• Title/Summary/Keyword: Ratio correction factor

Search Result 189, Processing Time 0.025 seconds

A Study on the Risk of Pesticide Exposure by Food Intake (식이섭취를 통한 농약폭로의 위해도에 관한 연구)

  • 전옥경;이용욱
    • Journal of Food Hygiene and Safety
    • /
    • v.14 no.2
    • /
    • pp.201-215
    • /
    • 1999
  • Limited information is available on the acceptability of Korean MRLs(maximum residue limits) and the health risk based on the pesticide exposure by food intake. The aim of this study was to evaluate TMDI(theoretical maximum daily intake) and EDI(estimated daily intake) for Korean by using MRLs, food intake, residue data, and correction factors, and compare with ADI(acceptable daily intake) in order to estimate the health risk based on the pesticide exposure. The study was performed in three steps. In the frist step, the residual pesticides in each category of food were investigated using the pesticide residue analytical data(1995-96) from officially approved organizations and the analytical data for poultry was adopted from Korean food code method. In the second step, TMDI was estimated from MRLs and food factors, and was compared with ADI. In the third step, the effectiveness of each culinary treatment (washing, peeling, steaming, boiling, and salting) was evaluated and EDI was calculated using pesticide residue data, food factor, and correction factor by treatment. TMDI obtained from MRLs and food intake, and food intake was summed as 1,100.99 g, which was 79.1% of total consumption. The percent ratio of TMDI to ADI for 156 pesticides was mostly below 80% and only 30 pesticides exceeded the ADI. In particular, non-treated EDI from pesticide residue data and food intake was summed up to about 43 $\mu\textrm{g}$/day/capita, and the rank was procymidone(8.6 $\mu\textrm{g}$) > maleic hydrazide(8.2 $\mu\textrm{g}$) > EPN(3.7 $\mu\textrm{g}$) > deltamethrin(3.5 $\mu\textrm{g}$) > cypermethrin(3.0 $\mu\textrm{g}$). The treated EDI calculated from pesticide residue data, food intake, and correction factor by culinary treatment was summed up to 13.7 $\mu\textrm{g}$/day/captia. The percentage of ADI was TMDI(79.74%) > non-treated EDI (0.17%) > treated EDI (0.04%), and the exposure level of Korean population to whole pesticides was below the level to produce health risk. Oncogenic risk of five pesticides used in Korea whose oncogenic potency(Q*) was known were assessed from TMDI and treated EDI. Dietary oncogenic risk for Korean was estimated to be 2.0$\times$10-3 on the basis of TMDI, 8.3$\times$10-7 on the basis of treated EDI. The oncogenic risk from TMDI exceeded the risk level(1$\times$10-6) of EPA, whereas the oncogenic risk from treated EDI and real exposure level lower than that of EPA.

  • PDF

The Study on Dose Calculations for Blocked Fields (차폐 조사면에서 선량계산에 관한 연구)

  • 정동혁;김진기;오영기;신교철;김기환;김정기;문성록;김정수;박인규
    • Progress in Medical Physics
    • /
    • v.12 no.2
    • /
    • pp.133-140
    • /
    • 2001
  • The dose calculations for blocked fields were studied. The shielding block correction factors(K$_{b}$) as a function of collimator and blocked field size(r$_{c}$ and r$_{b}$) were measured. A simplified $K_{b}$ as a function of $A_{r}$ (the A/P ratio of r$_{b}$ to r$_{c}$) was determined by measured data and a fitting function for $K_{b}$ was obtained. We found that the corrections of $K_{b}$ for blocked fields in MU(monitor units) calculations need not take into account in common case of $A_{r}$ \ulcorner1 but the errors will be 3.5% in particular case such as $A_{r}$ = 0.5. These results imply that the shielding block correction for blocked fields in clinical dose calculations must be considered.

  • PDF

A Study on Heat Transfer Coefficient of a Perfluorocarbon Heat Pipe (Perfluorocarbon 히트파이프의 열전달 계수에 관한 연구)

