• 제목/요약/키워드: Reduction Time

Search Result 8,062, Processing Time 0.033 seconds

Active Control Methods for Drag Reduction in Flow over Bluff Bodies (뭉툭한 물체 주위 유동에서 항력 감소를 위한 능동 제어 방법)

  • Choi Haecheon
    • Proceedings of the KSME Conference
    • /
    • 2002.08a
    • /
    • pp.11-16
    • /
    • 2002
  • In this paper, we present two successful results from active controls of flows over a circular cylinder and a sphere for drag reduction. The Reynolds number range considered for the flow over a circular cylinder is 40-3900 based on the free-stream velocity and cylinder diameter, whereas for the flow over a sphere it is $10^{5}$ based on the free-stream velocity and sphere diameter. The successful active control methods are a distributed (spatially periodic) forcing and a high-frequency (time periodic) forcing. With these control methods, the mean drag and lift fluctuations decrease and vortical structures are significantly modified. For example, the time-periodic forcing at a high frequency (larger than 20 times the vortex shedding frequency) produces $50{\%}$ drag reduction for the flow over a sphere at $Re=10^{5}$. The distributed forcing applied to the flow over a circular cylinder results in a significant drag reduction at all the Reynolds numbers investigated.

  • PDF

Synthesis of Nano Metal Powder by Electrochemical Reduction of Iron Oxides

  • Seong, Ki-Hun;Lee, Jai-Sung
    • Proceedings of the Korean Powder Metallurgy Institute Conference
    • /
    • 2006.09a
    • /
    • pp.482-483
    • /
    • 2006
  • Synthesis of iron nanopowder by room-temperature electrochemical reduction process of ${\alpha}-Fe_2O_3$ nanopowder was investigated in terms of phase evolution and microstructure. As process variables, reduction time and applied voltage were changed in the range of $1{\sim}20$ h and $30{\sim}40$ V, respectively. From XRD analyses, it was found that volume of Fe phase increased with increasing reduction time and applied voltage, respectively. The crystallite size of Fe phase in all powder samples was less than 30 nm, implying that particle growth was inhibited by the reaction at room temperature. Based on the distinct equilibrium shape of crystalline particle, phase composition of nanoparticles was identified by TEM observation.

  • PDF

Mo Powders Fabricated from MoO3 by Reduction in Hydrogen Gas

  • Hong, Seonghoon;Lee, Changsup;Oh, Changsup;Kil, Sangcheol;Kim, Yongha
    • Korean Journal of Metals and Materials
    • /
    • v.50 no.6
    • /
    • pp.445-448
    • /
    • 2012
  • We studied the effect of temperature and reaction time by investigating the various temperatures and reaction times in the reduction of molybdenum oxide ($MoO_3$) to molybdenum (Mo) powder in hydrogen gas. We also studied the effect of the reaction of reduction according to the various hydrogen gas flow rates. We surveyed the reduction from molybdenum oxide to molybdenum powder in hydrogen gas and checked two temperature ranges, one from $400^{\circ}C$ to $600^{\circ}C$ and the other from $700^{\circ}C$ to $900^{\circ}C$. We found that the reaction ratio of molybdenum oxide increased with an increasing temperature and also increased with an increasing reaction time, but hydrogen gas did not influence the reduction ratio of molybdenum oxide. We examined molybdenum powders fabricated by ball milling for two hours, using with X-ray diffraction (XRD) and a scanning electron microscopy (SEM).

Comparison of Time Analysis on the Film Based System Versus PACS in the CT Scanning (CT 검사에서 시간분석에 의한 필름시스템과 PACS의 비교 연구)

  • Kweon, Dae-Cheol;Hong, Sung-Man;Park, Peom
    • IE interfaces
    • /
    • v.15 no.4
    • /
    • pp.439-443
    • /
    • 2002
  • In this paper, we study to evaluate the relative time required to perform the CT scanning in the PACS versus a film-based system and helical versus non-helical studies. Time studies were performed in 175 consecutive CT scanning. Images from 85 examinations were electronically transferred to a PACS, and 90 were printed to film. The time required to obtain and electronically transfer the images or print the images to film and make the current and previous studies available to the radiologists for interpretation was recorded. The time required for a radiological technologist to complete a CT test was reduced by 43% with the PACS compared with the film-based system and nonhelical was reduced 10~20% with helical studies. This reduction was due to the elimination of a transfer and printing, such as the printing at window or level settings. The use of PACS can result in the elimination of time tasks for the radiological technologist, resulting in marked reduction in examination time. This reduction can result in decreased cost and increased productivity in PACS operation.

