• Title/Summary/Keyword: Reference Frequency

Search Result 1,636, Processing Time 0.03 seconds

A 10b 200MS/s 75.6mW $0.76mm^2$ 65nm CMOS Pipeline ADC for HDTV Applications (HDTV 응용을 위한 10비트 200MS/s 75.6mW $0.76mm^2$ 65nm CMOS 파이프라인 A/D 변환기)

  • Park, Beom-Soo;Kim, Young-Ju;Park, Seung-Jae;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.46 no.3
    • /
    • pp.60-68
    • /
    • 2009
  • This work proposes a 10b 200MS/s 65nm CMOS ADC for high-definition video systems such as HDTV requiring high resolution and fast operating speed simultaneously. The proposed ADC employs a four-step pipeline architecture to minimize power consumption and chip area. The input SHA based on four capacitors reduces the output signal range from $1.4V_{p-p}$ to $1.0V_{p-p}$ considering high input signal levels at a low supply voltage of 1.2V. The proposed three-stage amplifiers in the input SHA and MDAC1 overcome the low output resistance problem as commonly observed in a 65nm CMOS process. The proposed multipath frequency-compensation technique enables the conventional RNMC based three-stage amplifiers to achieve a stable operation at a high sampling rate of 200MS/s. The conventional switched-bias power-reduction technique in the sub-ranging flash ADCs further reduces power consumption while the reference generator integrated on chip with optional off-chip reference voltages allows versatile system a locations. The prototype ADC in a 65nm CMOS technology demonstrates a measured DNL and INL within 0.19LSB and 0.61LSB, respectively. The ADC shows a maximum SNDR of 54.BdB and 52.4dB and a maximum SFDR of 72.9dB and 64.8dB at 150MS/S and 200MS/s, respectively. The proposed ADC occupies an active die area of $0.76mm^2$ and consumes 75.6mW at a 1.2V supply voltage.

Studies on a pair of small spot of nonsexual gland hind of the larvae in Bomsyx mori L. (2) (유충의 생식후원선이 아닌 한 쌍의 소반점에 관한 조사연구 (2))

  • 윤종관;사기언
    • Journal of Sericultural and Entomological Science
    • /
    • no.12
    • /
    • pp.17-20
    • /
    • 1970
  • Occasionally, We make mistake of discrimination of sex since a pair of small spots around tile abdomen of 9th abdominal of males and posterior spots of females of the silkworms larvae are found at almost same position. As already have reported, more larvae which have the small spots were found in Chinese race than the Japanese. This research has been conducted in order to grasp the rate of appearance of the small spotted larvae hereditarily when hybridize with different race (F$_1$) 1. According to the first report, average 17,8% of the small spotted larvae are found in the Japanese race and 57.0% in the Chinese, but my re-invested data which was carried out recently shows that average 13.6% in the former case and 37.8% in the latter. Those new data are supposed to be come to a conclusion that the figures are flexible but in any case high frequency of appearance of the larvae were found in the Chinese race than the Japanese (Reference Table 1 ) 2. Miscalculated ratio of the larvae from males to females are 1.2-2.6%, and from females to males are found 0.5%-0.9% in the Japanese race, In case of the Chinese race, 7.1-9.4% in tile former and 2.9-3.4% in the latter. Those data also shows that more of the larvae found in Chinese race. 3. The larvae of small spotted and non-spotted are also seperated when hlybridize with different mating types and races. 4. More small spotted larvae are seen when hybridize with less appeared of the small spots of females and males which have the small spots than more appeared of the small spots of females with none spotted of the males (Reference Table 2. C.G.)B.F.). 5. More larvae of the small spots and found in case of hybridize in a group of having small spots than none of the spots (H>E). 6. With the exception of the case (A.B), in the same type of cross breeding (C.D, E.F, G,H), more larvae of the smal1 spots are also found in case of hybridize with males of having the spots than none of the spots.

