• 제목/요약/키워드: Reference Frequency

검색결과 1,636건 처리시간 0.031초

Improved Attenuation Estimation of Ultrasonic Signals Using Frequency Compounding Method

  • Kim, Hyungsuk;Shim, Jaeyoon;Heo, Seo Weon
    • Journal of Electrical Engineering and Technology
    • /
    • 제13권1호
    • /
    • pp.430-437
    • /
    • 2018
  • Ultrasonic attenuation is an important parameter in Quantitative Ultrasound and many algorithms have been proposed to improve estimation accuracy and repeatability for multiple independent estimates. In this work, we propose an improved algorithm for estimating ultrasonic attenuation utilizing the optimal frequency compounding technique based on stochastic noise model. We formulate mathematical compounding equations in the AWGN channel model and solve optimization problems to maximize the signal-to-noise ratio for multiple frequency components. Individual estimates are calculated by the reference phantom method which provides very stable results in uniformly attenuating regions. We also propose the guideline to select frequency ranges of reflected RF signals. Simulation results using numerical phantoms show that the proposed optimal frequency compounding method provides improved accuracy while minimizing estimation bias. The estimation variance is reduced by only 16% for the un-compounding case, whereas it is reduced by 68% for the uniformly compounding case. The frequency range corresponding to the half-power for reflected signals also provides robust and efficient estimation performance.

실시간 기본주파수 추종방법에 근간한 조화 신호의 능동제어 (Active Control of Harmonic Signal Based on On-line Fundamental Frequency Tracking Method)

  • 김선민;박영진
    • 소음진동
    • /
    • 제10권6호
    • /
    • pp.1059-1066
    • /
    • 2000
  • 본 논문에서는 고조파 소음을 내는 시스템의 기본 주파수 추정을 통한 새로운 피드백 능동소음제어 방법을 제안한다. 기준신호를 측정하기 어려운 상황에서 종래의 다중 정현파 소음의 능동제어 방법은 기준신호를 측정하는 대신 추정된 주파수를 이용하여 기준신호를 만들어낸다.$^{(4)}$ 그러나 맥놀이현상(beating phenomenon)이 존재할 때는 순간적으로 특정 주파수 성분이 사라지게 되므로 적응 주파수 추정이 어렵게 되어 맥놀이현상에 의한 주파수 추정에서의 혼돈은 만들어진 기준신호를 쓸모없게 만든다. 제안된 알고리즘은 두 가지 부분으로 구성된다. 첫째는 기본주파수 추정을 이용한 기준신호 발생기이고 둘째는 기존의 피드포워드 제어 부분이다. 제안된 결정 규칙을 이용한 기본주파수 추정알고리즘은 맥놀이현상에 둔감할 뿐 아니라 기존의 직렬형 적응노치필터 방법에 비해 좋은 추종성능과 적은 주파수 추정 오차의 분산을 갖는다.$^{(4)}$ 더욱이 신호대잡음비가 좋지 않아 기존의 주파수 추정방법으로는 추정될 수 없는 주파수 성분가지 제어가 가능하다. 제안된 능동소음제어 방법의 성능을 검증하기 위해서 실측한 선박의 객실 소음과 자동차의 시변하는 엔진부밍소음에 대해서 모의 실험을 수행한다.

  • PDF

Time Frequency Domain Reflectometry 기법을 이용한 Coaxial Cable에서의 결함 감지 및 추정 (Detection and Estimation of a Faults on Coaxial Cable with TFDR Algorithm)

