• Title/Summary/Keyword: Ratio of the Window

Search Result 401, Processing Time 0.031 seconds

Performance Evaluation of a Peak Windowing-Based PAPR Reduction Scheme in OFDM Polar Transmitters (OFDM polar transmitter에서 피크 윈도잉 기반의 PAPR 감소기법의 성능평가)

  • Seo, Man-Jung;Shin, Hee-Sung;Im, Sung-Bin;Jung, Jae-Ho;Lee, Kwang-Chun
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.45 no.12
    • /
    • pp.42-48
    • /
    • 2008
  • Next generation wireless communication systems require RF transceivers that enable multiband/multimode operations. Polar transmitters are known as good candidates for high data rate systems such as EDGE (Enhanced Data Rates for GSM Evolution), WCDMA (Wideband Code Division Multiple Access), and WLAN (Wireless Local Area Network) because they can obtain high efficiency by using efficient switched-mode RF power amplifiers. In this paper, we investigate the performance of a simple peak windowing scheme for the OFDM (Orthogonal frequency Division Multiplexing) polar transmitter, which requires no change of a receiver structure or no additional information transmission. The approach we employed is to apply the peak windowing scheme to the amplitude modulated signals of the polar transmitter to reduce the PAPR (Peak-to-Average Power Ratio). The BER (Bit Error Rate) and EVM (Error Vector Magnitude) performances are measured for various window types and lengths. The simulation results demonstrate that the proposed algorithm mitigates out-of-band distortion introduced by clipping along with PAPR reduction.

Uncertainty analysis of quantitative rainfall estimation based on weather radars (기상레이더 기반 정량적 강수추정에서의 불확실성 분석)

  • Lee, Jae-Kyoung
    • Proceedings of the Korea Water Resources Association Conference
    • /
    • 2017.05a
    • /
    • pp.23-23
    • /
    • 2017
  • 기상레이더는 강우량을 바로 추정하지 못하는 특성으로 인해 정량적 강우산출 과정 중에 다양한 원인으로 인해 불확실성 발생 요소가 존재하나 이를 정량화하고 저감하는데 많은 어려움이 있다. 원인을 살펴보면, 첫째, 기상레이더의 관측에서부터 정량적 강우량 추정까지 일련의 과정에 대한 포괄적으로 불확실성 정량화와 분석이 이루어지지 못하며, 둘째, 전체 불확실성이 어느 정도 되는지 제시하지 못하므로 각 단계별 불확실성이 전체 불확실성 대비 어느 정도 비율이 되는지 제시하지 못한다. 마지막으로 기존 연구들은 불확실성을 줄이고자 여러 방법을 사용하고 있으나 어느 정도 효용성이 있는지 불확실성 측면에서 제시하지 못하고 있다. 따라서 본 연구에서는 Maximum Entropy(ME)와 Uncertainty Delta Method(UMD)를 이용한 접근방법을 제안하여 기상레이더를 활용하여 정량적 강우량을 추정하는 일련의 과정에서 단계별로 불확실성이 어떻게 전파되는지 추정하였다. 본 연구에서는 한반도 전역을 대상으로 2012년 여름철(6~8월)에 발생한 18개 강우사례를 이용하여 품질관리(Open Radar Product Generator 품질관리 알고리즘, fuzzy 알고리즘), 강우추정(Window Probability Matching Method, Marshall-Palmer 관계식), 후처리보정(Local Gauge Correction 기법, Gauge to Radar ratio 기법)단계만을 수행하였으며, 이 결과를 바탕으로 기상레이더 정량적 강우추정 단계별 불확실성을 정량화하였다. 정량화결과, 최종적으로 관측단계의 불확실성보다 최종 불확실성이 줄어들었으나, 강우추정 단계에서 불확실성이 증가하는 것으로 나타났다. 이는 어떤 강우추정식을 적용하느냐에 따라 레이더 강우추정결과가 매우 달라질 수 있음을 의미한다. 따라서 본 연구에서 제시한 불확실성 정량화 방법을 통하여 첫째, 전체 및 단계별 불확실성을 정량화할 수 있고, 둘째, 최종 불확실성 대비 각 단계별 불확실성을 비율을 제시할 수 있으며, 마지막으로 수행단계별로 불확실성 전파과정을 파악할 수 있다. 이는 향후 정량적 레이더 강우추정 과정에 있어서 불확실성을 발생시키는 주요 원인파악과 이에 대한 집중적인 투자를 가능하게 한다. 이러한 과정을 통하여 보다 정확한 정량적 레이더 강우추정이 가능할 것으로 판단된다.

