• Title/Summary/Keyword: Ray Method

Search Result 5,500, Processing Time 0.032 seconds

AN EVALUATION OF THE PRIMARY IMPLANT STABILITY AND THE IMMEDIATE LOAD-BEARING CAPACITY ACCORDING TO THE CHANGE OF CORTICAL BONE THICKNESS (치밀골 두께 변화에 따른 임플랜트 1차안정성과 즉시하중부담능 평가)

  • Yi Yang-Jin;Park Chan-Jin;Cho Lee-Ra
    • The Journal of Korean Academy of Prosthodontics
    • /
    • v.43 no.2
    • /
    • pp.248-257
    • /
    • 2005
  • Statement of problem. Cortical bone plays an important role in the primary implant stability, which is essential to immediate/early loading. However, immediate load-bearing capacity and primary implant stability according to the change of the cortical bone thickness have not been reported. Purpose. The objectives of this study were (1) to measure the immediate load-bearing capacity of implant and primary implant stability according to the change of cortical bone thickness, and (2) to evaluate the correlation between them. Material and methods.48, screw-shaped implants (3.75 mm$\times$7 mm) were placed into bovine rib bone blocks with different upper cortical bone thickness (0-2.5 mm) and resonance frequency (RF) values were measured subsequently. After fastening of healing abutment. implants were subjected to a compressive load until tolerated micromotion threshold known for the osseointegration and load values at threshold were recorded. Thereafter, RF measurement after loading, CT taking and image analysis were performed serially to evaluate the cortical bone quality and quantity. Immediate load-bearing capacity and RF values were analyzed statistically with ANOVA and post-hoc method at 95% confidence level (P<0.05). Regression analysis and correlation test were also performed. Results. Existence and increase of cortical bone thickness increased the immediate load-bearing capacity and RF value (P<0.05) With the result of regression analysis, all parameter's of cortical bone thickness to immediate load-bearing capacity and resonance frequency showed significant positive values (P<0.0001). A significant high correlation was observed between the cortical bone thickness and immediate load-beating capacity (r=0.706, P<0.0001), between the cortical bone thickness and resonance frequency (r=0.753, P<0.0001) and between the immediate load-bearing capacity and resonance frequency (r=0.755, P<0.0001). Conclusion. In summary, cortical bone thickness change affected the immediate load-baring capacity and the RF value. Although RF analysis (RFA) is based on the measurement of implant/bone interfacial stiffness, when the implant is inserted stably, RFA is also considered to reflect implant/bone interfacial strength of immediately after placement from high correlation with the immediate load-baring capacity. RFA and measuring the cortical bone thickness with X-ray before and during surgery could be an effective diagnosis tool for the success of immediate loading of implant.

Comparative study on the physicochemical properties and cytocompatibility of microporous biphasic calcium phosphate ceramics as a bone graft substitute (미세다공성 Biphasic calcium phosphate ceramics의 골이식 대체재로서의 기본특성에 대한 비교연구)

  • Park, Kwang-Bum;Park, Jin-Woo;Ahn, Hyun-Uk;Yang, Dong-Jun;Choi, Seok-Kyu;Jang, II-Sung;Yeo, Shin-Il;Suh, Jo-Young
    • Journal of Periodontal and Implant Science
    • /
    • v.36 no.4
    • /
    • pp.797-808
    • /
    • 2006
  • Objective : The purpose of this study was to evaluate the physicochemical properties and cytocompatibility of microporous, spherical biphasic calcium phosphate(BCP) ceramics with a 60/40 $hydroxyapatite/{\beta}$ -tricalcium phosphate weight ratio for application as a bone graft substitute. Materials and Methods : Microporous, spherical BCP granules(MGSB) were prepared and their basic characteristics were compared with commercially available BCP(MBCP; Biomatlante, France) and deproteinized bovine bone mineral(Bio-Oss; GBistlich-Pharma, Switzerland, BBP; Oscotec. Korea), Their physicochemical properties were evaluated by scanning electron microscopy, X-ray diffractometry, Fourier-transform infrared spectroscopy, inductively coupled plasma atomic emission spectrometer, and Brunauer-Emmett-Teller method. Cell viability and proliferation of MC3T3-El cells on different graft materials were evaluated. Results : MGSB granules showed a chemical composition and crystallinity similar with those in MBCP, they showed surface structure characteristic of three dimensionally, well-interconnected micropores. The results of MTT assay showed increases in cell viablity with increasing incubation times. At 4d of incubation, MGSB, MBCP and BBP showed similar values in optical density, but Bio-Oss exhibited significantly lower optical density compared to other bone substitutes(p <0,05). MGSB showed significantly greater cell number compared to other bone substitutes at 3, 5, and 7d of incubation(p <0,05), which were similar with those in polystyrene culture plates. Conclusion: These results indicated the suitable physicochemical properties of MGSB granules for application as an effective bone graft substitute. which provided compatible environment for osteoblast cell growth. However, further detailed studies are needed to confirm its biological effects on bone formation in vivo.

