• 제목/요약/키워드: Raw Water Turbidity

검색결과 143건 처리시간 0.014초

고탁도시 DAF 정수장의 운영 및 진단 (Operation and Diagnosis of DAF Water Treatment Plant at Highly Turbid Raw Water)

  • 권순범;안효원;강준구;손병용
    • 상하수도학회지
    • /
    • 제18권2호
    • /
    • pp.191-200
    • /
    • 2004
  • DAF process has been designed considering raw water quality characteristics in Korea. Although direct filtration is usually operated, DAF is operated when the freshwater blooms occut or raw water turbidity become high. Pre-sedimentation iS prepared in case when raw water turbidity is very high by rainstorms. A main feature of this plant is that the operation mode can be changed (controlled) based on the characteristics of raw water to optimize the effluent quality and the operation costs. Treatment capacity (surface loading rate) and efficiency of DAF was found to be better than conventional sedimentation process. Moreover, low-density particles (algae and alum flocs) are easily separated while it is difficult to remove in sedimentation. One of the main concerns in adoption of DAF (Dissolved Air-Flotation) process is a high raw water turbidity problem. That is, DAF is not adequate for raw water, which is more turbid than 100NTU. In order to avoid this problem, pre-sedimentation basins are prepared in DAF plant to decrease the turbidity of DAF influent. For simulation of the actual operation, bench and full-scale tests were performed for highly turbid water conditions. Consequently, DAF process coupled with sedimentation is suggested that pre-sedimentation with optimum coagulation prior to DAF would be appropriate.

원수 수질특성과 응집제 염기도에 따른 응집 pH 및 주입량의 영향 (The Effects of pH and Dosages According to Qualities of Raw Waters and Basicity of Coagulants)

  • 박노백;이범;전동걸;이영주;전항배
    • 상하수도학회지
    • /
    • 제24권5호
    • /
    • pp.581-593
    • /
    • 2010
  • The objectives of this study were to investigate the effects of raw water pH and basicity of coagulants on turbidity removal with several raw waters having different level of turbidity, alkalinity and pH. Raw waters were sampled from M, S and B water treatment plants(WTP) located at Miryang, Nakdong, Han river, respectively. Six coagulants which have different levels of basicity and aluminum contents were used for this evaluation. High basicity of the coagulant helped to properly control coagulation processes for treating turbid and low alkali raw water. It was difficult for operators to determine optimum coagulant dose for high basicity coagulants, since residual turbidity tended to decrease continuously as coagulant dose increased. Turbidity removal efficiencies with high basicity coagulants(E and F) were higher than the other coagulants at ambient pH for the M WTP. Turbidity removal efficiencies, however, at adjusted pH 7.0 showed similar among six coagulants. Residual turbidity kept low at excess dosages with high basicity coagulants. Optimum coagulant dosages at adjusted pH 7.0 showed higher than those at ambient pH in M WTP. On the contrary in B WTP, optimum coagulant dosage at ambient pH were higher than that at adjusted pH 7.0.

제주도 기후변화 관련 상수도시설 취약성 평가 및 적응대책 (Water utilities vulnerability assessment and adaption strategies for climate change in Jeju province)

  • 김진근
    • 상하수도학회지
    • /
    • 제32권6호
    • /
    • pp.517-526
    • /
    • 2018
  • Climate adaptation strategies for water utilities including 16 water treatment plants(WTPs) in Jeju were investigated. Drought, heat wave, and heavy rain were among the most significant climate factors affecting water utilities in Jeju. Heat wave increases water temperature, which in turn increases the concentration of algae, color, and odor materials. Some adaption strategies for the heat wave can be strengthening water monitoring and introducing advanced water treatments. Heavy rain increases raw water turbidity in surface water. The 7 WTPs that take raw water from streams or springs had a maximum turbidity of less than 50 NTU under heavy rain. However, due to concerns of turbidity spike in treated water, some WTPs discontinued intaking raw water when raw water turbidity increased more than 2 NTU. They instead received treated water from other WTPs which took groundwater for water supply. This happens because of the low skills of employees. Thus, there needs to be an increase in operator competency and upgrade of water facilities for the adaption of heavy rain. To improve adaption for the drought, there should be an increase in the capacity of intake facilities of surface water as well as a decrease in water loss. In addition, water consumption per person should be decreased.

