• Title/Summary/Keyword: Raw Water Turbidity

Search Result 144, Processing Time 0.023 seconds

Characteristics of the Non-electric Water Purification System Using Onggi Filter (옹기 필터를 이용한 무 전원 정수 장치에 관한 연구)

  • Wi, In-Hee;Shin, Dong-Wook;Han, Kyu-Sung;Kim, Jin-Ho;Cho, Woo-Seok;Hwang, Kwang-Taek
    • Journal of the Korean Ceramic Society
    • /
    • v.51 no.4
    • /
    • pp.332-336
    • /
    • 2014
  • A non-electric water purification system using the Korean traditional ceramic ware Onggi, was demonstrated as an appropriate technology to solve water shortages in under developed regions. Generally, Onggi is produced using large size raw materials that are sintered at low temperature, resulting in a porous body that shows air and water permeability. An Onggi filter was prepared using a spinning wheel with the addition of rice bran to the body to increase porosity. The porosity of the obtained Onggi filter was 25.1%; the water permeability was 85.1 $L/m^2h$. Turbidity and TDS of the purified water using Onggi filter were decreased by 97.7% and 29.1%, respectively.

Evaluation of raw wastewater characteristic and effluent quality in Kashan Wastewater Treatment Plant

  • Dehghani, Rouhullah;Miranzadeh, Mohammad Bagher;Tehrani, Ashraf Mazaheri;Akbari, Hossein;Iranshahi, Leila;Zeraatkar, Abbas
    • Membrane and Water Treatment
    • /
    • v.9 no.4
    • /
    • pp.273-278
    • /
    • 2018
  • Due to the lack of water in arid and semi-arid areas, reuse of wastewater can be a suitable way to compensate for water scarcity. Therefore, in this research, evaluation of the quality of wastewater of Kashan Treatment Plant to use for irrigation was studied. This descriptive cross-sectional study was conducted in 2016. pH, TSS, TDS, turbidity, COD, BOD5, Total Kjeldahl Nitrogen, Total Phosphorus, Total Coliform, fecal coliform, nematode eggs of inlet and outlet of wastewater treatment plant in Kashan were studied. Mean and standard deviation and wastewater quality parameters before and after treatment were tested with SPSS 22 (2014) software. The mean wastewater output of COD, BOD5, TSS, TDS and turbidity were respectively 86.6, 41.2, 11.11, 1095 mgL-1 and 17.5 NTU and the pH was equal to 7.22. Also, the average of Total Kjeldahl Nitrogen and phosphorus were 22.4 and 2.2 mgL-1 respectively. The mean of Total Coliform and fecal coliform were 225, 161 MPN / 100 ml respectively. In addition, no nematode eggs were found in final effluent. The results indicated that the treatment plants had a significant role in the control of microbial and organic pollution load of wastewater. Also, it is concluded that all parameters were in accordance with the standards of Iran's Department of Environment, so, it can be used for unrestricted irrigation.

Evaluation of Streaming Current Detector (SCD) and Charge Analyzing System (CAS) for automation of coagulant dosage determination (낙동강 하류 원수의 응집제 주입 자동화를 위한 Streaming Current Detector (SCD)와 Charge Analyzing System (CAS)의 평가)

  • Kim, Sang-Goo;Son, Hee-Jong;Lee, Jeong-Kyu;Yeom, Hoon-Sik;Yoo, Pyung-Jong
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.39 no.4
    • /
    • pp.201-207
    • /
    • 2017
  • This study was conducted to investigate the characteristics of the stream current detector (SCD) and charge analyzing system (CAS), which are well known as the automatic coagulant dosage determination instruments. When the SCD system was used, the current charge value set at pH 9.3 could not be used as the coagulant dosage when the pH of the raw water decreased to 5.7, and the current charge value corresponding to pH 5.7 was required to be reset. In case of CAS system, polydadmac is stable as a cationic titrant when the pH of the raw water ranged 9.3 to 6.0. And it was effective to use polydadmac as a cationic titrant for high turbidity water. The current charge of polydadmac was almost constant between pH 5 and 11, however, the difference in charge of alum is six times in this pH range. Therefore, when the pH of the raw water was changed, it seems that the coagulant used in the actual water treatment plant was as a good cationic titrant.