  • 송은석;신용준;최덕선;육종관;박진배
    • 한국항행학회논문지
    • /
    • 제7권1호
    • /
    • pp.38-50
    • /
    • 2003
  • 본 논문에서는 도선상에서 발생하는 결함 위치와 이상 유무를 감지하는 새로운 고분해능 반사측정법인 시간-주파수 영역반사측정법 (TFDR, Time-Frequency Domain Reflectometry)을 제안하였다. 고전적인 반사측정법들은 단지 시간 또는 주파수의 한 영역에서 분석되어져 왔으나, 본 논문에서 제시한 TFDR은 도선의 결함 위치와 이상 유무를 발견하기 위해 과도신호의 시간과 주파수 영역의 정보를 동시에 이용할 수 있는 시간-주파수 분석기법으로 특성화하였다. TFDR의 기준신호 설계는 측정 케이블의 물리적 성질들을 고려하여 주파수 밴드를 결정하며, 도선의 결함감지와 추정은 시간-주파수 상호상관관계 함수에 의해 이루어진다. TFDR 시스템을 이용하여 여러 결함 상태를 가진 실제 coaxial cable (RG-142, RG-400)에 대해 실험하였고 정확성을 입증하기 위해 TDR (Time Domain Reflectometry) 장비와 성능을 비교하였다. 본 논문에서는 TFDR이 TDR보다 작은 오차로 결함을 찾아냄을 나타내고 있으며, 측정된 정확도는 TFDR의 오차율이 0.5% 이하로 TDR (54750A/54754A) 장비보다 성능이 월등히 우수하다는 것을 알 수 있다.

  • PDF

1기 무한모선 전력계통의 적응 전압 제어와 거버너를 이용한 주파수 진동의 억제 (Adaptive Voltage Control of a Single Machine Infinite Bus(SMIB) Power System with Governor Control for Reduced Oscillation of the Frequency)

  • 김석균;윤태웅
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2008년도 심포지엄 논문집 정보 및 제어부문
    • /
    • pp.51-52
    • /
    • 2008
  • In this paper, we propose two control schemes. The first control scheme is an adaptive passivity-based excitation control which regulates the terminal voltage to its reference. This controller is obtained through two steps: firstly, a simple direct adaptive passivation controller is designed for the power system with parametric uncertainties; then a linear PI controller is applied to converge the terminal voltage to its reference. The second control scheme is a linear governor control which consists of the frequency and the mechanical power. It is shown that the internal dynamics are locally stable with controllable damping. In the end, the boundness of all electrical variables, the frequency, the mechanical power, and the convergence of the terminal voltage to its reference can be achieved by these control schemes.

  • PDF

Effects of JPEG Compression on Joint Transform Correlator

  • Widjaja, Joewono;Suripon, Ubon
    • 제어로봇시스템학회:학술대회논문집
    • /
    • 제어로봇시스템학회 2004년도 ICCAS
    • /
    • pp.1662-1665
    • /
    • 2004
  • A real-time joint transform correlator by using JPEG-compressed reference images is proposed as practical solution to storage problem and improvement of processing time of automatic target recognition system [1]. Effects of compression on recognition performance of join transform correlator are quantitatively investigated under situations where the target is suffered from noise and has contrast difference with respect to the reference. Two images with different spatial-frequency contents and contrast were used as the test scenes. The simulation results show that, the recognition performance of joint transform correlator by using the compressed reference images with high spatial-frequency components is more sensitive to noise and contrast difference than the low spatial-frequency image.

  • PDF

동기화한 이산화법을 이용한 능동소음제어의 성능향상에 관한 연구 (A Study on Performance Improvement of Active Noise Control Using Synchronous Sampling Method)

  • 김흥섭;오재응;신준
    • 대한기계학회논문집
    • /
    • 제18권10호
    • /
    • pp.2523-2532
    • /
    • 1994
  • In this paper, active noise control is performed in a duct system using the periodic pulse train which corresponds to the periodic component of noise source as a reference signal. Control algorithm applied in this study is possible to eliminate the acoustic feedback which occurs in the conventional filtered-x and filtered-u LMS algorithm by using electrical reference signal and has the fast adaptation speed with low filter orders by using synchronous sampling method is discussed via computer simulations and experiments of case studies such as frequency modulation, amplitude modulation and frequency differency between source signal and reference signal.