한강수계의 수문자료와 원수탁도의 상관관계 분석 (Analysis on the Correlation between Hydrological Data and Raw Water Turbidity of Han River Basin)

  • 정안철;강태운;김성원;정관수
    • 한국수자원학회논문집
    • /
    • 제49권1호
    • /
    • pp.1-9
    • /
    • 2016
  • 원활한 용수공급과 정수장의 효율적이고 경제적인 설계 유지 관리를 위해서 한강수계에 위치하고 있는 두 광역정수장의 원수탁도와 수문자료간의 상관관계를 분석하였다. 광역정수장의 취수원인 댐의 유입유량, 방류량, 강우를 수문자료로서 활용하였으며, 상관관계 분석을 위해서는 상관분석과 주성분분석 기법을 이용하였다. 또한, 탁도변화를 예측할 수 있는 회귀식을 제안하여 탁도 변화 예측을 수행하였다. 충주정수장의 원수탁도는 충주댐의 방류량(0.708)과 와부정수장의 원수탁도는 팔당댐의 유입량(0.805)과 높은 상관성이 높은 것으로 확인되었다. 상관성이 높은 시계열자료를 이용하여 제안한 회귀식의 탁도 예측치는 상수도시설기준에서 제시하고 있는 원수탁도 산정방법을 이용한 경우와 유사한 결과를 도출하였다. 본 연구의 결과는 장래의 원수탁도를 예측하여 추가적인 정수장 건설 및 기존 정수장의 효율적인 유지 관리를 위한 기초 자료를 제공할 수 있을 것으로 판단된다.

폴리염화알루미늄 과량주입에 의한 고(高) pH 원수의 수처리효율 개선 (Improvement of Water Treatment Efficiency by Poly Aluminum Chloride Overdosing in High pH Raw Water)

  • 임재철;김진근
    • 상하수도학회지
    • /
    • 제23권1호
    • /
    • pp.39-46
    • /
    • 2009
  • A method to improve water treatment efficiency by coagulant overdosing for high pH raw water at a drinking water treatment plant (WTP) which had no pH adjusting facilities was investigated. Poly aluminum chloride (PACl) was used for coagulant, and turbidity removal efficiency was evaluated as a function of PACl dosage increases. pH and turbidity of supernatant of jar-tester were 7.10 and 0.50 NTU respectively, when the turbidity, pH, alkalinity, water temperature, conductivity of raw water were 1.75 NTU, 9.38, 46.5 mg/L, $6.4^{\circ}C$, $400{\mu}s/cm$, respectively. Turbidity of settled water was reduced from 2.18 NTU to 0.28 NTU (87% reduction) when PACl dosage was increased from 16 mg/L to 45 mg/L at a full scale WTP. This can be attributed to the recovery of coagulant efficiency by pH reduction with the increase of coagulant dose, however coagulation efficiency was reduced with the formation of Al(OH)4- by PACl addition at higher pH. Coagulant overdosing was proven to be a rapid and effective method for high pH raw water, which can be applied at drinking WTP.

회수수가 응집공정의 오염물질 제거 및 입자특성에 미치는 영향 (Effects of Recycled Washwater on Pollutant Removal and Particle Characteristics during Coagulation)

  • 문병현;김승현;박미선;이향인;이강춘
    • 한국환경과학회지
    • /
    • 제11권9호
    • /
    • pp.955-960
    • /
    • 2002
  • The recycled washwater, which has different water quality and is produced about 5 to 20% of the total water volume treated, affects the unit operation of water treatment, especially coagulation process. However, the effects of recycled washwater on unit operation of water treatment have not been fully investigated. In this study, effects of recycled washwater on coagulation process were investigated to find the optimum coagulation condition by analyzing turbidity, $UV_{254}$, TOC removal efficiencies. In addition, effects of recycled washwater on residual Al after coagulation were studied by analyzing soluble and particulate Al. The size distribution and fractal dimension of coagulated also analyzed. The recycled washwater was lower pH than the raw water. And the recycled washwater had higher $UV_{254}$, TOC and residual Al concentration than the raw water. Residual Al concentration of recycled washwater was about 50 times higher than that of raw water. Optimum coagulant dosages on the blending recycled washwater and the raw water for turbidity, $UV_{254}$ and Al removal were lower than that on the raw water. However, TOC removal increased by increasing coagulant dosage. The size and fractal dimension of coagulated particle produced in the blending recycled washwater were larger, which imply faster settling velocity, than those produced in the raw water only.

정수처리공정의 침전법을 개선하기 위한 대체공정으로 용존공기부상법(DAF)을 사용할 때 여러조건에 대한 처리효율 비교 (Comparison of Removal Rates of Sedimentation and DAF(Dissolved Air Flotation) for various Different Conditions in Water Treatment)

  • 김미정;이병호
    • 상하수도학회지
    • /
    • 제11권4호
    • /
    • pp.118-125
    • /
    • 1997
  • Conventional sedimentation method has some limitations for turbidity removal in water treatment because drinking water sources are getting polluted. Removal rates of turbidity using DAF and sedimentation process were compared for various water conditions to know whether DAF is effective to improve sedimentation process. Water samples were clay(gravity 2.65) water 100mg/l, H raw water, mixed water of H raw water and clay 100mg/l, and mixed water of HA(Humic Acid) 5mg/l and clay 100mg/l. Other parameters were temperature, coagulants(Alum, $FeCl_3$), and treatment time. Water temperature greatly affected in removal rates of turbidity for sedimentation and DAF. Generally DAF was more effective in removal rates of turbidity than sedimentation at the same experimental condition. Removal rates of $UV_{254}$ were high to over 90%, and independent of temperature and coagulant.

