• 제목/요약/키워드: Rated load

검색결과 315건 처리시간 0.023초

과부하 운전 압연용 전동기의 과열 정지 시뮬레이션 (Simulation of Thermal Trip in Mill Driver)

  • 이성희;한무호;이왕하;이치환
    • 전력전자학회:학술대회논문집
    • /
    • 전력전자학회 2001년도 전력전자학술대회 논문집
    • /
    • pp.288-291
    • /
    • 2001
  • In steel plant, load torque of mill driver motor is changed periodically because working state and idle state are repeated and load current of working state is necessarily higher than rated motor current. The over current limiter is one of the basic thermal protection method from over heating. In this paper, we analyzed the structure of over current limiter for motor and motor driver systems, developed over current limiter with same operation and structured warning system of action of over current limiter. As using this warning system, we can avoid abrupt plant stop by over current limiter in mill driver and lessen producing loss by plant stop. The developed warning system of action of over current limiter is exactly inspected by computer simulation md analysis of acquired data.

  • PDF

Improvement of Available Battery Capacity in Electric Vehicles

  • Liu, Yow-Chyi
    • Journal of Power Electronics
    • /
    • 제13권3호
    • /
    • pp.497-506
    • /
    • 2013
  • This paper proposes a new method to improve the available battery capacity in electric vehicles by connecting lead-acid batteries with lithium-ion battery in parallel to supply power. In addition, this method combines the discharge characteristics of batteries to improve their efficiency and lower their cost for electric vehicles. A lithium-ion battery set is used to connect with N sets of lead-acid batteries in parallel. The lead-acid battery supplies the initial power. When the lead-acid battery is discharged by the load current until its output voltage drops to the cut-off voltage, the power management unit controls the lead-acid battery and changes it to discharge continuously with a small current. This discharge can be achieved by connecting the lead-acid battery to a lithium-ion battery in parallel to supply the load power or to discharge its current to another lead-acid or lithium-ion battery. Experimental results demonstrates that the available capacity can be improved by up to 30% of the rated capacity of the lead-acid batteries.

Switched Reluctance Motor의 스위칭각 조정에 의한 가변속 구동특성 (Variable speed drive of a Switched Reluctance Motor by adjusting switching angles)

  • 황종규;공관식;황영문
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1993년도 하계학술대회 논문집 B
    • /
    • pp.1026-1029
    • /
    • 1993
  • Inherent speed-torque performance of Switched Reluctance Motor is similar to that of series wound DC motor. Thus, the speed of the motor is extremely regulated according to load torque. For the purpose of controlling the speed and torque of SRM it is necessary to change the applied DC link voltage or the switch-ON and switch-OFF angles which control the phase current of the motor. This paper describes speed-torque characteristics of an integral horse power Switched Reluctance Motor by adjusting the switch-ON and switch-OFF angles. Speed at rated load torque can be regulated by adjusting the switching angles and the control scheme is applied to 2kW, 3 phase, 6/4 SRM.

  • PDF

스타인메츠결선 자기여자 유도발전기의 운전특성 분석 (Analysis of Operating Characteristic of Self Excited Induction Generator with Steinmetz Connection)

  • 강상수;좌종근
    • 전기학회논문지P
    • /
    • 제57권4호
    • /
    • pp.383-387
    • /
    • 2008
  • This paper analyzes the operation characteristics of a self excited induction generator with Steinmetz connection. For this analysis, the symmetrical components analysis is used to obtain the related expressions and the excitation capacitance and the magnetizing reactance are determined in turn by the condition of self excitation which includes the input impedance of the generator as viewed across load terminals. Two simultaneous equations of the condition of self excitation itself are solved by using the real and imaginary function in an application software. This method is applied to simulate the operation characteristics when the generator is driven at rated speed and the specified excitation capacitor is connected across the lagging phase. The results show that better operation characteristics except generated frequency are obtained by using relatively large excitation capacitance and resistive load.

