• Title/Summary/Keyword: Reduction of vibration

Search Result 2,344, Processing Time 0.029 seconds

Design of a Rubber Mount for Vibration Reduction in a Slim Optical Disk Drive (슬림형 광디스크 드라이브의 방진마운트 설계)

  • Kim, Kug-Weon;Kim, Nam-Woong
    • Transactions of the Korean Society of Machine Tool Engineers
    • /
    • v.16 no.6
    • /
    • pp.103-109
    • /
    • 2007
  • With the increase of track density, high rotational speed and the compatibility for various media in optical disk drives, the effective design to vibration reduction is very important for robust operation. Especially when a slim optical disk drive for a notebook PC is excited by a mass-unbalanced disk, internal vibration and its transmission to external case bring about severer problem than that of conventional one. In this paper a design process of a rubber mount in a slim optical disk drive for vibration reduction is presented. The characteristics of rubbery materials - hyper-elastic and visco-elastic - are measured with standard specimens. The static stiffness of a rubber mount was calculated by FEM and the dynamic stiffness is predicted with the static stiffness and the impedance test data of the standard specimen. The transmissibility tests are performed for the purpose of verification of the design process.

Tuned mass dampers for human-induced vibration control of the Expo Culture Centre at the World Expo 2010 in Shanghai, China

  • Lu, Xilin;Ding, Kun;Shi, Weixing;Weng, Dagen
    • Structural Engineering and Mechanics
    • /
    • v.43 no.5
    • /
    • pp.607-621
    • /
    • 2012
  • The Expo Culture Centre is one of the permanent buildings at the World Expo 2010 in Shanghai, China. The main structure has an oval shape and consists of 36 radial cantilever steel trusses with different lengths and inner frames made of concrete-filled rectangular steel tube members. Tuned mass dampers are used to reduce the excessive vibrations of the sixth floor that are caused by human-induced resonance. A three-dimensional analytical model of the system is developed, and its main characteristics are established. A series of field tests are performed on the structure, and the test results show that the vertical vibration frequencies of most structural cantilevers are between 2.5 Hz and 3.5 Hz, which falls in the range of human-induced vibration. Twelve pairs of tuned mass dampers weighing 115 tons total were installed in the structure to suppress the vibration response of the system. These mass dampers were tuned to the vertical vibration frequency of the structure, which had the highest possibility of excitation. Test data obtained after the installation of the tuned mass dampers are used to evaluate their effectiveness for the reduction of the vibration acceleration. An analytical model of the structure is calibrated according to the measured dynamic characteristics. An analysis of the modified model is performed and the results show that when people walk normally, the structural vibration was low and the tuned mass dampers have no effect, but when people run at the structural vibration frequency, the tuned mass dampers can reduce the floor vibration acceleration by approximately 15%.

Vibration Reduction of Optical Storage Disk Drive Using Piezoelectric Shunt (압전 션트회로를 이용한 광저장 디스크 드라이브의 진동 저감)

  • 박종성;임수철;최승복;김재환;박영필
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2002.05a
    • /
    • pp.381-386
    • /
    • 2002
  • This paper presents a piezoelectric shunt methodology to reduce unwanted vibration of optical disk drive(O.D.D.). After briefly investigating a second-order mechanical vibration absorber model, the O.D.D. structure is incorporated with the piezoelectric shunt circuit. In order to evaluate feasibility of multi-mode passive damping of the structure, admittance measurement of piezoceramic is undertaken. The parameters are optimally tuned by admittance measurement results on the basis of the circuit model and displacement transmissibility is evaluated. To verify validity of admittance measurement result, experiment is performed and vibration reduction is achieved at two different modes.

  • PDF

Analysis of the Vibration Fatigue for the Diesel Engine and Reduction Gear Connecting Shaft in a Ship (선박용 감속기어-디젤엔진 연결축의 진동 피로파손 분석)

  • Han, HyungSuk;Lee, KyungHyun;Park, Sungho;Kim, ChungSik
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.24 no.5
    • /
    • pp.407-413
    • /
    • 2014
  • The diesel engine and reduction gear combination is one of the common propulsion system in a naval vessel. Since the diesel engine has torsional vibration caused by reciprocating motion of the mass and gas pressure force of the cylinder, high cycle torsional fatigue can be occurred. Therefore, ROK navy restricts the maximum stress of the propulsion shaft according to MIL G 17859D. In this paper, the root cause for the failure of the diesel engine and reduction gear connecting shaft occurred in typical naval vessel is investigated based on the measured bending and torsional moment according to MIL G 17859D procedure.

Vibration Analysis Method for Railway Structure with Floating Slab (방진궤도가 부설된 역사의 진동해석 기법)

  • 양신추;김태욱;강윤석
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 2003.05a
    • /
    • pp.561-566
    • /
    • 2003
  • In this paper, a numerical method for evaluating the efficiency of vibration reduction of substructure under floating slab track is developed for optimal design of floating slab track. The equation of motion for train and track interaction system is derived by applying compatibility condition at the contact points between wheels and rails. The train is modelled by 3-masses system and the track by continuous support beam system. Numerical analyses are carried out to investigate the effects of train speed, stiffness and damping of slab-pad, and track irregularity upon vibration reduction in substructure under the track.