  • PDF

A study on optical coherence tomography system using optical fiber (광섬유를 이용한 광영상 단층촬영기에 관한연구)

  • 양승국;박양하;장원석;오상기;김현덕;김기문
    • Proceedings of the Korean Institute of Navigation and Port Research Conference
    • /
    • 2004.04a
    • /
    • pp.5-9
    • /
    • 2004
  • In this paper, we studied the OCT(Optical Coherence Tomography) system which it has been extensively studied because of having some advantages such as high resolution cross-sectional images, low cost, and small size configuration. A basic principle of OCT system is Michelson interferometer. The characteristics of light source determine the resolution and the transmission depth. As a results, the light source have a commercial SLD with a central wavelength of 1,285 nm and FWHM(Full Width at Half Maximum) of 35.3 nm. The optical delay line part is necessary to equal of the optical path length with scattered light or reflected light from sample. In order to equal the optical path length, the stage which is attached to reference mirror is moved linearly by step motor And the interferometer is configured with the Michelson interferometer using single mod fiber, the scanner can be focused of the sample by using the reference arm. Also, the 2-dimensional cross-sectional images were measured with scanning the transverse direction of the sample by using step motor. After detecting the internal signal of lateral direction at a paint of sample, scanner is moved to obtain the cross-sectional image of 2-demensional by using step motor. Photodiode has been used which has high detection sensitivity, excellent noise characteristic, and dynamic range from 800 nm to 1,700 nm. It is detected mixed small signal between noise and interference signal with high frequency After filtering and amplifying this signal, only envelope curve of interference signal is detected. And then, cross-sectional image is shown through converting this signal into digitalized signal using A/D converter. The resolution of the OCT system is about 30$\mu\textrm{m}$ which corresponds to the theoretical resolution. Also, the cross-sectional image of ping-pong ball is measured. The OCT system is configured with Michelson interferometer which has a low contrast because of reducing the power of feedback interference light. Such a problem is overcomed by using the improved inteferometer. Also, in order to obtain the cross-sectional image within a short time, it is necessary to reduce the measurement time for improving the optical delay line.

  • PDF

A Study on the Preference Analysis of the Traditional Design Elements Emerging in the Contemporary City Park of China - with Special Reference to Beijing Olympic Forest Park - (중국 현대 도시공원에 나타난 전통원림 요소에 대한 선호도 분석 - 베이징 올림픽산림공원을 사례로 -)

  • Liu, Il-Hong;Cho, Se-Hwan
    • Journal of the Korean Institute of Traditional Landscape Architecture
    • /
    • v.28 no.2
    • /
    • pp.109-117
    • /
    • 2010
  • This study conducts a case analysis based on the Olympic Forest Park in Beijing, which is specially designed for the 2008 Beijing Olympic Games. The construction of the Olympic Forest Park not only comprises the design philosophy of city parks and forest parks, but also applies Chinese traditional design elements. This study, first, researches on the design concepts of city parks in the context of traditional landscape architecture elements from both physical and cultural perspectives. The author studies the related materials including the"General Introduction of the Beijing Olympic Forest Park Landscape Plan", and employs the approaches of site investigation and user survey and interview, to analyze the cognition and preference degree of the various traditional design elements displayed in the Olympic Forest Park. To quantize the survey data on the Olympic Forest Park, this study uses the spss(v17.0) software to run a frequency analysis and presents detailed demographic, frequencies and means analyses. The author then reaches the conclusion on the preference degree of the various Chinese traditional design elements in the Olympic Forest Park. According to the analysis result, the elements that appear with the highest frequencies are mountains and waters, traditional garden plants and artistic conception. The most favorable elements are in sequence traditional garden architecture, traditional garden philosophical thinking and artistic conception. The Olympic Forest Park in Beijing is constructed on the basis of multiple design elements, comprising Chinese traditional design elements and the historical axis. As an exemplification of contemporary city park that reflects the variation of age and development of society, the Olympic Forest Park offers the reference for the selection of traditional design elements in the future schemes of city parks. However, due to the difficulty in gathering materials about the Forest Park and the limitations on the location and time constrain of the survey, there exists lack of sufficiency that could be improved in the future.

