• Title/Summary/Keyword: Reference Analysis

Search Result 6,531, Processing Time 0.029 seconds

Identification of Brucella melitensis isolates originating from Mongolia and diagnostic real-time PCR evaluation using a specific SNP (몽골 유래 Brucella melitensis 동정 및 특이 SNP를 이용한 real-time PCR법에 의한 진단 평가)

  • Kang, Sung-Il;Kim, Ji-Yeon;Kim, Suk Mi;Lee, Jin Ju;Sung, So-Ra;Kim, Yeon-Hee;Jung, Suk Chan;Her, Moon
    • Korean Journal of Veterinary Research
    • /
    • v.55 no.2
    • /
    • pp.105-110
    • /
    • 2015
  • A real-time PCR assay using hybridization probe (HybProbe) has been developed to detect Brucella (B.) melitensis strains. The primer and HybProbe sets were designed based on the gap gene of chromosome I with a specific single nucleotide polymorphism of B. melitensis. Specificity of the assay was confirmed by comparison to reference Brucella species and other related strains. In the melting curve analysis, B. melitensis generated a peak at $67^{\circ}C$ unlike those for other Brucella species observed at $61^{\circ}C$. Sensitivity of the assay for B. melitensis ranged from 20 ng to 200 fg of genomic DNA. The ability to identify 94 Mongolian B. melitensis isolates using the real-time PCR assay was identical to that of classical biotyping methods and differential multiplex PCR. These data showed that this new molecular technique is a simple and quick method for detecting B. melitensis, which will be important for the control and prevention of brucellosis.

Impact of COVID-19 Pandemic on Use of Reference Sources and Services by Postgraduates' in Kenneth Dike Library, University of Ibadan, Nigeria

  • Samson Oyeyini Akande;Olalekan Abraham Adekunjo
    • International Journal of Knowledge Content Development & Technology
    • /
    • v.13 no.1
    • /
    • pp.27-41
    • /
    • 2023
  • The outbreak of the corona virus diseases (COVID-19) in the late 2019 has affected all facets of educational system including library and information services. Reference services, an important aspect of library services are not exempted from this impact. This study therefore, investigated the impact of COVI\D-19 pandemic on the use of reference services and sources by postgraduate students using Kenneth Dike Library (KDL), University of Ibadan, as a case study. Using descriptive survey of correlational type, the study adopted the use of structured questionnaire to randomly select three hundred (300) postgraduate users of reference sources and services in KDL using online survey monkey. Of the three hundred (300) copies, two hundred and twenty three (223) copies, repre- senting 74.3% were retrieved and used for analysis. Findings revealed that, in spite of COVID-19 pandemic, most postgraduate students used Current Awareness Services (203, 91.0%, mean = 3.19), Reference Sources (202, 90.5%, mean = 3.18) and On-line Public Access Catalogue (195, 87.4%, mean = 3.13); low frequency of bibliotherapy (mean=2.22), Reader's Advisory services (mean=2.30) and inter-library loan (mean=2.13) and that COVID-19 pandemic had high impact on post- graduate students' use of reference services in Kenneth Dike Library, University of Ibadan. Based on the findings, recommendations were made that library management should consider the adoption of virtual reference services (VRS) in addition to the conventional mode of refer- ence services to enhance patronage in the COVID-19 era. The library users should also be trained on how to take advantage of the COVID-19 pandemic to learn new skills in the digital space that will eventually optimize the usage of the library remotely.

The Energy Performance Evaluation of Multi-purpose Solar Window System (다기능 복합 솔라윈도우 시스템의 에너지성능평가)

  • Cho, Yil-Sik;Kim, Byoung-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.30 no.3
    • /
    • pp.10-15
    • /
    • 2010
  • The aim of this study was to analysis the Heating/cooling performance of Solar Window System built in apartments. The solar window is the idea to integrate daylight as a third form of solar energy into a PV/Solar Collector system and allows more control due to the possibility to close the reflectors. However, there can be a conflict between the desire for on one hand daylight and view and on the other hand optimal energy conversion for the PV/Solar Collector system. The process of this study is as follows: 1) The Solar Window system is designed through the investigation of previous paper and work. 2)The simulation program(ESP-r, Therm5.0, Window6.0) was used in energy performance analysis. The reference model of simulation was made up to analysis energy performance on Solar Window system. 3)Selected reference model(Floors:15, Area of Unit:$148.5m^2$) for heating/cooling energy analysis, Energy performance simulation with various variants, such as U-value of Solar Window system according to its position and angle. Consequently, When Solar Window system is equipped with balcony window of Apartment, Annual heating and cooling energy of reference model was cut down about 5%~11%.

