• Title/Summary/Keyword: Reference Sample

Search Result 859, Processing Time 0.027 seconds

Quality Characteristics of Wet Noodle with Maesil(Prunus mume) Juice (매실(Prunus mume) 착즙액을 첨가한 생국수의 품질 특성)

  • Lee, Hyun-Ae;Nam, Eun-Sook;Park, Shin-In
    • Journal of the Korean Society of Food Culture
    • /
    • v.18 no.6
    • /
    • pp.527-535
    • /
    • 2003
  • This study was conducted to investigate the properties of wet noodle when different concentrations of Prunus mume juice were added to the wheat flour. The characteristics of wet noodle including cooking properties, color, mechanical texture properties, and sensory quality were determined. The compositions of Prunus mume were 88.19% moisture, 0.45% crude ash, 4.04% citric acid and 0.41% total sugars. The pH of Prunus mume was 2.76. The moisture absorption rate, weight, volume and turbidity of cooked noodles added with Prunus mume juice were lower than reference sample. When the amount of Prunus mume juice increased, the Hunter L(brightness) value, a(redness) value of cooked noodles decreased but b(yellowness) value increased. Instrumental rheological characteristics of wet noodle containing Prunus mume juice were measured with a texture analyzer. The hardness, adhesiveness, cohesiveness, springiness and gumminess of wet noodle with 20% Prunus mume juice were higher than others. However, the hardness of cooked noodle decreased with the increase in the amount of Prunus mume juice into noodle. The adhesiveness, cohesiveness, springiness and gumminess of cooked noodles added with Prunus mume juice were higher than reference sample. The results of sensory evaluation of cooked noodles containing Prunus mume juice indicated that the appearance, color, taste and chewiness of the cooked noodle with 10% Prunus mume juice showed the higher preference than others. Based on cooking properties, rheological and sensory evaluation, addition of 10% Prunus mume juice suggested to be acceptable for processing wet noodle.

Optimization of the Manufacturing of Process Butter by Response Surface Methodology and Its Texture and Rheological Properties (반응표면분석법에 의한 가공버터 제조의 최적화 및 Rheology 분석)

  • Suh, Mun-Hui;Yoon, Kyeong;Baick, Seung-Chun
    • Journal of Dairy Science and Biotechnology
    • /
    • v.26 no.2
    • /
    • pp.51-56
    • /
    • 2008
  • Using central composite design, we have designed optimization of the manufacturing of processed butter. And response surface analysis by least-square regression was used Statistical Analysis System(SAS). Central composite design can be achieved by response surface techniques that allow flexibility in modeling and analysis. Response surface methodology(RSM) was used to optimize hardness(%) using as independent variables; the content of butter($X_1$), ranging from 50 to 90(%), the content of soybean oil($X_2$), from 0 to 20(%), and the hydrogenated soybean oil($X_3$) from 0 to 4(%). The results on the regression coefficients calculated for overrun by response surface by least-square regression(RSREG) were followed. It was considered that the linear regression was significant(p<0.01). As for the processed butter, the regression model equation for the hardness(Y, %) to the change of an independent variable could be predicted as follow: $Y=60.88-8.92X_2-{29.3X_2}^2$. The optimal for the manufacturing of processed butter were determined at the content of butter of 88.22%, soybean oil of 6.71% and hydrogenated soybean oil of 2.36%, respectively. Optimum compositions were resulted in hardness of 65.78 N. Finally the reference sample(Butter in the morning, Seoul Dairy Co-op.) and processed butter manufacturing under the optimal conditions were compared with spreadability test. The spreadability scores result from reference sample and butter under optimal conditions was not found a significant difference.