  • PDF

Torsional Vibration Analysis of a Multi-Stage Reduction Gear System (다단 감속치차계의 비틀림진동 해석)

  • 이동환;김영철;최상규;이안성
    • Proceedings of the Korean Society for Noise and Vibration Engineering Conference
    • /
    • 1996.10a
    • /
    • pp.307-312
    • /
    • 1996
  • A torsional vibration analysis of a multi-stage reduction gear box connected to a gas turbine system is presented. For a free vibration analysis the Modified Hibner Branch Method, so called "Blank Matrix Method", and the .lambda.-Matrix Method are used in the modeling and the eigenvalue solution, respectively. Also, a short circuit forced analysis of the system is performed, utilizing the energy method modeling. It is shown that the results of the free vibration analysis have the same tendency as those of the short circuit analysis. analysis.

  • PDF

The Effects of the Wave Propagation Path of Ground Vibration Induced by the Subway Train on the Reduction of Vibration Level (지하철 주변 지반진동의 전파경로가 진동레벨 감쇠에 미치는 영향)

  • Shin, Han-Chul;Cho, Sun-Kyu;Yang, Shin-Chu;Lee, Jong-Min
    • Journal of the Korean Society for Railway
    • /
    • v.12 no.5
    • /
    • pp.631-640
    • /
    • 2009
  • In this paper, Numerical analysis was conducted to study on the reduction of ground vibration level induced by subway train. The analytical results indicated that the soil properties were the predominant factor affecting the ground vibration when the tunnel was located in the soil layer. On the other hand, the rock properties were the predominant one when the tunnel was located in the rock layer. The effects of the angle between the vertical line of vibration source and the receive point on the reduction of vibration level were also evaluated. There were little difference in the reduction of vibration level when the receive point was located within $30^{\circ}$. The vibration level, however, rapidly decreased when the angle between the two points was larger than $40^{\circ}$.

Fault Diagnosis of a High-speed Railway Reduction Unit Using Analysis of Vibration Characteristics (고속철도차량 감속구동장치의 이상진단을 위한 진동특성분석)

  • Ji, Hae Young;Lee, Kang Ho;Kim, Jae Chul;Lee, Dong Hyoung;Moon, Kyoung Ho
    • Journal of the Korean Society for Railway
    • /
    • v.16 no.1
    • /
    • pp.26-31
    • /
    • 2013
  • The reduction unit is one of the most important components for railway vehicles because the torque of the motor must be transmitted to the wheels of the vehicle by the reduction unit. The faults in the reduction units of high-speed trains are caused by damage such as gear, fatigue. These have serious impacts on safety of the train during operation. To address this development of a system for monitoring, fault diagnosis of the reduction unit is needed to keep the vehicle running safely. Before that can be accomplished, it is most important to understand the vibration characteristics of the reduction unit in a normal state. Vibration diagnosis technology using characteristic-analysis of vibration waveform and frequency is known to be the most effective method for fault diagnosis. In this paper, we analyzed the vibration characteristics of the reduction units two Korean high-speed trains (KTX and KTX II), under normal conditions, by two test methods (driving gear test, full-vehicle test).

Vibration Reduction of Pipe Line in Air-conditioner for Railway Vehicle (철도차량용 냉방기 배관계의 진동저감 연구)

  • You, Won-Hee;Jung, Yong-Ho;Koo, Jeong-Seo
    • Transactions of the Korean Society for Noise and Vibration Engineering
    • /
    • v.22 no.10
    • /
    • pp.925-931
    • /
    • 2012
  • The air-conditioner for railway vehicle should have vibration durability in order to operate normally in vehicle running situation. KS R 9144(vibration test methods for railway vehicle parts) is used to verify the vibration durability. The specifications of compressor, condenser and evaporator for air-conditioner in railway vehicle are standardized, but the shape and structure of pipe lines are not specified. Because the air-conditioner handler produces the pipe line arbitrarily, sometimes the pipe line is broken during the vibration durability test. In this research the cause identification and solution of pipe line breaking problem in during the vibration durability test were studied for air-conditioner of railway vehicle(diesel multiple unit). It was found that the natural frequency of pipe line is related to the pipe line breaking by experiment. A new pipe line shape was introduced by using FEA in order to avoid the resonance. The prototype new pipe line was applied to air-conditioner and the natural frequency was measured by experiment in order to verify the resonance avoidance. The vibration reduction of air-conditioner with new pipe line was reviewed by comparing to the air-conditioner with original one.

An Experimental Study on the Vibration Reduction of the 4WD Vehicle by the Engine Mounting Conditions (엔진장착조건에 따른 4WD 자동차의 진동저감에 대한 실험적 연구)

  • Sa, J.S.;Kim, K.S.
    • Transactions of the Korean Society of Automotive Engineers
    • /
    • v.2 no.2
    • /
    • pp.24-32
    • /
    • 1994
  • This paper is the experimental study on the vibration reduction of the 4WD vehicle through the change of the engine mounting conditions.(4 stroke diesel engine) The engine mounting conditions are changed to reduce the transmitted vibrations of the engine to the frame at the idle speed. Under the assumption that the Powertrain(Engine Transmission and Transfer Case) is a rigid body, the inertia properties of the powertrain are obtained by experimental modal analysis. And then the changed mounting conditions are studied by the decoupled vibration theory and analytical model of six degree of freedom. Though the mounting conditions are changed to improve the vibration isolation at idle speed, the vibration and the interior noise of the vehicle are reduced significantly at driving speed as well as idle speed. From the indirect endurance test of the front engine mounts, the changed mounting conditions are desirable to endurance as well as vibration reduction of the 4WD vehicle.

  • PDF