• 제목/요약/키워드: Real-time hmi

Search Result 39, Processing Time 0.021 seconds

Implementation of C-HMI based Real-time Control and Monitoring for Remote Wastewater Reclamation and Reusing System (C-HMI 기반의 원격지 중수도 설비 실시간 제어와 모니터링 구현)

  • Lee, Un-Seon;Park, Man-Gon
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.62 no.5
    • /
    • pp.717-722
    • /
    • 2013
  • The wastewater reclamation and reusing system has been rising as an alternative of water resource exhaustion that the whole world is experiencing. In order to be able to bring about improvement of the existing wastewater reclamation and reusing system, this research has developed of Conversion-Human Machine Interaction (C-HMI) based real-time control and monitoring system such as a sensor module and gate module, web monitoring system. This system was communication almost-error-free in various environment and situation. As a result, we have achieved our goal that has to doing work correctly as a sensor and gateway module that communication error is less than 0.2% throughout the embodied system and add that it can be easily controled and configured as an interface equipment to a complex sensor of water quality. According to this, the construction of a database capable of analyzing and assessing collection, storage and various elements of reliable water quality and flow rate data can be possible.

Production Data Utilization System for Improving the Competitiveness of SMEs (중소기업 경쟁력 향상을 위한 생산현황 데이터 활용 시스템)

  • Lee, Seung-Woo;Nam, So-Jeong;Lee, Jai-Kyung
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.37 no.2
    • /
    • pp.55-61
    • /
    • 2014
  • Recently, the manufacturing system is being changed in a mass customization and small quantity batch production. MES is a powerful production management tool supporting production optimization from the process initiation to the final shipment. It is a production management system which plans and executes based on the production data in the shop floor. This study deployed the utilization of production data and web HMI system to process real-time production data through the collection with the shop floor. The developed system was applied to the equipment operating time and other production data could be processed with the real-time. The proposed system and web HMI can be applied for various production systems by using different logic.

InTouch HMI Development to Real-Time Power System Analysis (실시간 전력 계통 해석을 위한 InTouch HMI 구현)

  • Ahn, Chang-Han;Lee, Sang-Deok;Park, Ji-Ho;Chang, Byung-Hoon;Lee, Hyun-Chul;Lee, Geun-Joon;Baek, Young-Sik
    • The Transactions of The Korean Institute of Electrical Engineers
    • /
    • v.58 no.12
    • /
    • pp.2322-2327
    • /
    • 2009
  • Uncertainty of power system operation increases due to complexity and facilities diversification in the power system. Therefore the importance of SCADA(Supervisory Control and Data Acquisition) system which obtain and manage the actual data in real-time is very important. Accordingly in the studies of power system analysis, the efforts to include real-time power system analysis in simulation and applications are made in many ways. The real-time communication characteristics of SCADA system is considered so as to develop the power system analysis program that matches actual system conditions. The observation and management of SCADA system is realized by Intouch which is mainly used for factory automation and PSS/E(Power System Simulator for Engineers) provides real time system data. SQL DB and Python language is used for real-time communication between the softwares. It is very comfortable to use the various functions in Intouch WindowMaker.

Protocol Monitor System Between Cortex M7 Based PLC And HMI

  • Kim, Ki-Su;Lee, Jong-Chan;Ha, Heon-Seong
    • Journal of the Korea Society of Computer and Information
    • /
    • v.25 no.6
    • /
    • pp.17-23
    • /
    • 2020
  • In this paper, collecting real-time data frames that occur during RS232 communication between an HMI and PLC of automation equipment by sniffing real-time information data frames through MCU without modification of the HMI or PLC, a method is proposed that allows users to collect data without being dependent on the modification of PLC and HMI systems. The user collects necessary information from the sniffing data through the parsing operation, and the original communication interface is maintained by transmitting the corresponding sniffing frame to the destination. The MCU's UART communication interface circuit is physically designed according to the RS232 communication standard, and this additionally improves efficiency more so than an interrupt-based system by using the DMA device inside the MCU. In addition, the data frame IO operation is performed by logically separating the work of the DMA interrupt service routine from the work of the main thread using the circular queue. Through this method, the user receives the sniffing data frame between the HMI and PLC in RS232 format, and the frame transfer between PLC and HMI arrives normally at the original destination. By sniffing the data frame without further modification of the PLC and HMI, it can be confirmed that it arrives at the user system normally.

Function Expansion of Human-Machine Interface(HMI) for Small and Medium-sized Enterprises: Focused on Injection Molding Industries (중소기업을 위한 인간-기계 인터페이스(HMI) 기능 확장: 사출성형기업 중심으로)

  • Sungmoon Bae;Sua Shin;Junhong Yook;Injun Hwang
    • Journal of Korean Society of Industrial and Systems Engineering
    • /
    • v.45 no.4
    • /
    • pp.150-156
    • /
    • 2022
  • As the 4th industrial revolution emerges, the implementation of smart factories are essential in the manufacturing industry. However, 80% of small and medium-sized enterprises that have introduced smart factories remain at the basic level. In addition, in root industries such as injection molding, PLC and HMI software are used to implement functions that simply show operation data aggregated by facilities in real time. This has limitations for managers to make decisions related to product production other than viewing data. This study presents a method for upgrading the level of smart factories to suit the reality of small and medium-sized enterprises. By monitoring the data collected from the facility, it is possible to determine whether there is an abnormal situation by proposing an appropriate algorithm for meaningful decision-making, and an alarm sounds when the process is out of control. In this study, the function of HMI has been expanded to check the failure frequency rate, facility time operation rate, average time between failures, and average time between failures based on facility operation signals. For the injection molding industry, an HMI prototype including the extended function proposed in this study was implemented. This is expected to provide a foundation for SMEs that do not have sufficient IT capabilities to advance to the middle level of smart factories without making large investments.

