• Title/Summary/Keyword: Rapid Forensic

Search Result 46, Processing Time 0.034 seconds

Forensic Evaluation of Prostate-Specific-Antigen (PSA) Rapid Test Kit for Identification of Human Semen (전립선특이항원검사 Kit에 의한 정액의 신속 검출법)

  • Lim, Chae-Won;Lee, Jong-Hoon;Kim, Hyung-Lak
    • Korean Journal of Clinical Laboratory Science
    • /
    • v.41 no.2
    • /
    • pp.76-82
    • /
    • 2009
  • It would be one of the most important tests that determination of semen in crime scene as a matter of significant evidences. Recently, it has been developed for the identification of semen in forensic specimens which was used simply, easily and reproductively. In this study, Prostate-Specific-Antigen (PSA) Rapid Test kit was evaluated for the forensic identification of semen and compared with one step semen inspection forensic rapid test kit. The sensitivity and specificity of the rapid PSA kit were examined in addition to the stability of PSA. The positive band of rapid PSA kit shown even with 1,000,000-fold diluted semen, which was at least 100 timed higher than qualitative one step semen inspection forensic rapid test kit. PSA was detected in urine from normal male adult, however, it was not detected in urine from young boys and female body fluids. It was shown that PSA was very stable to resist boiling for 20 minutes and the effect of bacteria. In crime scene investigation, rapid PSA kit is expected to help to identify semen easily in the evidences.

  • PDF

Comparative study of serological detection methods on old bloodstain samples (오래된 혈흔 시료에 대한 혈청학적 식별법의 비교 연구)

  • Lee, Minji;Ahn, Eu-Ree;Kim, Da-Hye;Shin, Heejin;Jung, Ju Yeon;Lee, Sung-Jin;Chun, Byung-Won
    • Analytical Science and Technology
    • /
    • v.31 no.5
    • /
    • pp.201-207
    • /
    • 2018
  • Blood is a commonly found body fluid at crime scenes, and plays an important role in identifying suspects and in the reconstruction of crime scenes. Although serological detection of blood has been widely used in the field of forensic science, research on the detection of old bloodstains is scarce. This work aimed to compare various methods for the detection of old bloodstains and validate the reliability of their results. Four presumptive tests-Tetramethylbenzidine, $Bluestar^{(R)}$, Leucomalachite Green, Kastle-Meyer tests-and two confirmatory tests-Fecal Occult Blood (FOB) and Rapid Stain $Identification^{(TM)}-Blood$ ($RSID^{TM}-Blood$) tests-were compared. Bloodstain samples from post-mortem cases were collected on gauzes and then stored at room temperature for periods from 7 to 30 years. All the presumptive tests were positive, even for the 30-year-old sample. However, FOB and $RSID^{TM}-Blood$ provided false negative results for some samples stored for 17 years or more (1988 to 2001). The results indicate that FOB and $RSID^{TM}-Blood$ are not reliable for the detection of old bloodstains. These findings can be useful in the selection of an appropriate detection method for serological testing of old bloodstains. In addition, the information will be useful background knowledge when applied in the field of forensic practice.

Evaluation of Rapid IgG4 Test for Diagnosis of Gnathostomiasis

  • Wang, Yue;Ma, An;Liu, Xiao-Long;Eamsobhana, Praphathip;Gan, Xiao-Xian
    • Parasites, Hosts and Diseases
    • /
    • v.59 no.3
    • /
    • pp.257-263
    • /
    • 2021
  • Human gnathostomiasis is a parasitic disease caused by Gnathostoma nematode infection. A rapid, reliable, and practical immunoassay, named dot immuno-gold filtration assay (DIGFA), was developed to supporting clinical diagnosis of gnathostomiasis. The practical tool detected anti-Gnathostoma-specific IgG4 in human serum using crude extract of third-stage larvae as antigen. The result of the test was shown by anti-human IgG4 monoclonal antibody conjugated colloidal gold. The sensitivity and specificity of the test were both 100% for detection in human sera from patients with gnathostomiasis (13/13) and from healthy negative controls (50/50), respectively. Cross-reactivity with heterogonous serum samples from patients with other helminthiases ranged from 0 (trichinosis, paragonimiasis, clonorchiasis, schistosomiasis, and cysticercosis) to 25.0% (sparganosis), with an average of 6.3% (7/112). Moreover, specific IgG4 antibodies diminished at 6 months after treatment. This study showed that DIGFA for the detection of specific IgG4 in human sera could be a promising tool for the diagnosis of gnathostomiasis and useful for evaluating therapeutic effects.