Rapid Screening of Naturally Occurring Radioactive Nuclides (238U, 232Th) in Raw Materials and By-Products Samples Using XRF

  • Park, Ji-Young;Lim, Jong-Myoung;Ji, Young-Yong;Lim, Chung-Sup;Jang, Byung-Uck;Chung, Kun Ho;Lee, Wanno;Kang, Mun-Ja
    • Journal of Radiation Protection and Research
    • /
    • v.41 no.4
    • /
    • pp.359-367
    • /
    • 2016
  • Background: As new legislation has come into force implementing radiation safety management for the use of naturally occurring radioactive materials (NORM), it is necessary to establish a rapid and accurate measurement technique. Measurement of $^{238}U$ and $^{232}Th$ using conventional methods encounter the most significant difficulties for pretreatment (e.g., purification, speciation, and dilution/enrichment) or require time-consuming processes. Therefore, in this study, the applicability of ED-XRF as a non-destructive and rapid screening method was validated for raw materials and by-product samples. Materials and Methods: A series of experiments was conducted to test the applicability for rapid screening of XRF measurement to determine activity of $^{238}U$ and $^{232}Th$ based on certified reference materials (e.g., soil, rock, phosphorus rock, bauxite, zircon, and coal ash) and NORM samples commercially used in Korea. Statistical methods were used to compare the analytical results of ED-XRF to those of certified values of certified reference materials (CRM) and inductively coupled plasma mass spectrometry (ICP-MS). Results and Discussion: Results of the XRF measurement for $^{238}U$ and $^{232}Th$ showed under 20% relative error and standard deviation. The results of the U-test were statistically significant except for the case of U in coal fly ash samples. In addition, analytical results of $^{238}U$ and $^{232}Th$ in the raw material and by-product samples using XRF and the analytical results of those using ICP-MS ($R^2{\geq}0.95$) were consistent with each other. Thus, the analytical results rapidly derived using ED-XRF were fairly reliable. Conclusion: Based on the validation results, it can be concluded that the ED-XRF analysis may be applied to rapid screening of radioactivities ($^{238}U$ and $^{232}Th$) in NORM samples.

Hot Corrosion Behavior of Plasma Sprayed 4 mol% Y2O3-ZrO2 Thermal Barrier Coatings with Volcanic Ash (플라즈마 용사법으로 제작된 4mol% Y2O3-ZrO2 열차폐코팅의 화산재에 의한 고온열화거동)

