• Title/Summary/Keyword: Recover ratio

Search Result 197, Processing Time 0.027 seconds

Effects of Modified Montmorillonite Nanocomposite on Growing/Finishing Pigs during Aflatoxicosis

  • Shi, Y.H.;Xu, Z.R.;Feng, J.L.;Xia, M.S.;Hu, C.H.
    • Asian-Australasian Journal of Animal Sciences
    • /
    • v.18 no.9
    • /
    • pp.1305-1309
    • /
    • 2005
  • Experiments were conducted to determine the efficacy of modified montmorillonite nanocomposite (MMN) to reduce the toxic effects of aflatoxin (AF) in growing/finishing pigs. 96 weaned pigs were assigned to four dietary treatment groups (0 g of MMN and 0 mg of AF/kg feed, 3 g of MMN/kg feed, 0.1 mg of AF/kg feed, and 3 g of MMN plus 0.1 mg of AF/kg feed). Body weight gain (BW gain), feed/gain ratio, serum biochemical values and enzyme activities were evaluated. Compared with the control, AF alone markedly reduced BW gain and resulted in a significantly higher feed/gain ratio. There were no differences in BW gain and feed/gain ratio between 0.3% MMN or 0.3% MMN plus AF and the control. These results suggested that the deleterious effects of AF were ameliorated by MMN addition. AF intake markedly increased relative organ weights of liver, kidney, spleen and pancreas, and resulted in significant alterations of serum parameters. However, these parameters for pigs fed diets containing MMN and AF returned to normal values, indicating that MMN had the ability to recover the AF-decreased performance, organ damage and to correct aberrations in serum parameters. These findings in our study suggested that MMN can effectively modulate the toxicity of AF in growing/finishing pigs and may offer a novel approach to the preventive management of aflatoxicosis in animals.

Recovery of Tin from Waste Tin Plating Solution by Ion Exchange Resin (주석도금폐액으로부터 이온교환수지를 이용한 주석 회수)

  • Shin, Gi-Wung;Kang, Yong-Ho;Ahn, Jae-Woo;Hyeon, Seung-Gyun
    • Resources Recycling
    • /
    • v.24 no.3
    • /
    • pp.51-58
    • /
    • 2015
  • In order to recover tin from the waste tin plating solution, we used the ion exchange method using three types of ion exchange resins. The ion exchange resin with tertiary functional group(Lewatit TP 272) has not adsorption ratio of tin. The ion exchange resin with iminodiacetic functional group(Lewatit TP 207) has high adsorption ratio of tin, but impurity content in the recovered tin solution was relatively high. Whereas, in case of the ion exchange resin with functional group of ethylhexyl-phosphate(Lewatit VP OC 1026), adsorption ratio of tin was less than that of Lewatit TP 207. However, it was possible to remove impurities in the recovered tin solution by controlling the pH of the solution. High purity tin solution can be recovered by removing the organic materials with water washing process.

Changes in Interests in the Korean Traveling Industry of International Visitor at the Post-Covid 19 by Analysis of Frequency in searching keyword (키워드 검색 빈도 분석을 통한 포스트 코로나 시대 외래관광객들의 한국 관광 관심도 변화)

  • Lee, Yongseol
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.26 no.9
    • /
    • pp.1399-1404
    • /
    • 2022
  • The transition to the untact era caused by the COVID-19 pandemic has greatly shrunk Korea's continuously growing tourism industry. In this paper, the size, gender ratio, and gender ratio of foreign tourists before and after the outbreak of Corona, gender ratio, It was noted that there was a very large change in the purpose of the visit. Considering the end of the mandatory outdoor mask, the lifting of the mandatory quarantine for all overseas arrivals regardless of vaccination, and the number of outbound tourists who started to recover rapidly from the first half of 2022, this thesis examines how the interest in Korean tourism in the post-corona era is I wanted to see if it had changed. To this end, we analyzed how major tourism-related search keywords changed before and after COVID-19, and suggested changes necessary for the development of the Korean tourism industry.

Study on Improving High-temperature Tolerance for Grain Filling Through Adjusting Sink Size (영화수 조절을 통한 벼 등숙기 고온내성 향상 연구)

  • Kim, Junhwan;Shon, Jiyoung;Choi, Kyung-Jin;Yoon, Younghwan;Lee, Chung-Kuen
    • KOREAN JOURNAL OF CROP SCIENCE
    • /
    • v.58 no.2
    • /
    • pp.107-112
    • /
    • 2013
  • The aim of this study was to test hypothesis that low sink size could mitigate deterioration of grain filling characteristics under high grain filling temperature. To achieve this aim, we selected Donganbyeo as a tolerant and Ilpumbyeo as susceptible variety to high temperature during grain filling period through screening 6 rice varieties. Then their spikelets number and the ratio of superior and inferior spikelet were compared. Grain weight and head rice ratio of Ilpumbyeo decreased significantly in high temperature. Ilpumbyeo had more spikelets than Donganbyeo. However, there was no significant difference between two varieties in the ratio of superior and inferior spikelets. So we tried to investigate the varietal difference of grain filling characteristics with removing inferior spikelets. Removing inferior spikelet in both of varieties could recover grain weight but not improve head rice ratio under high temperature. These results showed that sink/source ratio affected grain weight but didn't affect head rice ratio. Therefore, new approach was required to improve head rice ratio beyond sink/source ratio under high temperature.