The Study of Thermal Performance on Solar Window (다기능 솔라윈도우의 열성능 연구)

  • Cho, YilSik;Kim, Janghoi;Yang, Yoonsub;Kim, ByoungSoo
    • 한국신재생에너지학회:학술대회논문집
    • /
    • 2010.11a
    • /
    • pp.65.2-65.2
    • /
    • 2010
  • The aim of this study was to analysis the Heating/cooling performance of Solar Window built in apartments. The solar window is the idea to integrate daylight as a third form of solar energy into a PV/Solar Collector system and allows more control due to the possibility to close the reflectors. However, there can be a conflict between the desire for on one hand daylight and view and on the other hand optimal energy conversion for the PV/Solar Collector system. The process of this study is as follows: 1) The Solar Window system is designed through the investigation of previous paper and work. 2)The simulation program(ESP-r, Therm5.0, Window6.0) was used in Heating/cooling performance analysis. The reference model of simulation was made up to analysis Heating/cooling performance on Solar Window. 3)Selected reference model(Floors:15, Area of Unit:$148.5m^2$) for heating energy analysis, Energy performance simulation with various variants, such as U-value of Solar Window system according to its position and angle. Consequently, When Solar Window system is equipped with balcony window of Apartment, Annual heating and cooling energy of reference model was cut down about 5%~11%.

  • PDF

Improving Performance of Crimp Signal Analysis by Falling Edge Alignment and Parameter Error Estimation in CFM (CFM에서 하강 에지 정렬과 파라미터 에러 평가에 의한 크림프 시그널 분석 성능 향상)

  • Aurecianus, Steven;Kang, Taesam;Han, Chung Gwon;Park, Jungkeun
    • Journal of Institute of Control, Robotics and Systems
    • /
    • v.22 no.9
    • /
    • pp.686-692
    • /
    • 2016
  • A Crimp Force Monitor (CFM) is equipment for detecting crimp errors by analyzing crimp signals obtained from force and strain sensors. The analysis is commonly performed by aligning a measured crimp signal with a reference signal and comparing their difference. Current analysis methods often suffer from wrong alignments that result in false negative detections. This paper presents a new crimp signal analysis method in CFM. First, a falling edge alignment is proposed that matches falling edges of the measured and the reference signals by minimizing the absolute difference summation. Second, a signal parameter error is introduced to evaluate the crimp quality difference between the measured signal and the reference. For calculating the signal parameter error, part of a signal is identified and divided into several regions to maximize the signal parameter errors. Experiments showed that the proposed method can improve the signal alignment and accurately detect bad crimps especially with the strain sensor.

Determination of Protein Content in Pea by Near Infrared Spectroscopy

  • Lee, Jin-Hwan;Choung, Myoung-Gun
    • Food Science and Biotechnology
    • /
    • v.18 no.1
    • /
    • pp.60-65
    • /
    • 2009
  • Near infrared reflectance spectroscopy (NIRS) was used as a rapid and non-destructive method to determine the protein content in intact and ground seeds of pea (Pisum sativum L.) germplasms grown in Korea. A total of 115 samples were scanned in the reflectance mode of a scanning monochromator at intact seed and flour condition, and the reference values for the protein content was measured by auto-Kjeldahl system. In the developed ground and intact NIRS equations for analysis of protein, the most accurate equation were obtained at 2, 8, 6, 1 math treatment conditions with standard normal variate and detrend scatter correction method and entire spectrum (400-2,500 nm) by using modified partial least squares regression (n=78). External validation (n=34) of these NIRS equations showed significant correlation between reference values and NIRS estimated values based on the standard error of prediction (SEP), $R^2$, and the ratio of standard deviation of reference data to SEP. Therefore, these ground and intact NIRS equations can be applicable and reliable for determination of protein content in pea seeds, and non-destructive NIRS method could be used as a mass analysis technique for selection of high protein pea in breeding program and for quality control in food industry.

Analysis of Current Control Stability using PI Control in Synchronous Reference Frame for Grid-Connected Inverter with LCL Filter (LCL 필터를 사용하는 계통연계형 인버터의 동기좌표계 PI 전류제어 안정도 해석)