Validation of Analytical Method for Male Sex Hormone Monitoring in Urine due to the Chemical Castration (성충동약물치료 시행에 따른 소변 중 남성호르몬의 분석법 확립)

  • Jeong, Sujin;Baeck, Seungkyung;Park, Sunhye;Son, Kkonnip;Park, Yonghoon;Lee, Sangki
    • YAKHAK HOEJI
    • /
    • v.57 no.5
    • /
    • pp.330-336
    • /
    • 2013
  • "The Act on Medication Treatment of Sexual Impulse of Sex Offenders" known as chemical castration has been effective since July 2011 in Korea. According to the law, monitoring of male sex hormone in urine is enforced to request National Forensic Service more than once a month after injection of medicine designed to reduce sex impulse. We established a rapid and sensitive method for the monitoring of testosterone (T) and epitestosterone (E) in human urine by liquid chromatography with tandem mass spectrometry (LC-MS/MS). Three mL of urine was pretreated by solid-phase extraction for purification and performed enzymatic hydrolysis. The pretreated samples were extracted twice with 2 ml of ethyl acetate and n-hexane (2 : 3). The separation was applied on Thermo Hypersil GOLD C18 column ($1.9{\mu}m$, $100{\times}2.1mm$). A gradient elution of methanol and water of 0.1% formic acid were used as mobile phase and the retention time was less than 10 min. LC-MS/MS system coupled with an electrospray ionization source was performed in multiple reaction monitoring mode. The transitions of the analytes executed as following: m/z $289{\rightarrow}97$, 109 for T and E, m/z $292{\rightarrow}109$ for $T-d_3$ and $E-d_3$ as internal standards. The validation results of the method were satisfactory. The limits of detection were 0.05 ng/ml and the limits of quantification were 0.1 ng/ml. This method was successfully applied to real human urine sample. The developed method will be useful for monitoring T/E ratio in urine of sex offenders.

Development of Rapid and Simple Drug Identification and Semi Quantitative Analytical Program by Gas Chromatography-Mass Spectrometry (가스크로마토그래피/질량분석기를 이용한 약물의 확인 및 간이 정량분석 프로그램 개발)

  • Kim, Eun-Mi;Han, Eun-Young;Hong, Hyo-Jeong;Jeong, Su-Jin;Choe, Sang-Gil;Rhee, Jong-Sook;Jung, Jin-Mi;Yeom, Hye-Sun;Lee, Han-Sun;Lee, Sang-Ki
    • YAKHAK HOEJI
    • /
    • v.55 no.2
    • /
    • pp.106-115
    • /
    • 2011
  • Systematic toxicological analysis (STA) means the process for general unknown screening of drugs and toxic compounds in biological fluids. In order to establish STA, in previous study we investigated pattern of drugs & poisons in autopsy cases during 2007~2009 in Korea, and finally selected 62 drugs as target drugs for STA. In this study, rapid and simple drug identification and quantitative analytical program by gas chromatography-mass spectrometry(GC-MS) was developed. The in-house program, "DrugMan", consisted of modified chemstation data analysis menu and newly developed macro modules. Total 55 drugs among 62 target drugs were applied to this program, they were 14 antidepressants, 8 anti-histamines, 5 sedatives/hypnotics, 5 narcotic analgesics, 3 antipsychotic drugs, and etc. For calibration curves, fifty five drugs were divided into four groups of range considering their therapeutic or toxic concentrations in blood specimen, i.e. 0.05~1 mg/l, 0.1~1 mg/l, 0.1~5 mg/l or 0.5~10 mg/l. Standards spiked bloods were extracted by solid-phase extraction (SPE) with trimipramine-D3 as internal standard. Parameters such as retention times, 3 mass fragment ions, and calibration curves for each drug were registered to DrugMan. A series of identification, semi quantitation of target drugs and reporting the results were performed automatically. Calibration curves for most drugs were linear with correlation coefficients exceeding 0.98. Sensitivity rate of DrugMan was 0.90 (90%) for 55 drugs at the level of 0.5 mg/l. For standard spiked bloods at the level of 0.5 mg/l for 29 drugs, semi quantitative concentrations were ranged 0.36~0.64 mg/l by DrugMan. If more drugs are registered to database in DrugMan in further study, it will be useful tools for STA in forensic toxicology.

The analytical application for cement using X-Ray diffraction and X-Ray fluorescence spectrometer (X-Ray Diffraction과 X-Ray Fluorescence를 이용한 시멘트 비교 분석)

  • Jung, Ji Eun;Jang, Yu Rim;Kim, Ki-Wook;Heo, Sangcheol;Min, Ji-Sook
    • Analytical Science and Technology
    • /
    • v.26 no.5
    • /
    • pp.340-351
    • /
    • 2013
  • The chemical element and structural characterization of different types of cements and its brick stones are been investigated under forensic aspects using X-ray florescence (XRF) and X-ray diffraction (XRD) spectrometer. The XRF provides rapid compositional data for controlling almost all stages of raw materials, clinker and cement. The decisive advantage of XRD methods is based on the unique character of the diffraction patterns of crystalline substances, the ability to distinguish between elements and their oxides, and the possibility to identify chemical compounds, polymeric forms, and mixed crystals by non-destructive examination. Therefore, combination of these examinations is useful and able to apply for the forensic analysis in comparison of cements and brick stones. There are more study remained to determine the viability of method for forensic analysis of brick stones and the limits of the discrimination that can be achieved.

