• Title/Summary/Keyword: Range Calibration Error

Search Result 186, Processing Time 0.026 seconds

Comparative Analysis on the Mock-ups' Configuration and Monitoring Protocol System of Advanced Daylighting Systems for Daylighting Experiment - Focused on IEA SHC Task21- (첨단채광시스템 실험용 Mock-Up 모형의 형상 및 모니터링 프로토콜 시스템에 관한 비교분석 - IEA SHC Task21을 중심으로-)

  • Jeong, In-Young;Choi, Sang-Hyun;Kim, Jeong-Tai
    • KIEAE Journal
    • /
    • v.4 no.1
    • /
    • pp.11-20
    • /
    • 2004
  • Innovative daylighting systems in buildings in various climatic zones around the world have been developed under the IEA SHC Task21. The performance assessment were obtained by monitoring the most systems using full-scale test model rooms or actual buildings under real sky conditions. This study aims to analyze the configuration and monitoring system of the nine Mock-up models of the IEA SHC Task21 comparatively. For the purpose, the geometry of the test rooms (length, width, height, window area, glazed area and occupied), reflectance of walls, floor and ceiling, transmittance of glazing (transmittance for hemispherical irradiation, normal irradiation and U-value) were compared. And equipment for measurement (manufacturer, range, calibration, maximum calibration error, cosine response error, fatigue error), and data acquisition system (manufacturer, type, number of differential analogue input channels, A/D converter resolution in bits, data acquisition software) were also analyzed comparatively. Some findings of these experimental methodology of standard monitoring have been proven to be a valuable one for future assessment of advanced daylighting systems in our country.

Development of The Standard Current Transformer with Wide Ratio Error and Its Application (광범위 비오차 표준 전류변성기의 개발 및 그 응용)

  • Kwon, Sung-Won;Jung, Jae-Kap;Lee, Sang-Hwa;Kim, Mun-Seog;Kim, Myung-Soo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.6
    • /
    • pp.302-307
    • /
    • 2006
  • Standard current transformer(CT) with the nominal ratio errors in the range of - 10 % to + 10 % has been developed. Linearity of the CT ratio error measuring system (CT comparator) has been tested by using wide ratio error standard current transformer(WRE CT). The developed WRE CT can be used to evaluate the linearity of the CT comparator by comparing both the theoretical values and experimental values of the WRE CT. The developed method has been successfully applied for calibration and correction in the CT comparator belonging to industry.

Ship Detection by Satellite Data: Radiometric and Geometric Calibrations of RADARS AT Data (위성 데이터에 의한 선박 탐지: RADARSAT의 대기보정과 기하보정)

  • Yang, Chan-Su
    • Journal of the Korean Society of Marine Environment & Safety
    • /
    • v.10 no.1 s.20
    • /
    • pp.1-7
    • /
    • 2004
  • RADARSAT is one of many possible data sources that can play an important role in marine surveillance including ship detection because radar sensors have the two primary advantages: all-weather and day or night imaging. However, atmospheric effects on SAR imaging can not be bypassed and any remote sensing image has various geometric distortions, In this study, radiometric and geometric calibrations for RADARSAT/SAT data are tried using SGX products georeferenced as level 1. Even comparison of the near vs. far range sections of the same images requires such calibration Radiometric calibration is performed by compensating for effects of local illuminated area and incidence angle on the local backscatter, Conversion method of the pixel DNs to beta nought and sigma nought is also investigated. Finally, automatic geometric calibration based on the 4 pixels from the header file is compared to a marine chart. The errors for latitude and longitude directions are 300m and 260m, respectively. It can be concluded that the error extent is acceptable for an application to open sea and can be calibrated using a ground control point.

