• 제목/요약/키워드: Ratio Correction Factor

검색결과 189건 처리시간 0.023초

A Study on Design Factor of Insole using Shape Memory Alloy for Pes Planus Correction (평발교정용 형상기억합금 초탄성 인솔 설계 연구)

  • Yang, Mi Kyung;Lee, Sang-Wook
    • Journal of the Korea Academia-Industrial cooperation Society
    • /
    • 제18권5호
    • /
    • pp.79-85
    • /
    • 2017
  • As the number of patients suffering from Pes Planus increases, research on a correctional insole that can cope with them is increasingly required. Therefore, the design of an insole for Pes Planus Correction was studied using the superelastic effect, which is one of the characteristics of the shape memory alloy in this paper. To design an effective insole, the effect of the contact pressure induced by the insole on the plantar fascia, which is the most important muscle in the foot structure, was evaluated. Three parameters (thickness, max. height and asymmetric ratio) were set as the main design factors of the insole, and the maximum contact pressure appearing on the plantar fascia was calculated by finite element analysis and analyzed using the Taguchi method. As a result of the analysis, it was confirmed that the contact pressure was influenced in the order of max. height, thickness, and asymmetric ratio. In addition, the contact pressure was converted to a feeling pressure that could be felt by a person, and then a safety correction range was established that would not cause any irritation to the plantar fascias, even though the correction effect could be expected. This indicates the best design for the safety correction range. The design method considering the important factors established through this study can form the basis for designing a personalized correctional insole in the future.

Effect of the Signal-to-Noise Power Spectra Ratio On MTF compensated EOC images

  • Kang, Chi-Ho;Choi, Hae-Jin
    • Proceedings of the KSRS Conference
    • /
    • 대한원격탐사학회 2002년도 Proceedings of International Symposium on Remote Sensing
    • /
    • pp.202-207
    • /
    • 2002
  • EOC (Electro-Optical Camera) of KOMPSAT-1 (Korea Multi-Purpose SATellite) has been producing land imageries of the world since January 2000. After image data are acquired by EOC, they are transmitted from satellite to ground via X-band RF signal. Then, EOC image data are generated and pass through radiometric and geometric corrections to generate standard products of EOC images. After radiometric correction on EOC image data, Modulation Transfer Function (MTF) compensation is applicable on EOC images with user's request for better image quality. MTF compensation is concerned with filtering EOC images to minimize the effect of degradations. For Image Receiving and Processing System (IRPE) at KOMPSAT Ground Station (KGS), Wiener filter is used in MTF compensation for EOC images. If the Pointing Spread Function (PSF) of EOC system is known, signal-to-noise power spectra ratio is the only factor in the determination of Wiener filter. In this paper, MTF compensation in IRPE at KGS is introduced and MTF compensated EOC 1R images are generated using Wiener filters with various signal-to-noise power spectra ratios. MTF compensated EOC 1R images are correlated with EOC 1R images for observing linearities between them. As a result, the effect of signal-to-noise power spectra ratio is shown on MTF compensated EOC 1R images.

  • PDF

A Bayesian Test for First Order Autocorrelation in Regression Errors : An Application to SPC Approach (회귀모형 오차항의 1차 자기상관에 대한 베이즈 검정법 : SPC 분야에의 응용)

  • Kim, Hea-Jung;Han, Sung-Sil
    • Journal of Korean Society for Quality Management
    • /
    • 제24권4호
    • /
    • pp.190-206
    • /
    • 1996
  • In case measurements are made on units of production in time order, it is reasonable to expect that the measurement errors will sometimes be first order autocorrelated, and a technique to test such autocorrelation is required to give good control of the productive process. Tool-wear process provide an example for which regression model can sometimes be useful in modeling and controlling the process. For the control of such process, we present a simple method for testing first order autocorrelation in regression errors. The method is based on Bayesian test method via Bayes factor and derived by observing that in general, a Bayes factor can be written as the product of a quantity called the Savage-Dickey density ratio and a correction factor ; both terms are easily estimated from Gibbs sampling technique. Performance of the method is examined by means of Monte Carlo simulation. It is noted that the test not only achieves satisfactory power but eliminates the inconvenience occurred in using the well-known Durbin-Watson test.

  • PDF

A color compensation method for a projector considering non-flatness of color screen and mean lightness of the projected image (유색 스크린의 굴곡과 영상의 평균밝기를 고려한 프로젝터용 색 보정 기법)

  • Sung, Soo-Jin;Lee, Cheol-Hee
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • 제14권1호
    • /
    • pp.213-224
    • /
    • 2010
  • In this paper, we propose an algorithm both geometric correction using a grid point image and radiometric adaptive projection that dependent upon the luminance of the input image and that of the background. This method projects and captures the grid point image then calculates the geometrically corrected position by difference between the two images. Next, to compensate color, a corrected image is calculated by the ratio divided luminance of an input image by luminance of arbitrary surface. In addition, we found the scaling factor which controls the contrast to avoid clipping error. At this time, the scaling factor is dependent on mean image lightness when background is determined. Experimental results show that the proposed method achieves good performance and is able to reduce the perceived color clipping and artifacts, better approximating the projection on a white screen.