Factors affecting the turnover intention of Industrial Accident Hospital Employees by Job Category (산재병원 구성원들의 직종별 이직의사에 관련된 영향요인)

  • Bang, Yong-Joo
    • Korea Journal of Hospital Management
    • /
    • v.8 no.3
    • /
    • pp.92-117
    • /
    • 2003
  • The purpose of this study was to analyze the characteristics of socio-demographic, organizational conflict and job satisfaction, and to examine the interrelation of influential factors in the intention of turnover. The data for this study were collected through a self-administrated survey with a structured questionnaire to 1,027 subjects from several medical doctor staff members, nursing staff members, administration staff members, pharmacist, and technical expert of eleven hospitals. The data were collected by self-reporting questionnaire from July 29 to September 7, 2002. In this analysis frequency test, t-test, ANOVA, multiple regression were used. The main results of this research is as following; 1. According to socio-demographic characteristics of the respondent's level of the intention of turnover was higher in a doctor staff members than others, for females than males, and had worked for 5-10 years in hospitals. Also, the intent to turnover was generally higher younger workers than long terms workers. 2. According to the organizational conflict characteristics as the respondents who got less conflict experience in the organization, their level of the intention of turnover was higher. And, technical conflict experiences were expressed greater than hierarchical conflict experiences. 3. According to the job satisfaction characteristics as his or her satisfaction that is about the promotion, working itself, salary, and fellowship in the organizational was higher, the level of the intention of turnover was lower. 4. According to the result of Multiple Regression for the doctor staff members in general hospitals rather than special hospitals was negatively correlated with the satisfaction of working itself while hierarchical conflict factors in the organizational conflict characteristics was positively correlated with the intention of turnover. For the nursing staff members the job satisfaction for the working itself, salary were negatively correlated with the intention of turnover. For the administration staff members as the job satisfaction for the working itself was negatively correlated with the intention of turnover. For medical and pharmacy staff members as more working experience, correlation with the intention of turnover was negative. Besides, as the job satisfaction for the working itself and the fellowship was negatively correlated with the intention of turnover. For the skill and technicians, the job satisfaction for the working itself, promotion were negatively correlated with the intention of turnover. The above indicate that job satisfaction and promote their ability and form a good relationship with organization members were very important to decrease the intention of turnover. This study identified the major effective factors of the intention of turnover and analyzed the differences among the job category. In that respect, it is significant for the study to be able to provide a reference for managing hospital of industrial accident and organizational development. However, this study has a problem, which is not to identify a valuable model for examining the relationship between organizational factors such as organizational conflict, job satisfaction, and intention of turnover. Therefore, further study is needed and strengthened in the field of intention of turnover for hospital for industrial accident.

  • PDF

Systematic Review of Selection of Acupuncture Points for Lower Back Pain (요통 침치료를 위한 경혈 선정에 관한 체계적 문헌 고찰)

