• 제목/요약/키워드: Recycle system

Search Result 360, Processing Time 0.024 seconds

A Study on the Optical Internal Recycle Rate and MLSS Concentration of Membrane Coupled $A_2O$ Process for Wastewater Treatment (하수처리를 위한 막결합형 $A_2O$공정에서 최적 내부 순환율 및 MLSS 농도에 관한 연구)

  • Kim Kwan-Yeop;Kim Jin-Mo;Kim Hyung-Soo;Lee Sang-Bek;Park Eugene;Bae Sung-Soo
    • Membrane Journal
    • /
    • v.15 no.2
    • /
    • pp.114-120
    • /
    • 2005
  • The purpose of this study is to obtain practical information about membrane coupled $ A_2O$ system for muncipal wastewater treatment. A flat-plate microfiltration (MF) module with a pore size $0.25\;{\mu}m$ was submerged into the aeration basin and treated water was filtrated through the membrane by continuous suction with low pressure. The system was operated with synthetic wastewater to find operational parameters of internal recycle ratio and maximum MLSS showing best water quality and long-term stability. The internal recycle was defined as type 1 for aerobic to anoxic tank and type 2 for anoxic to anaerobic tank, respectively When the flux was maintained at $0.015\;m^3/m^2/hr$ (15 LMH) with 2Q type 1 internal recycle ratio, the optimal operational setting were 10 internal recycle ratio for type 2 and maximum MLSS of 11,000 mg/L among tested conditions. At this condition, removal efficiencies of BOD, CODcr, T-N and T-P showed $97.3\%,\;94.2\%,\;64.0\%,\;63.0\%$, respectively.

Integrated System of RBC-lime Precipiatation for Simultaneous Removal of Organics and Nutrients (회전원판공정과 화학침전공정 조합을 이용한 유기물과 질소*인의 동시제거)

  • 박종안;허준무;손부순
    • Journal of Environmental Health Sciences
    • /
    • v.24 no.1
    • /
    • pp.132-140
    • /
    • 1998
  • Laboratory-scale experiments were conducted using a three-stage rotating biological contactor unit followed by lime precipitation and sedimentation with effluent recycle to the first stage. The purpose of this study was to evaluate the effects of hydraulic loadings of 0.031-0.076 $m^3/m^2/d and recycle ratio of 1 to 3 on the simultaneous removal of organics and nutrients from domestic wastewater. Lime was added to maintain pH of 10.4-11.0 in the coagulation-flocculation reactor. Results showed that the highest nitrogen removal rate of 70.5% occurred at the lower hydraulic loading of 0.031 $m^3/m^2/d at a recirculation rate of 300%, and similarly, highest nitrification occurred at the same hydraulic loading and recycle ratio. Concentration of ammonia nitrogen in the effluent was less than 1 mg/l at the same operating conditions for higher nitrogen removal. Whereas, high BOD and COD removal was observed at hydraulic loading rate of 0.054 $m^3/m^2/d, and high removal of organic matter was evident from the consistent low COD and BOD value. Results obtained from the operating condition of higher loading rate, 300% of recycle rate showed the highest removals. Increasing in recycle rate and hydraulic loading rate increased the volatile solids fraction of the sludges generated to the extent of 47% at 0.076 $m^3/m^2/d hydraulic loading and 300% recirculation rate. Since pH in the flocculator was maintained at the pH of 10.4-11.0, above 90% removal of phosphorus was obtained. Average concentration of suspended solids was always maintained over 40 mg/l in the effluent. Therefore an RBC unit operating at a hydraulic loading near 0.031 $m^3/m^2/d with a recycle rate of 300% is a viable and feasible alternate conditions to produce an effluent with relative low organic matter and phosphorus, provided that there is a neutralization unit to control the pH and SS of the effluent.

  • PDF

Characteristics of Denitrification from Municipal Wastewater Treatment using a Combined Fixed Film Reactor (CFFR) Process (복합생물막 반응기를 이용한 하수처리시 탈질화 특성)

