• Title/Summary/Keyword: Reciever

Search Result 17, Processing Time 0.023 seconds

Interference Aware Receiver Filtering for Wireless Ad Hoc Networks (무선 애드혹 네트워크에서의 간섭 제어 수신 기법)

  • Shin, Sungpil;Lee, Byungju;Park, Sunho;Shim, Byonghyo
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.50 no.3
    • /
    • pp.9-15
    • /
    • 2013
  • Recent works on ad hoc network study have shown that achievable throughput can be made to scale linearly with the number of receive antennas even if the transmitter has only a single antenna. In this paper, we propose a non-parametric linear minimum mean square error (MMSE) receiver for achieving further gain in performance when the channel state information at receiver (CSIR) of interferers is imperfect. The key feature to make our approach effective is to exploit the autocorrelation of the received signal. In fact, by incorporating the desired channel information on top of the observations including interference and noise only, the proposed method achieves large fraction of the optimal MMSE transmission capacity without transmission rate loss. From the SINR analysis as well as transmission capacity simulations in realistic ad hoc network system, we show that the proposed non-parametric linear MMSE receiver brings substantial performance gain over existing multiple receive antenna algorithms.

A Study on the Stabilized System Operation Considering the Reflection Characteristic of an Active-Phased Array Antenna (능동 위상 배열 안테나의 반사 특성을 고려한 안정적 시스템 운용에 관한 연구)

  • Kim, Young-Wan;Chae, Hee-Duck;Lee, Dong-Kook;Jeong, Myung-Deok;Park, Jong-Kuk
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.23 no.1
    • /
    • pp.29-37
    • /
    • 2012
  • In this paper, a stabilizd system operation through a composition of a protective circuit and an improvement of active reflection coefficient(ARC) is studied. Unlike the passive-phased array antenna, the APPA is a combined form of radiating element and transmitter-reciever module. Therefore, a definition of new ARC that differentiates itself from typical passive-phased array antenna must apply. The ARC is a reflection coefficient considering a superposition of a coupling from nearby radiating elements and self reflection. It is an important parameter that predicts and analyzes charateristics of a APPR system. A high level ARC is a direct source inducing a performance degradation of a system. In this paper, as a method for a stabilized operation of APAR, one method for improving a performance and another for degradation prevention are analyzed. An effectiveness of two methods was validated using experiment results of real-fabricated active-phased array antenna.

A Analysis on wireless performance of unified data transmission in a subway and railway (18GHz 차지상간통합데이터전송 시스템의 지하 및 지상구간 무선특성 분석)

  • Jeong, Sang-Guk;An, Tae-Ki;Kim, Baek-Hyun;Choi, Gab-Bong
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.13 no.6
    • /
    • pp.1083-1090
    • /
    • 2009
  • In 18GHz using unified data transmission in a subway and railway, Influence of the multipath fading is big and an arrival range of the micro wave takes the influence greatly according to the transmit angle and receive angle because it not diffracted. This thesis analyzed microwave property underground tunnel and ground railway at unified data transmission in subway and railway. Antenna gain of directional antenna many used unified transmission in an subway and railway, is used 15dBi and 10dBi in simulation. Transmitter's property is compared underground tunnel to ground railway about curved railway of R=100, R=200, R=400. Specification of transmitter is used sample unified transmission system in subway and railway of KRRI(korea railroad research Institute). Transmitter's power is 20dBm and Reciever's sensitivity is -90dBm. According to result of simulation.

