• 제목/요약/키워드: Reaction facilities

검색결과 159건 처리시간 0.03초

Reverse Transcription Polymerase Chain Reaction-based System for Simultaneous Detection of Multiple Lily-infecting Viruses

  • Kwon, Ji Yeon;Ryu, Ki Hyun;Choi, Sun Hee
    • The Plant Pathology Journal
    • /
    • 제29권3호
    • /
    • pp.338-343
    • /
    • 2013
  • A detection system based on a multiplex reverse transcription (RT) polymerase chain reaction (PCR) was developed to simultaneously identify multiple viruses in the lily plant. The most common viruses infecting lily plants are the cucumber mosaic virus (CMV), lily mottle virus (LMoV), lily symptomless virus (LSV). Leaf samples were collected at lily-cultivation facilities located in the Kangwon province of Korea and used to evaluate the detection system. Simplex and multiplex RT-PCR were performed using virus-specific primers to detect single- or mixed viral infections in lily plants. Our results demonstrate the selective detection of 3 different viruses (CMV, LMoV and LSV) by using specific primers as well as the potential of simultaneously detecting 2 or 3 different viruses in lily plants with mixed infections. Three sets of primers for each target virus, and one set of internal control primers were used to evaluate the detection system for efficiency, reliability, and reproducibility.

A Study on the Corrosion Inhibition Effects of Sodium Heptanoate for Carbon Steel in Aqueous Solution

  • Won, D.S.;Kho, Y.T.
    • Corrosion Science and Technology
    • /
    • 제3권6호
    • /
    • pp.227-232
    • /
    • 2004
  • The carboxylates as a corrosion inhibitor has been studied by many researchers because of its environmental safety and low depletion rate. However, conventional test methods of inhibitor such as weight loss measurements, linear polarization resistance and corrosion potential monitoring etc., evaluate uniform corrosion of metals. These methods are unable to evaluate crevice-related corrosions, which are encountered in most of heat exchanging facilities. In order to choose the optimum corrosion inhibitor, the appropriate test methods are required to evaluate their performances in service environment. From this point of view, polarization technique was used to evaluate the characteristics of sodium heptanoate on corrosion behavior for carbon steel. Especially a thin film crevice sensor technique were applied to simulate the crevice corrosion in this study. From these experiments, we found that oxygen as an oxidizing agent was required to obtain stable passive film on the metal. Presence of oxygen, however, accelerated crevice corrosion. Potential shift by oxygen depletion and weakened inhibitive film inside the crevice were responsible for such accelerated feature. It is shown that film for corrosion inhibition is a mixture of sodium heptanoate and iron (II) heptanoate as reaction product of iron surface and sodium heptanoate. The iron (II) heptanoate which has been synthesized by reaction of heptanoic acid and ferrous chloride in methanol solution forms bidentate complex.

황토와 석회의 혼합처리에 의한 정수 슬러지의 개질화에 관한 연구 (Loess and Lime Treatment for Modification of Waterworks Sludges)

  • 임성진;조재준;이재복
    • 상하수도학회지
    • /
    • 제14권4호
    • /
    • pp.318-327
    • /
    • 2000
  • Sludge production from water treatment plants is increasing each year because water resources deterioration is proceeding and water supply facilities are growing due to water demand increase. Water treatment plant sludges can be modified to soil cover in sanitary landfilling site through the lime treatment and other alternatives. The compression strength of $1.0kg/cm^2$ is necessary for the dozer operation on soft son cover material at municipal landfilling site. Modified sludge was experimentally produced in this study with lime, bentonite, loess, and activated loess dosing. X-ray diffraction patterns of the limed water treatment plant sludge confirmed the presence of calcium carbonate and ettringite. Unconfined compression strength properties of modified sludges showed material property improvement applicable for soil cover alternatives. When adding 20-30% activated loess to water treatment plant sludges. the modified sludges could reach the compression strength for cover soil after 7 days solidification reaction, but decrease of compression strength was intentioned in 28 days reaction period. Solidification effect of the modified sludge with activated loess was observed through the scanning electron microscope.

  • PDF

High-valence Mo doping for promoted water splitting of Ni layered double hydroxide microcrystals

  • Kyoungwon Cho;Seungwon Jeong;Je Hong Park;Si Beom Yu;Byeong Jun Kim;Jeong Ho Ryu
    • 한국결정성장학회지
    • /
    • 제33권2호
    • /
    • pp.78-82
    • /
    • 2023
  • The oxygen evolution reaction (OER) is the primary challenge in renewable energy storage technologies, specifically electrochemical water splitting for hydrogen generation. We report effects of Mo doping into Ni layered double hydroxide (Ni-LDH) microcrystal on electrocatalytic activities. In this study, Mo doped Ni-LDH were grown on three-dimensional porous nicekl foam (NF) by a facile solvothermal method. Homogeneous LDH structure on the NF was clearly observed. However, the surface microstructure of the nickel foam began to be irregular and collapsed when Mo precursor is doped. Electrocatalytic OER properties were analyzed by Linear sweep voltammetry (LSV) and Electrochemical impedance spectroscopy (EIS). The amount of Mo doping used in the electrocatalytic reaction was found to play a crucial role in improving catalytic activity. The optimum Mo amount introduced into the Ni LDH was discussed with respect to their OER performance.