Design and Implementation of Real-time Audio and Video System Using Red5 and Node.js (Red5와 Node.js를 활용한 실시간 음성 및 영상 시스템의 설계 및 구현)

  • Kim, Hyeock-Jin;Kwark, Woo-Young
    • Journal of the Korea Society of Computer and Information
    • /
    • v.19 no.10
    • /
    • pp.159-168
    • /
    • 2014
  • The Web is a way to share documents and communicate. However, voice and video data can be transmission in real time and currently being developed by the objects and the objects that interact to further develop the Internet. Existing video and audio programs to transmission data to the interface of different types of systems a lot of constraint condition on the cost of the interface, extensibility. In this paper, voice and audio transmission system a different operating system, improve the constraints of the ERP system compatibility and extensibility is a open source based system developed by the research. The program is different types of systems and interface, extensibility with program design and development methodologies, and open source-based system composed This system is good for cost saving and extensibility. Therefore, systems research and development, Extensibility and excellent on the interface, system design and development methodologies, such as real-time video conferencing, HMI, and take advantage of your video available from SNS.

Study of the Design of Data Acquisition and Analysis Systems for Multi-purpose Regional Energy Systems

  • Lee, Han-Sang;Yoon, Dong-Hee;Jang, Gil-Soo;Park, Jong-Keun;Park, Goon-Cherl
    • Journal of Electrical Engineering and Technology
    • /
    • v.5 no.1
    • /
    • pp.16-20
    • /
    • 2010
  • Recently, the smart grid has become a hot issue and interest in related power sources have increased accordingly. The implementation of a smart grid can enable many generation resources to be linked to the power system, including small-scale reactors for the purpose of co-generation. Research on small-scale reactors is being carried out all over the world. Similarly, Korea is also conducting research on multi-purpose regional energy systems using nuclear energy. This paper proposes a real-time data acquisition and analysis system for small-scale reactors, and is known as the REX-10 (Regional Energy rX 10 MVA). This analysis requires real-time simulations for the power system since it needs data communication with a remote REX-10. A RTDS (Real Time Digital Simulator) has been used for the simulation, and a SCADA/HMI system interfaced with the RTDS is proposed for the purpose of monitoring and control of the regional energy system.

3D HMI of Hydrogen Refueling Station Using Digital Twin (디지털트윈을 이용한 수소충전소의 3D HMI)

  • Hyeon-Jun Bae;Seoung-Uk Lee;Sung-Ho Hwang
    • The Journal of the Convergence on Culture Technology
    • /
    • v.10 no.5
    • /
    • pp.797-802
    • /
    • 2024
  • Hydrogen refueling station safety is the most vulnerable when installing, commissioning, and repairing hydrogen refueling station equipment. At this time, developing and providing a digital twin of a hydrogen refueling station can help install equipment, start-up, and repair failures. Digital twins are also required for event detection, cause analysis, and prediction during hydrogen refueling station operation. However, since the current SCADA HMI of hydrogen refueling stations consists of 2D, it is difficult for those who do not know the basic knowledge and composition status of hydrogen refueling stations to understand intuitively. In this paper, by introducing digital twin technology to hydrogen refueling stations and displaying the values measured at hydrogen refueling station equipment in real time in 3D, it is intended to help intuitively analyze and predict the occurrence, cause, and prediction of events at hydrogen refueling stations. For this purpose, data from SCADA HMI were extracted, transmitted to the digital twin, and provided an intuitive and easy-to-understand 3D environment in the digital twin so that non-professionals can easily grasp the operation status of the hydrogen refueling station.

Research of Real Time Monitoring System Development Using TCP/IP & RS-422 Communication (TCP/IP & RS-422 통신을 이용한 실시간 모니터링 시스템개발에 관한 연구)

  • 이주열;문경록;김재문
    • Proceedings of the IEEK Conference
    • /
    • 2002.06e
    • /
    • pp.165-168
    • /
    • 2002
  • This paper has been studied about the real time monitoring system development using TCP/IP ethernet and RS-422 serial communication link in general communication methods that rocket fire control agents could be monitoring about real time Rocket fire event procedures and be managing total rocket fire courses. Also, this paper has been studied the HMI(Human Machine Interface) control program and algorithm that guarantee confidential control for the Fire Display System.

  • PDF

Design of the Real-time Water Tank Wireless Control System in a Ship Using the RF and PLC (RF와 PLC를 이용한 실시간 선박용 물탱크 무선 제어 시스템 설계)

  • Park, O.D.;Lee, S.H.;Kim, H.S.;Long, Nguyen Phi;Hieu, Nguyen Hoang;Kim, H.S.;Cha, C.S.
    • Proceedings of the KIEE Conference
    • /
    • 2006.10c
    • /
    • pp.288-290
    • /
    • 2006
  • This paper presents the real-time water tank wireless control in a ship using duplex RF modules and PLC(Programmable logic Controller). The purpose of this paper is developing HMI(Human Machine Interface) for automation equipments. The system can low a cost because long wires are no more used. Analog signals of the water gauge and flow meter are changed to discrete signals by the micro-processor. The PLC checks the volume of water and runs On or Off of the valve and pump. Duplex RF modules send and receive data between the water tank and control room. Everywhere the Internet is used, operators are able to check the status of the system by the web-server.

  • PDF