Fast Extraction of Symmetrical Components from Distorted Three-Phase Signals Based on Asynchronous-Rotational Reference Frame

  • Hao, Tianqu;Gao, Feng;Xu, Tao
    • Journal of Power Electronics
    • /
    • 제19권4호
    • /
    • pp.1045-1053
    • /
    • 2019
  • A symmetrical component decomposition scheme utilizing the characteristics of the asynchronous rotational reference frame transformation is proposed in this paper for the extraction of the positive and negative sequence components of distorted three-phase grid voltages. The undesired frequency component can be removed using a specially designed series coordinate transformation and half-cycle delays, where the delay can be controlled by adjusting the frequency of the rotating reference frame. The extracted symmetrical component can then be compensated based on the applied coordinated transformation. The dynamic response of the proposed algorithm is improved when compared to that of conventional methods. The effectiveness of the proposed algorithm is verified by simulation and experimental results.

개선된 SSTDR을 이용한 케이블 고장 검출과 위치 계산 (Detection and Location of Cable Fault Using Improved SSTDR)

  • 전정채;김재진;최명일
    • 전기학회논문지
    • /
    • 제65권9호
    • /
    • pp.1583-1589
    • /
    • 2016
  • This paper proposes an improved spread spectrum time domain reflectometry (ISSTDR) using time-frequency correlation and reference signal elimination method in order to have more accurate fault determination and location detection than conventional (SSTDR) despite increased signal attenuation due to the long distance to cable fault location. The proposed method has a two-step process: the first step is to detect a peak location of the reference signal using time-frequency correlation analysis, and the second step is to detect a peak location of the correlation coefficient of the reflected signal by removing the reference signal. The proposed method was validated through comparison with existing SSTDR methods in open-and short-circuit fault detection experiments of low voltage power cables. The experimental results showed that the proposed method can detect correlation coefficients at fault locations accurately despite reflected signal attenuation so that cable faults can be detected more accurately and clearly in comparison to existing methods.

Quadricorrelator 방식을 이용한 광주파수 잠김루프 제작 (Optical frequency locked loop using quadricorrelator)

  • 유강희;박창수;박진우
    • 한국통신학회논문지
    • /
    • 제21권12호
    • /
    • pp.3286-3292
    • /
    • 1996
  • An experimental results of optical requency locked loop with DFB semiconductor laser as VCO are presented. Using quadricorrelator as frequency difference detector and frequency off-set locking technique with 1GHz reference frequency, frequency locking range of 140MHz was achieved. This paper reports the design and realization details of the loop.

  • PDF

Model Predictive Control for Shunt Active Power Filter in Synchronous Reference Frame

  • Al-Othman, A.K.;AlSharidah, M.E.;Ahmed, Nabil A.;Alajmi, Bader. N.
    • Journal of Electrical Engineering and Technology
    • /
    • 제11권2호
    • /
    • pp.405-415
    • /
    • 2016
  • This paper presents a model predictive control for shunt active power filters in synchronous reference frame using space vector pulse-width modulation (SVPWM). The three phase load currents are transformed into synchronous rotating reference frame in order to reduce the order of the control system. The proposed current controller calculates reference current command for harmonic current components in synchronous frame. The fundamental load current components are transformed into dc components revealing only the harmonics. The predictive current controller will add robustness and fast compensation to generate commands to the SVPWM which minimizes switching frequency while maintaining fast harmonic compensation. By using the model predictive control, the optimal switching state to be applied to the next sampling time is selected. The filter current contains only the harmonic components, which are the reference compensating currents. In this method the supply current will be equal to the fundamental component of load current and a part of the current at fundamental frequency for losses of the inverter. Mathematical analysis and the feasibility of the suggested approach are verified through simulation results under steady state and transient conditions for non-linear load. The effectiveness of the proposed controller is confirmed through experimental validation.