Abstract

It was evaluated that the effect of turbidity removal by Pore Controllable Fiber Filter(PCF) installed in NS(Naksang) small water treatmant plant(system) using under flow water as raw water in the study. The results of the study are as the followings. Firstly, the removal efficiency of turbidity by PCF without coagulation(in operation mode not using coagulants) was mostly below 20 percent. On the other hand, when operation using proper coagulants, that of turbidity was mostly over 80 percent. Secondly, slow sand filtration after PCF, total turbidity removal efficiency of final treated water was 84.3 percent, and the contribution by PCF was 57.1 percent and that of slow sand filtration was 27.7 percent. Therefore the introduction of PCF as pre-treatment process would be helpful to reduce the loading of high turbidity of slow sand filtration. Thirdly, the results of particle counter measurements showed that when operated PCF with coagulants, fine flocs captured or adsorbed at the pore of PCF were flow out into the effluents from 120 minutes after backwashing because of the increase of headloss of PCF. Therefore the decision of backwashing time should made consideration into the outflow of fine flocs from PCF. Fourth, coagulant dosages on PCF at the same turbidity was largely variable because of the effect of the raw water characteristics and the turbidity increase velocity at rainy days, therefore flexible coagulant dosages should be considered rather than fixed coagulant dosage by the influent jar-test result.

Keywords

References

  1. Gary, S.L., Slow Sand Filtration, ASCE, New York, USA (1991)
  2. Poynter, S.F.B., and Slade, J.S., 'The removal of viruses by slow sand filtration', Progress in Water Technology, 9, 75-38 (1997)
  3. Biologically Enhanced Slow Sand Filtration for Removal of Natural Organic Matter, AWWA (1993)
  4. Grabbe, U., Seyfried, C. F. and Rosenwinkel, K. H., (1998), 'Upgrading of wastewater treatment plants by cloth-filtration using an improved type of filter-cloth', Water Science Technology, 37(9), 143-150 https://doi.org/10.1016/S0273-1223(98)00282-0
  5. 전항배, 이영주, 신승식, '표면처리된 완속여과 시스템에서 입자 및 자연유기물(NOM)의 제거 특성 연구', 대한 환경공학회지, Vol.25, No, 9. pp. 1132-1137 (2004)
  6. 이무재, 임정수, 이상덕, 박덕수, 김기진, 전항배, '활성탄 소섬유 필터를 이용한 고도정수처리시스템에 관한 기초연구(I)', 대한환경공학회 춘계 학술발표회 논문집, pp.353-354 (2003)
  7. 임정훈, 김효관, 문태섭, 김지원, 우혜진, 김창원, '충전밀도와 HRT에 따른 섬유사 여과기의 처리성능 변화', 대한환경공학회 추계 학술발표회 논문집, pp. 1309-1314 (2003)
  8. 김지원, 유상웅, 박성호, 한기백, 우혜진, '3FM 여과기를 이용한 하천수질 개선연구'. 대한환경공학회 추계 학술 발표회 논문집, pp.1439-1440 (2003)