Comparison of the non-invasive diagnostic methods, stool antigen test and PCR assay, for Helicobacter felis detection in dogs

  • Hong, Sunhwa;Lee, Hak-Yong;Kim, Tae-Wan;Kim, Okjin
    • Korean Journal of Veterinary Service
    • /
    • v.38 no.1
    • /
    • pp.37-42
    • /
    • 2015
  • The aim of the present study was to compare the non-invasive methods for the diagnosis of H. felis with HpSA kit-based detection method and H. felis-specific PCR assay with dog's stool samples without sacrifice. Male Beagle dogs (n=6) were infected with H. felis ATCC 49179 ($1.0{\times}10^9CFU/dog$) by intra-gastric inoculation two times at 3-day intervals, and the stool specimens of dogs were collected 1, 3, 5, 7, 14, 21 days after infection to submit to HpSA test and H. felis-specific PCR. As the results, the sensitivity of the HpSA and the PCR analysis was 50.0%, 83.3% respectively. Although HpSA test is less sensitive, it could be used for rapid, cheap and easy screening assay for H. felis infection in dog and cats. We suggest that the H. pylori stool antigen kit, HpSA, is useful and effective for monitoring H. felis infection. If HpSA test would be made with H. felis antibodies in the future, its sensitivity could be increased. Also, PCR assay could be successfully used to detect the H. felis in stools. Applying the H. pylori stool antigen kit and PCR assay may be the recommended non-invasive strategy to identify H. felis in dog and cats.

Evaluation of a Rapid Immunochromatography Technique for Determination of Cd in Soils and Rice Grains (면역크로마토그래피를 이용한 토양 및 쌀의 Cd 간이진단법 평가)

  • Lee, Sang-Phil;Kim, Rog-Young;Abe, Kaoru;Kim, Sung-Chul;Kim, Won-Il;Yang, Jae E.
    • Korean Journal of Soil Science and Fertilizer
    • /
    • v.45 no.6
    • /
    • pp.900-903
    • /
    • 2012
  • Cadmium is known to be very toxic to human health and can be relative easily translocated from soils in plants. Therefore, a rapid method for screening Cd in soils and crops has become more and more important. For this reason, we examined a rapid immunochromatograpy (ICG) test kit which uses antigen-antibody reaction based on immunoassay and chromatography. Soils and rice grains collected from mine waste-contaminated sites were determined for their Cd contents using this kit. For comparison purposes, 0.1 M HCl and ICP-OES were employed as a conventional extraction and determination method. Cadmium contents in rice grains determined using ICG technique were $0.46{\sim}2.39mg\;kg^{-1}$ and Cd contents determined using 0.1 M HCl and ICP-OES were $0.52{\sim}1.97mg\;kg^{-1}$. The correlation between these two Cd contents were statistically significant ($r^2$=0.930). The results of Cd contents in soils also showed a statistically significant relationship between these two methods ($r^2$=0.975). On the basis of these results, ICG technique can be applied to rapidly quantify Cd in crops and soils. However, further research is necessary to apply ICG technique for the field screening.

Quantitative Method of Rapid Immunochromatographic Assay Kit for HBsAg-screening using Computer Image Analysis (컴퓨터 상 분석을 이용한 HBsAg-screening용 Rapid Immunochromatographic Assay Kit의 정량적 측정법)

  • 신형순;허태련
    • KSBB Journal
    • /
    • v.15 no.3
    • /
    • pp.243-246
    • /
    • 2000
  • One of recent topics in the case of hepatits B virus(HVB) is the value of hepatitis B surface antigen(HBsAg) concentration as a prognostic maker. We developed uantitative method of rapid immunochromatographic assay(ICA) kit for HBsAg using computer image analysis (CIA) for the purpose of home diagnosis. uantitative ICA using CIA demonstrated integrated optical density(IOD) values proportional to log of reference HBsAg concentrations in the range of 2-200 ng/mL and enzyme-linked immunosorbent assay(ELISA) demonstrated the same in the range of 0.1-100 ng/mL however the test results with sample sear showed the same concentration on both kits. Furthermore repeated tests with the same samples revealed that this quantitative ICA using CIA would be reproducible and coefficient of variation(CV) of the results was 1.38~6.30%.