  • 강환국;김철주;김재진
    • Journal of Energy Engineering
    • /
    • v.7 no.2
    • /
    • pp.194-201
    • /
    • 1998
  • In electric commuter trains using AC motors, lots of GTO thyristors and diodes are needed for power controls. These semiconductors generate heat about 1~2 kW, and for cooling which perfluorocarbon(PFC) heat pipes have been in use for the last two decades. The present study was investigated on the effects of such important design parameters as structure of internal surface (grooved or smooth), fill charge ratio, and inclinating angle from a vertical on heat transfer coefficients at both evaporators and condensers. To obtain experimental data, several heat pipes of the same geometry of 520 mm long and diameter of 15.88 mm but different in fill charge ratio and internal surface structure were designed and fabricated. For prediction of the heat transfer coefficients, related expressions were examined and the results of calculations were compared with experimental data. Performance tests were conducted while heat pipes operated at mode of thermosyphons. High enhancements of heat transfer coefficient were obtained internal grooves. In these cases, the evaporating heat transfer coefficients distributed in the range of 2~5.5 kW/$m^2$K, with an increase of heat flux from 15~45 kW/$m^2$. These experimental data were in good agreement with Rohsenow's expression based on nucleate boiling when correction factor $C_R$=1.3 was encountered. In addition, the condensation heat transfer coefficients were distributed from 1.5 to 3.5 kW/$m^2$K, and the data were in good agreements with Nusselt's correlation, based on filmwise condensation on vertical plate, when choosing a correction factor $C_N=4$. A fill charge ratio of 40~100% were recommended, and the in clination angle effects were negligible when the angle was higher then 30$^{\circ}$.

  • PDF

Calculations of Radiation Measurement-Related Correction Factors (방사선 측정관련 보정인자 계산)

  • Shin, Hee-Sung;Ro, Seung-Gy;Kim, Ho-Dong
    • Journal of Radiation Protection and Research
    • /
    • v.28 no.1
    • /
    • pp.19-24
    • /
    • 2003
  • The self-attenuation factor for an $^{198}Au$ sample and the 0.412 MeV gamma-ray penetration ratio in the circular Al-cover of the radiation detector have been determined using an analytical solution and MCNP code. The results show that the self-attenuation factors obtained from the analytical solution coincide with those of MCNP code for all but the Au sample with the relatively larger radius. Then the maximum difference between the two methods appears to be 9 % in the Au sample of 1.5 mm radius. It also is revealed that the analytical solutions of the 0.412 MeV gamma-ray penetration ratio in the Al-cover of 7.62 cm radius are consistent with those of the MCNP code within the standard deviation.

Empirical Estimation and Diurnal Patterns of Surface PM2.5 Concentration in Seoul Using GOCI AOD (GOCI AOD를 이용한 서울 지역 지상 PM2.5 농도의 경험적 추정 및 일 변동성 분석)

  • Kim, Sang-Min;Yoon, Jongmin;Moon, Kyung-Jung;Kim, Deok-Rae;Koo, Ja-Ho;Choi, Myungje;Kim, Kwang Nyun;Lee, Yun Gon
    • Korean Journal of Remote Sensing
    • /
    • v.34 no.3
    • /
    • pp.451-463
    • /
    • 2018
  • The empirical/statistical models to estimate the ground Particulate Matter ($PM_{2.5}$) concentration from Geostationary Ocean Color Imager (GOCI) Aerosol Optical Depth (AOD) product were developed and analyzed for the period of 2015 in Seoul, South Korea. In the model construction of AOD-$PM_{2.5}$, two vertical correction methods using the planetary boundary layer height and the vertical ratio of aerosol, and humidity correction method using the hygroscopic growth factor were applied to respective models. The vertical correction for AOD and humidity correction for $PM_{2.5}$ concentration played an important role in improving accuracy of overall estimation. The multiple linear regression (MLR) models with additional meteorological factors (wind speed, visibility, and air temperature) affecting AOD and $PM_{2.5}$ relationships were constructed for the whole year and each season. As a result, determination coefficients of MLR models were significantly increased, compared to those of empirical models. In this study, we analyzed the seasonal, monthly and diurnal characteristics of AOD-$PM_{2.5}$model. when the MLR model is seasonally constructed, underestimation tendency in high $PM_{2.5}$ cases for the whole year were improved. The monthly and diurnal patterns of observed $PM_{2.5}$ and estimated $PM_{2.5}$ were similar. The results of this study, which estimates surface $PM_{2.5}$ concentration using geostationary satellite AOD, are expected to be applicable to the future GK-2A and GK-2B.

A Study on Calculation of Protection Ratio for Interference Analysis in Fixed Radio Relay Networks (고정 무선중계 망의 간섭 분석을 위한 보호비 계산에 대한 연구)

  • Suh Kyoung-Whoan;Lee Joohwan
    • Journal of the Institute of Electronics Engineers of Korea TC
    • /
    • v.43 no.1 s.343
    • /
    • pp.133-142
    • /
    • 2006
  • This paper suggests an efficient method of protection ratio(PR) calculation and shows some results of point-to-point radio relay system for frequency coordination. The proposed PR can be expressed as a function of C/N of modulation scheme, noise-to-interference ratio(N/I), multiple interference allowance, fade margins of multi-Path and rain attenuation and net filter discrimination. And PR calculation is performed in view of fade margin, modulation scheme, distance, and interference for actual point-to-point radio relay frequency. According to results for 6.2 GHz, 64-QAM and 60 km at BER 10-6, fade margin and co-channel Protection ratio reveal 41.1dB and 74.9 dB, respectively The merit of presented method provides a systematic and easy calculation by means of PR correction factor related with various parameters and can apply the same concept to frequency coordination of millimeter wave radio relay system.

