• Title/Summary/Keyword: Rectifier efficiency

검색결과 351건 처리시간 0.018초

Load Dispatching Control of Multiple-Parallel-Converters Rectifier to Maximize Conversion Efficiency

  • Orihara, Dai;Saitoh, Hiroumi;Higuchi, Yuji;Babasaki, Tadatoshi
    • Journal of Electrical Engineering and Technology
    • /
    • 제9권3호
    • /
    • pp.1132-1136
    • /
    • 2014
  • In the context of increasing electric energy consumption in a data center, energy efficiency improvement is strongly emphasized. In a data center, electric energy is largely consumed by DC power supply system, which is based on a rectifier composed by multiple parallel converters. Therefore, rectifier efficiency must be improved for minimizing loss of DC power supply system. Rectifier efficiency can be modulated by load allocation to converters because converter efficiency depends on input AC power. In this paper, we propose a new control method to maximize rectifier efficiency. The method can control load allocation to converters by introducing active power converter control scheme and start-and-stop of converters. In order to illustrate optimal load allocations in a rectifier, a maximization problem of rectifier efficiency is formulated as a nonlinear optimization one. The problem is solved by Lagrangian relaxation method and the computation results provide the validity of proposed method.

무선 에너지 전송을 위한 정류회로에 관한 연구 (Study on the Rectifier Circuits for Wireless Energy Transmission)

  • 신두섭;서철헌
    • 대한전자공학회논문지TC
    • /
    • 제48권2호
    • /
    • pp.90-94
    • /
    • 2011
  • 본 논문에서는 고주파 대역 중에서 에너지 전송과 관련되어 정류 회로의 구조와 특성을 분석하고, 최대의 효율을 이끌어 낼 수 있는 방안을 찾고자 한다. 13.56MHz에서의 입력 신호를 DC 변환하여 실험 및 측정을 하였다. 정류회로는 반파 정류회로, 전파정류회로 브릿지 정류회로로 나눌 수 있고, 최대 효율을 갖기 위해서 다양한 정류 회로를 전산 모의 실험하였다. 현재까지의 연구 내용은 passive 소자를 이용한 효율 개선에 중점을 두고 실험을 하였다. 정류 효율에 영향을 미치는 요소는 소자의 특성에 좌우하며, 이번 실험에서는 약 70%의 효율을 측정할 수 있었으며, 보다 개선된 소자를 사용함으로서 낮은 입력에서 높은 효율을 얻을 수 있었다.

Rectifier Design Using Distributed Greinacher Voltage Multiplier for High Frequency Wireless Power Transmission

  • Park, Joonwoo;Kim, Youngsub;Yoon, Young Joong;So, Joonho;Shin, Jinwoo
    • Journal of electromagnetic engineering and science
    • /
    • 제14권1호
    • /
    • pp.25-30
    • /
    • 2014
  • This paper discusses the design of a high frequency Greinacher voltage multiplier as rectifier; it has a greater conversion efficiency and higher output direct current (DC) voltage at high power compared to a simple halfwave rectifier. Multiple diodes in the Greinacher voltage multiplier with distributed circuits consume excited power to the rectifier equally, thereby increasing the overall power capacity of the rectifier system. The proposed rectifiers are a Greinacher voltage doubler and a Greinacher voltage quadrupler, which consist of only diodes and distributed circuits for high frequency applications. For each rectifier, the RF-to-DC conversion efficiency and output DC voltage for each input power and load resistance are analyzed for the maximum conversion efficiency. The input power with maximum conversion efficiency of the designed Greinacher voltage doubler and quadrupler is 3 and 7 dB higher, respectively;than that of the halfwave rectifier.

