• Title/Summary/Keyword: Reduction Rate Test

Search Result 808, Processing Time 0.024 seconds

An Investigation of Performance Change of Diesel Oxidation Catalyst for Diesel Vehicle (경유차 적용 디젤산화촉매장치의 성능 변화 분석)

  • Hwang, Jin-Woo;Lee, Chang-Sik
    • Journal of ILASS-Korea
    • /
    • v.14 no.1
    • /
    • pp.15-19
    • /
    • 2009
  • This paper is to investigated the analysis of performance characteristics of diesel oxidation catalyst (DOC) for diesel vehicle with 2.5L piston displacement. The performance evaluation test of DOC applied to test diesel vehicle was carried out for four kinds of DOCs manufactured from different company. The testing DOCs were randomly selected from the retrofit vehicle and then standard test vehicle that was representative for the application group was equipped with DOC for the test. In this verification test, the reduction rate of particulate matter (P.M.) and the deviation of the performance of the DOC were examined through CVS-75 mode of the standard vehicle and SOF reduction rate of specific DOC was investigated. It was found that some DOCs failed to pass the criteria of the P.M. reduction rate because of the reason seen catalyst aging even if they were same devices. In the result of SOF analysis, the specific DOC showed more PM reduction than SOF of PM. reduction exceptionally.

  • PDF

A Study about Reduction Rate of Wetsuit Patterns for Men in their 30's (국내 30대 남성용 웨트수트 패턴 축소율에 관한 연구)

  • Choi, Jin-Hee
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.35 no.9
    • /
    • pp.1039-1048
    • /
    • 2011
  • This research develops a basic design structure for scuba diving wetsuits suitable for the shape of Korean men in their 30's as well as enhances the reduction rate for underwater activity. The clothing pressure and fitness tests were performed using four different types of body suits. The usable data of the tests were coded for further statistical analysis that includes one way-ANOVA test and S-N-K Multiple Range Test by using SPSSWIN 17.0. An analysis of the results shows: (1) The results of the clothing pressure test (using a dummy) indicated that the larger the reduction rate, the stronger the clothing pressure gets (with an exception on the knee area). It has great impact on clothing pressure with regards to the different body parts. The different reduction rates should be applied to body parts accordingly. (2) In the case of test subjects, the overall mean values of the clothing pressure were lower than the ones with the dummy (attributable to the cushion function of body skin and muscle as well as the high stretch of the fabric). (3) In evaluating the subjective fit test of four types of body suits, a statistically significant difference was found in the relation between pattern reduction rates and all parts of the body. It was revealed that the reduction rate of 'B' pattern (X: 4%, Y: 3%) was the most suitable pattern and the 'B' pattern scored highest in the motion functional fit test performed by a test subject.

Characterization of SCR System for NOx Reduction of Diesel Engine (II) (디젤엔진의 질소산화물 저감을 위한 Urea SCR 시스템 특성 분석 (II))

  • Lee, Joon-Seong;Kim, Nam-Yong
    • Journal of the Korean Society for Precision Engineering
    • /
    • v.25 no.11
    • /
    • pp.83-89
    • /
    • 2008
  • The Effect of Space Velocity(SV) on NOx conversion rate was performed to develop NOx reduction after-treatment system. SV is calculated from engine exhaust gas volume and SCR catalyst volume. Found the Urea injection duty of maximum efficiency for NOx conversion if increase SV, NOx Conversion rate is down. Especially, when SV is more than $110,000h^{-1}$, NOx conversion rate decrease suddenly. Same case, if SV is lower than $40,000h^{-1}$, NOx conversion rate is down. Also, the characterization of Urea-SCR system was performed. Three candidate injectors for injecting Urea were tested in terms of 속 injection rate and NOx reduction rate. The performances of SCR catalytic converter on temperature were investigated. The performance of Urea-SCR system was estimated in the NEDC test cycle with and without EGR. It was found that nozzle type injector had high NOx conversion rate. SCR catalytic converter had the highest efficiency at the temperature of $350^{\circ}C$. EGR+Urea-SCR system achieved NOx reduction efficiency of 73% through the NEDC test cycle.