  • Lee, Won-Jun;Jang, Byung-Koog;Lim, Dae-Soon;Oh, Yoon-Suk;Kim, Seong-Won;Kim, Hyung-Tae;Araki, Hiroshi;Murakami, Hideyuki;Kuroda, Seiji
    • Journal of the Korean Ceramic Society
    • /
    • v.50 no.6
    • /
    • pp.353-358
    • /
    • 2013
  • The hot corrosion behavior of plasma sprayed 4 mol% $Y_2O_3-ZrO_2$ (YSZ) thermal barrier coatings (TBCs) with volcanic ash is investigated. Volcanic ash that deposited on the TBCs in gas-turbine engines can attack the surface of TBCs itself as a form of corrosive melt. YSZ coating specimens with a thickness of 430-440 ${\mu}m$ are prepared using a plasma spray method. These specimens are subjected to hot corrosion environment at $1200^{\circ}C$ with five different duration time, from 10 mins to 100 h in the presence of corrosive melt from volcanic ash. The microstructure, composition, and phase analysis are performed using Field emission scanning electron microscopy, including Energy dispersive spectroscopy and X-ray diffraction. After the heat treatment, hematite ($Fe_2O_3-TiO_2$) and monoclinic YSZ phases are found in TBCs. Furthermore the interface area between the molten volcanic ash layers and YSZ coatings becomes porous with increases in the heat treatment time as the YSZ coatings dissolved into molten volcanic ash. The maximum thickness of this a porous reaction zone is 25 ${\mu}m$ after 100 h of heat treatment.

THE TOPICAL ANESTHESIA WITH EMLA CREAM IN CHILDREN : A CASE REPORT (소아에서 EMLA cream을 이용한 도포마취 : 증례보고)

  • Kim, He-Jin;Ko, Sung-Back;Hong, Seong-Soo;Lee, Chang-Seop;Lee, Sang-Ho
    • Journal of the korean academy of Pediatric Dentistry
    • /
    • v.29 no.1
    • /
    • pp.69-75
    • /
    • 2002
  • A number of techniques may be employed to reduce the discomfort of syringe or needle for dental care. The use of topical anesthesia is one such method. Topical anesthetics are applied to alleviate pain during many clinical procedures, such as injection of local infiltration anesthetics, primary tooth extraction, X-ray taking of sensitive patients, reducing gag reflex prior to impression taking. In children, placement of a rubber dam clamp, however, may cause significant discomfort for purpose of pit and fissure sealant and preventive resin restoration(PRR). A topical anesthetic would be beneficial to aid in rubber dam placement for this purpose. It has been suggested that all intra-oral topical anesthetics are equally effective on reflected mucosa, however EMLA(an acronym for eutectic mixture of local anesthetics), which was developed in the 1980s and produces surface anesthesia of skin, has been shown to be more effective than conventional topical anesthetics when used on attached gingivae. This report is topical anesthesized 4 case by EMLA cream, who showed better effect in reducing the pain of infiltration anesthesia, extraction of deciduous teeth, rubber dam clamp placement and reducing the pain of preformed crown adaptation.

  • PDF

Evaluation of Hydrogen Properties on Mg2NiHx-Graphene Composites by Mechanical Alloying (기계적 합금화법으로 제조한 Mg2NiHx-Graphene 복합재료의 수소화 특성 평가)

  • Lee, Young-Sang;Lee, Soo-Sun;Lee, Byung-Ha;Jung, Seok;Hong, Tae-Whan
    • Transactions of the Korean hydrogen and new energy society
    • /
    • v.25 no.1
    • /
    • pp.19-27
    • /
    • 2014
  • Mg hydride has a high hydrogen capacity (7.6%), at high temperature, and is a lightweight and low cost material, thus it a promising hydrogen storage material. However, its high operation temperature and very slow reaction kinetics are obstacles to practical application. In order to overcome these disadvantages of Mg hydride, graphene powder was added to it. The addition of graphene has been shown to reduce the operating temperature of dehydrogenation. Moreover, in this report the environmental aspects of $MgH_x$-Graphene composites are investigated by means of the environmental life cycle assessment (LCA) method. $MgH_x$-Graphene mixture was prepared by hydrogen induced mechanical alloy (HIMA). The synthesized powder was characterized by XRD(X-ray Diffraction). The hydrogenation behaviors were evaluated by using a Sievert's type automatic PCT apparatus. Such evaluation of Materials also conducted in the LCA. From the result of P-C-T(Pressure-Composition-Temperature) curves, the $MgH_x$-3wt.% graphene composite was evaluated as having a 5.86wt.% maximum hydrogen storage capacity, at 523K. From absorption kinetic testing, the $MgH_x$-7wt.% graphene composite was evaluated as having a maximum 6.94wt.%/ms hydrogen absorption rate, at 573K. Environment evaluation results for the $MgH_x$-graphene composites and other materials indicated environmental impact from the electric power used and from the materials themselves.

