Pollutant Removal and Characteristic of Floc by Alum Coagulation

응집 현상에 따른 오염물질 제거 및 입자 형태 특성: Alum을 사용한 경우

  • Moon, Byung-Hyun (Dept. of Environ. Eng., Changwon National University) ;
  • Kim, Seung-Hyun (Dept. of Architectural, Civil and Environ. Eng., Kyungnam University) ;
  • Lee, Hyang-In (Dept. of Environ. Eng., Changwon National University)
  • 문병현 (창원대학교 환경공학과) ;
  • 김승현 (경남대학교 공간환경시스템공학부) ;
  • 이향인 (창원대학교 환경공학과)
  • Received : 2000.02.02
  • Accepted : 2000.04.17
  • Published : 2000.07.31

Abstract

This study investigated the floc structure and removal of turbidity and organic matter by alum coagulation. Results of this study indicated that sweep floc and charge neutralization area were shifted to more acidic region than that in the Amirtharajah's diagram. This was caused by organic matter present in the raw water. Removal regions of turbidity and organic matter were generally overlapped. However, organic matters was removed better at lower pH than turbidity. Floc structure was characterized by measuring fractal dimension and volume diameter using AIA and SALLS. SALLS method was found to be more reliable than AIA method. Floes in sweep floc region had larger size and fractal dimension than flocs in charge neutralization region. As pollutant removal increased, larger fractal dimension and size of floc were measured.

Alum을 이용한 응집 과정에서 탁도 및 유기물 제거와 응집 floc의 특성을 파악하였다. 본 실험에서 구한 탁도 제거영역을 Amitharajah의 연구결과와 비교했을 때 sweep floc 및 charge neutralization의 제거영역이 낮은 pH 영역으로 이동하였는데 그 원인은 원수에 포함된 유기물 농도가 다른데서 찾을 수 있다. 대체적으로 탁도 및 유기물($UV_{254}$와 TOC)의 제거영역은 비슷하였으나 탁도 제거에 비해 낮은 pH에서 유기물 제거의 효과가 높았다. Floc의 특성은 AIA, SALLS 방법을 이용하여 volume diameter과 fractal dimension을 측정하였다. AIA 방법에 비해 SALLS 방법의 측정이 용이하고 신뢰성도 높았다. SALLS 방법을 이용하여 floc을 측정한 결과 sweep floc 영역의 floc이 charge neutralization 영역의 floc 보다 fractal dimension과 평균 직경이 크게 측정되었으며, 오염물질의 제거율이 높을수록 floc의 fractal dimension과 평균 직경도 크게 나타났다.

Keywords