  • PDF

Demonstration of the Usefulness of Optical Coherence Tomography in Imaging a Mouse Tail Model of Lymphedema

  • Kim, Hui Dong;Kim, Dong Kyu;Chae, Yu-Gyeong;Park, Seok Gyo;Kim, Ghi Chan;Jeong, Ho Joong;Sim, Young-Joo;Ahn, Yeh-Chan
    • Current Optics and Photonics
    • /
    • v.1 no.2
    • /
    • pp.132-137
    • /
    • 2017
  • To investigate the usefulness of optical coherence tomography (OCT) for imaging lymphedema, we directly compared it to other histological methods in a mouse model of lymphedema. We performed detailed imaging of the lymphedema lesion on a mouse tail. We imaged the mouse tail in vivo with OCT and created histopathological samples. We constructed a spectrometer-based OCT system using a fiber-optic Michelson interferometer. The light was directed to 50:50 couplers that split the light into reference and sample arms. Backscattered light from a reference mirror and the sample produced an interference fringe. An OCT image of the lymphedema model revealed an inflammatory reaction of the skin that was accompanied by edema, leading to an increase in the light attenuation in the dermal and subcutaneous layers. Similar to OCT image findings, histological biopsy showed an inflammatory response that involved edema, increased neutrophils in epidermis and subdermis, and lymphatic microvascular dilatation. Furthermore, the lymphedema model showed an increase in thickness of the dermis in both diagnostic studies. In the mouse tail model of lymphedema, OCT imaging showed very similar results to other histological examinations. OCT provides a quick and useful diagnostic imaging technique for lymphedema and is a valuable addition or complement to other noninvasive imaging tools.

Rapid Identification of Staphylococcus Species Isolated from Food Samples by Matrix-Assisted Laser Desorption/Ionization Time-of-Flight Mass Spectrometry

  • Kim, Eiseul;Kim, Hyun-Joong;Yang, Seung-Min;Kim, Chang-Gyeom;Choo, Dong-Won;Kim, Hae-Yeong
    • Journal of Microbiology and Biotechnology
    • /
    • v.29 no.4
    • /
    • pp.548-557
    • /
    • 2019
  • Staphylococcus species have a ubiquitous habitat in a wide range of foods, thus the ability to identify staphylococci at the species level is critical in the food industry. In this study, we performed rapid identification of Staphylococcus species using Matrix-Assisted Laser Desorption/Ionization Time-of-Flight mass spectrometry (MALDI-TOF MS). MALDI-TOF MS was evaluated for the identification of Staphylococcus reference strains (n = 19) and isolates (n = 96) from various foods with consideration for the impact of sample preparation methods and incubation period. Additionally, the spectra of isolated Staphylococcus strains were analyzed using principal component analysis (PCA) and a main spectra profile (MSP)-based dendrogram. MALDI-TOF MS accurately identified Staphylococcus reference strains and isolated strains: the highest performance was by the EX method (83.3~89.5% accuracy) at species level identification (EDT, 70.3~78.9% accuracy; DT, less than 46.3~63.2% accuracy) of 24-h cultured colonies. Identification results at the genus level were 100% accurate at EDT, EX sample preparation and 24-h incubation time. On the other hand, the DT method showed relatively low identification accuracy in all extraction methods and incubation times. The analyzed spectra and MSP-based dendrogram showed that the isolated Staphylococcus strains were characterized at the species level. The performance analysis of MALDI-TOF MS shows the method has the potential ability to discriminate between Staphylococcus species from foods in Korea. This study provides valuable information that MALDI-TOF MS can be applied to monitor microbial populations and pathogenic bacteria in the food industry thereby contributing to food safety.

Preparation and assessment of airborne fibrous reference sample for a proficiency test (국내 공기 중 섬유상 분진 숙련도 시험용 표준시료 제조 및 평가)

  • Lim, Hoju;Ryu, Jaihyuk;Choi, Sungho;Choi, Arum;Jung, Hyunsung;Ryu, Jungmin;Kim, Hyunwook;Jang, Seongki
    • Analytical Science and Technology
    • /
    • v.22 no.5
    • /
    • pp.369-375
    • /
    • 2009
  • We evaluated the homogeneity and accuracy of low level airborne fibrous standard, and accomplished the proper proficiency test. We had found that the correlation of concentration of standard solution and asbestos density was 0.9863~0.9968, and concluded that the proper guideline of the analysis result was ${\mid}Z{\mid}{\leq}2$ interval of Z-score.

