• Title/Summary/Keyword: Ray Method

Search Result 5,500, Processing Time 0.032 seconds

Assays of Residual Antibiotics after Treatment of γ-ray and UV Irradiation (감마선과 UV 조사에 의한 항생제 분해)

  • Shin, Ji-Hye;Nam, Ji-Hyun;Yu, Seungho;Lee, Myunjoo;Lee, Dong-Hun
    • Journal of Radiation Industry
    • /
    • v.4 no.1
    • /
    • pp.39-45
    • /
    • 2010
  • The pollution of antibiotics is a major cause of spreading antibiotics resistant bacteria in the environment. Applications of ozonation, UV, and ${\gamma}-ray$ irradiations have been introduced to remove antibiotics in the effluents from wastewater treatment system. In this study, we compared the chemical (HPLC) and biological (antimicrobial susceptibility test, AMS) assays in measuring of the concentrations of residual antibiotics after ${\gamma}-ray$ and UV irradiation. Most samples were degraded by ${\gamma}-ray$ irradiation (1~2 kGy). However, lincomycin and tetracycline were not degraded by UV irradiation. The concentration of residual antibiotics, that was treated with ${\gamma}-ray$ and UV irradiation, measuring by bioassay was similar to HPLC. The concentrations of ${\gamma}-ray$ irradiated cephradine measured by AMS test were 2 times higher than that of HPLC assay, indicating AMS test is more sensitive than HPLC assay. These results indicate that ${\gamma}-ray$ irradiation technique is more useful than UV irradiation, and biological assay is more useful to detect the antibiotics and toxic intermediates in antibiotics degradation.

A Study on Solid Electrolyte for New Type Cell (고체 전해질을 이용한 새로운 전지에 관한 연구)

  • Soung Ho Park;Seung Gu Cho;Keu Hong Kim;Yong Bae Kim;Jae Shi Choi
    • Journal of the Korean Chemical Society
    • /
    • v.30 no.6
    • /
    • pp.500-509
    • /
    • 1986
  • For the development of new type cell, a study on new electrolyte, $AgI-Ag_8S_3SO_4$ system has been carried out by using electrical conductivity measurement, DTA and X-ray powder diffraction method. From both X-ray powder diffraction and DTA method, it is clearly known that 20mole% $ Ag_8S_3SO_4$-AgI system forms single phase, having monoclinic structure. It is also found that 20mole% $Ag_8S_3SO_4$-AgI system is purely $ Ag^+ $cation conduction from results of conductivity measurement by applying 4-probe method.

  • PDF

Calibration-free real-time organic film thickness monitoring technique by reflected X-Ray fluorescence and compton scattering measurement

  • Park, Junghwan;Choi, Yong Suk;Kim, Junhyuck;Lee, Jeongmook;Kim, Tae Jun;Youn, Young-Sang;Lim, Sang Ho;Kim, Jong-Yun
    • Nuclear Engineering and Technology
    • /
    • v.53 no.4
    • /
    • pp.1297-1303
    • /
    • 2021
  • Most thickness measurement techniques using X-ray radiation are unsuitable in field processes involving fast-moving organic films. Herein, we propose a Compton scattering X-ray radiation method, which probes the light elements in organic materials, and a new simple, non-destructive, and non-contact calibration-free real-time film thickness measurement technique by setting up a bench-top X-ray thickness measurement system simulating a field process dealing with thin flexible organic films. The use of X-ray fluorescence and Compton scattering X-ray radiation reflectance signals from films in close contact with a roller produced accurate thickness measurements. In a high-thickness range, the contribution of X-ray fluorescence is negligible, whereas that of Compton scattering is negligible in a low-thickness range. X-ray fluorescence and Compton scattering show good correlations with the organic film thickness (R2 = 0.997 and 0.999 for X-ray fluorescence and Compton scattering, respectively, in the thickness range 0-0.5 mm). Although the sensitivity of X-ray fluorescence is approximately 4.6 times higher than that of Compton scattering, Compton scattering signals are useful for thick films (e.g., thicker than ca. 1-5 mm under our present experiment conditions). Thus, successful calibration-free thickness monitoring is possible for fast-moving films, as demonstrated in our experiments.