Evaluation of Minimum Spiral Reinforcement Ratio of Circular RC Columns (철근콘크리트 원형기둥의 나선철근 최소철근비에 대한 평가)

  • Kim, Young-Seek;Kim, Hyeong-Gook;Park, Cheon-Beom;Kim, Sang-Woo;Kim, Kil-Hee
    • Journal of the Korea institute for structural maintenance and inspection
    • /
    • v.21 no.6
    • /
    • pp.1-9
    • /
    • 2017
  • Spiral reinforcement in a circular column plays an effective role in the ductile behavior of a column through position fixing and buckling restraining of the longitudinal reinforcement, and confining core-concrete. Each country has suggested the minimum volumetric ratio of spiral reinforcement in order to secure the ductility of concrete columns. The minimum volumetric ratio of spiral reinforcement suggested by ACI 318-14 and the national concrete structure design standard was developed based on the theory of Richard et al. (1928); furthermore it has been used until now. However, their theory cannot consider the effects of high strength concrete and high strength reinforcement, and arrangement condition of the spiral reinforcement. In this study, a modified minimum volumetric ratio equation is suggested, which is required to improve the ductility of reinforced concrete circular columns and to recover their stress. The modified minimum volumetric ratio equation suggested here considers the effect of the compressive strength of concrete, the yield strength of spiral reinforcement, the cross sectional area of columns, the pitch of spiral reinforcements and the diameter of spiral reinforcement. In this paper, the validity of the minimum volumetric ratios from ACI 318-14 and this study was investigated and compared based on the results of uniaxial compression experiment for specimens in which the material strength and the spiral reinforcements ratio were used as variables. In the end of the study, the modification method for the suggested equation was examined.

Postoperative Changes of Pulmonary Function in Chest Surgery (개흉후 폐기능 변화에 대한 연구)

  • Jo, Gwang-Jo;Jeong, Hwang-Gyu
    • Journal of Chest Surgery
    • /
    • v.25 no.11
    • /
    • pp.1169-1179
    • /
    • 1992
  • To determine the period and degree of full recovery of postoperative pulmonary function, the author performed seiral pulmonry function test with spirometry at preoperative period and 1st, 2nd, 3rd, 4th, 6th and 8th postoperative week in 64 patients who underwent chest surgery form 1990. 1. to 1990. 8. at Dep. of Thoracic & Cardiovascular surgery, Pusan National University Hospitcal, Pusan, Korea 28 patients underwent lung resection[Group A], 14 patients mediastinal and other thoracic surgery[Group B], and 22 patients heart surgery with cardiopulmonary bypass[Group C]. Al of them recovered normally and discharged without any complications. Their serial changes of pulmonary function test were compaired and its results was as follows; l. Over all mean recovery time of restrictive ventilatory function tests[ie, VC, ERV, IC, FEF1, FVC, FEF200-1200, MVV] were 4th & 6th postoperative week, and that of obstructive ventilatory function tests[ie., EFE25-75%, Vmax50] were 2nd postoperative week. 2. In patient who underwent lung resection surgery[Group A], FEF1 recovered in 4th~6th postoperative week and its ratio to preoperative value was 70% in pneumonectomy, and 75% in lobectomy. FVC recovered in 4th~6th postoperative week and its ratio to preoperative value was 65% in pneumonectomy, and 80% in lobectomy. MVV was recovered in 4th~8th postoperative week and recovery ratio was 80%, FEF200-1200 was recovered at 4th~6th postoperative week and its recovery ratio was 70%, FEF25-75% and Vmax50 was recovered in 2nd~4th postoperative week and recovered nearly to preoperative level. 3. In patient who underwent mediastinal and other thoracic surgery[Group B], FEV1 and FVC and recovered in 4th~6th postoperative week and the recovery ratio of FVC in blebectomy was 90%. MVV reached preoperative level in 4th~8th postoperative week. FEF200-1200, FEF25-75% and Vmax50 were recovered in 2nd~4th postoperative week and the recovery of FEF25-75% and Vmax50 in blebectomy was prominant. 4. In patient who underwent heart surgery[Group C], FEV1 and FVC were recovered in 4th~6th postoperative week. The recover ratio of FEF25-75% and Vmax50 was delaied to 6th~8th postoperative week From the above results we concluded that the recovery time of posoperative restrictive ventilatory disorder was 4th postoperative week and pulmonary complication would possibly occure during that period. So more intensive observations will be needed.