Development of Tight-fitting Upper Clothing for Measuring ECG -A Focus on Weft Reduction Rate and Subjective Assessment- (심전도 측정을 위한 밀착 의복 연구 -패턴 축소 및 주관적 평가를 중심으로-)

  • Jeong, Yeonhee;Yang, YoungMo
    • Journal of the Korean Society of Clothing and Textiles
    • /
    • v.36 no.11
    • /
    • pp.1174-1185
    • /
    • 2012
  • This study develops tight-fitting upper clothing to measure electrocardiography (ECG) data. Taking into consideration the elasticity of the clothing, we made 4 experimental clothes by applying to each a weft reduction rate of 40%, 50%, 60%, and 70%. The 4 experimental clothes were used to measure resting ECG, exercise ECG, and post-exercise ECG for 4 men in their 20s. We compared clothing pressures using sensors on the human body and on a dressform. Subjective wear sensations of the 4 experimental clothes were evaluated using a subjective 7-point scale (with 7 being most excellent). We measured clothing pressures by using the air type pressure (AMI 3037-2) for upper and lower chest sensors in the developed tight-fitting upper clothing. The lower chest sensor showed that the clothing pressure on a human body and dressform changed consistently as the weft reduction rate decreased. The upper chest sensor showed inconsistent changes in clothing pressure as the weft reduction rate decreased. The wearing-test result for preliminary subjects showed that the lower chest sensor was more stable than the upper chest sensor; therefore, we inserted the sensor at the lower chest position before performing ECG. Except for Subject 4, the resting ECGs were stably measured for 3 subjects (Subject 1, Subject 2, and Subject 3) in all the developed clothes (A clothing, B clothing, C clothing, and D clothing). However, D clothing showed stable ECG values after exercise. The results of the experiment showed that we could measure ECG without difficulty using clothes with a weft reduction rate of 40% when the movement was not intense; however, tight-fitting upper clothing with a weft reduction rate of 70% was necessary to measure exercise ECG and post-exercise ECG values.

The Effects of Environmental Conditions on the Reduction Rate of TNT by $Fe^0$ (환경요인이 $Fe^0$ 에 의한 TNT의 환원 반응속도에 미치는 영향)

  • 배범한
    • Proceedings of the Korean Society of Soil and Groundwater Environment Conference
    • /
    • 2000.05a
    • /
    • pp.52-55
    • /
    • 2000
  • The effects of environmental conditions, initial dissolved oxygen concentrations, pH, and the presence of electron carrier vitamin B$_{12}$ , on the reduction rate of TNT by Fe$^{0}$ was Quantitatively analyzed using a batch reactor. In all experiments, TNT reduction was best described with a first order reaction and the reduction rate decreased with the increase in the initial DO concentration. However, the specific reaction rate did not decrease linearly with the increase in the initial DO concentration. In the presence of HEPES buffer 0.2 and 2.0 mM(pH 5.7$\pm$0.2), the specific reaction rate increased more than 5.8 times, which showed reduction rate is rather significantly influenced by the pH of the solution. To test the possibility of reaction rate enhancement, well-known electron carrier(or mediator), vitamin B$_{12}$ has augmented besides Fe$^{0}$ . In the presence of 8.0 $\mu\textrm{g}$/L of vitamin B$_{12}$ , the specific reaction rate increased as much as 14.6 times. The results indicate that the addition of trace amount of vitamin B$_{12}$ can be a promising rate controlling option for the removal of organics using a Fe$^{0}$ filled permeable reactive barrier.

  • PDF

Emission Characteristics of LP Gas Burner for the Variation of Combustion Conditions (연소조건 변화에 따른 LP가스버너의 배기특성)

  • 이병곤;오택흠
    • Journal of the Korean Society of Safety
    • /
    • v.16 no.4
    • /
    • pp.1-6
    • /
    • 2001
  • An experimental study was carried out to investigate the emission characteristics of LP gas burner for the Practical combustion conditions including fm voltage, inlet area, gas Pressure, emission resistance, duct length and height. The result shows that CO is almost remains constant for the emission fan voltage, but significantly increases with the reduction rate of air inlet, up to 3000ppm at 50% of reduction rate. Also, the variation of gas pressure has no effect to CO of gas boiler due to its governor which controls gas pressure secondly, but it gives an rapid increase of CO for the gas range. The emission resistance test shows that CO is suddenly increased with the reduction rate of emission duct above 70% and main burner is stopped at 90%. The reverse wind test shows that CO is suddenly increased with the air velocity above 7m/s and main burner is stopped at 9m/s. The more horizontal length of emission duct is long and the vertical height is low, CO is infinitesimally increased.

  • PDF

Analysis of Environmental Factors Affecting on the Reduction Rate of Land Compensation in Urban Development Project (도시개발사업의 토지부담률에 영향을 미치는 환경적 요인분석)

  • Koo, Ja-Kon;Sun, Jong-Geun;Jung, Min-Jung;Hong, Ji-Yeon
    • KIEAE Journal
    • /
    • v.11 no.2
    • /
    • pp.3-8
    • /
    • 2011
  • This study was carried out for analysing the relationship of environmental factors and the reduction rate of land compensation of six urban development projects near waste landfill sites located in the Seoul metropolitan area. For a close investigation, 24 variables were selected but only 4 environmental variables were identified to have high correlation to the reduction rate of compensation. These are fine particles(PM10), bad smell, the ratio of a greening zone of land and park, and the distance in straight line from the landfill site. Two variables-PM10 and bad smell-were found to have an effect on the average reduction rate of land compensation by correlation analysis. On the other hand, the ratio of a greening zone and the distance in straight line from the landfill site have been rejected for the significance test. The result of regression analysis of six models for the search of affecting variables on the reduction rate of compensation is that PM10 and bad smell have the impact ratio of more than 0.5. But the ratio of greening zone and the distance from the landfill are not significant factors, having the impact ratio of 0.025~0.045 except one model.