An Empirical Validation Study for Calibration Verification in TDM Test (검량보정 검증의 실험적 적합성에 대한 연구 -치료적 약물검사를 중심으로-)

  • Chang, Sang-Wu;Kim, Nam-Yong;Choi, Ho-Sung;Park, Yong-Won;Chu, Gyung-Bok;Yun, Keun-Young;Park, Byung-Ok
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.37 no.1
    • /
    • pp.1-7
    • /
    • 2005
  • The purpose of this study was to verify (i) a consistent calibration verification for the assessment of method linearity and (ii) calibration agreement with calibration settings. We validated calibration verification through method linearity with different lot number of individual calibrators that span the working range for 9 tests except salicylate with control sample in test. We evaluated that it covered broad analyte range to assay from near zero to the top of the measuring range with 5 or 6 points every three times for 10 analytes in TDM test. Target values were plotted on X-axis with assigned or observed values on the Y-axis. Working range were as follows. Calibration verification of the measuring range (maximum to minimum values) has been validated asetaminophen 0.1 to $304.6_{\mu}g/mL$, salicylate 0 to $1005_{\mu}g/mL$, valproic acid 3.2 to $154.19_{\mu}g/mL$, digoxin 0.17 to 5.65 ng/mL, vancomycine 1.3 to $80.51_{\mu}g/mL$, carbarmazepine 0.1 to $22.3_{\mu}g/mL$, phenytonin 0.6 to $40.21_{\mu}g/mL$, theophyline 0.2 to $40.21_{\mu}g/mL$, primidone 0 to $24.07_{\mu}g/mL$, phenobarbital 0.6 to $60.0_{\mu}g/mL$. Drawing a straight line through five or six points of these data showed good linearity. We are sure that it is important to assess the calibration verification of a test method to ascertain the lowest and highest test results that are reliable.

  • PDF

Development of Surface Velocity Measurement Technique without Reference Points Using UAV Image (드론 정사영상을 이용한 무참조점 표면유속 산정 기법 개발)

  • Lee, Jun Hyeong;Yoon, Byung Man;Kim, Seo Jun
    • Ecology and Resilient Infrastructure
    • /
    • v.8 no.1
    • /
    • pp.22-31
    • /
    • 2021
  • Surface image velocimetry (SIV) is a noncontact velocimetry technique based on images. Recently, studies have been conducted on surface velocity measurements using drones to measure a wide range of velocities and discharges. However, when measuring the surface velocity using a drone, reference points must be included in the image for image correction and the calculation of the ground sample distance, which limits the flight altitude and shooting area of the drone. A technique for calculating the surface velocity that does not require reference points must be developed to maximize spatial freedom, which is the advantage of velocity measurements using drone images. In this study, a technique for calculating the surface velocity that uses only the drone position and the specifications of the drone-mounted camera, without reference points, was developed. To verify the developed surface velocity calculation technique, surface velocities were calculated at the Andong River Experiment Center and then measured with a FlowTracker. The surface velocities measured by conventional SIV using reference points and those calculated by the developed SIV method without reference points were compared. The results confirmed an average difference of approximately 4.70% from the velocity obtained by the conventional SIV and approximately 4.60% from the velocity measured by FlowTracker. The proposed technique can accurately measure the surface velocity using a drone regardless of the flight altitude, shooting area, and analysis area.

Determination of Water-holding Capacity of Porcine Musculature Based on Released Water Method Using Optimal Load

  • Joo, Seon-Tea
    • Food Science of Animal Resources
    • /
    • v.38 no.4
    • /
    • pp.823-828
    • /
    • 2018
  • The purpose of this study was to evaluate the suitability of the released water (RW) method for measuring water-holding capacity (WHC) by pressure and filter-paper absorption within two thin plastic films. One hundred fifty pork loins with considerable variations in WHC (three pork qualities: PSE, pale, soft, and exudative; RFN, reddish-pink, firm, and nonexudative; and DFD, dark, firm, and dry; 50 pork loins in each pork quality group) were used to measure drip loss (DL)% and RW % after applying different loads (1.5, 2.0, 2.5, 3.0 and 3.5 kg). Percentages of DL and RW were significantly (p<0.05) different among pork quality groups. The RW % of 2.5 kg load sample was significantly (p<0.05) higher than that of 2.0 kg or 1.5 kg load sample. However, there were no significant (p>0.05) differences in RW % among 2.5 kg, 3.0 kg, and 3.5 kg load samples for all three pork quality groups. The RW % was highly and positively correlated (r>0.95; p<0.001) with DL %. The highest correlation was observed between DL % and RW % of 2.5 kg load sample (r=0.97; p<0.001). Among all RW loads within each quality groups, the highest correlation between DL % and RW % was observed for 2.5 kg load sample (r=0.43, 0.66, and 0.46 for PSE, RFN and DFD quality groups, respectively, p<0.001). These results imply that applying 2.5 kg load is the best for determination of RW %. It is recommended as a reference method to assess DL % of pork muscles.