Comparison of Time study in Film-based versus PACS : Computed Tomography (시간분석법에 의한 필름시스템과 PACS의 비교 연구 : CT촬영을 중심으로)

  • Kweon, Dae-Cheol;Jeong, Woo-Jin;Chung, Kyung-Mo;Lee, Yong-Woo;Lee, Je-Ho
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.5 no.1
    • /
    • pp.78-84
    • /
    • 2002
  • To evaluate the relative time required to perform a CT(computed tomography) examination in a filmless versus a film-based system and helical versus nonhelical studies. Time and Motion studies were performed in 175 consecutive CT examinations. Images from 85 examinations were electronically transferred to a PACS, and 90 were printed to film. The time required to obtain and electronically transfer the images or print the images to film and make the current and previous studies available to the radiologists for interpretation was recorded. The time required for a radiological technologist to complete a CT examination was reduced by 43% with the PACS compared with the film-based system and nonhelical was reduced 10-20% with helical studies. This reduction was due to the elimination of a transfer and printing, such as the printing at window or level settings. The use of PACS can result in the elimination of time tasks for the radiological technologist, resulting in marked reduction in examination time. This reduction can result in decreased cost and increased productivity in PACS operation.

  • PDF

Comparative analysis of the wind characteristics of three landfall typhoons based on stationary and nonstationary wind models

  • Quan, Yong;Fu, Guo Qiang;Huang, Zi Feng;Gu, Ming
    • Wind and Structures
    • /
    • v.31 no.3
    • /
    • pp.269-285
    • /
    • 2020
  • The statistical characteristics of typhoon wind speed records tend to have a considerable time-varying trend; thus, the stationary wind model may not be appropriate to estimate the wind characteristics of typhoon events. Several nonstationary wind speed models have been proposed by pioneers to characterize wind characteristics more accurately, but comparative studies on the applicability of the different wind models are still lacking. In this study, three landfall typhoons, Ampil, Jongdari, and Rumbia, recorded by ultrasonic anemometers atop the Shanghai World Financial Center (SWFC), are used for the comparative analysis of stationary and nonstationary wind characteristics. The time-varying mean is extracted with the discrete wavelet transform (DWT) method, and the time-varying standard deviation is calculated by the autoregressive moving average generalized autoregressive conditional heteroscedasticity (ARMA-GARCH) model. After extracting the time-varying trend, the longitudinal wind characteristics, e.g., the probability distribution, power spectral density (PSD), turbulence integral scale, turbulence intensity, gust factor, and peak factor, are comparatively analyzed based on the stationary wind speed model, time-varying mean wind speed model and time-varying standard deviation wind speed model. The comparative analysis of the different wind models emphasizes the significance of the nonstationary considerations in typhoon events. The time-varying standard deviation model can better identify the similarities among the different typhoons and appropriately describe the nonstationary wind characteristics of the typhoons.

Studies on Rapid Microbiological Testing Method of Fresh Pork by Applied Resazurin Reduction Test(RRT) Method (Resazurin 환원법을 응용한 돈육의 신속 미생물 검사법에 관한 연구)

  • Lim, S.D.;Kim, K.S.
    • Journal of Animal Science and Technology
    • /
    • v.44 no.4
    • /
    • pp.453-458
    • /
    • 2002
  • In order to search for reliable rapid methods of estimating bacterial counts in pork, this study was tried to measure resazurin reduction time which is simple in experimental method, low in analytical cost, able to estimate bacterial count within short time. The results were summarized as follows; Correlation coefficient between initial bacterial log count(25$^{\circ}C$/72hr, Y) and resazurin reduction time(X) from blue color to pink color during incubation at 25$^{\circ}C$ and 30$^{\circ}C$ was higher than other conditions as -0.95 and -0.94, respectively. Considering correlation coefficient and reduction time, incubation temperature was compatible at 30$^{\circ}C$, and regression equation(RE) was Y = -0.4386X + 7.7870. At a bacterial load of $10^2$cfu/$cm^2$, $10^3$cfu/$cm^2$ and $10^4$cfu/$cm^2$ in pork, reduction time was 13.2hr, 10.9hr and 8.6hr, respectively. Correlation coefficient between initial bacterial log count(30$^{\circ}C$/72hr, Y) and resazurin reduction time(X) from blue color to pink color during incubation at 30$^{\circ}C$ was highest among other conditions as -0.93, and RE was Y = -0.4171X + 7.5540. At a bacterial load of $10^2$cfu/$cm^2$, $10^3cfu/$cm^2$ and $10^4cfu/$cm^2$ in pork, reduction time was 13.3hr, 10.9hr and 8.5hr, respectively. Correlation coefficient between initial bacterial log count(35$^{\circ}C$/72hr, Y) and resazurin reduction time(X) from blue color to pink color during incubation at 30$^{\circ}C$ was highest among other conditions as -0.93, and RE was Y = -0.3514X + 6.7513. At a bacterial load of $10^2$cfu/$cm^2$, $10^3$cfu/$cm^2$ and $10^4$cfu/$cm^2$ in pork, reduction time was 13.5hr, 10.7hr and 7.8hr, respectively.