  • PDF

Comparative Analysis of the Multiple Test Methods for the Detection of Pandemic Influenza A/H1N1 2009 Virus

  • Choi, Young-Jin;Nam, Hae-Seon;Park, Joon-Soo;Kim, Hwi-Jun;Park, Kyung-Bae;Jeon, Min-Hyok;Kim, Chang-Jin;HwangBo, Young;Park, Kwi-Sung;Baek, Kyoung-Ah
    • Journal of Microbiology and Biotechnology
    • /
    • v.20 no.10
    • /
    • pp.1450-1456
    • /
    • 2010
  • Accurate and rapid diagnosis of Pandemic Influenza A/H1N1 2009 virus (H1N1 2009) infection is important for the prevention and control of influenza epidemics and the timely initiation of antiviral treatment. This study was conducted to evaluate the performance of several diagnostic tools for the detection of H1N1 2009. Flocked nasopharyngeal swabs were collected from 254 outpatients of suspected H1N1 2009 during October 2009. This study analyzed the performances of the RealTime Ready Inf A/H1N1 Detection Set (Roche), Influenza A (H1N1) Real-Time Detection Kit (Bionote), Seeplex Influenza A/B OneStep Typing Set [Seeplex Reverse Transcriptase PCR (RT-PCR)], BinaxNow Influenza A & B Test Kit [Binax Rapid Antigen Test (RAT)], and SD BIOLINE Influenza Ag kit (SD RAT). Roche and Bionote real-time RT-PCR showed identical results for the H1N1 2009 hemagglutinin gene. Compared with real-time RT-PCR, the sensitivities and specificities were 83.7% and 100% for Seeplex RT-PCR, 64.5% and 94.7% for Binax RAT, and 69.5% and 100% for SD RAT. The sensitivities of Seeplex RT-PCR, Binax RAT, and SD RAT in patients aged over 21 years were 73.7%, 47.4%, and 57.9%, respectively. The sensitivities of Seeplex RT-PCR, Binax RAT, and SD RAT on the day of initial symptoms were mostly lower (68.8%, 56.3%, and 31.3%, respectively). In conclusion, multiplex RT-PCR and RAT for the detection of H1N1 2009 were significantly less sensitive than real-time RT-PCR. Moreover, a negative RAT may require more sensitive confirmatory assays, because it cannot be ruled out from influenza infection.

Development of Baccillus megaterium Disk Assay Kit for the Determination of Antibacterial Residues in Animal Tissues (식육중 잔류 향균물질의 검출을 위한 Bacillus megaterium 디스크 검사킷트 개발)

  • 손성완;조병훈;진남섭;이혜숙;윤순학;김재학;이재진;이영순
    • Journal of Food Hygiene and Safety
    • /
    • v.11 no.4
    • /
    • pp.315-321
    • /
    • 1996
  • Various antimicrobial drug screen tests have been used in order to ensure food safety. However, the conventional screen tests, the Swab Test on Premises(STOP, USA), the Calf Antibiotic and Sulfa Test(CAST, USA) and the European Economic Community 4-plate Test(FPT, EU) are not sufficiently rapid or sensitive enough to detect low levels of sulfa drugs in meat. We developed a new screen test kit for the determination of the antimicrobial residues in meat called the Bacillus megaterium Disk Assay(BmDA). A comparison of BmDA with the older screen tests showed BmDA was as good as the older ones with several advantages. The new test kit is faster-it can be read in 4∼6 hours instead of 16∼18 hours. Moreover, BmDA can discriminate sulfa drugs from other antimicrobial drugs because p-aminobenzoic acid countacts the inhibiting action of sulfa drugs. Minimum detectable levels of sulfa drugs were significantly improved at the lever of 0.025*0.1 pp, compared with the level of 1.0 ppm in FPT. A comparison of BmDA with the older screen tests in HPLC confirmed meat samples exceeded the Korean tolerance value of 0.1 ppm showed BmDA was the most sensitive in the microbiological screen tests. As the microbiological screen tests have already known, a person familiar with simple laboratory techniques should have no difficulty in using it to detect antimicrobial residues in meat. This would be a simple, economic method of antimicrobial residues detection which might be succesfully used by many laboratories.

