• 제목/요약/키워드: Real size test

검색결과 419건 처리시간 0.028초

Development of a Real-time Monitoring Device for Measuring Particulate Matter

  • Kim, Dae Seong;Cho, Young Kuk;Yoon, Young Hun
    • 한국입자에어로졸학회지
    • /
    • 제10권1호
    • /
    • pp.1-8
    • /
    • 2014
  • In this study, we have developed a real-time monitoring device for measuring $PM_{10/2.5/1}$ of ambient aerosol particles. The real-time PM (Particulate Matter) monitor was based on the light scattering method and had 16 channels in particle size. The laboratory and field tests were carried out to evaluate the performance of the PM monitor developed. Arizona Road Dust particles ranging from diameter of 0.1 to $20{\mu}m$ were generated as test particles in the laboratory test. The field test was carried out at the Seoul Meteorological Observatory. We can obtain the particle size and number concentration (particle size distribution) only from the real-time PM monitor developed. Therefore, the average density of aerosol particles was used to obtain the PM data from the particle size distribution. The $PM_{10/2.5/1}$ results of the PM monitor were compared with the data of the Grimm Dust Monitor (Model 1.108) and a beta ray gauge (Thermo Fisher Scientific). As a result, it was shown that the $PM_{10/2.5/1}$ results obtained by the real-time PM monitor agreed well with the data of the reference devices, and overall, the real-time PM monitor could be used as a PM monitoring device for real-time monitoring of the ambient particles.

Morton씨 지간 신경종의 초음파검사상 크기와 실제 크기의 비교 (The Comparison of Ultrasonographic Size of Morton's Neuroma measured to Actual Size)

  • 김재영;이경태;양기원;손상우
    • 대한족부족관절학회지
    • /
    • 제10권1호
    • /
    • pp.80-83
    • /
    • 2006
  • Purpose: To compare ultrasonographic size of morton's neuroma measured to actual size. Materials and Methods: Thirty-two (twenty-eight patients) of symptomic Morton's neuroma were measured by ultrasonography preoperatively and by manual method that designed by authors intraoperatively from January, 2002 to May, 2003. Two results were stastically compared by paired T-test. Results: Except one, all of cases were women and the mean age of patients was 50.6 years (32-62 years). The most common associated disease was hallux valgus deformity (17 cases). Six of Morton's neuromas located on second intermetatarsal space, sixteen of them did third intemetatarsal space and ten of neuromas located simultaneously second and third intermetatarsal space. The ultrasonographic size of neuroma averaged 3.48 mm and real size was 3.99 mm. The size checked by manual method was larger than by ultrasound with statical meaning. Conclusion: The size of Morton's interdigital neuroma checked by ultrasonography on plantar aspect is smaller than real size. If you checked Morton's interdigital neuroma size by ultrasonography, you can suspect that real size of Morton's interdigital neuroma is larger than that size.

  • PDF

거시경제변수에 따른 부동산PF 연체율에 관한 연구 (A Study on the Effect of Delinquency Rate of Real Estate PF on Macroeconomic Variables)

  • 노치영;김형주
    • 한국콘텐츠학회논문지
    • /
    • 제18권4호
    • /
    • pp.416-427
    • /
    • 2018
  • 부동산PF는 대출의 상대적 규모가 커서 연체가 발생되면 시장의 파급력도 커진다. 따라서 부동산PF 연체율에 대한 관리와 거시경제적 분석이 필요하다. 선행연구에서는 주로 개별 은행의 부동산PF 데이터를 통한 미시적인 분석을 진행하여 리스트의 중요성을 평가하거나, 연체에 대한 결정요인을 분석하여 전체적인 부동산PF 규모에 의한 연구가 미흡하였다. 본 연구는 이러한 자료의 한계점을 극복하고자 거시경제변수에 따른 시장전체의 부동산PF 연체율에 대한 영향관계를 연구하였다. 본 연구는 부동산PF 대출규모, 통화량, 금리, 소비자물가지수, GDP 자료를 활용하였으며, 공적분검정 결과 적어도 2개 변수 이상에서 선형관계가 이루어짐에 따라 VECM의 1차 모형을 적용하였다. 그랜저인과관계 결과 부동산PF 연체율은 부동산PF 대출금액에 영향을 받으며, 충격반응결과 통화량, 소비자 물가지수, 금리, 대출금액, GDP 순으로 연체율에 큰 영향을 주는 것으로 나타났다. 향후 부동산PF 자금 대출 이후 금리 상승은 부동산PF 연체율에 부담을 주게 되며, 통화량의 증가는 물가의 상승을 유도하여 결국 금리상승으로 이어질 수 있어 대출규모가 클수록 위험성의 노출이 심각해 질 수 있다. 따라서 부동산PF 연체율의 관리는 대출 이후 거시적 관점에서 자금 회수에 지속적 추적과 관찰이 필요하며, 이를 통해 연체율 방지를 위한 관리방안이 필요할 것이다.