  • 이종현;남해욱;김영규;박태주
    • Journal of Environmental Science International
    • /
    • v.8 no.1
    • /
    • pp.107-113
    • /
    • 1999
  • A new biological nutrient removal system combining $A^2/O$ process with fixed film was developed in this work and the characteristics of denitrification were especially investigated in the combined fixed film reactor(CFFR). Media was added in the anaerobic, anoxic and aerobic reactors, respectively. Tests were made to establish the effluent level of $NO_x-N$, COD, DO and nitrite effects on $NO_x-N$ removal in the CFFR by decreasing hydraulic retention time (HRT) from 10.0 to 3.5 hours and by increasing internal recycle ratio form 0% to 200%. The influent was synthesized to levels similar to the average influent of municipal wastewater treatment plants in Korea. SARAN media with a porosity of 96.3% was packed 40% / 130% / 25% based on its reactor volume, respectively. It was found that COD rarely limited dentrification in the anoxic reactor because of high $C/NO_x/-N$ ratio in the anoxic reactor, while DO concentration in the anoxic reactor and $NO_2-N/NO_x/-N$ from the aerobic effluent inhibited denitrification in the anoxic reactor. It was proved that the critical points of DO concentration in the anoxic reactor and $NO_2-N/NO_x/-N$ from the aerobic effluent were 0.15mg/L and 10%, respectively. As the internal recycle ratio increased, DO concentration in the anoxic reactor and $NO_2-N/NO_x/-N$ from the aerobic effluent increased. Especially, at the condition of internal recycle ratio, 200%, DO concentration in the anoxic reactor and $NO_2-N/NO_x/-N$ from the aerobic effluent exceeded the critical points of 0.15mg/L and 10%, respectively. Then, denitrification efficiency considerably decreased. Consequently, it was represented that the control of DO concentration in the anoxic reactor and $NO_2-N/NO_x/-N$ from the aerobic effluent can assure effective denitrification.

  • PDF

Improvement of the Cooling Radiator System for Vehicles (차량용 라디에이터의 성능향상에 관한 연구)

  • Lee, Chang-Kyoo;Lee, Sang-Woo;Huh, Yun-Kun
    • Korean Journal of Agricultural Science
    • /
    • v.33 no.2
    • /
    • pp.107-114
    • /
    • 2006
  • An all-aluminum radiator made of aluminum was more excellent on environment friendliness, productivity, and cooling efficiency than the plastic tank radiator which was currently widely used in same size as above. A newly designed and manufactured radiator with all parts made of aluminium was ready to re-use without any disassembly process in recycle system so as to improve environment friendliness with low waste cost. Several manufacturing processes of the current plastic tank radiator such as O-ring inserting, and clinching of core to the tank, were eliminated on the manufacturing processes of the all-aluminium radiator, which would increase productivity and reduce production cost. Design criterion of all-aluminum radiator was presented by carrying out theoretical analysis of cooling capacity and there was no difference between analytical data and measurements. Cooling capacity of the all-aluminum radiator increased generally 13% up compared with the plastic radiator even though the pressure drop of air increased.

  • PDF

Collision Efficiency Estimation in the DAF Contact Zone using Computational Fluid Dynamics (전산유체 기법을 이용한 용존공기부상법에서의 접촉도 조건변화에 따른 충돌효율평가)

  • Kim, Sung-Hoon;Yoo, Je-Seon;Park, Hee-Kyung
    • Journal of Korean Society of Water and Wastewater
    • /
    • v.18 no.2
    • /
    • pp.201-207
    • /
    • 2004
  • Dissolved air flotation (DAF) is a solid-liquid separation process that uses fine rising bubbles to remove particles in water. Most of particle-bubble collision occurs in the DAF contact zone. This initial contact considered by the researchers to play a important role for DAF performance. It is hard to make up conceptual model through simple mass balance for estimating collision efficiency in the contact zone because coupled behavior of the solid-liquid-gas phase in DAF system is 90 complicate. In this study, 2-phase(gas-liquid) flow equations for the conservation of mass, momentum and turbulence quantities were solved using an Eulerian-Eulerian approach based on the assumption that very small particle is applied in the DAF system. For the modeling of turbulent 2-phase flow in the reactor, the standard $k-{\varepsilon}$ mode I(liquid phase) and zero-equation(gas phase) were used in CFD code because it is widely accepted and the coefficients for the model are well established. Particle-bubble collision efficiency was calculated using predicted turbulent energy dissipation rate and gas volume fraction. As the result of this study, the authors concluded that bubble size and recycle ratio play important role for flow pattern change in the reactor. Predicted collision efficiency using CFD showed good agreement with measured removal efficiency in the contact zone. Also, simulation results indicated that collision efficiency at 15% recycle ratio is higher than that of 10% and showed increasing tendency of the collision efficiency according to the decrease of the bubble size.

A Study on characteristics of AUC Powder Prepared with the Waste AC Solution (폐 AC용액으로부터 제조된 AUC분말의 특성에 대한 연구)

  • 정경채;김태준;최종현;박진호
    • Journal of the Korean Ceramic Society
    • /
    • v.33 no.3
    • /
    • pp.332-338
    • /
    • 1996
  • This study was investigated on the recycle feasibility of the waste AC(Ammonium Carbonate) solution produ-ced in a commercial AUC(Ammonium Uranyl Carbonate) conversion plant. AUC particles were produced with the AC solution which was prepared with AC solid-agent instead of ammonia and carbon-dioxide gases. As the results particles of monoclinic shapes has been obtained regardless of the pH change if the carbonate concentration is sufficient in the mother liquore. Also a lot of twinned or aggregated particles were formed in case of the increase of pH in the reaction system but not affected in the change of temperature. Consequen-tly the characteristics of the particles which converted for AUC were produced withAC solution to UO2, particles specific surface area shape sintered density and others were similar to that of the particles which were produced with gases only when the pellets are fabricated in the nuclear fuel manufacturing process So the waste AC solution which is produced in the commercial AUC conversion plant is possible to recycle.

