• Title/Summary/Keyword: Ray Method

Search Result 5,500, Processing Time 0.033 seconds

Fabrication of a Micro-Structure by Modified DXRL Process (수정된 DXRL 공정에 의한 미세구조 제작)

  • Han, Sang-Pil;Jeong, Myung-Yung;Jung, Suk-Won;Kim, Jin-Tae
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • v.27 no.9
    • /
    • pp.1517-1523
    • /
    • 2003
  • Deep X-ray lithography (DXRL), a fabrication method for the production of microstructures with a high aspect ratio, plays an important role in the subsequent electroplanting process. However, secondary radiation is generated during X-ray exposure and damages the resist adhesion to the metal layer. To solve adhesion problems, we modified the conventional DXRL process, changing the sequence of polymer adhesion in DXRL process. With optimized X-ray exposure and development conditions based on a calculated and modified X-ray power spectrum, we fabricated various polymer microstructures and achieved a maximum aspect ratio of 40.

Analysis of Continuum X-ray Specturum and Determination of Electron Temperature from Iodine Photodissociation Laser produced plasma (집속된 광분해 옥소레이저에 의한 플라즈마로부터 방출되는 연속 X-선 스펙트럼 분석과 전자온도 결정)

  • 김동환;김남성;이상수
    • Proceedings of the Optical Society of Korea Conference
    • /
    • 1988.06a
    • /
    • pp.135-144
    • /
    • 1988
  • 1-GW Iodine photodissociation Laser (λ=1.315${\mu}{\textrm}{m}$)is focused to generate the continuum x-ray radiation at titanium(z=22)target. A piced of aluminum(360 )-mylar(8${\mu}{\textrm}{m}$) film is used to isolate the soft X-ray radiation emitted. Convex-xurved mica crystal spectrometer is used to obtain the soft x-ray spectra from the laser titanium target plasma and the slope of continum X-ray spectra are found to show two different different electron effective temperaturres, 0.11keV and 7.1KeV. We compare the two temperature result with the foil absorption method.

  • PDF

Region-wise evaluation of gamma-ray exposure dose in decontamination operation after a nuclear accident

  • Jeong, Hae Sun;Hwang, Won Tae;Han, Moon Hee;Kim, Eun Han;Lee, Jo Eun;Lee, Cheol Woo
    • Nuclear Engineering and Technology
    • /
    • v.53 no.8
    • /
    • pp.2652-2660
    • /
    • 2021
  • The gamma-ray exposure doses in decontamination operation after a nuclear accident were evaluated with a consideration of various geometrical conditions and specific gamma-ray energies. The calculation domain is organized with three residence types and each form is divided into two kinds of geometrical arrangements. The position-wise air KERMA values were calculated with an assumption of evenly distributed gamma-ray source based on Monte Carlo radiation transport analysis using the MCNP code. The radioactivity is initially set to be unity to be multiplied by the deposition value measured in the actual accident condition. The workforce data set depending on the target object was determined by modifying the Fukushima report. The external exposure doses for decontamination workers were derived from the calculated KERMA values and the workforce analysis. These results can be used to efficiently determine the workforce required by the characteristics of the area and the structure to be decontaminated within the dose limits.

X-RAY Inspection for PCB/SMT & Electronics Components Latest Development

  • Maur Friendhelm W.
    • Proceedings of the International Microelectronics And Packaging Society Conference
    • /
    • 2004.02a
    • /
    • pp.17-25
    • /
    • 2004
  • During the past few years, advances have been made in both in X-ray tube and detector technologies. The field of microfocus radioscopy has been established as an important testing process and has expanded into many new industrial applications that require quality control or process optimization. The first nanofocus and multifocus X-ray systems have become available with a focal spot of .5 micron. In the existing range of microfocus X-ray tubes, further improvements have been achieved as well, such as increased long term stability of intensity position constancy. Software, image processing and manipulation techniques have all progressed as well, allowing X-ray to become a formidable non-destructive inspection method for manufacturers in virtually every industry, especially those involved with Electronic Packaging and SMT.

  • PDF

Sharpness Enhancement of Tooth X-ray Images Through Elimination of Complicated Background (복잡한 배경 제거를 통한 치아 X-ray 영상의 선예도 개선)

  • Kun-Woo Na;Keun-Ho Rew
    • Journal of Information Technology Applications and Management
    • /
    • v.30 no.1
    • /
    • pp.11-19
    • /
    • 2023
  • To remove unnecessary background from tooth X-ray images and enhance the sharpness of tooth and gum images, image processing techniques including contrast adjustment and histogram equalization are used. The introduction of two methods for detecting the boundary of the tooth and gum region and separating the tooth and gum from the background. In both cases, the background of the tooth X-ray images could be removed as a result, improving the quality of the images. The proposed method improves MTF (Modulation Transfer Function), an image performance indicator, as a result of measuring MTF. The original image's spatial frequency ranged from 4.73 to 11.40 lp/mm at the 10% response, whereas the proposed image's spatial frequency ranged from 10.90 to 11.85 lp/mm, giving uniformly enhanced results. In contrast, tooth and gums could not be completely separated from the background using Apple's Lift subject from background function.