Design of Real-time Video Acquisition for Control of Unmanned Aerial Vehicle

  • Jeong, Min-Hwa
    • Journal of Positioning, Navigation, and Timing
    • /
    • 제9권2호
    • /
    • pp.131-138
    • /
    • 2020
  • In this paper, we analyze the delay phenomenon that can occur when controlling an unmanned aerial vehicle using a camera and describe a solution to solve the phenomenon. The group of pictures (GOP) value is changed in order to reduce the delay according to the frame data size that can occur in the moving image data transmission. The appropriate GOP values were determined through experimental data accumulation and validated through camera self-test, system integration laboratory (SIL) verification test and system integration test.

Sample size and statistical power consideration for diagnostic test research

  • Kim, Eu Tteum;Park, Choi Kyu;Pak, Son Il
    • 대한수의학회지
    • /
    • 제48권3호
    • /
    • pp.357-361
    • /
    • 2008
  • Although power analysis is of important tool of research, investigators in veterinary medicine are unaware of the concepts of the statistical power. Two types of error occur in classical hypothesis testing and, those errors should be avoided, if possible. Since power is highly dependent on the sample size, whenever declaring non-statistically significant result they should consider the potential for committing a Type II error in their studies, which refers to the probability of falsely stating that two treatments are equivalent despite true difference between them. Also, sample size determination is one of the most important tasks facing the researcher when planning a diagnostic study, and provides valuable information on the characteristics of a test performance. This type of analysis forms the basis for proper interpretation of test results. The aim of this article was to re-evaluate some selected studies on diagnostic test reported in the domestic veterinary publications to determine the power and necessary sample size for inequality testing to ensure the desired power. Power calculations were illustrated using real-life examples of comparison of a new test and a reference test for detecting antibodies of various animal diseases. Factors affecting to the power were also discussed.

광산란방식을 이용한 미세먼지 실시간 모니터링 장치 개발 및 성능평가 (Development and Performance Evaluation of a Real-time PM Monitor based on Optical Scattering Method)

  • 강두수;오정은;이상열;신희준;봉하경;김대성
    • 한국입자에어로졸학회지
    • /
    • 제14권4호
    • /
    • pp.107-119
    • /
    • 2018
  • In this study, we have developed a real-time monitoring device for measuring PM10 and PM2.5 of ambient aerosol particles. The real-time PM monitor (SENTRY Dust Monitor) uses the optical scattering method and has 16 channels in particle size. The laboratory and field tests were carried out to evaluate the developed SENTRY Dust Monitor. Arizona Test Dust particles were used as test particles in the laboratory test and the field test was carried out at the Jongno-gu Observatory in Seoul. The measurements of PM10 and PM2.5 concentrations obtained by SENTTRY Dust Monitor were compared with Grimm Dust Monitor (Model 1.108) and a beta ray gauge. It was shown that the PM10 and PM2.5 concentrations obtained by SENTRY Dust Monitor agree well with that of the reference devices. Based on the results obtained in this study, it could be concluded that the SENTRY Dust Monitor can be used as a PM monitoring device for real-time monitoring of the ambient aerosols.