  • Jo, Jongmin;Lee, Taejin;Yun, Donghyun;Cha, Hanju
    • The Transactions of the Korean Institute of Power Electronics
    • /
    • v.21 no.2
    • /
    • pp.168-174
    • /
    • 2016
  • In this paper, current control using PI controller in the synchronous reference frame is analyzed through the relationship among bandwidth, resonance frequency, and sampling frequency in the grid-connected inverter with LCL filter. Stability is investigated by using bode plot in frequency domain and root locus in discrete domain. The feedback variable is the grid current, which is regulated by the PI controller in the synchronous reference frame. System delay is modeled as 1.5Ts, which contains computational and PWM modulator delay. Two resonance frequencies are given at 815 Hz and 3.16 kHz from LCL filter parameters. Sufficient phase and gain margins can be obtained to guarantee stable current control, in case that resonance frequency is above one-sixth of the sampling frequency. Unstable current control is performed when resonance frequency is below one-sixth of the sampling frequency. Analysis results of stability from frequency response and discrete response is the same regardless of resonance frequency. Finally, stability of current control based on theoretical analysis is clearly verified through simulation and experiment in grid-connected inverters with LCL filter.

Thermal Performance Evaluation of Movable Insulation System in Apartments (공동주택 발코니창에 설치된 가동단열 시스템의 열성능 평가)

  • Yoon, Jong-Ho;Kim, Byoung-Soo
    • Journal of the Korean Solar Energy Society
    • /
    • v.28 no.5
    • /
    • pp.28-35
    • /
    • 2008
  • The aim of this study was to analysis the Heating/cooling performance of movable insulation system built in apartments. The process of this study is as follows: 1) Test-cells of movable insulation are designed through the investigation of previous paper and work. The type of the movable insulation used in test-cell is low emissivity(5%) insulation, measured for heating season and the thermal effects are analyzed. 2) The simulation program(Design Builder) was used in energy performance analysis. the reference model of simulation was made up to analysis energy performance on movable insulation system. 3) Selected reference model(Floors:15, Area of Unit:115.5$m^2$) for heating/cooling energy analysis, Energy performance simulation with various variants, such as slate angle of movable insulation(5$^{\circ}$, 30$^{\circ}$, 50$^{\circ}$) and position of movable insulation. Consequently, When movable insulation system is equipped with balcony window of Apartment, Annual heating energy of reference model was cut down at the average of 5.4kWh/$m^2$ or 4.6% of heating/cooling energy.

Countermeasures of Specimens Showing below Reference Value in APTT Result

  • Choi, Hyun Oh;Kim, Seung Gu;Park, Sang Hee;Lee, Jae Ki;Koo, Bon Kyung;Park, Chang Ho
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.45 no.3
    • /
    • pp.87-90
    • /
    • 2013
  • The activated partial thromboplastin time (APTT) is used primarily to evaluate coagulation abnormalities in the intrinsic pathway. The proper specimen is very important factor for precise results of blood coagulation analysis. The objective of this study was to get to the conclusion of whether to analyze again and to collect blood sample over again when APTT result shows below the reference value. We evaluated 126 samples showing a value below 20.0 sec at ATPT result, which consist of 48 males and 78 females candidates during night duty from March 2012 to December 2012. Average comparisons of APTT result between first and retested analysis among study subjects were significantly different in male samples. APTT results comparison of recollected subjects among clotted samples were also significantly different with both sexes (p<0.000). We suggest that we should carefully check the samples to get accurate results and collect samples again in case of only obtaining improper samples; even though the APTT result show below reference value.

  • PDF

Measurement Uncertainty Analysis of a Turbine Flowmeter for Fuel Flow Measurement in Altitude Engine Test (엔진 고공 시험에서 연료 유량 측정용 터빈 유량계의 측정 불확도 분석)

  • Yang, In-Young
    • The KSFM Journal of Fluid Machinery
    • /
    • v.14 no.1
    • /
    • pp.42-47
    • /
    • 2011
  • Measurement uncertainty analysis of fuel flow using turbine flowmeter was performed for the case of altitude engine test. SAE ARP4990 was used as the fuel flow calculation procedure, as well as the mathematical model for the measurement uncertainty assessment. The assessment was performed using Sensitivity Coefficient Method. 11 parameters involved in the calculation of the flow rate were considered. For the given equipment setup, the measurement uncertainty of fuel flow was assessed in the range of 1.19~1.86 % for high flow rate case, and 1.47~3.31 % for low flow rate case. Fluctuation in frequency signal from the flowmeter had the largest influence on the fuel flow measurement uncertainty for most cases. Fuel temperature measurement had the largest for the case of low temperature and low flow rate. Calibration of K-factor and the interpolation of the calibration data also had large influence, especially for the case of very low temperature. Reference temperature, at which the reference viscosity of the sample fuel was measured, had relatively small contribution, but it became larger when the operating fuel temperature was far from reference temperature. Measurement of reference density had small contribution on the flow rate uncertainty. Fuel pressure and atmospheric pressure measurement had virtually no contribution on the flow rate uncertainty.