The Optimization of Removal Process of Humic Acid by Polysulfone Hollow-fiber Membrane
폴리설폰 중공사막에 의한 부식산 제거공정의 최적화
- Song, Kun-Ho (Dept. of Chemical Engineering, Kangwon National University) ;
- Lee, Kwang-Rae (Dept. of Chemical Engineering, Kangwon National University) ;
- Lee, Chan-Ki (Dept. of Environmental Engineering, Kangwon National University)
- Received : 2000.02.11
- Accepted : 2000.04.17
- Published : 2000.07.31
Abstract
In this study, ultrafiltration was performed to remove humic acid from aqueous solution. Since the effects of system variables on the ultrafiltration were tangled with non-linearly. Response Surface Methodology(RSM) was used to know optimum conditions of ultrafiltration process, relations among system variables, and the effects of system variables such as pressure difference across the membrane, concentration of humic acid, and feed flow rates. As concentrations of humic acid were 10ppm, 40ppm, and 70ppm in feed stream, permeation fluxes were 2.56, 2.27, and
본 연구에서는 한외여과막을 이용하여 수중에 함유되어 있는 부식산의 제거실험을 수행하였다. 한외여과성능에 미치는 공정변수들의 영향이 비선형적으로 서로 얽혀 있기 때문에, 응답표면분석법(RSM)을 이용하여 분리막 공정의 최적화와 각 변수간의 상호관계 및 투과성능에 영향을 미치는 공정변수(압력, 농도, 유량 등)들이 분리성능에 미치는 영향을 분석하였다. 부식산용액의 공정변수에 대한 투과량의 변화는 유입용액의 부식산의 농도가 10ppm, 40ppm 70ppm으로 증가함에 따라 2.56, 2.27,