Orthogonal variable spreading factor encoded unmanned aerial vehicle-assisted nonorthogonal multiple access system with hybrid physical layer security

  • Omor Faruk;Joarder Jafor Sadiqu;Kanapathippillai Cumanan;Shaikh Enayet Ullah
    • ETRI Journal
    • /
    • 제45권2호
    • /
    • pp.213-225
    • /
    • 2023
  • Physical layer security (PLS) can improve the security of both terrestrial and nonterrestrial wireless communication networks. This study proposes a simplified framework for nonterrestrial cyclic prefixed orthogonal variable spreading factor (OVSF)-encoded multiple-input and multiple-output nonorthogonal multiple access (NOMA) systems to ensure complete network security. Various useful methods are implemented, where both improved sine map and multiple parameter-weighted-type fractional Fourier transform encryption schemes are combined to investigate the effects of hybrid PLS. In addition, OVSF coding with power domain NOMA for multi-user interference reduction and peak-toaverage power ratio (PAPR) reduction is introduced. The performance of $\frac{1}{2}$-rated convolutional, turbo, and repeat and accumulate channel coding with regularized zero-forcing signal detection for forward error correction and improved bit error rate (BER) are also investigated. Simulation results ratify the pertinence of the proposed system in terms of PLS and BER performance improvement with reasonable PAPR.

The Correction Factor of Sensitivity in Gamma Camera - Based on Whole Body Bone Scan Image - (감마카메라의 Sensitivity 보정 Factor에 관한 연구 - 전신 뼈 영상을 중심으로 -)

  • Jung, Eun-Mi;Jung, Woo-Young;Ryu, Jae-Kwang;Kim, Dong-Seok
    • The Korean Journal of Nuclear Medicine Technology
    • /
    • 제12권3호
    • /
    • pp.208-213
    • /
    • 2008
  • Purpose: Generally a whole body bone scan has been known as one of the most frequently executed exams in the nuclear medicine fields. Asan medical center, usually use various gamma camera systems - manufactured by PHILIPS (PRECEDENCE, BRIGHTVIEW), SIEMENS (ECAM, ECAM signature, ECAM plus, SYMBIA T2), GE (INFINIA) - to execute whole body scan. But, as we know, each camera's sensitivity is not same so it is hard to consistent diagnosis of patients. So our purpose is when we execute whole body bone scans, we exclude uncontrollable factors and try to correct controllable factors such as inherent sensitivity of gamma camera. In this study, we're going to measure each gamma camera's sensitivity and study about reasonable correction factors of whole body bone scan to follow up patient's condition using different gamma cameras. Materials and Methods: We used the $^{99m}Tc$ flood phantom, it recommend by IAEA recommendation based on general counts rate of a whole body scan and measured counts rates by the use of various gamma cameras - PRECEDENCE, BRIGHTVIEW, ECAM, ECAM signature, ECAM plus, IFINIA - in Asan medical center nuclear medicine department. For measuring sensitivity, all gamma camera equipped LEHR collimator (Low Energy High Resolution multi parallel Collimator) and the $^{99m}Tc$ gamma spectrum was adjusted around 15% window level, the photo peak was set to 140-kev and acquirded for 60 sec and 120 sec in all gamma cameras. In order to verify whether can apply calculated correction factors to whole body bone scan or not, we actually conducted the whole body bone scan to 27 patients and we compared it analyzed that results. Results: After experimenting using $^{99m}Tc$ flood phantom, sensitivity of ECAM plus was highest and other sensitivity order of all gamma camera is ECAM signature, SYMBIA T2, ECAM, BRIGHTVIEW, IFINIA, PRECEDENCE. And yield sensitivity correction factor show each gamma camera's relative sensitivity ratio by yielded based on ECAM's sensitivity. (ECAM plus 1.07, ECAM signature 1.05, SYMBIA T2 1.03, ECAM 1.00, BRIGHTVIEW 0.90, INFINIA 0.83, PRECEDENCE 0.72) When analyzing the correction factor yielded by $^{99m}Tc$ experiment and another correction factor yielded by whole body bone scan, it shows statistically insignificant value (p<0.05) in whole body bone scan diagnosis. Conclusion: In diagnosing the bone metastasis of patients undergoing cancer, whole body bone scan has been conducted as follow up tests due to its good points (high sensitivity, non invasive, easily conducted). But as a follow up study, it's hard to perform whole body bone scan continuously using same gamma camera. If we use same gamma camera to patients, we have to consider effectiveness of equipment's change by time elapsed. So we expect that applying sensitivity correction factor to patients who tested whole body bone scan regularly will add consistence in diagnosis of patients.