  • PDF

A Scene Boundary Detection Scheme using Audio Information in MPEG System Stream (MPEG 시스템 스트림상에서 오디오 정보를 이용한 장면 경계 검출 방법)

  • Kim, Jae-Hong;Nang, Jong-Ho;Park, Soo-Yong
    • Journal of KIISE:Software and Applications
    • /
    • v.27 no.8
    • /
    • pp.864-876
    • /
    • 2000
  • This paper proposes a new scene boundary detection scheme for the MPEG System stream using MPEG Audio information and proves its usefulness by extensive experiments. A scene boundary has a characteristic that the audio as well as video information are changed rapidly. This paper first classifies this scene boundary into three cases ; Radical, Gradual, Micro Changes, with respect to the audio changes. The Radical change has a large-scale changing of decibel value and pitch value at a scene boundary, the Gradual change shows the long-time transition of decibel and pitch values from max to min or vice versa, and the Micro change displays a some change of pitch or frequency distribution without decibel changes. Upon this analysis, a new scene change detection algorithm detecting these three cases is proposed in which a progressive window with a time line is used to trace the changes in the audio information. Some experiments with various movies show that proposed algorithm could produce a high detection ratio for Radical change that is the most popular scene change in the movies, while producing a moderate detection ratio for Gradual and Micro changes. The proposed scene boundary detection scheme could be used to build a database for visual information like MPEG System stream.

  • PDF

A Signal Detection Technique for OFDMA-based Wireless Mesh Networks with Different Time Delays (서로 다른 지연 시간을 갖는 OFDMA 기반의 Wireless Mesh Networks를 위한 신호 검출 기법)

  • Park, Chang-Hwan;Yoo, Hyun-Il;Kim, Yeong-Jun;Kwon, Dong-Seung;Cho, Yong-Soo
    • The Journal of Korean Institute of Communications and Information Sciences
    • /
    • v.35 no.6C
    • /
    • pp.495-505
    • /
    • 2010
  • In this paper, the effect of Near-Far Problem (NFP) among distributed nodes in OFDMA-based Wireless Mesh Networks (WMNs) is analyzed by investigating statistical characteristics of Time Difference of Arrival (TDoA) and Desired-to-Undesired power Ratio (DUR). In order to overcome the effects of Inter-Symbol Interference (ISI), Inter-Carrier Interference (ICI), and Inter Link Interference (ILI), caused by TDoA in WMNs, we derive effective SINR for each subcarrier, and then, propose the optimal starting point of FFT window which can minimize BER for each subcarrier. In addition, we propose a subcarrier-based Zero Forcing - 2 Dimensional Ordered Successive Interference Cancellation (ZF-2DOSIC) technique for signal detection in WMNs with TDoA. It is verified by simulation that the effective SINR and uncoded BER performances of the proposed signal detection technique for OFDMA-based WMNs are significantly improved, compared with those of conventional technique.

Performance Characteristics of 3D GSO PET/CT Scanner (Philips GEMINI PET/DT) (3차원 GSO PET/CT 스캐너(Philips GEMINI PET/CT의 특성 평가)