100kW급 MCFC용 계통연계형 Power Conditioning System 개발 (The Development of Power Conditioning System for 100kW MCFC Systems)

  • 정홍주;권형남;정준모;서인영;임희천;안교상
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 2005년도 제36회 하계학술대회 논문집 B
    • /
    • pp.1784-1787
    • /
    • 2005
  • This paper presents the development and testing of a power conditioning system(PCS) for application to a 100kW Molten Carbonate Fuel Cell(MCFC) generation system. The MCFC generation system is a part of a four year government funded research project that began in 2001. This paper presents the results of various tests and performance verification of the 100kW PCS using a DC power system that simulates the DC output of the MCFC fuel cell. Performance of the DC/DC, DC/AC converters were verified, and basic control functions such as grid connection, protection and characteristics of each components were tested. The tests were performed under light load and rated load conditions to verify the operation efficiency, power quality effects, and stability of the PCS.

  • PDF

Test Result Analysis of a 1MW HTS Motor for Industry Application

  • Baik, S.K.;Kwon, Y.K.;Kim, H.M.;Lee, E.Y.;Kim, Y.C.;Park, H.J.;Kwon, W.S.;Park, G.S.
    • 한국초전도ㆍ저온공학회논문지
    • /
    • 제11권2호
    • /
    • pp.33-36
    • /
    • 2009
  • A 1 MW class HTS (High-Temperature Superconducting) synchronous motor has been developed. This motor is aimed to be utilized for industrial application such as large motors operating in large plants. The HTS field coil of the developed motor is cooled by way of neon thermo siphonmechanism and the stator (armature) coil is cooled by water through hollow copper conductor. This paper also describes evaluation of some electrical parameters from performance test results of our motor, which was conducted at steady state in generator mode and motor mode. Open and short circuit tests were conducted in generator mode while a 1.1 MW rated induction machine was rotating the HTS machine. Electrical parameters such as mutual inductance and synchronous inductance are deduced from these tests. Load test was done upto rating torque during motor mode and efficiency was measured at each load torque.

다목적연구용 원자로의 30/5 톤 천정크레인에 대한 지진해석에 관한 연구 (Seismic Analysis of 30/5 Ton Overhead Crane for 30MWTh Korea Multipurpose Research Reactor (KMRR))

  • 유봉;서기석;주용선;홍성인
    • 한국전산구조공학회:학술대회논문집
    • /
    • 한국전산구조공학회 1991년도 가을 학술발표회 논문집
    • /
    • pp.111-114
    • /
    • 1991
  • The KMRR 4-wheel crane which has a span of 30.6m long shall be designed to maintain its structural integrity during and after seismic shocks. Horizontal and vertical FRS for OBE and SSE conditions at the crane support are after seismic shock. Horizontal and vertical FRS for analysis are 4% for OBE and 7% for SSE. The crane consists of girder, saddle main and auxiliary trolley, and necessaries. They are modeled as beam elements and lumped masses for the following 4 cases ; trolley at center of the crane with and without the rated load, trolley at end with and without the rated load. The static analysis as well as the linear dynamic analysis including frequency and response spectrum analysis are performed for the seismic qualification of the crane using the Finite Element Method. For the simplicity of the analysis, the decoupling criteria are considered for the crane rope and the crane supporting beams. The main sections of the crane are stiffened until the calculated stresses satisfy the allowable limits. The seismic resultant loads are used to design the seismic restraints of the saddle and the trolley to protect the clue from the seismic uplifting loads the study results have show that the seismic design of the KMRR crane is governed by the OBE condition. not by the SSE condition. This paper briefly describes the analysis procedure used in the seismic design of the KMRR crane, and summarizes the analysis results.

  • PDF

온도특성을 고려한 공항 저압간선의 경제적인 설계기법에 관한 연구 (A Study on the Economical Design of Airport Low-Voltage Feeder Which is considering the Temperature Character)

