• 제목/요약/키워드: Rail Insulation

검색결과 25건 처리시간 0.028초

철도차량용 주름판재의 차음성능 (Sound Insulation Performance of Corrugated Panels for Rail Way Vehicles)

  • 김석현;박정모
    • 산업기술연구
    • /
    • 제20권B호
    • /
    • pp.9-14
    • /
    • 2000
  • Sound insulation performance is investigated on the corrugated panel used for a rail way vehicle. Random incidence sound transmission loss is calculated by using the equivalent orthotropic plate model. Analysis results on several kinds of corrugated panels are in good agreement with the measured data. The analysis method is applied to predict the sound transmission loss of the corrugated panel used for Korean high speed train.

  • PDF

레일체결장치용 경량화숄더(코일스프링클립걸이)개발 (Development of a Lightweight Rail Fastener Clip Shoulder)

  • 양재성;백광일;남보현
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 춘계학술대회 논문집
    • /
    • pp.487-494
    • /
    • 2000
  • 현재 국내에서 사용되고 있는 팬드롤형 체결구의 레일체결장치용 숄더는 구조상으로 숄더와 콘크리트 침목 단차에서의 재료분리를 유발시키고 있으며 현장에서 궤도의 PC침목 자체는 완전절연상태가 아니므로 절연블럭의 미삽입 또는 탈락시 궤도가 단락 되어 신호기애 장애가 발생하거나 열차 미운행시에도 건널목 정보장치와 차단기가 동작되는 등의 문제가 발생하여 근본적인 대비책 강구가 요망되어 온 상태이다. 본 연구에서는 레일체결장치용 숄더의 구조적 개선 및 경량화와 숄더의 절연성능 향상을 위한 신형숄더를 개발하였다.

  • PDF

고무차륜시스템에서의 지락보호를 위한 급전선로 절연과 부극전위와의 영향 분석 (An Analysis of Influence Between the Power Feeding Line Insulation and Negative Rail Potential for the DC Ground Fault Protection in the Rubber Wheel System)

  • 정호성;신승권;김형철;박영;조상훈
    • 전기학회논문지
    • /
    • 제62권4호
    • /
    • pp.577-583
    • /
    • 2013
  • We have analyzed influence of potential rise in negative bus, which caused by decrease of power feeding line insulation, upon protecting method of DC ground protection device which detecting potential rise between negative bus and ground in order to detect ground fault in the rubber wheel system. For this purpose, we proposed negative potential equation between negative bus and ground and calculated negative potential according to system condition changes by estimating power feeding line insulation changes in steel wheel system and rubber wheel system, and equalizing DC power feeding system when ground fault occurred. Also, in order to estimate negative potential of real system, we modeled the rubber wheel system, and simulated normal status, grounding fault occurrence and power feeding line insulation changes. In normal status, negative potential did not rise significantly regardless of vehicle operation. When ground fault occurred, negative potential rose up over 300V regardless of fault resistance. However, we also observed that negative potential rose when power feeding line insulation dropped down under $1M{\Omega}$. In conclusion, our result shows that in case of rubber wheel system unlike steel wheel system, relay will be prevented maloperation and insulation status observation can be ensured when ground over voltage relay will be set 200V ~ 300V.

직류 전기철도에서의 레일전위 및 누설전류 해석을 위한 시뮬레이션 모델링 (A Simulation Modeling for Rail Potential and Leakage Current Analysis in DC Traction System)

  • 윤임중;이종우
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2008년도 추계학술대회 논문집
    • /
    • pp.196-201
    • /
    • 2008
  • In DC traction systems, a part of feedback current returning through rails becomes leakage current, illumination on a metal laid underground results from the leakage current to ground. To prevent the leakage current on rails, feedback rails almost have insulated with the ground. Insulation between rails and the ground causes that the earth method changes a isolated method in DC traction systems. the rail potential rise results in the isolated method. the rail potential rise causes an electric shock when a person touches the ground and rolling stock. To decrease the rail potential rise and leakage current, there are methods for reducing the feedback resistance and current of rails, increasing the leakage resistance, decreasing the distance between substations. But it are necessary to forecast and analyze the rail potential and amplitude of leakage current. In this paper, we modeled DC traction systems and feedback circuit to simulate the rail potential and amplitude of leakage current using PSCAD/EMTDC that is power analysis program, forecasted the rail potential and amplitude of leakage current about changing various parameters in the electric circuit. By using the simulation model, we easily will forecast the rail potential and amplitude of leakage current in case of a level of basic design and maintenance in electric railway systems, valuably use basic data in case of system selection.