Study on the 2,4,6-Trinitrotoluene reduction rate by mediation of extracellular material of mixed culture (혼합배양 미생물의 세포외 물질이 2,4,6-Trinitrotoluene 변환에 미치는 영향에 관한 연구)

  • 한기봉
    • Journal of environmental and Sanitary engineering
    • /
    • v.11 no.2
    • /
    • pp.27-31
    • /
    • 1996
  • 2,4,6-Trinitrotoluene(TNT) was reduced into intermediate products by mixed culture incubated in anaerobic condition. To test the effects of extracellular material to electron transfer between sulfide and TNT, filtered medium of mixed culture was loaded in the test tubes with TNT and sulfide. The transformation rate was measured under four different conditions. The rate under microbial activity was the fastest among under different conditions. With sulfide or filtrate alone and TNT, the reactions were measured as the slowest reactions or no reactions occured, respectively. The reaction rate coefficient were calculated by linear regression and the first order kinetic was fitted best. Also, the plot of rate coefficients (K$_{f}$) showed linear relationships when at time zero TNT and sulfide concentration were 20 mg/1 and 6.0 mM, respectively. By extrapolation, reaction rate coefficient of 100% filtrate could be calculated as 0.0054/minute. However, reaction rate was affected by different concentration of sulfide, so it is a dependent of sulfide concentration. The results of this test showed TNT reduction rate can be limited more by microbial reaction than by mediation of filtrate or sulfide and filtrate alone.

  • PDF

The Dyeing Properties and The Functionality of Fabrics Dyed with Chelidonium Majus Extract (백굴채 추출물을 이용한 염색직물의 염색성 및 기능성)

  • Park, Young-Hee
    • Fashion & Textile Research Journal
    • /
    • v.10 no.2
    • /
    • pp.242-248
    • /
    • 2008
  • This study was aimed to find whether the Chelidonium majus which grows naturally in Korean soil and has a various medical ingredient is valuable as a natural dyeing material and to examine the functionality of Chelidonium majus extract. As the test result of dyeing colorfastness, colorfastness to sunlight was 1st grade for all the dyed fabrics. The colorfastness to laundry for discoloration showed from 1st to 4th grade and that for discoloration showed from 4th to 5th grade through all the dyed fabrics. Colorfastness to perspiration, rubbing, and drycleaning showed from 4th to 5th grade through all the dyed fabrics. In the result of antibiosis test, the dyed cotton fabric showed the bacteria reduction rate of 99.0% for Staphylococcus aureus and Escherichia coli evenly when washed one, three, and five times, The dyed silk fabric, when washed one, three, and five times, showed the bacteria reduction rate of 99.0% for Staphylococcus aureus, but didn't showed the significant bacteria reduction. As the test result of sun protection test, in the case of the cotton fabric which was dyed but don't use mordant, after one-time washing, S.P.F.(Sun Protection Factor) showed 20.4, the interception rate of UV-A showed 94.3%, and that of UV-B showed 95.2%. After five-time washing, S.P.F. showed 14.3, the interception rate of UV-A showed 90.0%, and that of UV-B showed 93.2%. In the case of the silk fabric which was dyed but don't use mordant, after one time washing, S.P.F. showed 30.5, the interception rate of UV-A showed 95.9%, and that of UV-B showed 96.9%, after five-time washing, S.P.F. showed 31.0, the interception rate of UV-A showed 95.6%, and that of UV-B showed 96.7%.

RTS test study and numerical simulation of mechanical properties of HDR bearings

  • Peng, Tianbo;Wu, Yicheng
    • Earthquakes and Structures
    • /
    • v.13 no.3
    • /
    • pp.299-307
    • /
    • 2017
  • High Damping Rubber bearings (HDR bearings) have been used in the seismic design of bridge structures widely in China. In earthquakes, structural natural periods will be extended, seismic energy will be dissipated by this kind of bearing. Previously, cyclic loading method was used mainly for test studies on mechanical properties of HDR bearings, which cannot simulate real seismic responses. In this paper, Real-Time Substructure (RTS) test study on mechanical properties of HDR bearings was conducted and it was found that the loading rate effect was not negligible. Then the influence of peak acceleration of ground motion was studied. At last test results were compared with a numerical simulation in the OpenSees software framework with the Kikuchi model. It is found that the Kikuchi model can simulate real mechanical properties of HDR bearings in earthquakes accurately.