Noise Reduction Using the Standard Deviation of the Time-Frequency Bin and Modified Gain Function for Speech Enhancement in Stationary and Nonstationary Noisy Environments

  • Lee, Soo-Jeong;Kim, Soon-Hyob
    • The Journal of the Acoustical Society of Korea
    • /
    • v.26 no.3E
    • /
    • pp.87-96
    • /
    • 2007
  • In this paper we propose a new noise reduction algorithm for stationary and nonstationary noisy environments. Our algorithm classifies the speech and noise signal contributions in time-frequency bins, and is not based on a spectral algorithm or a minimum statistics approach. It relies on calculating the ratio of the standard deviation of the noisy power spectrum in time-frequency bins to its normalized time-frequency average. We show that good quality can be achieved for enhancement speech signal by choosing appropriate values for ${\delta}_t\;and\;{\delta}_f$. The proposed method greatly reduces the noise while providing enhanced speech with lower residual noise and somewhat higher mean opinion score (MOS), background intrusiveness (BAK) and signal distortion (SIG) scores than conventional methods.

A PRACTICAL LOOK AT MONTE CARLO VARIANCE REDUCTION METHODS IN RADIATION SHIELDING

  • Olsher Richard H.
    • Nuclear Engineering and Technology
    • /
    • v.38 no.3
    • /
    • pp.225-230
    • /
    • 2006
  • With the advent of inexpensive computing power over the past two decades, applications of Monte Carlo radiation transport techniques have proliferated dramatically. At Los Alamos, the Monte Carlo codes MCNP5 and MCNPX are used routinely on personal computer platforms for radiation shielding analysis and dosimetry calculations. These codes feature a rich palette of variance reduction (VR) techniques. The motivation of VR is to exchange user efficiency for computational efficiency. It has been said that a few hours of user time often reduces computational time by several orders of magnitude. Unfortunately, user time can stretch into the many hours as most VR techniques require significant user experience and intervention for proper optimization. It is the purpose of this paper to outline VR strategies, tested in practice, optimized for several common radiation shielding tasks, with the hope of reducing user setup time for similar problems. A strategy is defined in this context to mean a collection of MCNP radiation transport physics options and VR techniques that work synergistically to optimize a particular shielding task. Examples are offered in the areas of source definition, skyshine, streaming, and transmission.

A study on Linear Pattern Fabrication of Plate-type Polymer by Using Thermal Nano Imprint Lithography Process (열간나노임프린트공정을 이용한 평판형 폴리머 소재의 선형 패턴 제작에 관한 연구)

  • Joung, Y.N.;Lee, C.S.;Youn, S.W.;Kang, C.G.
    • Transactions of Materials Processing
    • /
    • v.18 no.8
    • /
    • pp.616-624
    • /
    • 2009
  • In this work we demonstrate the hot-embossing process under different forming conditions such as forming temperature, load, and holding time in pressing, in order to determine the suitable conditions required for linear patterning on polymer plates (PC). Results showed that the replicated pattern depth increased in proportion to an increase in the forming temperature, load, and time. The reduction of the workpiece thickness increased according to the holding time in the pressing process. In the process of time, the reduction ratio of the workpiece thickness decreased due to the surface area increment of the workpiece, while the pressure on the workpiece declined. In order to reduce the bulging ratio we introduced a temperature difference between the upper and the lower punch.