  • PDF

철도 차량용 주름 판재의 국부진동 모드 (Local Vibration Modes of Corrugated Panels for Rail Road Vehicles)

  • 김석현;장호식
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2000년도 추계학술대회 논문집
    • /
    • pp.527-534
    • /
    • 2000
  • Characteristics of local vibration modes of a corrugated panel are investigated by finite element analysis and modal testing. Structural modification model in the corrugation is proposed to increase the resonance frequency. This model decreases the fall by the local resonance in the transmission loss of the corrugated pallet and improves sound insulation performance. Damping effect of tile foam filled ill tile core cavity is also estimated by experiment The results of tile study offer useful information how to predict the severe local resonances in corrugations and how to prevent their undesirable effect ell the sound insulation and the vibration transmission.

  • PDF

도시형 자기부상열차 분기기 구간의 제3궤조 전차선 시스템 개발 (The Development of Third-Rail System Applied to Turn-out Section for Urban Maglev)

  • 민병찬;허영태;홍두영;이원주;조수연;정남철
    • 한국철도학회:학술대회논문집
    • /
    • 한국철도학회 2011년도 정기총회 및 추계학술대회 논문집
    • /
    • pp.3046-3051
    • /
    • 2011
  • The third-rail system is an important device supplying power directly to the Maglev train through physical contact with the collecting shoe. It is directly related to safety and reliability for the running of Maglev. However, most the third-rail system used in Korea depend on foreign product or technologies, Korea Urban Maglev in the development of appropriate power feeding is urgent. In particular, the turnout section is the weakness point in the system because bending force by turnout section movement and fatigue caused by repetitive motion as well as the expansion by temperature, the forces by Maglev collecting shoe is added th the third-rail. Therefore, this paper proposes the third-rail system appropriate for Korean Urban Maglev of turnout section. To verify the structural stability of POSCO ICT third-rail system, the finite element analysis and physical testing was performed. The third-rail is fixed on each side of the turn-out section steel structure by epoxy insulation supporter and the integral behaviors are occurred. Therefore, the maximum horizontal displacements of each support are investigated and then, it is applied to finite element model of the third-rail to investigate the moments and stress. Also, the bending test about one million times and Expansion Joint for the third-rail was performed. The third-rail system safety and reliability was identified by test line on Korea Institute of Machinery & Materials in Deajeon for under the actual usage environment such as the Maglev and turn-out operation.

  • PDF

허니컴 샌드위치판의 투과손실 개선에 관한 실험적 연구 (An Experimental study to Improving the Sound Transmission Loss of Honeycomb sandwich Plates)

  • 유영훈;양보석
    • 한국자동차공학회논문집
    • /
    • 제6권2호
    • /
    • pp.92-99
    • /
    • 1998
  • The sound insulation capacity of honeycomb sandwich plates which have relatively higher strength ratios to weight is poorer than those of uniform and another sandwich plates. Therefore, improvement of the sound insulation capacity of the honeycomb sandwich plate which has a meritof lightness is required to use it in automobile and rapid rail road industries. In this study, to improving the sound insulation capacity of the honeycomb sandwich plate, the sound transmission loss of the structure is experimentally investigated by adding a viscoelastic damping layer, The effective add position and thickness of the layer were investigated from the viewpoints of both sound transmission loss and improved sound transmission loss over the frequency range from 800Hz to 10kHz.

  • PDF

직류방식 전기철도에서 강제배류기의 절연협조 (Insulation Coordination of Forced Drainage in Electric Railway)

  • 민병훈;어익수
    • 대한전기학회:학술대회논문집
    • /
    • 대한전기학회 1999년도 하계학술대회 논문집 A
    • /
    • pp.446-448
    • /
    • 1999
  • The forced drainage set up to decrease the cathodic protection in each kind of steel conduit laid under the ground is so proscribed to be maintained less than 60V in its output voltage that insulation coordination is easy to be left out of account, on the basis of 60V of working voltage. When railway or subway break down during the service of a subway, 1,500 voltage approximating to line voltage flows through the load terminal of the drainage (rail and underground conduit) though momentary in the worst case. And so, an accident followed by dielectric breakdown, fire and damage by a fire is expected. Therefore, I suggest that insulation coordination should be considered against such a thing on designing, producing and setting up forced drainage.

  • PDF