Development of Galileo E5 Signal Receiving Software for AltBoc Signal Modulation (AltBOC 변조 특성을 활용한 Galileo E5 신호 수신 소프트웨어 개발)

  • Jeon, Sang-Hoon;So, Hyoung-Min;Lee, Taik-Jin;Kim, Ghang-Ho;Jeon, Seung-Il;Kim, Chong-Won;Kee, Chang-Don;Lee, Sang-Uk;Kim, Jae-Hoon
    • Journal of the Korean Society for Aeronautical & Space Sciences
    • /
    • v.37 no.9
    • /
    • pp.855-862
    • /
    • 2009
  • This paper contains the signal receiving algorithm for Galileo E5 AltBOC signal and the development of Galileo E5 signal receiving software. The software runs the process from signal acquisition to extracting measurement data to get navigation solution. It uses logged IF data file as an input. In signal acquisition stage, 1ms and delayed 1ms data are used for reducing correlation ross from secondary code and navigation bit conversion. Signal tracking stage is made of two stages which are coarse tracking and fine tracking. It is for taking advantage of AltBOC characteristic and resolving ambiguity problem due to BOC modulation. The functions of software are verified by signal processing using logged IF data from commercial GNSS simulator.

Performance Evaluation of Frame Synchronization Using Pilot Patterns in W-CDMA System (W-CDMA 시스템의 파일럿 패턴을 이용한 프레임 동기 성능 분석)

  • Song Young-Joon;Kim Han-Mook
    • The Journal of Korean Institute of Electromagnetic Engineering and Science
    • /
    • v.17 no.3 s.106
    • /
    • pp.272-279
    • /
    • 2006
  • In this paper, we evaluate the performance of frame synchronization words of pilot bit patterns which are used for the channel estimation and frame synchronization confirmation in W-CDMA(Wide band Code Division Multiple Access) system. W-CDMA system also uses compressed mode to make measurements from another frequency without a full dual receiver terminal. It is confirmed by using computer simulation that the proposed frame synchronization words also maintain the frame synchronization property in the compressed mode by using the complementary mapping relationship of preferred pair ROC(Receiver Operating Characteristic) curves with probability of detection and false alarm are used to analized the performance of the proposed frame synchronization words by using the various detection metrics such as LLRT(Log Likelyhood Ratio Test), GLRT(Generalied Likelyhood Ratio Test), soft and hard correlation tests in AWGN and Rayleigh fading channels. It is expected that the research results fer the performance of pilot bit patterns of this paper can be useful reference for the design and implementation of frame synchronization in 3rd generation W-CDMA system.

A Study on the Accuracy of the Loran-C Fix of Korean Chain in Pusan Area (부산지역에서의 Loran-C 한국체인의 측위정도에 관한 연구)

  • 박주삼
    • Journal of the Korean Society of Fisheries and Ocean Technology
    • /
    • v.32 no.4
    • /
    • pp.372-380
    • /
    • 1996
  • The operation of Far East Chain(GRI 5970) of Loran - C system had been stopped on June, 1995, but that of Korean Chain(GRI 9930) of Loran - C system which was jointed with North West Pacific Chain(GRI 8930) and Russia Chain(GRI 7950) by international cooperation, was started on January 1996. In this paper, in order to study the accuracy of Loran - C fix of Korean Chain, the authors examined and analyzed the data of the reciever of Loran - C(LC -90, Furuno) and GPS(AccNav Sport super (TM), Eagle) measured automatically and continually for 2 seconds at interval of 5 minutes from November 22, 1992, to January 20, 1996 at the fixed position of National Fisheries University of Pusan, The results obtained were as follows ; 1)The mean time differences of M-W, M-X, and M-Y pair measured in the base observed position were 12333.09${\mu}$s, 28338.44${\mu}$s, and 42806.01${\mu}$s respectively and the mean standard deviations of that were 0.0121${\mu}$s, 0.0290${\mu}$s, and 0.0327${\mu}$s respectively. The daily and monthly variance forms of time difference at each pair appeared in a similar reappearance. 2)The mean standard deviations of the latitude and longitude by Loran - C were 9.1m and 17.4m in W.X pair, 11.5m and 13.7m in W.Y pair, and 8.1m and 29.3m in X.Y pair respectively, and then the probable radiuses within 95% of each pair were 39.2m, 35.7m, and 60.8m, respectively. Therefore, It is to be desired that W.Y par is selected to improve the accuracy in Pusan area. 3)The mean standard deviations of the latitude and longitude by GPS were 15.4m and 15.0m and the probable radius within 95% was 43.4m. 4)The position errors for GPS and each pair of Loran - C were 16.0m to the South in GPS and 265.2m to the East in W.X pair of Loran - C, 279.5m to the North in W.Y pair of that, and 224.3m to the North-West in X.Y pair of that, so GPS is about 250m higher than Loran - C in accuracy.