  • PDF

Development of a Disperse Dye Immunoassay Technique for Detection of Antibodies against Neospora caninum in Cattle

  • Selahi, Fatemeh;Namavari, Mehdi;Hosseini, Mohammad Hossein;Mansourian, Maryam;Tahamtan, Yahya
    • Parasites, Hosts and Diseases
    • /
    • v.51 no.1
    • /
    • pp.129-132
    • /
    • 2013
  • In this study a disperse dye immunoassay method was standardized and evaluated for detection of antibodies against Neospora caninum in cattle. Sera from 150 cattle with a recent history of abortion were collected and tested by commercial ELISA kit and a standardized in-house dye immunoassay system. The positivity rate for the sera used in this study was 34.6% for the disperse dye immunoassay (DDIA) compared to 32% obtained by ELISA kit. This study showed no significant difference between DDIA and ELISA. The results indicated that the DDIA provide an economic, simple, rapid and robust test for detection of N. caninum infection in cattle.

Development of the rapid detection kit for Salmonella spp. using immunochromatographic assay (면역크로마토그라피 기법을 이용한 Salmonella 속균 신속 검출킷트 개발)

  • Jung, Byeong-yeal;Jung, Suk-chan
    • Korean Journal of Veterinary Research
    • /
    • v.45 no.2
    • /
    • pp.191-197
    • /
    • 2005
  • An immunochromatographic (IC) strip for the rapid detection of Salmonella spp. in the enriched sample was developed. Affinity purified Salmonella polyclonal antibody was conjugated with 40 nm colloidal gold particles which were prepared by citrate method in our laboratory. The antigen-antibody-gold complex was captured by Salmonella antibody attached to test line of nitrocellulose membrane during the capillary migration of sample. Specificity of the IC strip was calculated to be 100% (12/12) and sensitivity was 97.6% (41/42) in the test with pure cultured bacteria. Salmonella was artificially inoculated into raw pork macerated with enrichment broth. And then it was 10-fold diluted from $5.2{\times}10^{8}CFU/ml$ to 5.2 CFU/ml. The IC strip could detect $5.2{\times}10^{6}CFU/ml$ before enrichment. However, the lowest limit of detection was 5.2 CFU/ml after overnight incubation. The results indicated that the IC assay was a rapid, economical and simple method with high specificity and sensitivity for the detection of Salmonella spp. without using any equipment.

Comparison of Acid-Fast Staining, PCR, LCR, PCR-Hybridization for Detection of Mycobacterum Tuberculosis in Clinical Specimens (임상 검체에서 결핵균 검출을 위한 항산성염색, PCR, LCR, PCR-Hybridization 검사법 간의 비교)

