups and stews and dishes mainly consisting of fishes and shellfishes had highest level of exposure, showing a large discrepancy with the previous thought of processed meat is the main source of N-nitrosamines.

The Development of a Model for Selecting Method of Entry for Apartment in Remodeling an Underground Parking Lot (지하주차장 리모델링 공사시 주동진입방법 선정 모델 개발)

  • Song, Nak-Hyun;Jung, In-Su;Lee, Chan-Sik
    • Korean Journal of Construction Engineering and Management
    • /
    • v.10 no.2
    • /
    • pp.65-74
    • /
    • 2009
  • It is expected that the number of apartment complexes in Korea that are over 20 years old will rapidly increase to more than 3,500,000. Consequently, the remodeling of these buildings is being revitalized throughout the country. Among the requirements for such remodeling, the expansion of parking lots has considerable weight. When enlarging a parking lot, the access route from an underground floor to the main building (i.e., the means of entry into the main building) determines the possibility of vertical enlargement for elevators, the size of the parking lot, the construction period, and construction expenses, etc. When enlarging an underground parking lot of an apartment complex, the access between the main building and the parking lot, as well as the inhabitants' requirements for entering the main building, are generally determined based on the designer's experience, rather than on the exact estimation of the peculiarity of the complex. In order to resolve such a problem, when enlarging an underground parking lot, a systematic and rational method is needed for selecting the means of entry into the main building. In this study, a selection model is derived for the method of selecting an access route into the main building when constructing an underground parking lot, in order to provide a reasonable decision-making process. A research method was investigated for determining the access route into the main building when enlarging a parking lot. On the basis of research carried out through in-depth interviews with experts, the characteristics for each means of entry into the main building were analyzed and the factors affecting the selection of the access route were deduced. The affecting factors selected were construction efficiency, convenience efficiency and economic efficiency. Weight values were then estimated for the selected affecting factors by applying the AHP method. Results showed that convenience efficiency, which gained the highest value, is the most important factor in selecting the means of entry into the main building. The most suitable means of entry into the main building was also suggested after estimating the applicability of the site by selecting complexes with remodeling possibility. This study will be applied as a reference for selecting the means of entry into the main building when constructing an underground parking lot particularly for older apartment complexes.

Quantifying Uncertainty of Calcium Determination in Infant Formula by AAS and ICP-AES (AAS 및 ICP-AES에 의한 조제분유 중 칼슘 함량 분석의 측정불확도 산정)

  • Jun, Jang-Young;Kwak, Byung-Man;Ahn, Jang-Hyuk;Kong, Un-Young
    • Korean Journal of Food Science and Technology
    • /
    • v.36 no.5
    • /
    • pp.701-710
    • /
    • 2004
  • Uncertainty was quantified to evaluate calcium determination result in infant formula with AAS (Atomic Absorption Spectrometry) and ICP-AES (Inductively Coupled Plasma-Atomic Emission Spectrometry). Uncertainty sources in measurand, such as sample weight, final volume of sample, sample dilution and the instrumental result were identified and used as parameters for combined standard uncertainty based on the GUM (Guide to the expression of uncertainty in measurement) and Draft EURACHEM/CITAC Guide. Uncertainty components of each sources in measurand were identified as resolution, reproducibility and stability of chemical balance, standard material purity, standard material molecular weight, standard solution concentration, standard solution dilution factor, sample dilution factor, calibration curve, recovery, instrumental precision, reproducibility, and stability, Each uncertainty components were evaluated by uncertainty types and included to calculate combined uncertainty. The kinds of uncertainty sources and components in the analytical method by AAS and ICP-AES were same except sample dilution factor for AAS. The analytical results and combined standard uncertainties of calcium content were estimated within the certification range $(367{\pm}20\;mg/100g)$ of CRM (Certified Reference Material) and were not significantly different between method by AAS followed by ashing and method by ICP-AES followed by acid digestion as $359.52{\pm}23.61\;mg/100g\;and\;354.75{\pm}16.16\;mg/100g$, respectively. Identifying uncertainty sources related with precision, repeatability, stability, and maintaining proper instrumental conditions as well as personal proficiency was needed to reduce analytical error.