Effect of $BaTiO_3$ according to $(Bi_{0.5}Na_{0.5})TiO_3$ for Pb-free PTC (Pb-free PTC에 있어서 $(Bi_{0.5}Na_{0.5})TiO_3$ 첨가에 따른 $BaTiO_3$ 효과)

  • Lee, Mi-Jai;Paik, Jong-Hoo;Kim, Sei-Ki;Kim, Bip-Nam;Lee, Woo-Yong
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2008.06a
    • /
    • pp.57-58
    • /
    • 2008
  • PTC thermistor are characterized by an increase in the electrical resistance with temperature. The PTC materials of middle Curie point were produced or that of high Curie point (above $200^{\circ}C$), it was determined that compositional modifications of $Pb^{2+}$ for $Ba^{2+}$ produce change sin the Curie point to higher temperature. PTC ceramic materials with the Curie point above $120^{\circ}C$ were prepared by adding $PbTiO_3$, PbO or $Pb_3O_4$ into $BaTiO_3$. Thereby, adding $Pb^{2+}$ into $BaTiO_3$-based PTC material to improve Tc was studied broadly, however, weal know that PbO was poisonous and prone to volatilize, then to pollute the circumstance and hurt to people, so we should dope other innocuous additives instead of lead to increase Tc of composite PTC material. In order to prepare lead-free $BaTiO_3$-based PTC with middle Curie point, the incorporation on $Bi_{1/2}Na_{1/2}TiO_3$ into $BaTiO_3$-based ceramics was investigated on samples containing 0, 1, 2, 3, 4, and 50mol% of $Bi_{1/2}Na_{1/2}TiO_3$. $Bi_{1/2}Na_{1/2}TiO_3$ was compounded as standby material by conventional solid-state reaction technique. The starting materials were $Bi_{1/2}Na_{1/2}TiO_3$, $BaCO_3$, $TiO_2$ and $Y_2O_3$ powder, and using solid-state reaction method, too. The microstructures of samples were investigated by SEM, DSC, XRD and dielectric properties. Phase composition and lattice parameters were investigated by X-ray diffraction.

  • PDF

Property Analysis of Ceramic Interconnect Prepared by Thermal Plasma Spray Coating Method for SOFC (Thermal Plasma Spray Coating 법에 의해 코팅된 SOFC용 세라믹 연결재 특성 분석)

  • Park, Kwang-Yeon;Pi, Seuk-Hoon;Lee, Jong-Won;Lee, Seung-Bok;Lim, Tak-Hyoung;Park, Seok-Joo;Song, Rak-Hyun;Shin, Dong-Ryul
    • Korean Chemical Engineering Research
    • /
    • v.49 no.6
    • /
    • pp.710-714
    • /
    • 2011
  • In present work, $La_{0.8}Ca_{0.2}CrO_{3}$(LCC), $La_{0.8}Sr_{0.2}CrO_{3}$(LSC) and $La_{0.8}Ca_{0.2}CrO_{0.9}Co_{0.1}O_{3}$(LCCC) ceramic interconnect layer for SOFC were prepared by using thermal plasma spray coating process. The LCC, LSC and LCCC powders were characterized by x-ray diffraction(XRD), scanning electron microscopy(SEM), particle counter and BET analysis. In addition, basic and essential properties such as the surface morphology, cross section, gas leak rate, and electrical conductivity of LCC, LSC, and LCCC layers coated by thermal plasma spray coating process were analyzed and discussed. Based on these experimental results, it can be concluded that the LCCC layer coated by thermal plasma spray coating process can be suitable as a ceramic interconnect of SOFC.