면진된 실대형 일경간-이층 철골조 자유진동 실험 (Free Vibration Test for Base Isolated Real Size One Bay-Two Story Steel Frame)

  • 김대곤
    • 한국지진공학회:학술대회논문집
    • /
    • 한국지진공학회 2000년도 춘계 학술발표회 논문집 Proceedings of EESK Conference-Spring
    • /
    • pp.391-398
    • /
    • 2000
  • To evaluate the seismic performance of a base isolated building accurate analytical model should be selected. The analytical results such as reduced accelerations member forces and relative displacements of the superstructure of the base isolated building are only meaningful when the analytical model is close enough to the real structure. Real size one bay-two story steel frame and two kinds of seismic isolators(laminated elastomeric bearing and lead-rubber bearing) are designed. manufactured and constructed in the laboratory. Free vibration tests using fuse bars were conducted to evaluate the change of dynamic characteristics(period and damping) before and after base isolation of the steel frame. The experimental results of free vibration tests were also used as a bench mark for adjusting the selected analytical modeling to real base isolated steel frame.

  • PDF

20대 남성의 실제체형과 신체이상형(理想型)에 관한 연구 (A Study on Real Body Size and Ideal Body Shape of 18 to 25 Year-Old Men)

  • 정재은;이순원
    • 대한인간공학회지
    • /
    • 제17권2호
    • /
    • pp.49-63
    • /
    • 1998
  • The purpose of this study is to study real body size and ideal body shape by considering the degree of satisfaction of body part and understanding body size by the degree of leanness/obesity. The subjects in this study were 420 males from 18 to 25 years old. Body measurements and surveys were taken and analyzed by mean, standard variation, correlation analysis, regression analysis, crosstabulation analysis, cluster analysis, one-way ANOVA, and Duncan's Test. The results of analyses indicate that the subjects tended to be satisfied with thick chest and upper limbs, wide shoulder width, and preferred to be tall and have big hands and feet. By cluster analysis of 19 variables, the subjects were divided into 4 groups, each consisting 41, 138, 134, and 47 males. Because the 19 variables were body measurements transformed to eliminate the body size factor, this classification was considered to express how lean or how obese a human body appears. The results of one way ANOVA and Duncan's Test indicate that, according to the degree of leanness/obesity from Group I (lean tendency) to Group IV(obese tendency), characteristics of the body shape changed as follows; height became lower, limbs became shorter, trunk and limbs became thicker and weight became heavier. Also it showed that Group IV were most satisfied with chest girth, upper limb girth and shoulder width and Group I with height, hip girth and waist girth.

  • PDF

오일필터 일체형 엔진오일퇴화감지센서 시작품 개발 I (The Prototype Development of an Engine Oil Deterioration Sensor Installed Inside an Oil Filter)

  • 전상명
    • Tribology and Lubricants
    • /
    • 제24권2호
    • /
    • pp.82-89
    • /
    • 2008
  • The purpose of this study is to develop the proto type sensor installed inside an oil filter in order to detect oil deterioration level. The sensor is made up with two concentric cylinders with constant gap in between and a filter element inside the central area. The size will be designed as similar as real oil filters. The sensor will be tested on a test rig, which is circulating engine oil, with the same size of an oil filter adapting housing as real engines'. It will be measured the capacitance of a sample engine oil, then be able to be gotten the dielectric constant. The changes in the dielectric constant could be correlated with the engine oil deterioration level if the sensor development would be completed. In this paper, it will be shown the test results carrying out under variable temperature conditions at atmosphere pressure.

입도분포가 액상화 저항강도에 미치는 영향에 관한 실험적 연구 (Experimental Study on the Effect of Particle Size Distribution of Soil to the Liquefaction Resistance Strength)

  • 최문규;서경범;박성용;김수일
    • 한국지반공학회:학술대회논문집
    • /
    • 한국지반공학회 2005년도 춘계 학술발표회 논문집
    • /
    • pp.1126-1133
    • /
    • 2005
  • The effects of mean particle size and uniformity coefficient of dredged soils to the liquefaction resistance strength and dynamic characteristics are experimentally studied in this paper. Representative 4 mean particle sizes and 3 uniformity coefficients were selected and 12 representative particle size distribution curves which have different mean particle sizes and uniformity coefficients, were artificially manufactured using the real dredged river soil. Cyclic triaxial tests and torsional shear tests were carried out to analyze the effect of mean particle size and uniformity coefficient to the liquefaction resistance strength and dynamic characteristics of soils.

  • PDF