High Pressure X-Ray Diffraction Study on a Goethite using Synchrotron Radiation (방사광을 이용한 괴타이트에 대한 고압 X-선 회절연구)

  • 김영호;이지은
    • Journal of the Mineralogical Society of Korea
    • /
    • v.10 no.2
    • /
    • pp.75-81
    • /
    • 1997
  • High pressure X-ray diffraction study was carried out on a natural FeO(OH)-goethite to investigate its compressibility at room temperature. Energy dispersive X-ray diffraction method was employed using Mao-Bell type diamond anvil cell with Synchrotron Radiation. MgO powder was compressed together with goethite for the high pressure determinations. Bulk modullus was determined to be 147.9 GPa by the Birch-Murnaghan equation of state under assumption of K0' of 4. This value was subjected to compare with its structural analogs and related materials.

  • PDF

Analysis on Evaluation Method for Human Exposure to Electromagnetic Fields based on 2-ray Propagation Model (2-ray 전파모델을 적용한 전자파 인체노출 평가에 관한 고찰)

  • Cho, Kwanh-Yun;Yoon, Jae-Hoon
    • Proceedings of the KIEE Conference
    • /
    • 2008.10b
    • /
    • pp.419-420
    • /
    • 2008
  • 근래 무선통신기술의 발전으로 휴대폰 등, 무선기기의 사용이 급증하고 있으며, 주택가 인근에는 많은 무선기지국들이 시설되어 있다. 이러한 무선기기의 무선시설물은 목적한 바의 신호 송출을 위하여 전자파를 방출하고 있다. 본 논문에서는 무선기지국 안테나 근처에 서 있는 사람이 전자파에 노출될 때를 가정하여 2-ray 전파모델을 적용하려 참조규격의 전기장 강도 및 전력밀도를 산출하는 새로운 평가방법을 제시하고, 본 방법을 적용하여 일례의 전자파인체노출기준의 적합성을 평가한 결과를 분석, 고찰한다.

  • PDF

The average ray crossing position and the best focus (광선 교차점 평균과 최적초점)

  • 심상현;박성종;정창섭
    • Korean Journal of Optics and Photonics
    • /
    • v.7 no.4
    • /
    • pp.299-304
    • /
    • 1996
  • We numerically determined the direction of ray and the average ray-crossing position from the shape of the wavefront on the exit pupil of optical system which had aberrations and apodized aperture. This position was calculated easier and closer to the position of the maximum intensity than that calculated by Safa's method when the aberration is greater than about 2λ.

  • PDF

Development and Evaluation of Parallel Beam Optic for X-ray (엑스선용 평행빔 광학소자 개발 및 평가)

  • Park, Byunghun;Cho, Hyungwook;Chon, Kwonsu
    • Journal of the Korean Society of Radiology
    • /
    • v.6 no.6
    • /
    • pp.477-481
    • /
    • 2012
  • An X-ray diffractometer which has various X-ray optics can give qualitative and quantitative information for a sample using a nondestructive analysis method. A parallel beam optic passes the parallel beam and removes divergent beam generated from an X-ray tube. The parallel beam optic used in the X-ray diffractometer was fabricated by wire cut and grading of stainless steel plates and was evaluated its performance using an X-ray imaging system. The measured parallelization of 6.6 mrad for the fabricated the parallel beam optic was a very close to the expected value of 6 mrad. An X-ray imaging technique for evaluating the parallel beam optics can estimate parallelization for each plate and can be used to other X-ray optics.

Evaluation Method of Rock Characteristics using X-ray CT images (X-ray CT 이미지를 이용한 암석의 특성 평가 방안)

  • Kim, Kwang Yeom;Yun, Tae Sup
    • Tunnel and Underground Space
    • /
    • v.29 no.6
    • /
    • pp.542-557
    • /
    • 2019
  • The behavior of rock mass is influenced by its microscopic feature of internal structure generating from forming and metamorphic process. This study investigated a new methodology for characterization of rock based on the X-ray CT (computed tomography) images reflecting the spatial distribution characteristics of internal constituent materials. The X-ray image based analysis is capable of quantification of heterogeneity and anisotropy of rock fabric, size distribution and shape parameter analysis of rock mineral grains, fluid flow simulation based on pore geometry image and roughness evaluation of unexposed joint surface which are hardly acquired by conventional rock testing methods.