A experimental Study on Insulation Breaking Fire Case of Starter Motor B Terminal (스타트모터 B단자 절연파괴 화재사례에 대한 실험적 연구)

  • Woo, Seung Woo;Park, J.M.;Hyun, B.S.;Nam, J.W.;Park, W.S.;Kim, J.P.;Cho, Y.J.;Goh, J.M.;Park, N.K.
    • Journal of the Korean Society of Safety
    • /
    • v.34 no.5
    • /
    • pp.55-62
    • /
    • 2019
  • In this paper, we introduce a case of a fire accident during parking of a large truck that is repeatedly occurring. The shape and location of the combustion and electrical singularity commonly found in other vehicle fire accidents could limit the starter motor as the ignition section. In addition, it was possible to confirm the electrical melting singularity that could act as a cause of ignition between the start motor B terminal and the start motor enclosure. By combining the above investigations and investigations, it was possible to estimate the electric fire expressed from insulation breaking of the starter motor B terminal, and by using the renewable starter motor comparison product mounted on the fire vehicle, an experiment was performed to reproduce the ignition process from the starter motor under specific conditions. So. It is hoped that this will raise awareness about vehicle fires, which can lead to large fires or casualties, share the risks of using starter motors for regeneration, and help in the rapid and accurate investigation of similar vehicle fires in the future.

A Study on the Current State and Improvement of Operation of Fire Investigation Teams (화재조사 실태 분석과 개선방안에 관한 연구)

  • Lee, Tae-Geun;Chae, Jong-Min
    • Journal of forensic and investigative science
    • /
    • v.1 no.1
    • /
    • pp.45-53
    • /
    • 2006
  • The purposes of fire investigation are to identify and analyze the causes of fire and, using the results in promoting fire fighting policies, ultimately to prevent fires caused by similar causes and to protect people's life and properties from fire. However, although the patterns of fire are getting more diverse and complicated with the rapid development of industry, complicated with the rapid development of industry, fire fighting organizations are continuing traditional superficial fire investigation without operating a fire investigation department for the reason of insufficient manpower, equipment and budget, losing public confidence. Thus, the present study purposed to propose plans to improve the technicality of fire investigation and win public confidence in fire investigation. First, the technicality of fire investigation should be improved by operating a department and personnel exclusively for fire investigation. Second, fire investigation should be more scientific and precise using high tech fire investigation equipment. Lastly, responsible fire fighting administration should be realized through statistical analysis of the causes of fire and computerization. The results of this study are expected to contribute to the safety and security of our society.

  • PDF

A Technology-Strategy Integrated Digital Forensic Process Framework Considering Government ICT R&D Strategy and ICT Paradigm Shift (정부 ICT R&D 중장기전략과 ICT 패러다임 변화를 반영한 디지털 포렌식 표준정립을 위한 기술-정책적 통합프로세스 프레임워크)

  • Shin, Jun Woo
    • Journal of the Korea Institute of Information and Communication Engineering
    • /
    • v.18 no.7
    • /
    • pp.1495-1504
    • /
    • 2014
  • Currently information related service such as internet banking, chatting, social network services are quite well smeared into our daily life. Moreover, a rapid growth of service using smart devices brought an importance of security in internet services and a research activation of digital forensic in a crime investigation. This paper presented a previous digital forensic research trend and based on this, suggested a technology-strategy integrated digital forensic process platform, taking a mid-long term government leading ICT R&D strategy and ICT paradigm shift into account.

A Study on the Combustion Characteristic of Building Materials (건축용 내장재의 연소 특성에 관한 연구)

  • Song, Jae-Yong;Sa, Seung-Hun;Nam, Jung-Woo;Kim, Jin-Pyo;Park, Jong-Taek
    • Journal of the Korean Society of Safety
    • /
    • v.26 no.3
    • /
    • pp.23-28
    • /
    • 2011
  • This paper studied combustion characteristics of the building materials such as polyurethane-foam, sponge type sound-absorbing materials and styrofoam. To estimate of the combustion characteristics, we carried out combustion experiment of the building materials. And then to evaluate the suitability of the building materials, we measured heat release rate(HRR) and smoke density(Ds) of polyurethane-foam, sponge type sound-absorbing materials and styrofoam using by a cone-calorimeter. From the combustion experimental results, the general type sound-absorbing materials (GSAM) and styrofoam were rapid burned simultaneously with ignition and the incombustibility type sound-absorbing materials(ISAM) and polyurethane-foam had all gone out simultaneously with ignition. Measured results of HRR and Ds were not satisfied KS F ISO 5660-1 and IMO FTP Code, from the results, the polyurethane-foam, the sponge type sound-absorbing material and the styrofoam were ill-suited for using building interior materials.