  • Kim, Jin-Su;Lee, Jae-Sung;Lee, Byeong-Il;Lee, Dong-Soo;Chung, June-Key;Lee, Myung-Chul
    • The Korean Journal of Nuclear Medicine
    • /
    • v.38 no.4
    • /
    • pp.318-324
    • /
    • 2004
  • Purpose: Philips GEMINI is a newly introduced whole-body GSO PET/CT scanner. In this study, performance of the scanner including spatial resolution, sensitivity, scatter fraction, noise equivalent count ratio (NECR) was measured utilizing NEMA NU2-2001 standard protocol and compared with performance of LSO, BGO crystal scanner. Methods: GEMINI is composed of the Philips ALLEGRO PET and MX8000 D multi-slice CT scanners. The PET scanner has 28 detector segments which have an array of 29 by 22 GSO crystals ($4{\times}6{\times}20$ mm), covering axial FOV of 18 cm. PET data to measure spatial resolution, sensitivity, scatter fraction, and NECR were acquired in 3D mode according to the NEMA NU2 protocols (coincidence window: 8 ns, energy window: $409[\sim}664$ keV). For the measurement of spatial resolution, images were reconstructed with FBP using ramp filter and an iterative reconstruction algorithm, 3D RAMLA. Data for sensitivity measurement were acquired using NEMA sensitivity phantom filled with F-18 solution and surrounded by $1{\sim}5$ aluminum sleeves after we confirmed that dead time loss did not exceed 1%. To measure NECR and scatter fraction, 1110 MBq of F-18 solution was injected into a NEMA scatter phantom with a length of 70 cm and dynamic scan with 20-min frame duration was acquired for 7 half-lives. Oblique sinograms were collapsed into transaxial slices using single slice rebinning method, and true to background (scatter+random) ratio for each slice and frame was estimated. Scatter fraction was determined by averaging the true to background ratio of last 3 frames in which the dead time loss was below 1%. Results: Transverse and axial resolutions at 1cm radius were (1) 5.3 and 6.5 mm (FBP), (2) 5.1 and 5.9 mm (3D RAMLA). Transverse radial, transverse tangential, and axial resolution at 10 cm were (1) 5.7, 5.7, and 7.0 mm (FBP), (2) 5.4, 5.4, and 6.4 mm (3D RAMLA). Attenuation free values of sensitivity were 3,620 counts/sec/MBq at the center of transaxial FOV and 4,324 counts/sec/MBq at 10 cm offset from the center. Scatter fraction was 40.6%, and peak true count rate and NECR were 88.9 kcps @ 12.9 kBq/mL and 34.3 kcps @ 8.84 kBq/mL. These characteristics are better than that of ECAT EXACT PET scanner with BGO crystal. Conclusion: The results of this field test demonstrate high resolution, sensitivity and count rate performance of the 3D PET/CT scanner with GSO crystal. The data provided here will be useful for the comparative study with other 3D PET/CT scanners using BGO or LSO crystals.

Feasibility of Pediatric Low-Dose Facial CT Reconstructed with Filtered Back Projection Using Adequate Kernels (필터보정역투영과 적절한 커널을 이용한 소아 저선량 안면 컴퓨터단층촬영의 시행 가능성)

  • Hye Ji;Sun Kyoung You;Jeong Eun Lee;So Mi Lee;Hyun-Hae Cho;Joon Young Ohm
    • Journal of the Korean Society of Radiology
    • /
    • v.83 no.3
    • /
    • pp.669-679
    • /
    • 2022
  • Purpose To evaluate the feasibility of pediatric low-dose facial CT reconstructed with filtered back projection (FBP) using adequate kernels. Materials and Methods We retrospectively reviewed the clinical and imaging data of children aged < 10 years who underwent facial CT at our emergency department. The patients were divided into two groups: low-dose CT (LDCT; Group A, n = 73) with a fixed 80-kVp tube potential and automatic tube current modulation (ATCM) and standard-dose CT (SDCT; Group B, n = 40) with a fixed 120-kVp tube potential and ATCM. All images were reconstructed with FBP using bone and soft tissue kernels in Group A and only bone kernel in Group B. The groups were compared in terms of image noise, signal-to-noise ratio (SNR), and contrast-to-noise ratio (CNR). Two radiologists subjectively scored the overall image quality of bony and soft tissue structures. The CT dose index volume and dose-length product were recorded. Results Image noise was higher in Group A than in Group B in bone kernel images (p < 0.001). Group A using a soft tissue kernel showed the highest SNR and CNR for all soft tissue structures (all p < 0.001). In the qualitative analysis of bony structures, Group A scores were found to be similar to or higher than Group B scores on comparing bone kernel images. In the qualitative analysis of soft tissue structures, there was no significant difference between Group A using a soft tissue kernel and Group B using a bone kernel with a soft tissue window setting (p > 0.05). Group A showed a 76.9% reduction in radiation dose compared to Group B (3.2 ± 0.2 mGy vs. 13.9 ± 1.5 mGy; p < 0.001). Conclusion The addition of a soft tissue kernel image to conventional CT reconstructed with FBP enables the use of pediatric low-dose facial CT protocol while maintaining image quality.