PFC 스위칭 정류기에서 손실인자에 의한 내부손실과 효율분석에 관한 연구 (A Study on the Internal Loss and Efficiency Analysis by Loss Factors in PFC Switching Rectifier)

  • 안태영
    • 반도체디스플레이기술학회지
    • /
    • 제23권2호
    • /
    • pp.50-54
    • /
    • 2024
  • In this paper, we propose a theoretical method to systematically analyze the power conversion efficiency of a single-phase PFC switching rectifier. Boost-type PFC was organized in order of highest correlation with load current using steady-state analysis results and introduced the concept of loss factor. The loss factors for each major element are summarized and presented in a table. This paper makes it easier to understand the internal loss and power conversion efficiency of the rectifier for loss factors. Lastly, to confirm the validity of the efficiency analysis results reflecting the loss factors, loss and efficiency analysis of the 2.5kW PFC rectifier was performed. The results were compared with data from a 2.5kW PFC circuit for evaluation. As a result, the usefulness of power conversion efficiency analysis reflecting the loss factors proposed in this paper was confirmed.

  • PDF

GaN FET를 적용한 인터리브 CRM PFC의 효율특성에 관한 연구 (A Study on the Efficiency Characteristics of the Interleaved CRM PFC using GaN FET)

  • 안태영;장진행;길용만
    • 전력전자학회논문지
    • /
    • 제20권1호
    • /
    • pp.65-71
    • /
    • 2015
  • This paper presents the efficiency analysis of a critical current mode interleaved PFC rectifier, in which each of three different semiconductor switches is employed as the active switch. The Si FET, SiC FET, and GaN FET are consecutively used with the prototype PFC rectifier, and the efficiency of the PFC rectifier with each different semiconductor switch is analyzed. An equivalent circuit model of the PFC rectifier, which incorporates all the internal losses of the PFC rectifier, is developed. The rms values of the current waveforms main circuit components are calculated. By adapting the rms current waveforms to the equivalent model, all the losses are broken down and individually analyzed to assess the conduction loss, switching loss, and magnetic loss in the PFC rectifier. This study revealed that the GaN FET offers the highest overall efficiency with the least loss among the three switching devices. The GaN FET yields 96% efficiency at 90 V input and 97.6% efficiency at 240 V, under full load condition. This paper also confirmed that the efficiency of the three switching devices largely depends on the turn-on resistance and parasitic capacitance of the respective switching devices.

동기 정류기를 이용한 위상 변위 제어 클램프 모드 포워드 다중 공진형 컨버터 (Phase Shift Controlled GM ZVS-MRC with Synchronous Rectifier)

  • 송종화;김창선;김희준
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1997년도 하계학술대회 논문집 F
    • /
    • pp.2016-2019
    • /
    • 1997
  • To solve the low efficiency problem of low-voltage power supplies, it has been studied to replace the schottky barrier diode with the MOSFET synchronous rectifier. In this paper, Phase Shift-Controlled Clamp Mode Zero Voltage Switching-Multi Resonant Converter with Synchronous Rectifier (PSC CM ZVS-MRC with SR) is presented to achieve high efficiency in low-voltage power supplies. The characteristics analysis of synchronous rectifier is established by using the MOSFET equivalent circuit and efficiency comparison is established between the Synchronous Rectifier and the schottky barrier diode. To verify the validity of the analysis, 33W(3.3V, 10A) PSC CM ZVS-MRC with self-driven synchronous rectifier at switching frequency of 1MHz is designed and tested. And it is confirmed that the experimental results are well consistent with the theoretical results. The maximum efficiency of the converter is 83.4% at full load, which is 3.3% higher than conventional schottky diode rectification.