  • 최홍규;조계술;송영주
    • 조명전기설비학회논문지
    • /
    • 제17권3호
    • /
    • pp.119-126
    • /
    • 2003
  • 공항과 같이 간선이 길게 포설될 수 있는 장소의 저압간선 굵기는 해당 케이블의 허용전류와 전력계통의 전압강하를 고려하며 결정된다. 비록 도체의 허용전류 값이 부하의 허용전류 값에 비하여 여유가 있을지라도 계통의 허용전압강하를 고려할 경우 도체의 굵기는 비교적 크게 산정될 수 있다. 이러한 경우에, 도체의 허용전류 값은 부하의 최대전류 값보다 훨씬 크게 산정될 수 있으며 상대적으로 도체에서 발생되는 열은 감소하게 된다. 도체의 최대 허용온도에 보정된 도체의 교류저항 값이 저압간선의 굵기 산정을 위한 전압강하 계산공식에 적용되어 왔으며, 도체의 저항 값은 도체의 실제 온도상승 값이 적용된 저항 값에 비하여 크다 본 연구는 도체의 실제 온도상승 값이 보정된 도체의 저항 값을 적용하여 저압간선 굵기 선정 설계 실무에 적용할 수 있도록 일반적인 계산 방식에 비하여 오차가 적은 경제적인 설계 방식을 연구하였다.

건답에서 감자수확작업의 소요동력 및 부하특성 (Consumed-Power and Load Characteristics of Potato Harvesting Operation in Dry Field)

  • 이주연;황석준;남주석;김정길
    • 한국기계가공학회지
    • /
    • 제19권1호
    • /
    • pp.89-99
    • /
    • 2020
  • This study analyzed the load and the consumed power characteristics of a potato harvesting operation in a dry field. The potato harvesting operation was performed using an underground crop harvester mounted on an agricultural tractor with a rated engine power of 23.7 kW. The rotational speeds and the torque of the engine output shaft, rear axle, and power take-off (PTO) shaft were measured under various working conditions. The load spectrum and the consumed power were analyzed using the measured data. The results show that the consumed power of the rear axle increased as the working speed increased, while that of the PTO shaft decreased. The consumed power of the engine output shaft showed a similar trend with that of the PTO shaft, but the torque deviation was larger in the load spectrum. The results of previous studies were used to compare herein the consumed power and the load characteristics of the harvesting, rotary, and plow operations in a dry field. PTO and tractive power were highly consumed in the plow and rotary operations, respectively. The consumed power of the PTO shaft and the rear axle in the harvesting operation were 29-41% and 18-23% of the engine power, respectively. Compared to those in the rotary and plow operations, the engine power was relatively evenly distributed to the PTO shaft and rear axle in the harvesting operation.

차축의 중량 분포와 타이어의 공기압이 트랙터 작업의 연료 효율에 미치는 영향 (Effects of Distribution of Axle Load and Inflation Pressure of Tires on Fuel Efficiency of Tractor Operations)

  • 이진웅;김경욱;김동현;최규정
    • Journal of Biosystems Engineering
    • /
    • 제36권5호
    • /
    • pp.303-313
    • /
    • 2011
  • This study was conducted to investigate the effects of axle weight distribution and inflation pressure of tire on the fuel economy of tractors as well as operational range of tractor engine in terms of engine speed and power when a 4WD tractor of 38.2 kW rated power at 2500 rpm is used for plowing and flooded-field rotavating in paddy fields. (1) Plowing operation required an average engine power of 9.6~13.5 kW which equals 25~35% of rated PTO power. Engine speed ranged from 1,320.4 to 1,737.4 rpm, work velocity from 3.4 to 4.8 km/h, and fuel consumption from 3.2 to 4.2 L/h, respectively. (2) Flooded-field rotavating required an average engine power of 11.5~18.5 kW which equals 30~48.4% of rated PTO power. Out of this 6.2~12.2 kW was used for PTO power. Engine speed ranged from 1,557 to 2,067 rpm, work velocity from 2.5~5.4 km/h and fuel consumption from 3.2~5.5 L/h, respectively. (3) Axle weight distribution, inflation pressure of tire and moisture content of soil did not affect significantly the specific volumetric fuel consumption but affected significantly the fuel consumption per unit area of operation. Fuel savings amounted to 65% in plowing operation and 20% in flooded-field rotavating when the axle weight distribution and inflation pressure of tire were optimally adjusted. (4) Optimal adjustment of axle weight distribution and inflation pressure of tire are expected to save fuel consumption by 10~65% per unit area of operation in plowing and 10~20% in flooded-field rotavating.