Bending Analysis of Symmetrically Laminated Composite Open Section Beam Using the First-Order Shear Deformation Beam Theory (Timoshenko형 전단변형을 고려한 대칭적층 개단면 복합재 보의 휨해석)

  • 권효찬;박영석;신동구
    • Proceedings of the Computational Structural Engineering Institute Conference
    • /
    • 2000.04b
    • /
    • pp.43-50
    • /
    • 2000
  • In the first-order shear deformation laminated beam theory (FSDT), the Kirchhoff hypothesis is relaxed such that the transverse normals do not remain perpendicular to the midsurface after deformation. Bending behavior of laminated composite thin-walled beams with singly- and doubly-symmetric open sections under uniformly distributed and concentrated loads is analyzed by the Timoshenko-type thin-walled beam theory. A closed-form expression for the shear correction factor of I-shaped composite laminated section is obtained. Numerical examples are presented to compare present analytical solutions by FSDT with the finite element solutions obtained by using three dimensional model. The effects of lamination of scheme and length-to-height ratio on the shear deformation of laminated composite beams with various boundary conditions are studied.

  • PDF

Study on the Asymmetrical Fault Currents and the Operating Time Characteristics of OCR (비대칭과도 전류와 과전류계전기의 동작시간 특성에 관한 연구)

  • 김남호;김일남;박종근
    • The Transactions of the Korean Institute of Electrical Engineers
    • /
    • v.41 no.9
    • /
    • pp.953-959
    • /
    • 1992
  • As the TC(time-current) curve corresponding to symmetrical time invariant RMS value has been traditionally chosen and used for setting the relay, it has caused the misoperation errors on relay coordination because of CT secondary current being actually an asymmetrical time varying RMS value. In this paper, an algorithm for calculating the relay operating time is developed to study the asymmetrical effect using the step-by-step method. We represent the relay operating time errors between with and without DC offset versus PSM(plug setting multiplier), TMS(time multiplier setting) and X/R ratio. And also we present the correction factor. Finally we confirm the validity of this technique through the case study.

A New Frequency Controlled Half-bridge Converter with Hold-up Time Extension Circuit

  • Kim, Duk-You;Kim, Jae-Kuk;Lee, Woo-Jin;Moon, Gun-Woo
    • Proceedings of the KIPE Conference
    • /
    • 2008.06a
    • /
    • pp.382-384
    • /
    • 2008
  • Hold-up time is a special requirement for the front end DC/DC converter in a server power supply. It forces the converter with the variable switching frequency to operate in a wide switching frequency range, which makes the regulation difficult and reduces the power density. In this paper a novel frequency controlled half bridge converter with the hold-up time extension circuit is proposed. During the hold-up time, the auxiliary switches are turned on, thus the resonant inductance is reduced and the voltage conversion ratio is increased. Therefore, the output capacitor of the power factor correction (PFC) circuit can be decreased, and the converter can have high power density. The proposed converter is verified by experimental results from a prototype with 700W, 400V input, and 12V output.

  • PDF

Analysis of functionally graded plates using a sinusoidal shear deformation theory

  • Hadji, Lazreg
    • Smart Structures and Systems
    • /
    • v.19 no.4
    • /
    • pp.441-448
    • /
    • 2017
  • This paper uses the four-variable refined plate theory for the free vibration analysis of functionally graded material (FGM) rectangular plates. The plate properties are assumed to be varied through the thickness following a simple power law distribution in terms of volume fraction of material constituents. The theory presented is variationally consistent, does not require shear correction factor, and gives rise to transverse shear stress variation such that the transverse shear stresses vary parabolically across the thickness satisfying shear stress free surface conditions. Equations of motion are derived from the Hamilton's principle. The closed-form solutions of functionally graded plates are obtained using Navier solution. Numerical results of the refined plate theory are presented to show the effect of the material distribution, the aspect and side-to-thickness ratio on the fundamental frequencies. It can be concluded that the proposed theory is accurate and simple in solving the free vibration behavior of functionally graded plates.