  • PDF

ROC Analysis of Visual Assessments Made in Gated Blood Pool Scans of Patients with Coronary Artery Disease (관상동맥질환에서 심장풀 스캔의 육안적 평가에 대한 ROC 분석)

  • Lee, Kyun-Han;Choi, Yoon-Ho;Lee, Bum-Woo;Moon, Dae-Hyuk;Koong, Sung-Soo;Chung, June-Key;Lee, Myung-Chul;Koh, Chang-Soon
    • The Korean Journal of Nuclear Medicine
    • /
    • v.23 no.2
    • /
    • pp.175-181
    • /
    • 1989
  • Visual assessment of regional wall motion abnormality (RWMA) by gated blood pol scan (GBPS) serves as an useful parameter in the diagnosis, functional evaluation, and follow up in various clinical settings, but are still subject to some inherent limitations. On important problem may be the interobserver as well as intraobsever variation that may well be present due to the subjective nature of the interpretations. This study was carried out to determine the reliability and reproducibility of visual assessments made in GBPSs, and to observe the degree to which the results would be influenced by observer variation. Fifty two patients with coronary heart disease had resting GBPS and contrast ventriculography within 4 days appall. Contrast ventriculography-showed normal wall motion in 6 patients and the remaining 46 had RWMA in one or more segments. The anterior and left anterolateral views of all 52 GBPSs were analyzed by three independent observers, who selected from 5 scales, their level of confidence that there was RWMA in that segment. Reciever operating characteristic (ROC) curves for each analysis was plotted and the area under the curve $(\theta)$ was used as a parameter representing each observer's performance in his interpretations. The findings of contrast ventriculographies were used as the standard for RWMA. The apical and inferoapical segments showed the best correlation with contrast ventriculography ($\theta=0.90-0.94$, 0.81-0.94, respectively), and the inferior wall showed the poorest correlation $(\theta=0.70-0.74)$. The interpretations of the inferior, septal, apical, and posteroinferior, segments showed no difference between the observers, but there was significantly better performance in assessment by observer A compared to that by B or C for the anterolateral segments ($\theta=0.87$, 0.78, 0.76, respectively. p<0.01 for A vs B, p<0.05 for A vs C), as well as when all segments were considered altogether ($\theta=0.88$, 0.83, 0.82, respectively. both p<0.05). This was also true for the infero-apical segment between A and C ($\theta=0.09$, 0.81, p<0.05). The intraobserver variation, however, did not appear significant, with only the inferior segment for observer B showing any significant difference when observer A and B repeated the analysis 10 days latter. There was no difference in assessing dyskinesia, with all observers showing a high performance ($\theta=0.98$, 0.87, 0.97, respectively). The visual assessment of left ventricular ejection fraction by all three observers correlated well with the calculated value from a semiautomated method (Spearman's r = 0.91, 0.83, 0.83. p<0.01, p<0.05, p < 0.05). The assessment of LV and RV size also correlated well between the three observers (Kendall's w = 0.80, 0.51, p<0.01 for both left and right ventricles). The above findings suggest that RWMA visually assessed by GBPS correlates well with that done by contrast ventriculography. And although the observer's experience or skill may influence the results in certain segments, visual analysis of GBPS may serve as a reliable and reproducible means for evaluating ventricular function.

  • PDF