• Title/Summary/Keyword: Recovered paper

Search Result 606, Processing Time 0.028 seconds

A Retransmission Power Adjustment Scheme for Performance Enhancement in DS/SSMA ALOHA with Packet Combining

  • Seo Hanbyul;Park Seongyong;Lee Byeong Gi
    • Journal of Communications and Networks
    • /
    • v.7 no.1
    • /
    • pp.36-44
    • /
    • 2005
  • In this paper, we present a retransmission power adjustment (RPA) scheme for DS/SSMA ALOHA packet radio systems with packet combining. In the proposed RPA scheme, retransmission power is adjusted in such a way that the erroneously-received packet can be recovered with a minimized interference to other user packets. We analyze the performance of the system with the RPA by employing the equilibrium point analysis (EPA), and confirm that the results obtained from the EPA are very close to the simulation results in low power cases. Simulation results demonstrate that the RPA scheme brings forth performance gain in the throughput and the average delay while saving a significant amount of transmission power. We also investigate the stability of the system from the EPA results, and conclude that the system becomes stable as the offered load increases or the level of retransmission power decreases.

Development of High Performance Ozone Generating Controller (다중 펄스 방식에 의한 고성능 오존발생 제어장치 개발)

  • 이홍희;김형준
    • The Transactions of the Korean Institute of Electrical Engineers D
    • /
    • v.52 no.5
    • /
    • pp.226-226
    • /
    • 2003
  • When an excessive voltage is applied to the discharge gap in ozone generator, the discharge room temperature becomes higher. As is well own, the efficiency of the ozone generation is deteriorated by the excessively hot temperature because of the decomposition reaction. In this paper, the simple small capacity ozone generating controller has been introduced, which provides effective and stable silent discharge characteristics over wide range input power. The proposed power controller has two important advantages, which imply that the production rate of ozone can be controlled linearly according to the delivered power and the surplus energy is recovered to the source. The experimental results are given to verify the performance of the pre proposed controller.

A Segmentation Method for a Moving Object on A Static Complex Background Scene. (복잡한 배경에서 움직이는 물체의 영역분할에 관한 연구)

  • Park, Sang-Min;Kwon, Hui-Ung;Kim, Dong-Sung;Jeong, Kyu-Sik
    • The Transactions of the Korean Institute of Electrical Engineers A
    • /
    • v.48 no.3
    • /
    • pp.321-329
    • /
    • 1999
  • Moving Object segmentation extracts an interested moving object on a consecutive image frames, and has been used for factory automation, autonomous navigation, video surveillance, and VOP(Video Object Plane) detection in a MPEG-4 method. This paper proposes new segmentation method using difference images are calculated with three consecutive input image frames, and used to calculate both coarse object area(AI) and it's movement area(OI). An AI is extracted by removing background using background area projection(BAP). Missing parts in the AI is recovered with help of the OI. Boundary information of the OI confines missing parts of the object and gives inital curves for active contour optimization. The optimized contours in addition to the AI make the boundaries of the moving object. Experimental results of a fast moving object on a complex background scene are included.

  • PDF

Development of High Performance Ozone Generating Controller (다중 펄스 방식에 의한 고성능 오존발생 제어장치 개발)

  • 이홍희;김형준
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.52 no.5
    • /
    • pp.226-230
    • /
    • 2003
  • When an excessive voltage is applied to the discharge gap in ozone generator, the discharge room temperature becomes higher. As is well own, the efficiency of the ozone generation is deteriorated by the excessively hot temperature because of the decomposition reaction. In this paper, the simple small capacity ozone generating controller has been introduced, which provides effective and stable silent discharge characteristics over wide range input power. The proposed power controller has two important advantages, which imply that the production rate of ozone can be controlled linearly according to the delivered power and the surplus energy is recovered to the source. The experimental results are given to verify the performance of the pre proposed controller.

Development of an Optical Probe for Measuring Blood Flow in Dental Pulp (치수혈류 측정을 위한 광 프로브 개발)

  • Jang, Kyung-Hwan;Choi, Joon-Yul;Koo, Jeong-Mo;Kwon, Min-Kyung;Kim, Deok-Won
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.61 no.8
    • /
    • pp.1204-1209
    • /
    • 2012
  • To diagnose dental pulp vitality, electric pulp tester has been widely used, which is a method to test condition of nerve. However, especially in the case of patients with trauma, nerve desensitization could temporarily occur even though nerve might be recovered by blood flow within the pulp later, which implies that blood flow in dental pulp is also an important factor for diagnosing vitality. This paper described the development of a probe that relatively measured blood flow in dental pulp using photoplethysmography (PPG). The probe emits four different wavelength light sources including three visible and an infrared light. We tested which light source detect sensitively the blood flow in dental pulp. As a result, green light had the largest peak to peak voltage and the power spectrum among different wavelengths.