  • PDF

Coagulation and Flotation Conditions of Humic Acid by Dissolved Air Flotation

  • Lee, Chang-Han
    • Journal of Environmental Science International
    • /
    • v.21 no.9
    • /
    • pp.1043-1051
    • /
    • 2012
  • Coagulation, flocculation, and dissolved air flotation (DAF) experiments were performed with humic acid to evaluate the influence of operational conditions on removal efficiencies. We investigated coagulation, flocculation, and flotation conditions of humic acid removal using a laboratory-scale DAF system. This paper deals with coagulant type (aluminum sulfate and PSO-M) and the most relevant operational conditions (velocity gradients for coagulation and flocculation, retention time and recycle ratio and flotation time). Results showed that optimal conditions for removing humic acid, yielding CHA removal efficiencies of approximately 85 %, are a recycle ratio of 40 %, coagulant dosages of 0.15 - 0.20 gAl/gHA as aluminum sulfate and 0.03 - 0.12 gAl/gHA as PSO-M, coagulation($400s^{-1}$ and 60s), flocculation($60s^{-1}$ and 900s or more), and flotation(490 kPa or more and at least 10 min).

Simultaneous N-P Removal of Wastewater with Flow Variation by Anaerobic-Aerobic Activated Sludge Process(I) (혐기-호기 활성슬러지법에 의한 유량변동이 있는 폐수의 N-P 동시 제거에 관한 연구(I))

  • 이민규;서근학
    • Journal of Environmental Science International
    • /
    • v.4 no.5
    • /
    • pp.509-516
    • /
    • 1995
  • The treatment performances of anaerobic-aerobic activated sludge process were investigated under various operation conditions. The treatment system proposed in this study gave a relatively stable performance against hourly change of the flow rate and showed a satisfactory removal of nitrogen and phosphorus compounds under experimental conditions. The recycle ratio of mixed liquor from aerobic to anaerobic region and peak coefficient primarily controlled the extent of nitrogen removal. The recycle ratio had the optimum values which were determined by the microbial activities of nitrification and denitrification. The behavior of the treatment unit could be simulated by using the kinetic equations and reactor models which considered the treatment units as complete mixing tanks.

  • PDF

Simultaneous N-P Removal of Wastewater with Flow Variation by Anaerobic-Aerobic Activated Sludge Process(I) (혐기-호기 활성슬러지법에 의한 유량변동이 있는 폐수의 N-P 동시 제거에 관한 연구(I))

  • Lee, Min-Gyu;Suh, Kuen-Hack
    • Journal of Environmental Science International
    • /
    • v.4 no.5
    • /
    • pp.123-123
    • /
    • 1995
  • The treatment performances of anaerobic-aerobic activated sludge process were investigated under various operation conditions. The treatment system proposed in this study gave a relatively stable performance against hourly change of the flow rate and showed a satisfactory removal of nitrogen and phosphorus compounds under experimental conditions. The recycle ratio of mixed liquor from aerobic to anaerobic region and peak coefficient primarily controlled the extent of nitrogen removal. The recycle ratio had the optimum values which were determined by the microbial activities of nitrification and denitrification. The behavior of the treatment unit could be simulated by using the kinetic equations and reactor models which considered the treatment units as complete mixing tanks.

Combustion Characteristics of Wood Chips(Flame Shape of Combustion and Ignition Delay) (목재의 연소 특성(2)(연소형태와 연소특성))

  • Kim, Chun-Jumg;ARAI, Masataka;Kang, Kyung-Koo
    • Journal of the Korean Society of Industry Convergence
    • /
    • v.2 no.2
    • /
    • pp.139-146
    • /
    • 1999
  • Combustion Characteristics of the wood chips(balsa chips) were experimental studied as fundamental investigation of the thermal recycle system of the urban dust. The urban dust contains plastics vegetable and lot of wood material. Then, a wood was chosen as an example of the component of urban dust. A small wood chip was burned in a electric furnace and mass reduction rate during volatile and combustion states were recorded by the micro-electric balance and the combustion flame shape took a photograph by video camera at the mass of wood chips and ambient temperature in the furance. Ignition delay took the minimum value when the mass of the test chip was 0.3g. When a mass of the test chip was smaller then 0.001g, combustion with flame did not burnt.

  • PDF