The Influence Evaluation of $^{201}Tl$ Myocardial Perfusion SPECT Image According to the Elapsed Time Difference after the Whole Body Bone Scan (전신 뼈 스캔 후 경과 시간 차이에 따른 $^{201}Tl$ 심근관류 SPECT 영상의 영향 평가)

  • Kim, Dong-Seok;Yoo, Hee-Jae;Ryu, Jae-Kwang;Yoo, Jae-Sook
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • v.14 no.1
    • /
    • pp.67-72
    • /
    • 2010
  • Purpose: In Asan Medical Center we perform myocardial perfusion SPECT to evaluate cardiac event risk level for non-cardiac surgery patients. In case of patients with cancer, we check tumor metastasis using whole body bone scan and whole body PET scan and then perform myocardial perfusion SPECT to reduce unnecessary exam. In case of short term in patients, we perform $^{201}Tl$ myocardial perfusion SPECT after whole body bone scan a minimum 16 hours in order to reduce hospitalization period but it is still the actual condition in which the evaluation about the affect of the crosstalk contamination due to the each other dissimilar isotope administration doesn't properly realize. So in our experiments, we try to evaluate crosstalk contamination influence on $^{201}Tl$ myocardial perfusion SPECT using anthropomorphic torso phantom and patient's data. Materials and Methods: From 2009 August to September, we analyzed 87 patients with $^{201}Tl$ myocardial perfusion SPECT. According to $^{201}Tl$ myocardial perfusion SPECT yesterday whole body bone scan possibility of carrying out, a patient was classified. The image data are obtained by using the dual energy window in $^{201}Tl$ myocardial perfusion SPECT. We analyzed $^{201}Tl$ and $^{99m}Tc$ counts ratio in each patients groups obtained image data. We utilized anthropomorphic torso phantom in our experiment and administrated $^{201}Tl$ 14.8 MBq (0.4 mCi) at myocardium and $^{99m}Tc$ 44.4 MBq (1.2 mCi) at extracardiac region. We obtained image by $^{201}Tl$ myocardial perfusion SPECT without gate method application and analyzed spatial resolution using Xeleris ver 2.0551. Results: In case of $^{201}Tl$ window and the counts rate comparison result yesterday whole body bone scan of being counted in $^{99m}Tc$ window, the difference in which a rate to 24 hours exponential-functionally notes in 1:0.114 with Ventri (GE Healthcare, Wisconsin, USA), 1:0.249 after the bone tracer injection in 12 hours in 1:0.411 with 1:0.79 with Infinia (GE healthcare, Wisconsin, USA) according to a reduction a time-out was shown (Ventri p=0.001, Infinia p=0.001). Moreover, the rate of the case in which it doesn't perform the whole body bone scan showed up as the average 1:$0.067{\pm}0.6$ of Ventri, and 1:$0.063{\pm}0.7$ of Infinia. According to the phantom after experiment spatial resolution measurement result, and an addition or no and time-out of $^{99m}Tc$ administrated, it doesn't note any change of FWHM (p=0.134). Conclusion: Through the experiments using anthropomorphic torso phantom and patients data, we found that $^{201}Tl$ myocardium perfusion SPECT image later carried out after the bone tracer injection with 16 hours this confirmed that it doesn't receive notable influence in spatial resolution by $^{99m}Tc$. But this investigation is only aimed to image quality, so it needs more investigation in patient's radiation dose and exam accuracy and precision. The exact guideline presentation about the exam interval should be made of the validation test which is exact and in which it is standardized about the affect of the crosstalk contamination according to the isotope use in which it is different later on.

  • PDF

A Comparative Study on the Spatial Sense of Interior and Exterior Spaces (실내와 실외의 공간감 비교 연구)

  • Yoo, Mi-Kyoung;Im, Seung-Bin
    • Journal of the Korean Institute of Landscape Architecture
    • /
    • v.40 no.5
    • /
    • pp.63-72
    • /
    • 2012
  • In contemporary times, "environmental designers" need to consider both exterior and interior aspects because of the growing trend in dissolution between exterior and interior spaces. To quantify "spatial sense" which serves as the standard for environmental design, this study has asked 63 subjects to evaluate 15 interior and 14 exterior spaces. The "spaciousness (small-large)", "openness(closed-open)", "warmness(warm-cold)", "brightness(bright-dark)", "softness(soft-hard)", "spatial intimacy" and "frequency of visit" were adopted as variables of spatial sense. Through the analysis of these variables, this study could gain the difference between spatial sense for exterior and interior environments, quantify the spatial sense that physically and psychologically appropriates to human beings. The result of this study can be summarized as follows: Twice the amount of spaciousness was observed between the interior and exterior spaces. And the standard on intimate space is established with W/H ratio of 5.71 and high Window/Wall Area ratio in the interior and an area of 3,800m2 and a W/H ratio of 5.57 in exterior. The difference between the spatial sense in the interior and exterior space is mostly dependent on the psychological sense. The increase of physical size caused by the interior space to be perceived as cold, dark and hard psychologically, but exterior space to be perceived as warm, bright and soft. Psychological senses, especially softness, affect spatial intimacy to the greatest extent among the given variables. As the psychological senses for interior spaces were largely independent from the given space's size and perceptive senses, the size of the interior space, which exhibited spatial intimacy, could not be deduced. In comparison to this, due to the high dependency between the psychological senses for exterior spaces and the given space's size and perceptive senses. The study also showed that interior and exterior spaces have relatively different spatial sense and physical standards. Such research results are predicted to provide applicable standards for environmental designers for exterior and interior spaces in the future.