  • PDF

Pixel-level Current Mirroring Injection with 2-step Bias-current Suppression for 2-D Microbolometer FPAs (이차원 마이크로볼로미터 FPA를 위한 이 단계 바이어스 전류 억제 방식을 갖는 픽셀 단위의 전류 미러 신호취득 회로)

  • Hwang, Chi Ho;Woo, Doo Hyung
    • Journal of the Institute of Electronics and Information Engineers
    • /
    • v.52 no.11
    • /
    • pp.36-43
    • /
    • 2015
  • A pixel-level readout circuit is studied for 2-dimensional microbolometer focal plane arrays (FPAs). A current mirroring injection (CMI) input circuit with 2-step current-mode bias suppression is proposed for a pixel-level architecture with high responsivity and long integration time. The proposed circuit has been designed using a $0.35-{\mu}m$ 2-poly 4-metal CMOS process for a $320{\times}240$ microbolometer array with a pixel size of $50{\mu}m{\times}50{\mu}m$. The proposed 2-step bias-current suppression has sufficiently low calibration error with wide calibration range, and the calibration range and error can be easily optimized by controlling some design parameters. Due to high responsivity and a long integration time of more than 1 ms, the noise equivalent temperature difference (NETD) of the proposed circuit can be improved to 26 mK, which is much better than that of the conventional circuits, 67 mK.

A Study for Efficient Methods of System Calibration between Optical and Range Sensors by Using Simulation (시뮬레이션을 통한 광학 및 레인지 센서 간의 효율적인 시스템 캘리브레이션 설계)

  • Won Seok, Choi;Chang Jae, Kim;Yong Il, Kim
    • Journal of the Korean Society of Surveying, Geodesy, Photogrammetry and Cartography
    • /
    • v.33 no.2
    • /
    • pp.95-101
    • /
    • 2015
  • The study planned to suggest the efficient methods of system calibration between the range and optical sensors. The simulation was performed by considering i) design of test-bed, ii) mathematical methods of system calibration and iii) locations of the sensors. The test-bed was designed by considering specifications of the range and optical sensors. Also, the error levels of each sensor were considered in the process of simulation with dataset, which was generated under these predetermined conditions. The system calibration was carried out by using the simulated dataset in two different approaches, which are single photo resection and bundle adjustment. The results from the simulation determined that the bundle adjustment method is more efficient than the single photo resection in the system calibration between range and optical sensors. For the better results, we have used the data, obtained in various locations. In a conclusion, the most efficient case was in sequence of i) the bundle adjustment with ii) the simulated dataset, which were obtained between 2m to 4m away from the test-bed.

Calibration of VLP-16 Lidar Sensor and Vision Cameras Using the Center Coordinates of a Spherical Object (구형물체의 중심좌표를 이용한 VLP-16 라이다 센서와 비전 카메라 사이의 보정)

  • Lee, Ju-Hwan;Lee, Geun-Mo;Park, Soon-Yong
    • KIPS Transactions on Software and Data Engineering
    • /
    • v.8 no.2
    • /
    • pp.89-96
    • /
    • 2019
  • 360 degree 3-dimensional lidar sensors and vision cameras are commonly used in the development of autonomous driving techniques for automobile, drone, etc. By the way, existing calibration techniques for obtaining th e external transformation of the lidar and the camera sensors have disadvantages in that special calibration objects are used or the object size is too large. In this paper, we introduce a simple calibration method between two sensors using a spherical object. We calculated the sphere center coordinates using four 3-D points selected by RANSAC of the range data of the sphere. The 2-dimensional coordinates of the object center in the camera image are also detected to calibrate the two sensors. Even when the range data is acquired from various angles, the image of the spherical object always maintains a circular shape. The proposed method results in about 2 pixel reprojection error, and the performance of the proposed technique is analyzed by comparing with the existing methods.

A Capacitor Mismatch Error Cancelation Technique for High-Speed High-Resolution Pipeline ADC

  • Park, Cheonwi;Lee, Byung-Geun
    • IEIE Transactions on Smart Processing and Computing
    • /
    • v.3 no.4
    • /
    • pp.161-166
    • /
    • 2014
  • An accurate gain-of-two amplifier, which successfully reduces the capacitor mismatch error is proposed. This amplifier has similar circuit complexity and linearity improvement to the capacitor error-averaging technique, but operates with two clock phases just like the conventional pipeline stage. This makes it suitable for high-speed, high-resolution analog-to-digital converters (ADCs). Two ADC architectures employing the proposed accurate gain-of-two amplifier are also presented. The simulation results show that the proposed ADCs can achieve 15-bit linearity with 8-bit capacitor matching.