중소규모 화학업종을 위한 자율점검표 개발 연구 (A Study on the Development of Self-Checklists for Small and Medium-Sized Chemical Industries)

  • 심우섭;오경석
    • 한국산업융합학회 논문집
    • /
    • 제26권5호
    • /
    • pp.757-763
    • /
    • 2023
  • Major industrial accidents in which workers die due to fires or explosions while working at chemical substance handling workplaces continue to occur. Among the major industrial accidents that occurred between 2005 and 2021, the accident status by work situation and equipment was analyzed. Through analysis, it was confirmed that storage, reaction, and piping facilities were the main causes of the accident, and a self-checklist for each facility was developed. Verification was conducted through the supply and use groups to evaluate the suitability of the use, duties, and items of the self-checklist. The user group showed higher satisfaction than the supplier group for all three suitability of use, job, and item. In particular, since the inspection items of the self-checklist were organized around the cause of the accident derived through the analysis of actual accident cases, the satisfaction level was high in all groups. It is expected that the self-checklist developed through this study will be useful not only for large companies but also for small and medium-sized chemical industries that lack professional manpower.

금속 표면 제염을 위한 코발트의 플라즈마 식각 반응 연구 (A Study on Plasma Etching Reaction of Cobalt for Metallic Surface Decontamination)

  • 전상환;김용수
    • 방사성폐기물학회지
    • /
    • 제6권1호
    • /
    • pp.17-23
    • /
    • 2008
  • 이 연구에서는 플라즈마 제염 기술의 실용화를 위해 $CF_4/O_2$, $SF_6/O_2$, $NF_3$ 등의 반응성 플라즈마 기체를 이용하여 원자력 시설의 주요 오염원인 코발트 핵종에 대한 표면 제염 모의실험을 수행하였다. 디스크 형태의 금속코발트에 대하여 시편 표면 온도를 변수로 플라즈마 식각 실험을 수행한 결과 반응율은 $420^{\circ}C$에서 $NF_3$ 기체의 경우 $17.2\;{\mu}m/min.$ 그리고 $SF_6$$CF_6/O_2$ 기체의 경우 각각 $2.56\;{\mu}m/min.$$1.14\;{\mu}m/min.$이었으며, 이들 반응의 활성화에너지는 각각 39.4 kJ/mol, 42.1 kJ/mol, 116.0 kJ/mol이었다. 이와 함께 AES (Auger Electron Spectroscopy)를 이용하여 반응 생성물 성분 분석 결과 이들 반응의 주요 반응 기구는 코발트의 불화 반응임이 밝혀졌다. 이 연구를 통해 확보된 $17\;{\mu}m/min.$의 금속 표면 식각율은 주요 반도체 공정의 식각율을 뛰어넘는 높은 식각율로 플라즈마 제 염 기술의 실용화를 앞당길 수 있는 고무적인 결과라 할 수 있을 것이다.

  • PDF

순산소연소 조건에서 Drop tube furnace를 이용한 운전변수에 따른 석회석의 탈황특성 연구 (Study on the Desulfurization Characteristic of Limestone Depending on the Operating Parameters of In-Furnace Desulfurization for Oxy-Fuel Combustion Using Drop Tube Furnace)

  • 최욱;조항대;최원길;박영성;길상인;이형근
    • Korean Chemical Engineering Research
    • /
    • 제49권6호
    • /
    • pp.857-864
    • /
    • 2011
  • 순산소연소는 높은 연소 효율과 적은 배가스량, 낮은 질소산화물 농도를 장점으로 하고 있으며 연소온도 조절을 위한 배가스 재순환에 의해 배출되는 연소가스중의 $CO_2$ 농도를 95%까지 농축이 가능하므로 석탄 연소설비에 대한 유망한 CCS 기술로 부각되고 있다. 본 연구는 순산소연소 조건에서 배가스의 재순환을 통한 $CO_2$ 농도 증가에 기인하는 직접 황화반응이 탈황효율에 미치는 영향을 평가하고 반응온도, $CO_2$ 농도, $SO_2$ 농도상승이 $SO_2$ 제거효율에 미치는 영향과 배가스 중 수분 등이 $SO_2$ 제거효율에 미치는 영향을 실험적으로 고찰하였다. 반응온도 $1,200^{\circ}C$까지 온도 상승에 따라 $SO_2$의 제거효율은 증가하였고 Ca/S비, $CO_2$ 농도와 수분이 증가할수록 $SO_2$ 제거효율이 증가하였다. 이러한 운전변수는 영향인자 평가를 통하여 Ca/S 비>체류시간>$O_2$농도>반응온도>$SO_2$농도>$CO_2$농도>수분농도의 순으로 탈황반응에 영향을 미치는 것으로 나타났다. 또한 운전변수별 실험결과를 이용하여 로내 건식탈황에 있어서 각 운전변수별 성능 영향인자를 평가할 수 있는 반경험적 모델식을 도출하였다.