  • PDF

A High Efficiency Active Rectifier for 6.78MHz Wireless Power Transfer Receiver with Bootstrapping Technique and All Digital Delay-Locked Loop

  • Nga, Truong Thi Kim;Park, Hyung-Gu;Lee, Kang-Yoon
    • IEIE Transactions on Smart Processing and Computing
    • /
    • 제3권6호
    • /
    • pp.410-415
    • /
    • 2014
  • This paper presents a new rectifier with a bootstrapping technique to reduce the effective drop voltage. An all-digital delay locked loop (ADDLL) circuit was also applied to prevent the reverse leakage current. The proposed rectifier uses NMOS diode connected instead of PMOS to reduce the design size and improve the frequency respond. All the sub-circuits of ADDLL were designed with low power consumption to reduce the total power of the rectifier. The rectifier was implemented in CMOS $0.35{\mu}m$ technology. The peak power conversion efficiency was 76 % at an input frequency of 6.78MHz and a power level of 5W.

Low price Fuel Cell Inverter System for 3[KW] Residential Power

  • Kwon, Soon-Kurl
    • 조명전기설비학회논문지
    • /
    • 제21권4호
    • /
    • pp.61-72
    • /
    • 2007
  • This study proposed a high efficiency DC-DC converter with a new current doubler rectifier for fuel-cell systems for use with the Nexa(310-0027) PEMFC from the Ballard Co. The proposed high efficiency DC-DC converter for the fuel-cell system generated ZVS by applying partial resonance and using a phase shift PWM control method. Constantly switching frequency, loss of switching, peak current, and peak voltage were reduced by this system. In addition to this system, two inductors were attached to a rectifier circuit allowing it to be able to provide the direct current(DC) and DC voltage safely to a load with reduced ripple components. Also, by using the newly proposed current doubler rectifier, the high frequency DC-DC converter for the fuel cell system was capable of reaching a highest efficiency of 92[%] as compared to 88.3[%] efficiency in previous results, which means that efficiency increased 3.7[%]. The overall results were confirmed by a simulation and laboratory experiment.

Bridgeless Buck PFC Rectifier with Improved Power Factor

  • Malekanehrad, Mahdi;Adib, Ehsan
    • Journal of Power Electronics
    • /
    • 제18권2호
    • /
    • pp.323-331
    • /
    • 2018
  • Buck power factor correction (PFC) converters, compared with conventional boost PFC converters, exhibit high efficiency performance in the entire range of universal line voltage. This feature has gotten more attention for eliminating the zero crossing dead angle of buck PFC rectifiers. Furthermore, bridgeless structures for the reduction of conduction losses have been proposed. The aim of this paper is to introduce a single-phase buck rectifier that simultaneously has unity power factor (PF) and bridgeless structure while operating in the continuous conduction mode (CCM). For this purpose, two auxiliary flyback converters without any active switches are applied to a bridgeless buck rectifier to eliminate the zero crossing dead angle and achieve unity power factor, low total harmonic distortion (THD) and high efficiency. The operation and design considerations of the proposed rectifier are verified on a 150W, 48V prototype using a conventional peak-current-mode control. The measurement results show that the proposed rectifier has nearly unity power factor, THD less than 7% and high efficiency.

암모니아-물 흡수식 시스템에서 단열정류기의 물질 전달 (Mass transfer in adiabatic rectifier of ammonia-water absorption system)

  • 김병주
    • 설비공학논문집
    • /
    • 제11권3호
    • /
    • pp.414-421
    • /
    • 1999
  • Falling film rectification involves simultaneous heat and mass transfer between vapor and liquid interface. In the present work, the adiabatic rectification process of ammonia-water vapor on the vertical plate was investigated. The continuity, momentum, energy and diffusion equations for the solution film and vapor mixture were formulated in integral forms and solved numerically. The model could predict the film thickness, the pressure gradient, and the mass transfer rate. The effects of Reynolds number and ammonia concentration of solution and vapor mixture, rectifier length, and the enhancement of mass transfer in each phases were investigated. The stripping of water in vapor mixture occurred new the entrance of ammonia solution, which imposed the proper size of an adiabatic rectifier. Rectifier efficiency increased as film Reynolds number increased and as vapor mixture Reynolds number decreased. The improvement of rectifier efficiency was significant with the enhancement of mass transfer in falling film.

  • PDF