Development of The Accurate Potential Transformer with Wide Ratio Error and Its Application (초정밀 광범위 비오차 전압변성기의 개발 및 그 응용)

  • Kwon, Sung-Won;Jung, Jae-Kap;Lee, Sang-Hwa;Kim, Myung-Soo
    • The Transactions of the Korean Institute of Electrical Engineers C
    • /
    • v.55 no.6
    • /
    • pp.317-322
    • /
    • 2006
  • A accurate potential transformer(PT) with the nominal ratio errors in the wide range of - 9 % to + 11 % has been developed. The developed wide ratio error PT can be used to evaluate the linearity of the PT comparator by comparing both the theoretical values as standard values and experimental values of the PT. The new method has been successfully applied for calibration and correction in the PT comparator including very low ratio error values from ${\pm}0.005%$ to ${\pm}0.3%$ belonging to industry.

Proposal of Parameter Range that Offered Optimal Performance in the Coastal Morphodynamic Model (XBeach) Through GLUE

  • Bae, Hyunwoo;Do, Kideok;Kim, Inho;Chang, Sungyeol
    • Journal of Ocean Engineering and Technology
    • /
    • v.36 no.4
    • /
    • pp.251-269
    • /
    • 2022
  • The process-based XBeach model has numerous empirical parameters because of insufficient understanding of hydrodynamics and sediment transport on the nearshore; hence, it is necessary to calibrate parameters to apply to various study areas and wave conditions. Therefore, the calibration process of parameters is essential for the improvement of model performance. Generally, the trial-and-error method is widely used; however, this method is passive and limited to various and comprehensive parameter ranges. In this study, the Generalized Likelihood Uncertainty Estimation (GLUE) method was used to estimate the optimal range of three parameters (gamma, facua, and gamma2) using morphological field data collected in Maengbang beach during the four typhoons that struck from September to October 2019. The model performance and optimal range of empirical parameters were evaluated using Brier Skill Score (BSS) along with the baseline profiles, sensitivity, and likelihood density analysis of BSS in the GLUE tools. Accordingly, the optimal parameter combinations were derived when facua was less than 0.15 and simulated well the shifting shape, from crescentic sand bar to alongshore uniform sand bars in the surf zone of Maengbang beach after storm impact. However, the erosion and accretion patterns nearby in the surf zone and shoreline remain challenges in the XBeach model.

Determination of Hydrogen Peroxide Concentration by Portable Near-Infrared (NIR) System (근적외분광분석법을 이용한 과산화수소의 농도 측정)

  • 임현량;우영아;장수현;김경미;김효진
    • YAKHAK HOEJI
    • /
    • v.46 no.5
    • /
    • pp.324-330
    • /
    • 2002
  • This experiment was carried out to determine non-destructively the hydrogen peroxide concentration of 3% antiseptic hydrogen peroxide solutions by portable near-infrared (NIR) system. Hydrogen peroxide standards were prepared ranging from 0 to 25.6 w/w% and the NIR spectra of hydrogen peroxide standard solutions were collected by using a quartz cell in 1 mm pathlength. We found the variation of absorbance band due to OH vibration of hydrogen peroxide depending on the concentration around 1400 nm in the second derivatives spectra. Partial least square regression (PLSR) and multilinear regression (MLR) were explored to develop a calibration model over the spectral range 1100-1720 nm. The model using PLSR was better than that using MLR. The calibration showed good results with a standard error of prediction (SEP) of 0.16%. In order to validate the developed calibration model, routine analyses were performed using commercial antiseptic hydrogen peroxide solutions. The hydrogen peroxide values from the NIR calibration model were compared with the values from a redox titration method. The NIR routine analyses results showed good correlation with those of the redox titration method. This study showed that the rapid and non-destructive determination of hydrogen peroxide in the antiseptic solution was successfully performed by portable NIR system without very harmful solvents.