합성 윤활유 및 고압 작동유 누출감지 필름형 센서의 구현 (Implementation of Film Type Sensor for Synthetic Lube Oil and High Pressure Hydraulic Fluid Leak Detection)

  • 박노진;유동근;유홍근
    • 센서학회지
    • /
    • 제23권4호
    • /
    • pp.266-271
    • /
    • 2014
  • Chemical sensors are used in various industrial facilities such high-risk and prevent the leakage of substances, important in life and environmental protection and the safe use of industry, used for management. In particular, high-temperature environments such as power generation equipment of the rotating part due to leakage generated by the various oil, power plants Shut Down, fire, work environment (exposure to various chemical solution and gas leak) and various water, air and soil pollution causes. Thus, over the long term through various channels such as crops and groundwater contamination caused by the slow, serious adverse effect on the ecosystem. In this paper, synthetic lube oil and high pressure hydraulic fluid leakage and immediately detect a new Printed Electronic implementation of technology-based film-type sensors, and its performance test. Thus, industrial accidents and environmental pollution and for early detection of problems, large accidents can be prevented. Experimental results of the synthetic lube oil and high pressure hydraulic fluid solution after the contact time depending on the experiment and the oil solution of the sensor material of the conductive porous PE resistance value by a chemical reaction could be confirmed that rapid increase. Also implemented in the film-type oil sensor electrical resistance change over time of the reaction rate and the synthetic lube oil is about 2 minutes or less, the high pressure hydraulic fluid is less than about 1 minute was. Therefore, more high-pressure hydraulic fluid such as a low volatility synthetic lube oils are the resistance change and the reaction rate was confirmed to be the slowest.

석유 코크스의 에너지 전환 : CO2 가스화 (Energy conversion of petroleum coke : CO2 gasification)

  • 국진우;곽인섭;이시훈
    • 한국연소학회:학술대회논문집
    • /
    • 한국연소학회 2014년도 제49회 KOSCO SYMPOSIUM 초록집
    • /
    • pp.255-257
    • /
    • 2014
  • The installation of light oil facilities or delayed cokers seems to be inevitable in the oil refinery industry due to the heavy crude oil reserves and the increased use of light fuels as petroleum products. Petroleum coke is a byproduct of oil refineries and it has higher fixed carbon content, higher calorific value, and lower ash content than coal. However, its sulfur content and heavy metal content are higher than coal. In spite of disadvantages, petroleum coke might be one of promising resources due to gasification processes. The gasification of petroleum coke can improve economic value of oil refinery industries by handling cheap, toxic wastes in an environment-friendly way. In this study, $CO_2$ gasification reaction kinetics of petroleum coke, various coals and mixing coal with petroleum coke have investigated and been compared by using TGA. The kinetics of $CO_2$ gasification has been performed with petroleum coke, 3 kinds of bituminous coal [BENGALLA, White Haven, TALDINSKY], and 3 kinds of sub-bituminous coal [KPU, LG, MSJ] at various temperature[$1100-1400^{\circ}C$].

  • PDF

단자이완 검출기술의 개발 (Development of Technique to Detect a Loose Terminal)

  • 임용배;전정채;박찬엄;배석명;주남규
    • 한국산학기술학회:학술대회논문집
    • /
    • 한국산학기술학회 2009년도 추계학술발표논문집
    • /
    • pp.854-859
    • /
    • 2009
  • Multiple people using places are being managed to prevent disasters by the special law for safety supervising of multiple people using spots. The KESCO is managing the places through intensification of inspection. Perfect safety is not insured by frequencyinspections because disaster symptoms in electrical facilities include invisible faults. Especially, entertainment spots, such as entertainment bars and karaoke bars, are different from other multiple people using places, and active reaction to prevent electrical fires is impossible. Therefore, special protection plans to prevent electrical disasters are needed. In this paper, equipments of entertainment spots were researched, and their electrical characteristics were analyzed. The function for detecting aloose terminal, which is one of the main causes of electrical fires, was developed.

  • PDF