The Influence of the Regional Weather in Geriatric Trauma (지역기상이 노인외상에 미치는 영향)

  • Kim, Jung Ho;Do, Byung Soo;Lee, Sam Beom;Lee, Sung Hoon;Si, Jong Won;Lee, Jae Young;Kim, Oh Lyong
    • Journal of Trauma and Injury
    • /
    • v.19 no.2
    • /
    • pp.97-104
    • /
    • 2006
  • Purpose: Many factors influence the occurrence and severity of geriatric trauma, and regional weather is regarded as one factor that influences geriatric trauma. In this study, to predict the type, severity, and incidence of geriatric trauma patient, we analyzed the influence of regional weather on geriatric trauma. Methods: The subjects of our investigation were trauma patients over sixty-five years of age who visited the Emergency Department (ED) of Yeungnam University Hospital during a one-year period. We retrospectively reviewed the medical charts of 436 geriatric trauma patients, and the data were analyzed by using SPSS 12.0 for Window. The weather was based on data from the Korea Meteorological Administration. Results: The average age was 72.8 years old, and the ratio of males to females was 1:1.1. The mean spell out ISS was 10.8, and no difference was found between males and females. Slips were the most common cause of trauma. The largest numbers of aged trauma patients, 46, visited the ED in May, and the smallest number of such patients, 24, visited the ED in December. In addition to, summer saw the largest number of aged trauma patients. The type of trauma, the Injury Severity Score, and the number of patients had no relationship with season. On sunny days, the ISS was larger in patients who had hypotension and who had tachycardia. On rainy day, the ISS was larger in male patients and cultivator accident patients. The number of patients was larger on partly cloudy days. Conclusion: In spring and summer and on partly cloudy days, we must be prepared to treat aged traumatized patients in the E.D. On rainy days, visual sensation, tactual sense, and acoustic sense must be closely examined. In addition,on rainy day, aged male traumatized patients or cultivator accident patients must to be closely observation.

Improvement of Quantity Take-Off and BoQ through the LOD Criteria Analysis of BIM Models (BIM 모델 표현 수준(LOD) 분석을 통한 내역체계 개선방안 연구)

  • Choi, Hyunjun;Yun, Seokheon
    • Korean Journal of Construction Engineering and Management
    • /
    • v.20 no.6
    • /
    • pp.89-97
    • /
    • 2019
  • Recently, BIM has been actively introduced in construction projects. In particular, the introduction of BIM in cost estimating process is expected to improve the accuracy and efficiency of the cost estimate. However, the quantity calculation and BoQ documents preparation process still require manual work. Although the BIM model may support quantification process, it is still problematic that the level of detail of the model must be very detailed to meet the items in BoQ. To address this, it is necessary to analyse the LOD criteria and to analyze the extent to which quantity can be computed according to the level of detail in the BIM model. For the analysis of LOD-based work items, the work item grades were divided into A,B, and C. In this study, the ratio and cost of each item that can be calculated at the LOD level in the detailed design phase are reviewed for each type of work, and the method for improving the quantity calculation using BIM is proposed. In the LOD 300 stage(Detailed design stage), the largest number of items in the class B, the major improvement class, are window and glass work. In addition, the most expensive type of work was analyzed by reinforced concrete work. In the future, it is necessary to suggest appropriate improvement way for items with high item ratios and items with high cost ratios. The results of this study are expected to be used as a BIM-based cost estimation or as basic data for improving the current BoQ system.