Crystal Structure of a Bromine Sorption Complex of Dehydrated Calcium and silver Exchanged Zeolite A (칼슘 및 은 이온으로 치환된 제올라이트 A를 탈수한 후 브롬을 흡착한 결정구조)

  • Bae, Myung-Nam;Kim, Un-Sik;Kim, Yang
    • Korean Journal of Crystallography
    • /
    • v.8 no.2
    • /
    • pp.127-131
    • /
    • 1997
  • The crystal structure of a bromine sorption complex of vacuum-dehydrated Ag+ and Ca2+ exchanged zeolite A(a=12,234(1) Å) has been determined by single-crystal X-ray diffraction methods in the cubic space group Pm3m. The crystal was prepared by flow method using exchange solution in which mole ratio of AgNo3 and Ca(NO3)2 was 1:150 with a total concentration of 0.05M. The crystal was dehydrated at 360℃ and 2 ×10-6 Torr for 2days, followed by exposure to 180 Torr of Br2 vapor for 20min. full-matrix least-squares refinements converged to the final error indices of R1=0.111 and R2=0.101 using 90 reflections for which I>3o(I). About 3.1 Ag+ ions and 4.45 Ca2+ ions lie on the two crystallographically nonequivalent three-fold axes associated with 6-ring oxygens. A total of six bromine molecules are sorbed per unit cell. Each bromine molecule approaches a framework oxide ions axially (Br-Br-O=171(2)', O-Br=3.25(6) Å; and Br-Br=2,61(8) Å by a charge-transfer interaction.

  • PDF

Color therapy and application of color to oriental medical science (색채치료(色彩治療)와 한의학(漢醫學)에서의 색(色)의 적용(適用))

  • Park, Seung Lim;Kang, Jung Soo
    • Journal of Haehwa Medicine
    • /
    • v.12 no.1
    • /
    • pp.79-102
    • /
    • 2003
  • It has been believed that the human body can be effected by color, sound, smell, and taste - each of them is based on the original character. Out of these elements, the color can be a mediation that absorbs energy into human body and adapts it to the creatures whose life are definitely based on the solar energy. This thesis makes a study of the possibility of applying the color to the oriental medical science by researching the color psychology and therapy which are studied in the west medical science, the recognition and application of color developed from orientalism, and the opinion of color in the oriental medical science. Color therapy is one of the psychological treatment techniques that are able to recover and maintain the health with the rays of the sun rays and the color. The light and the color have its energy that may relax, harmonize, encourage, or excite a human being. This is because the wavelength and the vibration of each color will take effects to human body. The core energy of absorbing and distributing the color vibration is made in the 7 "chakras" in the body, which are the pith and marrow of bio-energy directly connected with the center of the nervous system. There are several methods in the color therapy - the treatment of solar ray, the color-bath, the water-therapy using color energy, the inducement of the solar energy into the body, the acupuncture, the therapy of crystal and jewel, and the self-suggestion dependent upon the color. The color therapy can help us to keep our balance by changing the emotion into the positive energy that will cure the disease with color. As a result, this method not only must be useful to cure physical disease, or develop into good health but also will be used in conforming itself to the mental disease. The color therapy mainly uses the eight colors, which are made by mixing Red, Yellow and Blue basic colors in the field. They are never used in the treatment, but they will go along with complementary colors. This rule is closely connected with the theory of yin and yang which lies at the root of oriental philosophy, and with the treatment principle of oriental medical science whose field is focused on the balancing the body mentally as well as physically. In the East, it is the Obangsaek - the color of blue, red, yellow, white, and black in the theory of yin and yang and the five elements that have been used in helping people having trouble with their health for a long time. In the view of the oriental medical science, these five colors attached the theory of five-elements have been very useful to the physiology, the pathology, or the diagnosis, and been applied to the medical treatment, combining themselves with a five-taste in medicinal herbs. Since the study of color and human physiology has been made in some different interest and fields these days, it goes to prove that the different function of color we couldn't have got before becomes very useful to the medical science. The color must be worth researching the diversity for applying itself to the oriental medical science.

  • PDF