A Study on the Optimal X-ray Angle to Observe Calcaneus (발꿈치뼈를 관찰하기 위한 최적의 X-ray 각도에 대한 고찰)

  • Sang-Min Shin;Bo-Moon Seo;Hae-In Jeon;Gyoung-Han Lee;Min-Cheol Jeon
    • Journal of Advanced Technology Convergence
    • /
    • v.2 no.1
    • /
    • pp.17-21
    • /
    • 2023
  • In this study, using an X-ray device (Drgem TS-CSP) and foot phantom (SFT-1556), the angle of the X-ray tube was changed to 30°, 35°, 40°, 45°, and 50°, and the image was evaluated by quantitative and qualitative evaluation. In the blind test, it was the highest at 4.34 points at 40°, and in the part calculation using the Image J program, the angle was the largest at 1750 at 50°. In addition, in the area evaluation excluding overlapping areas, the X-ray tube showed the largest value at 40° Therefore, it was found that the X-ray tube angle was suitable when the X-ray tube angle was 40° as a projection method for observing the calcaneus.

Ray backpropagation-based ship localization (음선 역전파 기반의 선박 위치 추정)

  • Cho, Seong-il;Byun, Gihoon;Byun, Sung-Hoon;Kim, J.S.
    • The Journal of the Acoustical Society of Korea
    • /
    • v.37 no.4
    • /
    • pp.196-205
    • /
    • 2018
  • This paper presents an algorithm for passive localization of a ship by applying the ray back-propagation technique to the ship radiation noise data. The previous method [S. H. Abadi, D. Rouseff and D. R. Dowling, J. Acoust. Soc. Am. 131, 2599-2610 (2012)] estimates the position of a sound source in the near-field environment with no array tilt by using the RBD (Ray-based Blind Deconvolution) and ray back-propagation techniques. However, when there exists an array tilt, the above method leads to a large position estimation error. In order to overcome the problem, this study proposes an algorithm that estimates the position of a sound source by correcting the array tilt using the RBD and ray back-propagation techniques. The proposed algorithm was verified by using the ship noise of SAVEX15 (Shallow-water Acoustic Variability EXperiment in 2015) experimental data.

Performance Analysis of Low-level Radiation Shielding Sheet with Diamagnetic Nanoparticles

  • Cho, Jae-Hwan;Kim, Myung-Sam
    • Journal of Magnetics
    • /
    • v.20 no.2
    • /
    • pp.103-109
    • /
    • 2015
  • In this study, the authors attempted to produce a medical radiation shielding fiber that can be produced at a nanosize scale and that is, unlike lead, harmless to the human body. The performance of the proposed medical radiation shielding fiber was then evaluated. First, diamagnetic bismuth oxide, an element which, among elements that have a high atomic number and density, is harmless to the human body, was selected as the shielding material. Next, 10-100 nm sized nanoparticles in powder form were prepared by ball milling the bismuth oxide ($Bi_2O_3$), the average particle size of which is $1-500{\mu}m$, for approximately 10 minutes. The manufactured bismuth oxide was formed into a colloidal solution, and the radiation shielding fabric was fabricated by curing after coating the solution on one side or both sides of the fabric. The thicknesses of the shielding sheets prepared with bismuth oxide were 0.1, 0.2, 0.3, 0.4, 0.5, 0.6, 0.7, 0.8, and 1.0 mm. An experimental method was used to measure the absorbed dose and irradiation dose by using the lead equivalent test method of X-ray protection goods presented by Korean Industrial Standards; the resultant shielding rate was then calculated. From the results of this study, the X-ray shielding effect of the shielding sheet with 0.1 mm thickness was about 55.37% against 50 keV X-ray, and the X-ray shielding effect in the case of 1.0 mm thickness showed shielding characteristics of about 99.36% against 50 keV X-ray. In conclusion, it is considered that nanosized-bismuth radiation shielding fiber developed in this research will contribute to reducing the effects of primary X-ray and secondary X-ray such as when using a scattering beam at a low level exposure.

The Multi-layer Fabrication and Characteristic Performance for Dark Current Reduction of Mercury Iodide (Hgl2의 누설전류 저감을 위한 다층구조 제작 및 특성 평가)

  • Kim, Kyung-Jin;Park, Ji-Koon;Kang, Sang-Sik;Cha, Byung-Youl;Cho, Sung-Ho;Kim, Jin-Yung;Mun, Chi-Ung;Nam, Sang-Hee
    • Proceedings of the Korean Institute of Electrical and Electronic Material Engineers Conference
    • /
    • 2005.07a
    • /
    • pp.388-389
    • /
    • 2005
  • In this paper, the electric properties of mercury Iodide multi-layer samples has been investigated. We measured and analyzed their performance parameters such as the X-ray sensitivity and dark-current for a mercury Iodide multi-layer X-ray detector with a dielectric layer. The digital X-ray image detector can be constructed by integrating photoconduction multi-layer that dielectric layer has characteristics of low dark-current, high X-ray sensitivity. However this process has found to have complexity on the performance of the sample. We have investigate dielectric layer that it substitute dielectric layer for HgO(Mercury Oxide). We have employed two approaches for producing the mercury Iodide sample : 1) Physical Vapor Deposition(PVD) and 2) Particle-In-Binder(PIB). In this paper fabricated by PIB Method with thicknesses ranging from approximately 180um to 240um and we could produce high-quality samples for each technique particular application. As results, the dielectric materials such as HgO between the dielectric layer and the top electrode may reduce the dark-current of the samples. Mercury Iodide multi-layer having HgO has characteristics of low dark-current, high X-ray sensitivity and simple processing. So we can acquired a enhanced signal to noise ratio. In this paper offer the method can reduce the dark-current in the X-ray detector.