  • PDF

고탁도 원수의 침전효율 증대를 위한 수평류식 핀 경사판 적용에 관한 연구 (Application of Horizontal Flow Fins Inclined Plate for Sedimentation Efficiencies Improvement in River Water with High Turbidity)

  • 최정수;진오석;주현종
    • 대한환경공학회지
    • /
    • 제34권9호
    • /
    • pp.644-650
    • /
    • 2012
  • 본 연구에서는 고탁도 원수의 효율적인 처리를 위해 수평류식 핀 부착 경사판(HFIP)을 설치하여 그에 따른 적용성을 평가하는데 목적을 두었다. 실험결과는 저탁도 원수 유입의 경우 HFIP 적용 후에 0.34 NTU의 방류수질과 90.45%의 제거효율을 나타냈다. 고탁도 원수의 경우에는 0.75 NTU의 방류수질과 97.27%의 제거효율을 나타냈다. 방류수질 안정성 측면에서는 HFIP 적용 후 0.12 NTU(저탁도 원수), 0.75 NTU(고탁도 원수)의 표준편차를 보였으며, 설치 전과 비교하여 방류수질 변동 폭이 상당히 개선된 것으로 나타났다. 이러한 결과는 HFIP 설치로 인해 수류 속도 분포의 안정화와 침강효율이 증가하였기 때문인 것으로 판단된다.

2단 망간모래여과에 의한 고농도 망간 처리 (Removal of High Concentration Manganese in 2-stage Manganese Sand Filtration)

  • 김충환;윤종섭;임재림;김성수
    • 상하수도학회지
    • /
    • 제21권4호
    • /
    • pp.503-508
    • /
    • 2007
  • Small scale D-water treatment plant(WTP) where has slow sand filtration was using raw water containing high concentration of manganese (> 2mg/l). The raw water was pre-chlorinated for oxidation of manganese and resulted in difficulty for filtration. Thus, sometimes manganese concentration and turbidity were over the water quality standard. Two stage rapid manganese sand filtration pilot plant which can treat $200m^3/d$ was operated to solve manganese problem in D-WTP. The removal rate of manganese and turbidity were about 38% and 84%, respectively without pH control of raw water. However, when pH of raw water was controlled to average 7.9 with NaOH solution, the removal rate of manganese and turbidity increased to 95.0% and 95.5%, respectively and the water quality of filtrate satisfied the water quality standard. Manganese content in sand was over 0.3mg/g which is Japan Water Association Guideline. The content in upper filter was 5~10 times more than that of middle and lower during an early operation but the content in middle and lower filter was increased more and more with increase of operation time. This result means that the oxidized manganese was adsorbed well in sand. Rapid manganese sand filter was backwashed periodically. The water quality of backwash wastewater was improved by sedimentation. Thus, turbidity and manganese concentration decreased from 29.4NTU to 3.09NTU and from 1.7mg/L to 0.26mg/L, respectively for one day. In Jar test of backwash wastewater with PAC(Poly-aluminum chloride), optimum dosage was 30mg/L. Because the turbidity of filtrate was high as 0.76NTU for early 5 minute after backwash, filter-to-waste should be used after backwash to prevent poor quality water.

공극제어형 섬유사 여과기를 이용한 복류수의 탁도 제거효율 평가 (Evaluation of Turbidity Removal Efficiency on under Flow Water by Pore Controllable Fiber Filtration)

  • 김정현;배철호;김충환;박노석;이선주;안효원;허현철
    • 상하수도학회지
    • /
    • 제19권2호
    • /
    • pp.135-143
    • /
    • 2005
  • It was evaluated that the effect of turbidity removal by Pore Controllable Fiber Filter(PCF) installed in NS(Naksang) small water treatmant plant(system) using under flow water as raw water in the study. The results of the study are as the followings. Firstly, the removal efficiency of turbidity by PCF without coagulation(in operation mode not using coagulants) was mostly below 20 percent. On the other hand, when operation using proper coagulants, that of turbidity was mostly over 80 percent. Secondly, slow sand filtration after PCF, total turbidity removal efficiency of final treated water was 84.3 percent, and the contribution by PCF was 57.1 percent and that of slow sand filtration was 27.7 percent. Therefore the introduction of PCF as pre-treatment process would be helpful to reduce the loading of high turbidity of slow sand filtration. Thirdly, the results of particle counter measurements showed that when operated PCF with coagulants, fine flocs captured or adsorbed at the pore of PCF were flow out into the effluents from 120 minutes after backwashing because of the increase of headloss of PCF. Therefore the decision of backwashing time should made consideration into the outflow of fine flocs from PCF. Fourth, coagulant dosages on PCF at the same turbidity was largely variable because of the effect of the raw water characteristics and the turbidity increase velocity at rainy days, therefore flexible coagulant dosages should be considered rather than fixed coagulant dosage by the influent jar-test result.