Magnetic Coupled ZVT PWM Boost PFC Pre-regulator (에너지 회생 변압기를 사용한 영전압 과도상태(ZVT) 부스트 역률보상 회로)

  • Yang Joon-Hyun;Lee Dong-Young;Cho Bo-Hyung
    • Proceedings of the KIPE Conference
    • /
    • 2001.07a
    • /
    • pp.548-551
    • /
    • 2001
  • A zero-voltage transition (ZVT) PWM boost PFC converter using a transformer to recover the resonant energy into the input voltage is proposed. The proposed converter reduces turn-off switching loss of the auxiliary switch. The resonant current of the auxiliary circuit is optimally reduced by the feed-forwarded input voltage. Moreover, the resonant energy of the auxiliary circuit is recovered into the load and input voltages. In this paper, the modes of converter operation are explained and analyzed, design guidelines are given, and experimental results of 1.2kW, 200kHz prototype system are presented.

  • PDF

Hiding Secret Data in an Image Using Codeword Imitation

  • Wang, Zhi-Hui;Chang, Chin-Chen;Tsai, Pei-Yu
    • Journal of Information Processing Systems
    • /
    • v.6 no.4
    • /
    • pp.435-452
    • /
    • 2010
  • This paper proposes a novel reversible data hiding scheme based on a Vector Quantization (VQ) codebook. The proposed scheme uses the principle component analysis (PCA) algorithm to sort the codebook and to find two similar codewords of an image block. According to the secret to be embedded and the difference between those two similar codewords, the original image block is transformed into a difference number table. Finally, this table is compressed by entropy coding and sent to the receiver. The experimental results demonstrate that the proposed scheme can achieve greater hiding capacity, about five bits per index, with an acceptable bit rate. At the receiver end, after the compressed code has been decoded, the image can be recovered to a VQ compressed image.

Two-Stage Charge Equalization Scheme for Hybrid Electric Vehicle Lithium-Ion Battery Cells

  • Park, Hong-Sun;Kim, Chong-Eun;Moon, Gun-Woo;Lee, Joong-hui
    • Proceedings of the KIPE Conference
    • /
    • 2007.07a
    • /
    • pp.241-243
    • /
    • 2007
  • Two-stage charge equalization scheme for HEV lithium-ion battery string is proposed with the optimal power rating design rule in this paper, where in the first stage the over charged energy of higher voltage cells is drawn out to the single common output capacitor and then, that discharged energy is recovered into the overall battery stack in the second stage. To achieve charge equalization of sort, the conventional flyback DC/DC converters of low power and minimized size are employed. The industrial sample employing both the proposed two-stage cell balancing scheme and the optimal power rating design rule shows good cell balancing performance with reduced size as well as low voltage stresses of the electronic devices.

  • PDF

Synchronous Visible Light Communication Systems Using 3-Level LED Modulation (3-Level LED 변조를 이용한 동기식 가시광통신 시스템)

  • Lee, Seong-Ho
    • Journal of Sensor Science and Technology
    • /
    • v.22 no.6
    • /
    • pp.421-427
    • /
    • 2013
  • In this paper, we introduce a new synchronous visible light communication system in which the synchronizing pulse and the data bits are simultaneously transmitted using a 3-level light signal. In the transmitter, the synchronizing pulse and the data bits modulate independently two identical visible LEDs, whose output lights add in free space, make 3-level optical signal. In the receiver, a photodiode detects the light and generates a 3-level output voltage, whose positive and negative part correspond to the synchronizing pulse and the data bits, respectively. The two signals are easily separated and recovered by a simple diode circuit. This configuration provides two independent VLC channels without any multiplexing technique, simplifies the circuit design and construction of synchronous VLC systems.

Power Regulation of Variable Speed Wind Turbines using Pitch Control based on Disturbance Observer

  • Joo, Young-Jun;Back, Ju-Hoon
    • Journal of Electrical Engineering and Technology
    • /
    • v.7 no.2
    • /
    • pp.273-280
    • /
    • 2012
  • Most variable speed wind turbines have pitch control mechanisms and one of their objectives is to protect turbines when the wind speed is too high. By adjusting pitch angles of wind turbine, the inlet power and the torque developed by the turbine are regulated. In this paper, the difference between the real wind speed and its rated value is regarded as a disturbance, and a component called disturbance observer (DOB) is added to the pre-designed control loop. The additional DOB based controller estimates the disturbance and generates a compensating signal to suppress the effect of disturbance on the system. As a result, the stability and the performance of the closed loop system guaranteed by an outer-loop controller (designed for a nominal system without taking into account of disturbances) are approximately recovered in the steady state. Simulation results are presented to verify the performance of the proposed control scheme.