  • PDF

Acceleration of the SBR Technique using Grouping of Rays (광선 그룹화를 이용한 SBR 가속기법)

  • Lee, Jae-In;Yun, Dal-Jae;Yang, Seong-Jun;Yang, Woo-Yong;Bae, Jun-Woo;Kim, Si-Ho;Myung, Noh-Hoon
    • Journal of the Korea Institute of Military Science and Technology
    • /
    • v.21 no.6
    • /
    • pp.752-759
    • /
    • 2018
  • The SBR technique is one of the asymptotic high frequency method, where a dense grid of rays are launched and traced to analyze the scattering properties of the target. In this paper, we propose an accelerated SBR technique using grouping a central ray and 8 surrounding rays around the center ray. First, launched rays are grouped into groups consisting of a central ray and 8 surrounding rays. After the central ray of each group is preferentially traced, 8 surrounding rays are rapidly traced using the information of ray tracing for the central ray. Simulation result of scattering analysis for CAD models verifies that the proposed method reduces the computational time without decreasing the accuracy.

A study on thermal fluid analysis in X-ray tube for non-fire alarm (비화재보를 위한 X-ray tube 내 열 유동해석에 관한 연구)

  • Yun, Dong-Min;Jeon, Yong-Han
    • Design & Manufacturing
    • /
    • v.16 no.2
    • /
    • pp.33-38
    • /
    • 2022
  • Currently, Korea is an aging society, and it is expected to enter a super-aging society in about 4 years. Accordingly, many X-ray technologies are being developed. In X-rays, 99% of X-rays are converted into heat energy and 1% into light energy (X-rays). 99% of the thermal energy raises the temperature of the anode and its surroundings, and the cooling system is an important factor as overheating can affect the deterioration of X-ray quality and shortened lifespan. There is a method of forced air cooling using natural convection. Therefore, in this study, when X-rays were taken 5 times, Flow analysis was performed on heat removal according to temperature rise and cooling time for the heat generated at the anode of the X-ray tube (input power 60kW, 75kW, 90kW). Based on one-shot, the most rapid temperature rise section increased by more than 57% to 0.03 seconds, A constant temperature rises from 0.03 seconds to 0.1 seconds, It is judged that the temperature rises by about 8.2% or more at one time. After one-shot cooling, the cooling drops sharply from about 60% to 0.03 seconds, It is judged that the temperature has cooled by more than 86% compared to the temperature before shooting. One-shot is cooled by more than 86% with cooling time after 0.1 seconds, As the input power of the anode increases, the cooling temperature gradually increases. Since the tungsten of the anode target inside the X-ray tube may be damaged by thermal shock caused by a rapid temperature rise, an improvement method for removing thermal energy is required when using a high-input power supply.

Estimation of the optimal heated inlet air temperature for the beta-ray absorption method: analysis of the PM10 concentration difference by different methods in coastal areas

  • Shin, So Eun;Jung, Chang Hoon;Kim, Yong Pyo
    • Advances in environmental research
    • /
    • v.1 no.1
    • /
    • pp.69-82
    • /
    • 2012
  • Based on the measurement data of the particulate matter with an aerodynamic diameter of less than or equal to a nominal 10 ${\mu}m$ (PM10) by the ${\beta}$-ray absorption method (BAM) equipped with an inlet heater and the gravimetric method (GMM) at two coastal sites in Korea, the optimal inlet heater temperature was estimated. By using a gas/particle equilibrium model, Simulating Composition of Atmospheric Particles at Equilibrium 2 (SCAPE2), water content in aerosols was estimated with varying temperature to find the optimal temperature increase to make the PM10 concentration by BAM comparable to that by GMM. It was estimated that the heated air temperature inside the BAM should be increased up to $35{\sim}45^{\circ}C$ at both sites. At this temperature range, evaporation of volatile aerosol components was minor. Similar ($30{\sim}50^{\circ}C$) temperature range was also obtained from the calculation based on the absolute humidity which changed with ambient absolute humidity and chemical composition of hygroscopic species.