Efficient Sample Digestion Method for Uranium Determination in Soil using Microwave Digestion for Alpha Spectrometry (마이크로파 용해장치를 활용한 토양 중 우라늄의 알파분광분석법)

  • Kim, Chang Jong;Cho, Yoon Hae;Kim, Dae Ji;Chae, Jung Seok;Yun, Ju Yong
    • Journal of Radiation Protection and Research
    • /
    • v.37 no.4
    • /
    • pp.213-218
    • /
    • 2012
  • Alpha spectrometry has been typically used for determination of the uranium isotopes in soil. For a number of uranium analysis in soil samples, rapid sample digestion with limited quantities of mixed acid containing HF will give a contribution for effective management of uranium analysis. Microwave digestion system is evaluated for rapid sample digestion using reference uranium soil (IAEA-375 soil). For completion of 0.5 g of soil digestion by microwave, 3 ml of HF in a 10 ml of mixed acid is minimum requirement volume for completed soil digestion for 80 minutes. Microwave digestion is timely effective techniques for uranium measurement using alpha spectrometry compared to the other methods (open vessel digestion, closed vessel digestion) due to rapid sample digestion. In addition, it can be reduced the occurrence of hazardous substances by minimizing the amount of HF.

Studies on avian infectious bronchitis: II. Standardization of an indirect enzyme-linked immunosorbent assay (ELISA) for antibody measurement (닭 전염성 기관지염에 관한 연구: II. 간접 enzyme-linked immunosorbent assay(ELISA)에 의한 항체가 측정)

  • Chang, Chong-ho;Kim, Sun-joong
    • Korean Journal of Veterinary Research
    • /
    • v.29 no.4
    • /
    • pp.503-515
    • /
    • 1989
  • Critical parameters affecting sensitivity and specificity of an enzyme-linked immunosorbent assay(ELISA) for detection of antibodies to avian infections bronchitis virus(IBV) were standardized. By adopting the optimized conditions an equation calculating ELISA antibody titers from the observations at single serum dilution was formulated. The purified antigen of IBV Mass-41 strain was dispensed into polystyrene microplate wells at a concentration of 300ng per well($100{\mu}l$) and the plates were coated by completey drying at $37^{\circ}C$. Diluted chicken serum and horseradish peroxidase conjugated goat anti-chicken IgG were added in order in $100{\mu}l$ volumes per well and allowed to react for 30 minutes each at room temperature. Just before use and after each reaction the plates were washed three times with distilled water. Finally o-phenylenediamine solution was added as an enzyme substrate. After incubation for another 15 minutes at room temperature absorbances were read at 492nm. Hyperimmune serum against Mass-41 strain was used as internal reference positive(IRP) serum. After repeated titration of IRP and negative serum, a constant titer of IRP was determined. Serum titrations were carried out for various sample sera together with IRP and negative sera and the observed titers of sample sera were corrected by reflecting the ratio between observed and constant titers of IRP serum. These corrected titers of the sample sera were plotted against sample/positive(S/P) OD ratios. All the OD's measured in the serum titrations were also corrected by substracting negative serum OD. The following equation was formulated from the above data; $Log_{10}$ ELISA titer=$5.568({\log}_{10}S/P)+4.161$ Thus it was possible to calculate ELISA titer by measuring absorbance at 1/400 single serum dilution. Titer measured by cross ELISA tests employing Mass-41 strain and three local IBV isolates were similar. These results suggest that the ELISA tests standardized in this study can be used for evaluating not only vaccinal immunity but also for infection status against fields IBV's.

  • PDF