Pollutant Removal and Characteristic of Floc by Alum Coagulation (응집 현상에 따른 오염물질 제거 및 입자 형태 특성: Alum을 사용한 경우)

  • Moon, Byung-Hyun;Kim, Seung-Hyun;Lee, Hyang-In
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.22 no.7
    • /
    • pp.1263-1271
    • /
    • 2000
  • This study investigated the floc structure and removal of turbidity and organic matter by alum coagulation. Results of this study indicated that sweep floc and charge neutralization area were shifted to more acidic region than that in the Amirtharajah's diagram. This was caused by organic matter present in the raw water. Removal regions of turbidity and organic matter were generally overlapped. However, organic matters was removed better at lower pH than turbidity. Floc structure was characterized by measuring fractal dimension and volume diameter using AIA and SALLS. SALLS method was found to be more reliable than AIA method. Floes in sweep floc region had larger size and fractal dimension than flocs in charge neutralization region. As pollutant removal increased, larger fractal dimension and size of floc were measured.

  • PDF

Optimization of Coagulation and Media Filtration Process for Low Turbidity Seawater (저탁도 해수원수 특성에 적합한 응집 - 여과 공정의 최적화)

  • Son, Dong-Min;Jo, Myeong-Heum;Kim, Jeong-Sook;Kang, Lim-Seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.36 no.4
    • /
    • pp.251-257
    • /
    • 2014
  • This research is focused on coagulation and sand filtration process as a pretreatment of RO seawater desalination. RO systems require sufficient and reliable pretreatment process to produce superior quality of RO feedwater that can mitigate RO membrane fouling. This experiment was conducted to investigate the effectiveness of coagulation and filtration process under various experimental conditions including different coagulant dose, flocculation mixing intensity and time, turbidity, and filtration rate. The experimental results showed that the optimum pretreatment conditions resulting in lower SDI value suitable for RO feedwater were coagulation pH 6.5, raw water turbidity greater than 4 NTU, and media bed depth greater than 550 mm. However, flocculation mixing intensity, coagulant dose, and filtration rate relatively affected little on the filtration efficiency.

A Study on Formation Pattern of DBPs by Disinfection of Drinking Raw Water II (음용 원수의 염소소독에 의한 소독부산물 생성패턴에 관한 연구 II)

  • Lee, Kang Jin;Hong, Jee Eun;Pyo, Heesoo;Park, Song-Ja;Yoo, Je Kang;Lee, Dae Woon
    • Analytical Science and Technology
    • /
    • v.17 no.1
    • /
    • pp.69-81
    • /
    • 2004
  • The formation pattern of DBPs (disinfection by-products) in raw water treated with hypochlorite, chlorine disinfectant was studied. TOC (total organic carbon), residual chlorine, turbidity and 14 DBPs in raw water from Han-river and Nakdong river during 1 ~ 14 days were determined. Total DBPs in Han river was 101.3 ng/mL (789.6 nM) after 7days and THMs (trihalomethanes) are the dominant portion of 68%. HAAs (haloacetic acids) and chloral hydrate were determined 19% and 10% respectively. In Nakdong river total DBPs was 98.4 ng/mL (678.6 nM) and dominant class was HAAs. (55.8 ng/mL, 57%) THMs(34%) and N-compounds like HANs (haloacetonitriles, 5%) and chloropicrin were increased. It may be explained that high concentration of NH4-N in Nakdong river react with chlorine produced chloramine and this formed different pattern of DBPs. As a result, total DBPs formation pattern depends on raw water and disinfectant and in generally the initial concentration of acidic HAAs was high and THMs was increased gradually.

Comparison of Al(III) and Fe(III) Coagulants for Improving Coagulation Effectiveness in Water Treatment (정수처리 응집효율 개선을 위한 Al(III)염과 Fe(III)염 응집제의 비교)

  • Han, Seung woo;Kang, Lim seok
    • Journal of Korean Society of Environmental Engineers
    • /
    • v.37 no.6
    • /
    • pp.325-331
    • /
    • 2015
  • The experimental results of the characteristics of aluminum based and ferric based coagulants for the Nakdong River water showed that the main hydrolysis species contained in alum and $FeCl_3$ are monomeric species of 98% and 93.3%, respectively. The PACl of r=1.2 produced by the addition of base contained 31.2% of polymeric Al species and the PACl of r=2.2 contained 85.0% of polymeric Al species, as showing more polymeric Al species with increasing r value. Coagulation tests using Al(III) and Fe(III) salts coagulants for the Nakdong River water showed that the coagulation effectiveness of turbidity and organic matter was high in the order of $FeCl_3$ > PACl (r=2.2) > PACl (r=1.2) > alum. $FeCl_3$ has showed better flocculation efficiency than Al(III) salts coagulants. In addition, in case of Al(III) coagulants, the Al(III) coagulants of higher basicity, which contained more polymeric Al species, resulted in better coagulation efficiency for both turbidity and organic matter removed. The optimum pH range for all of the coagulants investigated was around pH 7.0 under the experimental pH range of 4.0~9.5. Especially, the highest basicity PACl (r=2.2) and $FeCl_3$ were considered as more appropriate coagulants for the removal of turbidity in the case of raw water exhibiting higher pH.