  • Choi, Jong-Rak;Lim, Jong-Baeck;Kim, Hyung-Jung
    • Tuberculosis and Respiratory Diseases
    • /
    • v.49 no.3
    • /
    • pp.281-289
    • /
    • 2000
  • Background : Mycobacterial culture is a confirmatory test to detect. M. tuberculosis, but it takes at least 6 weeks to diagnose. PCR is a rapid and sensitive method, but it is known that PCR has a high false positive rate due to contamination, and a high false negative rate due to inhibitors. It is also known that LCR and PCR-Hybridization, recently developed methods, are more specific methods than PCR in terms of detecting M. tuberculosis. In this study, we estimated the clinical utility of in house PCR, LCR and PCR-Hybridization for the detection of M. tuberculosis. Methods : We evaluated 75 specimens, upon which M. tuberculosis culture based testing was requested, by PCR LCR, and PCR-Hybridization and compared results. Mycobacterial culture was performed on 3% Ogawa media for 8 weeks, and an in house PCR, LCx Mycobacterium tuberculosis assay kit (Abbott Laboratories, North Chicago, III) and the AMPLICOR M. tuberculosis test kit (Roche Molecular Systems, Inc. Branchburg, NJ. USA). Results : In the view of the culture results, the sensitivities of the three tests were 40%, 80%, and 100% and their specificities were 98.6%, 94.3%, and 94.3%. Conclusion : LCR and PCR-Hybridization are rapid and sensitive methods for detecting M. tuberculosis in clinical laboratories.

  • PDF

Malaria Endemicity in the Rural Communities of Ebonyi State, Nigeria

  • Nwele, David Ekene;Onyali, Ikechukwu Oliver;Iwueze, Milliam Okwudili;Elom, Michael Okpara;Uguru, Ogbonna Elom Sabastian
    • Parasites, Hosts and Diseases
    • /
    • v.60 no.3
    • /
    • pp.173-179
    • /
    • 2022
  • Malaria remains a global health threat. Approximately 97% of the population is at risk in sub-Saharan countries, particularly Nigeria. This study compared the performance of 2 diagnostic methods in assessing malaria endemicity in the rural communities of Ebonyi State, Nigeria. A total of 1,140 study participants were screened for malaria parasite using Rapid Diagnostic Test kits (RDT) in the field, while thick and thin films for microscopy were examined in the laboratory. Our result showed that malaria prevalence was 56.8 by RDT and 38.6% by microscopic test. Age group under 10 years had the highest prevalence of 28.9% (RDT) and 23.6% (microscopy), respectively. The highest prevalence of 19.5% by RDT was recorded in Onicha Local Government Area, while the highest prevalence of 13.4% with microscopy was recorded in Ezza North Local Government Area. The sensitivity and specificity of microscopic examination were both 100%, while those of RDT were 95.5% and 75.9%, respectively.

A Rapid Diagnostic Test for Toxoplasmosis using Recombinant Antigenic N-terminal Half of SAG1 Linked with Intrinsically Unstructured Domain of GRA2 Protein

  • Song, Kyoung Ju;Yang, Zhaoshou;Chong, Chom-Kyu;Kim, Jin-Soo;Lee, Kyung Chan;Kim, Tong-Soo;Nam, Ho-Woo
    • Parasites, Hosts and Diseases
    • /
    • v.51 no.5
    • /
    • pp.503-510
    • /
    • 2013
  • Toxoplasma gondii is an apicomplexan parasite with a broad host range of most warm-blooded mammals including humans, of which one-thirds of the human population has been infected worldwide which can cause congenital defects, abortion, and neonatal complications. Here, we developed a rapid diagnostic test (RDT) for T. gondii infection. Antigenic N-terminal half of the major surface antigen (SAG1) was linked with intrinsically unstructured domain (IUD) of dense granule protein 2 (GRA2). The recombinant GST-GRA2-SAG1A protein was successfully expressed and purified as 51 kDa of molecular weight. Furthermore, antigenicity and solubility of the rGST-GRA2-SAG1A protein were significantly increased. The overall specificity and sensitivity of GST-GRA2-SAG1A loaded RDT (TgRDT) were estimated as 100% and 97.1% by comparing with ELISA result which uses T. gondii whole cell lysates as the antigen. The TgRDT tested with Uganda people sera for field trial and showed 31.9% of seroprevalence against T. gondii antibody. The TgRDT is proved to be a kit for rapid and easy to use with high accuracy, which would be a suitable serodiagnostic tool for toxoplasmosis.