  • PDF

Thermomechanical effects on the bending of antisymmetric cross-ply composite plates using a four variable sinusoidal theory

  • Chattibi, F.;Benrahou, Kouider Halim;Benachour, Abdelkader;Nedri, K.;Tounsi, Abdelouahed
    • Steel and Composite Structures
    • /
    • 제19권1호
    • /
    • pp.93-110
    • /
    • 2015
  • The thermomechanical bending response of anti-symmetric cross-ply composite plates is investigated by the use of the simple four variable sinusoidal plate theory. The theory accounts for sinusoidal distribution of transverse shear stress, and satisfies the free transverse shear stress conditions on the top and bottom surfaces of the plate without using shear correction factor. By dividing the transverse displacement into bending and shear parts, the number of unknowns and governing equations for the present theory is reduced, significantly facilitating engineering analysis. The validity of the present theory is demonstrated by comparison with solutions available in the literature. Numerical results are presented to demonstrate the behavior of the system. The influences of aspect ratio, side-to-thickness ratio, thermal expansion coefficients ratio and stacking sequence on the thermally induced response are studied. The present study is relevant to aerospace, chemical process and nuclear engineering structures which may be subjected to intense thermal loads.

Nonlinear analysis of two-directional functionally graded doubly curved panels with porosities

  • Kumar, H.S. Naveen;Kattimani, Subhaschandra
    • Structural Engineering and Mechanics
    • /
    • 제82권4호
    • /
    • pp.477-490
    • /
    • 2022
  • This article investigates the nonlinear behavior of two-directional functionally graded materials (TDFGM) doubly curved panels with porosities for the first time. An improved and effectual approach is established based on the improved first-order shear deformation shell theory (IFSDST) and von Karman's type nonlinearity. The IFSDST considers the effects of shear deformation without the need for a shear correction factor. The composition of TDFGM constitutes four different materials, and the modified power-law function is employed to vary the material properties continuously in both thickness and longitudinal directions. A nonlinear finite element method in conjunction with Hamilton's principle is used to obtain the governing equations. Then, the direct iterative method is incorporated to accomplish the numerical results using the frequency-amplitude, nonlinear central deflection relations. Finally, the influence of volume fraction grading indices, porosity distributions, porosity volume, curvature ratio, thickness ratio, and aspect ratio provides a thorough insight into the linear and nonlinear responses of the porous curved panels. Meanwhile, this study emphasizes the influence of the volume fraction gradation profiles in conjunction with the various material and geometrical parameters on the linear frequency, nonlinear frequency, and deflection of the TDFGM porous shells. The numerical analysis reveals that the frequencies and nonlinear deformations can be significantly regulated by changing the volume fraction gradation profiles in a specified direction with an appropriate combination of materials. Hence, TDFGM panels can overcome the drawbacks of the functionally graded materials with a gradation of properties in a single direction.

A Study on Increasing Reliability of Braking Force Inspection During Regular Inspection of Vehicles (자동차 정기검사에서 제동력 검사의 신뢰성 향상에 관한 연구)

  • Oh, Sang Yeob
    • Transactions of the Korean Society of Mechanical Engineers A
    • /
    • 제40권8호
    • /
    • pp.725-729
    • /
    • 2016
  • The regular inspection of vehicles that are in service in domestic country, i.e., vehicle safety and emission gas inspection have been forced by the korea transportation safety authority and a private servicing enterprise according to the vehicle administration law (1995). In the safety inspection process, which is developed by a compatible inspection system and method, every effort is made to increase the reliability of vehicle safety and the service quality, and to protecting national health. In this study, the reliability of the braking force inspection method in the current regular vehicle inspection was studied statistically by comparing the dynamic braking force inspection method with the static braking force inspection method. Further, the problems and characteristics of the current braking force inspection methods were analyzed. Form the results for the dynamic braking force inspection equipment (H), a mean correction factor (y=18.61+2.18x) was obtained for the axle braking force ratio according to vehicle entering velocity.

Analysis of Fatty Acid in Rice Bran Oil by Gas Chromatography (Gas Chromatography에 의(依)한 미강유(米糠油)의 지방산분석(脂肪酸分析))

  • Chung, T.M.;Shin, J.S.
    • Applied Biological Chemistry
    • /
    • 제9권
    • /
    • pp.29-33
    • /
    • 1968
  • Through an experiment with gas chromatography carried out using diethylene glycol succinate(DEGS) as the packing material of the column, we have obtained the correction factor between the weight ratio and the peak dimension of the saturated fatty acid methyl esters of C10, C12, C14, C16, and C18 and unsaturated fatty acid methyl esters of oleic acid, linoloic acid, and linolenic acid, employing the detector of thermal conductivity type. Quantitative analysis of the fatty acids contained in rice Bran oil was performed with the above correction factor and the results are as follows; 1. Main components were found to be palmitic acid, oleic acid sand linolenic acid. No trases of capric acid (C10) lauric acid (C10) were found. 2. It was confirmed that there were straight line relation between the logarism retention time of each fatty acid and the number of carbon of saturated fatty acid or the number of double bond of other fatty acids having the same number of carbon. 3. The correction factor became larger as to the number of carbon increased up to C18 in case of saturated fatty acids, end as for other fatty acids, and as for other fatty acids of the same carbon number, it became larger according as the number of double bond increased.

  • PDF