• Title/Summary/Keyword: Reference Signal

Search Result 1,446, Processing Time 0.029 seconds

A new approach to enhancement of ground penetrating radar target signals by pulse compression (파형압축 기법에 의한 GPR탐사 반사신호 분해능 향상을 위한 새로운 접근)

  • Gaballah, Mahmoud;Sato, Motoyuki
    • Geophysics and Geophysical Exploration
    • /
    • v.12 no.1
    • /
    • pp.77-84
    • /
    • 2009
  • Ground penetrating radar (GPR) is an effective tool for detecting shallow subsurface targets. In many GPR applications, these targets are veiled by the strong waves reflected from the ground surface, so that we need to apply a signal processing technique to separate the target signal from such strong signals. A pulse-compression technique is used in this research to compress the signal width so that it can be separated out from the strong contaminated clutter signals. This work introduces a filter algorithm to carry out pulse compression for GPR data, using a Wiener filtering technique. The filter is applied to synthetic and field GPR data acquired over a buried pipe. The discrimination method uses both the reflected signal from the target and the strong ground surface reflection as a reference signal for pulse compression. For a pulse-compression filter, reference signal selection is an important issue, because as the signal width is compressed the noise level will blow up, especially if the signal-to-noise ratio of the reference signal is low. Analysis of the results obtained from simulated and field GPR data indicates a significant improvement in the GPR image, good discrimination between the target reflection and the ground surface reflection, and better performance with reliable separation between them. However, at the same time the noise level slightly increases in field data, due to the wide bandwidth of the reference signal, which includes the higher-frequency components of noise. Using the ground-surface reflection as a reference signal we found that the pulse width could be compressed and the subsurface target reflection could be enhanced.

Malfunction detection in plasma etching process using EPD signal trace (EPD 신호검출에 의한 플라즈마식각공정의 이상검출)

  • 이종민;차상엽;최순혁;우광방
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 1996.10b
    • /
    • pp.1360-1363
    • /
    • 1996
  • EPD(End Point Detection) is used to decide etching degree of layer which must be removed at wafer etching process in plasma etching process which is one of the most important process in semiconductor manufacturing. In this thesis, the method which detects malfunction of etching process in real-time will be discussed. Several EPD signal traces are collected in normal plasma etching condition and used as reference EPD signal traces. Critical points can be detected by applying differentiation and zero-crossing techniques to reference EPD signal. Mean and standard deviation of critical parameters which is memorized from reference EPD signal are calculated and these determine the lower and higher limit of control chart. And by applying statical control chart to EPD signals which are collected in real etching process malfunctions of process are detected in real-time. By means of applying this method to the real etching process we prove our method can accurately detect the malfunction of etching process and can compensate disadvantage of current industrial method.

  • PDF

A Weighted Preliminary Cut-off Indoor Positioning Scheme Based on Similarity between Peaks of RSSI (최대 RSSI 간의 유사도를 기반으로 한 가중치 부여 사전 컷-오프 실내 위치 추정 방식)

  • Kim, Dongjun;Son, Jooyoung
    • Journal of Korea Multimedia Society
    • /
    • v.21 no.7
    • /
    • pp.772-778
    • /
    • 2018
  • We have previously proposed a preliminary cut-off indoor positioning scheme considering the reference point with the same signal similarity. This scheme estimates the position using the relative rank of the peak of received signal strength from the beacons around user. However, this scheme has a weak point with lower accuracy when there are more than one nearest reference points having the same signal similarity. In order to tackle this, we propose a weighted preliminary cut-off indoor positioning scheme. Firstly, if the above problem occurs, the similarity to the peak of signal strength is considered as well as the relative rank. Next, weights are assigned to the nearest reference points using the similarity to the peak of the received signal strength. Finally, the user's position is estimated by applying the weights. As a result, the weighted preliminary cut-off scheme improves the positioning accuracy by about 7.9% compared to the previous scheme.

Real-time malfunction detection of plasma etching process using EPD signal traces (EPD 신호궤적을 이용한 플라즈마 식각공정의 실시간 이상검출)

  • Cha, Sang-Yeob;Yi, Seok-Ju;Koh, Taek-Beom;Woo, Kwang-Bang
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.4 no.2
    • /
    • pp.246-255
    • /
    • 1998
  • This paper presents a novel method for real-time malfunction detection of plasma etching process using EPD signal traces. First, many reference EPD signal traces are collected using monochromator and data acquisition system in normal etching processes. Critical points are defined by applying differentiation and zero-crossing method to the collected reference signal traces. Critical parameters such as intensity, slope, time, peak, overshoot, etc., determined by critical points, and frame attributes transformed signal-to symbol of reference signal traces are saved. Also, UCL(Upper Control Limit) and LCL(Lower Control Limit) are obtained by mean and standard deviation of critical parameters. Then, test EPD signal traces are collected in the actual processes, and frame attributes and critical parameters are obtained using the above mentioned method. Process malfunctions are detected in real-time by applying SPC(Statistical Process Control) method to critical parameters. the Real-time malfunction detection method presented in this paper was applied to actual processes and the results indicated that it was proved to be able to supplement disadvantages of existing quality control check inspecting or testing random-selected devices and detect process malfunctions correctly in real-time.