  • Lee, In-Seon;Jo, Hee-Jin;Lee, Soon-Ho;Jung, Won-Mo;Kim, Song Yi;Park, Hi-Joon;Lee, Hyejung;Chae, Younbyoung
    • Korean Journal of Acupuncture
    • /
    • v.29 no.4
    • /
    • pp.519-536
    • /
    • 2012
  • Objectives : The purpose of this study is to figure out which acupoints are selected to treat low back pain and attempt to analyze the effectiveness of those acupoints in current clinical trials. Methods : We searched the three electronic databases(PUBMED, RISS, KISS) and manually checked related Korean journals and reference lists up to April 2012. We included randomized controlled trials, clinical controlled trials, and case reports/series using needle type acupuncture( manual acupuncture, electronic acupuncture) to treat low back pain in English and Korean. We investigated the frequency of selected acupoints, change of visual analogue scale of low back pain and statistical significance in each study among trials. Results : We included 37 articles(Domestic 17, International 20) 53 studies(Domestic 28, International 25) in this study. The most frequently adopted acupoints were BL23, BL24, BL25, GB30, BL26, BL60, BL32, BL40, KI3, GV3, ST36 in domestic studies and BL23, BL25, BL40, BL60, GB30, GB34, BL32, BL26 in international studies. There were differential effectiveness of acupoints between domestic and the international studies using statistical significance of visual analog scale for low back pain. Conclusions : These results suggest that both proximal and distal acupoints based on meridian theory were used in clinical trials to treat low back pain. It would be helpful to provide clinical guideline, evaluate the results of clinical trials appropriately, and reveal the effectiveness of acupoints.

Analysis of Trace Copper Metal at The Electrode Consisting of Carbon Nanotube using Stripping Voltammetry (벗김전압전류법을 이용한 카본나노튜브 전극에서의 구리 분석)

  • Choi, Chang-Kun;Jung, Young-Sam;Kim, Nack-Joo;Pak, Dae-Won;Chung, Kun-Yong;Kim, Lae-Hyun;Kwon, Yong-Chai
    • Korean Chemical Engineering Research
    • /
    • v.50 no.5
    • /
    • pp.933-937
    • /
    • 2012
  • In the present study, we evaluate the sensitivity and optimal stripping voltammetry (SV) conditions of copper (Cu), which is one of the main trace heavy metals inducing the environmental contamination, using carbon nanotube (CNT) electrode. In addition, the reaction mechanism of stripping reaction of Cu is investigated. The electrochemical analyses such as squarewave stripping voltammetry (SWSV) and linear scan voltammetry (LSV) are used for the evaluations. As a result of that, the best SWSV conditions like squarewave amplitude of 15 mV, frequency of 60 Hz, deposition potential of -1.0V vs. Ag/AgCl and deposition time of 200s are determined with the measured Cu sensitivity of $1.824{\mu}A/{\mu}M$. As a driving force affecting the stripping reaction of Cu, surface reaction is more dominant one than diffusion. These results are compared with other reference results and it is confirmed that our suggested CNT electrode gives rise to better Cu sensitivity result than other references.

A Calibration-Free 14b 70MS/s 0.13um CMOS Pipeline A/D Converter with High-Matching 3-D Symmetric Capacitors (높은 정확도의 3차원 대칭 커패시터를 가진 보정기법을 사용하지 않는 14비트 70MS/s 0.13um CMOS 파이프라인 A/D 변환기)

  • Moon, Kyoung-Jun;Lee, Kyung-Hoon;Lee, Seung-Hoon
    • Journal of the Institute of Electronics Engineers of Korea SD
    • /
    • v.43 no.12 s.354
    • /
    • pp.55-64
    • /
    • 2006
  • This work proposes a calibration-free 14b 70MS/s 0.13um CMOS ADC for high-performance integrated systems such as WLAN and high-definition video systems simultaneously requiring high resolution, low power, and small size at high speed. The proposed ADC employs signal insensitive 3-D fully symmetric layout techniques in two MDACs for high matching accuracy without any calibration. A three-stage pipeline architecture minimizes power consumption and chip area at the target resolution and sampling rate. The input SHA with a controlled trans-conductance ratio of two amplifier stages simultaneously achieves high gain and high phase margin with gate-bootstrapped sampling switches for 14b input accuracy at the Nyquist frequency. A back-end sub-ranging flash ADC with open-loop offset cancellation and interpolation achieves 6b accuracy at 70MS/s. Low-noise current and voltage references are employed on chip with optional off-chip reference voltages. The prototype ADC implemented in a 0.13um CMOS is based on a 0.35um minimum channel length for 2.5V applications. The measured DNL and INL are within 0.65LSB and l.80LSB, respectively. The prototype ADC shows maximum SNDR and SFDR of 66dB and 81dB and a power consumption of 235mW at 70MS/s. The active die area is $3.3mm^2$.