A Study on the improvement of Chemicals Dosing Performance using Neural network in a Purification Plant (신경회로망을 이용한 상수처리설비의 약품주입 성능개선에 관한 연구)

  • 류승기;최도혁;홍규장;문학룡;한태환;유정웅
    • Journal of the Korean Institute of Illuminating and Electrical Installation Engineers
    • /
    • v.12 no.3
    • /
    • pp.104-113
    • /
    • 1998
  • In genral, the water process facilities include the purification plant, the waste water plant and the process of this purification plant is consisted of the intake, coagulation, settling, filtration, disinfection. The coagulation is very important in filtration processing plant and is very related to process of turbidity. The coagulation to the turbidity is, however, not yet to be clarified and the amount of coagulant can not be easily calculated. Moreover the coagulant dosing amount has to be decided adaptively according to the qualities of the raw water. So, the automation of chemicals dosing process and the supervisory system were needed to improve the performance of facilities. In this paper, a neural network is employed to model the coagulation to the turbidity of the treated water and the historical jar-test data are used to train the neural network. And also, an automation system to support the coagulant dosing process using the neural network was implemented and was shown by the field test. This automation system for the operator support system was constructed the environment to supervise the state an management of facilities for the maintenance.

  • PDF

Shelf-life Extension of Raw Oyster Crassostrea gigas by Depuration Process (인공정화에 의한 참굴(Crassostrea gigas)의 유통기한 연장)

  • Lee, Do-Ha;Kang, Dong-Min;Park, Seul-Ki;Jeong, Min-Chul;Kang, Min-Gyun;Jo, Du-Min;Lee, Jae-Hwa;Lee, Da-Eun;Sim, Yoon-Ah;Jeong, Geum-Jae;Cho, Kyung-Jin;Kim, Young-Mog
    • Korean Journal of Fisheries and Aquatic Sciences
    • /
    • v.53 no.6
    • /
    • pp.842-850
    • /
    • 2020
  • The objective of this study was to evaluate the effect of the depuration process (artificial seawater sterilization using UV light) for extending the shelf life of raw oyster Crassostrea gigas and maintaining food quality. To confirm the effects of depuration, microbiological (viable cell count) and several physiochemical analyses (pH and glycogen levels in shucked oyster and pH, soluble protein, and turbidity in filling water) were carried out during the storage of raw oysters. The results showed that depuration could effectively extend the shelf life (2-3 days) of raw oysters with minimal change in food quality, including pH and glycogen content. Thus, the depuration process proposed in this study could successfully be applied to processing practices for other shellfish to extend their shelf life and contribute to the management of seafood safety issues.

Water Quality Change Characteristics of Treated Water in Distribution System of Water Treatment Plant of Jeiu City (제주시 정수장 처리수의 급수과정별 수질변화 특성)

  • Han, Kyung-Yong;Lee, Min-Gyu;Chung, Ho-Jin;Kam, Sang-Kyu
    • Journal of Environmental Science International
    • /
    • v.16 no.1
    • /
    • pp.81-94
    • /
    • 2007
  • The purpose of this work is to investigate the water quality change characteristics of treated water in water distribution systems of Water Treatment Plants (WTPs) of Jeju City. For this, the raw water, treated water and tap water that did not pass (named as not pass-tap water) and passed through the water storage tank (named as pass-tap water) were sampled and analyzed monthly from September 2001 to August 2002, for four (W, S, B and O) WTPs except for D WTP (where treated water is not supplied continuously) among WTPs of Jeju City. The concentrations of $NO_3^-$ and $Cl^-$ of treated water in distribution systems changed little, but changed seasonally, which is considered to be based on the seasonal variation of the quality of raw water. The pH of treated water changed little in distribution systems for S WTP, but for the other WTPs, the pH of not pass-tap water was similar to that of treated water and the pH of pass-tap water was higher than that of treated water. The turbidity of treated water in distribution systems changed little except for W2 of W WTP and S4 and S5 of S WTP, where it was higher than that of each treated water. The residual chlorine concentrations between treated water and not pass-tap water changed little, but those between treated water and pass-tap water changed greatly, based on the its long residence time in water storage tank and so its reaction with organic matter, etc or its evaporation. The concentrations of TTHMs (total trihalomethanes) and $CHCl_3$ that induce cancers in water distribution systems of these WTPs, were much lower than their water quality criteria and those in other cities. The concentrations of TTHMs of treated water and not pass-tap water were similar, but concentrations of pass-tap water were 1.5 to 2.0 times higher than those of treated water and not pass-tap water, due to the reaction of residual chlorine and organic matter, etc, with the result of long residence time in water storage tank.