  • PDF

Performance Analysis of Acquisition Methods for DGPS Reference Receiver under Noisy Environment

  • Park, Sang-Hyun;Cho, Deuk-Jae;Suh, Sang-Hyun
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • v.2
    • /
    • pp.107-112
    • /
    • 2006
  • The previous acquisition method of GPS receiver for reference station adopts not only the coherent integration method but also the non-coherent integration method in order to enhance sensitivity under noisy environment. However, under noisy environment, the previous GPS signal acquisition method causes the non-coherent integration loss which is a major factor among losses that can be caused during GPS signal acquisition. The non-coherent integration loss also increases with the strength of the received noise. This paper has intention of analyzing the performance of the GPS signal acquisition method proposed to effectively enhance sensitivity of DGPS reference receiver under noisy environment. This paper presents that the proposed GPS signal acquisition method suppresses the non-coherent integration loss through post-processing simulation. Furthermore, with regard to the mean acquisition time, it is shown that the number of search cells of the proposed GPS signal acquisition method is much fewer than that of the previous GPS signal acquisition method.

  • PDF

A Study of the Current Reference Signal Generation Circuit for Single-Phase Harmonic Elimination Systems (단상 전원 고조파 제거 시스템을 위한 기준전류 생성회로에 대한 연구)

  • Jung Done-youl;Park Chong-yeon;Kim Sang-hun;Choi Won-ho
    • The Transactions of the Korean Institute of Electrical Engineers B
    • /
    • v.54 no.7
    • /
    • pp.335-342
    • /
    • 2005
  • This paper presents a circuit to generate the current reference signal for single-phase harmonic elemination systems. Some of conventional methods for the current reference signal generation based on neural network algorithms. It requires complex circuitry to implement. the simplest method is to use analog filters. but it is difficult to obtain good current reference signals. So, we propose the harmonic detection circuit using GIC(Generalized Impedance Converter) for the purpose of low cost ,simple circuitry and high performance, Simulation and experimental results verify that the proposed circuit has better harmonic detection performance than conventional circuit.

Estimation of single-trial event-related potentials using multirate signal processing latency compensation (멀티레이트 신호처리와 동적 래이턴스 보정에 의한 단일 응답 유발전위 뇌파 추출)

  • 이용희;이두수
    • Journal of the Korean Institute of Telematics and Electronics S
    • /
    • v.34S no.12
    • /
    • pp.60-69
    • /
    • 1997
  • We present an average method based on the multirate signal processing and dynamic allocation average for the purpose of monitoring event-related potentials(ERP) and continuously and dynamically. In the proposed method, first, latency shifts are detected through the cross correlation between a current response and the reference response. Then, the multirate signal processing which is composed of up-sampler, lowpass filter, and down sampler is performed to compensate the latency shifts of the reference response, therefore we obtain the reference response with a peak latencies compenated by those of a current response. Finally, the single response is obtained by averaging the compensated reference response and a current response. In the simulation, the results of quantitative evaluation by simulation and the results using linical data are presented. From the result, the proposed method reflects dynamic time-varying ERP more exactly than previous methods and is also effective in consecutive monitoring of ERP.

  • PDF

Performance Analysis of the Array Shape Estimation Methods Based on the Nearfield Signal Modeling (근거리 신호 모델링을 기반으로 한 어레이 형상 추정 기법들의 성능 분석)

  • Park, Hee-Young;Lee, Chung-Yong
    • The Journal of the Acoustical Society of Korea
    • /
    • v.27 no.5
    • /
    • pp.221-228
    • /
    • 2008
  • To estimate array shape with reference sources in SONAR systems, nearfield signal modeling is required for the reference sources near a towed array. Array shape estimation method based on the nearfield signal modeling generally exploits the spatial covariance matrix of the received reference sources. Among those method, nearfield eigenvector method uses the eigenvector corresponding to the maximum eigenvalue as a steering vector of the reference source. In this paper, we propose a simplified subspace fitting method based on the nearfield signal modeling with spherical wave modeling. Furthermore, we analyze performance of the array shape estimation methods based on the nearfield signal modeling for various environments. The results of the numerical experiments indicate that the simplified subspace fitting method and the nearfield eigenvector method with single reference source shows almost similar performance. Furthermore, the simplified subspace fitting method with 2 reference sources consistently estimates the shape of the array regardless of the incident angle of the reference sources, whereas the nearfield eigenvector method cannot apply for the case of 2 reference sources.

Development of Portable Cable Fault Detection System with Automatic Fault Distinction and Distance Measurement (자동 고장 판별 및 거리 측정 기능을 갖는 휴대용 케이블 고장 검출 장치 개발)

  • Kim, Jae-Jin;Jeon, Jeong-Chay
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.65 no.10
    • /
    • pp.1774-1779
    • /
    • 2016
  • This paper proposes a portable cable fault detection system with automatic fault distinction and distance measurement using time-frequency correlation and reference signal elimination method and automatic fault classification algorithm in order to have more accurate fault determination and location detection than conventional time domain refelectometry (TDR) system despite increased signal attenuation due to the long distance to cable fault location. The performance of the developed system method was validated via an experiment in the test field constructed for the standardized performance test of power cable fault location equipments. The performance evaluation showed that accuracy of the developed system is less than 1.34%. Also, an error of automatic fault type and location by detection of phase and peak value through elimination of the reference signal and normalization of correlation coefficient and automatic fault classification algorithm not occurred.