A Design of Power Management IC for CCD Image Sensor (CCD 이미지 센서용 Power Management IC 설계)

  • Koo, Yong-Seo;Lee, Kang-Yoon;Ha, Jae-Hwan;Yang, Yil-Suk
    • Journal of IKEEE
    • /
    • v.13 no.4
    • /
    • pp.63-68
    • /
    • 2009
  • The power management integrated circuit(PMIC) for CCD image sensor is presented in this study. A CCD image sensor is very sensitive against temperature. The temperature, that is heat, is generally generated by the PMIC with low efficiency. Since the generated heat influences performance of CCD image sensor, it should be minimized by using a PMIC which has a high efficiency. In order to develop the PMIC with high efficiency, the input stage is designed with synchronous type step down DC-DC converter. The operating range of the converter is from 5V to 15V and the converter is controlled using PWM method. The PWM control circuit consists of a saw-tooth generator, a band-gap reference circuit, an error amplifier and a comparator circuit. The saw-tooth generator is designed with 1.2MHz oscillation frequency. The comparator is designed with the two stages OP Amp. And the error amplifier has 40dB DC gain and $77^{\circ}$ phase margin. The output of the step down converter is connected to input stage of the charge pump. The output of the charge pump is connected to input of the LDO which is the output stage of the PMIC. Finally, the PMIC, based on the PWM control circuit and the charge pump and the LDO, has output voltage of 15V, -7.5V, 3.3V and 5V. The PMIC is designed with a 0.35um process.

  • PDF

Clinicopathological Features in Bilateral Breast Cancer

  • Baykara, Meltem;Ozturk, Selcuk Cemil;Buyukberber, Suleyman;Helvaci, Kaan;Ozdemir, Nuriye;Alkis, Necati;Berk, Veli;Koca, Dogan;Coskun, Ugur;Oksuzoglu, Berna;Uncu, Dogan;Arpaci, Erkan;Ustaalioglu, Basak Oven;Demirci, Umut;Kucukoner, Mehmet;Dogu, Gamze Gokoz;Alici, Suleyman;Akman, Tulay;Ozkan, Metin;Aslan, Ulku Yalcintas;Durnali, Ayse Gok;Benekli, Mustafa
    • Asian Pacific Journal of Cancer Prevention
    • /
    • v.13 no.9
    • /
    • pp.4571-4575
    • /
    • 2012
  • Introduction and Purpose: The frequency of bilateral breast cancer is 1.4-11.0% among all breast cancers. It can present as synchronous (SC) or metachronous (MC). Data regarding clinical course of bilateral breast cancer are scarce. In this study, we therefore evaluated demographic, pathological and clinical characteristics, treatments and responses in bilateral breast cancer cases; making distinctions between metachronous-synchronous and comparing with historic one-sided data for the same parameters. Materials and Methods: One hundred fifty bilateral breast cancer cases from ten different centers between 2000 and 2011 were retrospectively scanned. Age of the cases, family history, menopausal status, pathological features, pathological stages, neoadjuvant, surgery, adjuvant and palliative chemotherapy/radiotherapy were examined in the context of the first and second occurrence and discussed with reference to the literature. Results: Metachronous and synchronous groups showed similar age, menopausal status, tumor type, HER2/neu expression; the family history tumor grade, tumor stage, ER-negativity rate, local and distant metastases rates, surgery, adjuvant chemotherapy application rates were identified as significantly different. Palliative chemotherapy response rate was greater in the metachronous group but median PFS rates did not differ between the groups. Conclusion: Although bilateral breast cancer is not frequent, MC breast cancer is different from SC breast cancer by having more advanced grade, stage, less ER expression, more frequent rates of local relapse and distant metastasis and better response to chemotherapy in case of relapse/metastasis.