  • PDF

Current Limiting and Voltage Sag Compensation Characteristics of Flux-Lock Type SFCL Using a Transformer Winding (변압기 권선을 이용한 자속구속형 초전도 전류제한기의 전류제한 및 전압강하 보상 특성)

  • Ko, Seok-Cheol
    • Journal of the Korean Institute of Electrical and Electronic Material Engineers
    • /
    • v.25 no.12
    • /
    • pp.1000-1003
    • /
    • 2012
  • The superconducting fault current limiter (SFCL) can quickly limit the fault current shortly after the short circuit occurs and recover the superconducting state after the fault removes and plays a role in compensating the voltage sag of the sound feeder adjacent to the fault feeder as well as the fault current limiting operation of the fault feeder. Especially, the flux-lock type SFCL with an isolated transformer, which consists of two parallel connected coils on an iron core and the isolated transformer connected in series with one of two coils, has different voltage sag compensating and current limiting characteristics due to the winding direction and the inductance ratio of two coils. The current limiting and the voltage sag compensating characteristics of a SFCL using a transformer winding were analyzed. Through the analysis on the short-circuit tests results considering the winding direction of two coils, the SFCL designed with the additive polarity winding has shown the higher limited fault current than the SFCL designed with the subtractive polarity winding. It could be confirmed that the higher fault current limitation of the SFCL could be contributed to the higher load voltage sag compensation.

QoS Based IrDA in Mobile Phones

  • Kim Jong Sung;Yoon Sang Sub;Chun Byung Sik
    • Proceedings of the IEEK Conference
    • /
    • 2004.08c
    • /
    • pp.528-531
    • /
    • 2004
  • This paper presents the design and implementation of a QoS based IrDA in mobile phones. The IrDA standards have arised from the need to connect various mobile devices together. But currently, we have a difficult to connecting various mobile devices together. The difficult thing is to adjust the minimum turn around time. The minimum turn around time in IrDA deals with the time needed for a receiver circuit to recover following saturation by transmissions from the same device (turn around latency). This parameter corresponds to the required time delay between the last byte of the last frames sent by a station and the point at which it is ready the first byte of a frame from another station. This parameter comes into play when the link is turned around and is negotiated independency for each station. We solve this matter by using the Dynamic Adjustment Algorithm (DAA). The dynamic adjustment algorithm adjusts the minimum turn around time according to the numbers of devices. We apply our direct adjustment algorithm to our QoS based IrDA in mobile phones and show the improved performance of connection with various mobile phones together.

  • PDF

Comparative Exergy Analysis of Kalina and Organic Rankine Cycles for Conversion of Low-Grade Heat Source (저등급 열원의 변환을 위한 칼리나 사이클과 유기 랭킨 사이클의 엑서지 성능의 비교 해석)

  • KIM, KYOUNG HOON;JUNG, YOUNG GUAN;KO, HYUNG JONG
    • Journal of Hydrogen and New Energy
    • /
    • v.31 no.1
    • /
    • pp.105-111
    • /
    • 2020
  • The organic Rankine cycle (ORC) and the Kalina cycle system (KCS) are being considered as the most feasible and promising ways to recover the low-grade finite heat sources. This paper presents a comparative exergetical performance analysis for ORC and Kalina cycle using ammonia-water mixture as the working fluid for the recovery of low-grade heat. Effects of the system parameters such as working fluid selection, turbine inlet pressure, and mass fraction of ammonia on the exergetical performance are parametrically investigated. KCS gives lower lower exergy destruction ratio at evaporator and higher second-law efficiency than ORC. The maximum exergy efficiency of ORC is higher than KCS.

Application of Blind Deconvolution with Crest Factor for Recovery of Original Rolling Element Bearing Defect Signals (볼 베어링 결함신호 복원을 위한 파고율을 이용한 Blind Deconvolution의 응용)

  • Son, Jong-Duk;Yang, Bo-Suk;Tan, A.C.C.;Mathew, J.
    • Proceedings of the KSME Conference
    • /
    • 2004.11a
    • /
    • pp.585-590
    • /
    • 2004
  • Many machine failures are not detected well in advance due to the masking of background noise and attenuation of the source signal through the transmission mediums. Advanced signal processing techniques using adaptive filters and higher order statistics have been attempted to extract the source signal from the measured data at the machine surface. In this paper, blind deconvolution using the eigenvector algorithm (EVA) technique is used to recover a damaged bearing signal using only the measured signal at the machine surface. A damaged bearing signal corrupted by noise with varying signal-to-noise (s/n) was used to determine the effectiveness of the technique in detecting an incipient signal and the optimum choice of filter length. The results show that the technique is effective in detecting the source signal with an s/n ratio as low as 0.21, but requires a relatively large filter length.

  • PDF