• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.029 seconds

Quantitative analysis of three dimensional volumetric images in Chest CT (흉부 CT 검사에서 3차원 체적 영상의 정량적 분석)

  • Jang, Hyun-Cheol;Cho, Jae-Hwan;Park, Cheol-Soo
    • Journal of the Korean Society of Radiology
    • /
    • v.5 no.5
    • /
    • pp.255-260
    • /
    • 2011
  • We wanted to evaluate the usefulness of three-dimensional reconstructive images using computed tomography for rib fracture patients. The reconstruction used in clinical multi planar reformation(MPR), volume rendering technique(VRT), and image data using quantitative methods and qualitative methods were compared. Much more, the artifact shadow was minimized to reconstruct with 3D volumetric image by using an law data in the analysis of the reconstructive image and chest CT scan of the evaluation result fractures of the thoracic patient. And we could know that the fractures of the thoracic determination and three dimension volume image reconstruction time were reduced.

Radiological Measurements of Lung Field Size in Normal Korean using Digital Chest Posteroanterior Radiography (디지털 흉부 후·전 방향 방사선영상을 이용한 정상 한국인 폐 크기의 영상의학적 계측)

  • Park, Yeo-Jin;Joo, Young-Cheol;Lee, Il-Soo
    • Journal of radiological science and technology
    • /
    • v.41 no.1
    • /
    • pp.1-6
    • /
    • 2018
  • The purpose of this study is to provide baseline data on lung field size measured radiological method by chest PA image in normal Korean. The subject of this study is 496 normal persons who performed chest PA examination using x-ray digital radiography system. The measurement method is from the apex of right and left lung to the costophrenic angle of both lung, from the top of the image to the lowest costophrenic angle of both lung and transverse line of the largest lung area. As a result of this study, the following conclusions were obtained. A lung field size of male is larger than the female(p<0.05). The younger the age, the longer both lung length and total lung height statistically significant. As a increase height and length, A lung field size was increased(p<0.05). But, BMI is not associated with a lung field size. This study will be data of reference data when radiological technologists perform chest PA examination.

Evaluation of Effects on Tritium Measurement According to HTO Type Sample Preparation Conditions (HTO 형태 시료 조제 조건에 따른 삼중수소 계측에 미치는 영향 평가)

  • An, Eun-Mi;Kim, Jung-Hoon;Lee, Hong-Yeon;Han, Sang-Jun;Kim, Bo-Gil
    • Journal of radiological science and technology
    • /
    • v.44 no.4
    • /
    • pp.381-387
    • /
    • 2021
  • In this study, for the measurement of 3H(tritium) radioactivity concentration, a study was conducted on whether the type of cocktail and the material of the vial had an effect on the measurement before liquid scintillation counter measurement on HTO-type samples that had undergone physical and chemical pretreatment. As a result of the study, the efficiency according to the type of cocktail was higher in Ultima Gold LLT than Ultima Flo-AP cocktail with polyethylene (1.49%), glass (5.10%), and teflon (6.58%), respectively. Regarding the effect according to the type of vial, the efficiency and SQP(E) of both Ultima Gold LLT and Ultima Flo-AP showed the highest values in the order of teflon, polyethylene, and glass.

Dental age estimation using cone-beam computed tomography: A systematic review and meta-analysis

  • Faezeh Yousefi;Younes Mohammadi;Mehrnaz Ahmadvand;Parnian Razaghi
    • Imaging Science in Dentistry
    • /
    • v.53 no.2
    • /
    • pp.91-99
    • /
    • 2023
  • Purpose: This systematic review aimed to investigate the correlation between chronological age and dental pulp volume in cone-beam computed tomography (CBCT). Materials and Methods: The literature was searched in 4 databases(PubMed, Scopus, Web of Science, and Google Scholar). Within each study, the outcome of interest was the correlation (r) between chronological age and pulp volume. A random-effect meta-analysis was conducted. Subgroup analysis was carried out according to sex and tooth type. Results: Of 5,693 identified studies, 27 fulfilled the inclusion criteria and were selected for meta-analysis. These articles focused on single-rooted teeth (n=21), multi-rooted teeth (n=6), maxillary teeth (n=14), mandibular teeth (n=6), and maxillary and mandibular teeth (n=12). The relationship between chronological age and dental pulp volume was examined in the entire population (r= -0.67), men (r= -0.75), and women (r= -0.77) in single- and multi-rooted teeth. The results of the total population analysis showed a relatively strong negative relationship between age and pulp volume. Conclusion: This study suggested that CBCT is a reliable and repeatable tool for dental age estimation. A strong inverse relationship was observed between pulp chamber volume and age. Further studies on the correlation between chronological age and pulp volume of multi-rooted teeth may be beneficial.

Quality Management for Mammography Equipment and Mammography (유방촬영장치와 유방검사를 위한 품질관리)

  • zheng, Hao Yang;Cho, Pyong Kon;Kim, Tae Woo;Kim, Jung Soo;Jang, Hyon Chol;Lee, Mi Hwa
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.683-692
    • /
    • 2018
  • Mammography using mammography equipment is a method of examination that is being employed most widely to diagnose the early stages of breast cancer. Detecting or diagnosing a fibrous tissue, micro calcification, or mass in the breast is influenced by the quality management of mammography equipment considerably. Particularly in mammography, quality management refers to a behavior of figuring out and correcting all sorts of hindrance factors that can cause all the problems related to the equipment associated with the diminishment of diagnosed area due to the reduction of image quality in clinical imaging in advance and maintaining a consistent level of image quality and obtaining a proper image. Here, these researchers aim to summarize and report the general contents of quality management in mammography using mammography equipment.

Diagnostic Value of CYFRA 21-1 Measurement in Fine-Needle Aspiration Washouts for Detection of Axillary Recurrence in Postoperative Breast Cancer Patients (유방암 수술 후 액와림프절 재발 진단에 있어서의 미세침세척액 CYFRA 21-1의 진단적 가치)

  • So Yeon Won;Eun-Kyung Kim;Hee Jung Moon;Jung Hyun Yoon;Vivian Youngjean Park;Min Jung Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.81 no.1
    • /
    • pp.147-156
    • /
    • 2020
  • Purpose The objective of this study was to evaluate the diagnostic value and threshold levels of cytokeratin fragment 21-1 (CYFRA 21-1) in fine-needle aspiration (FNA) washouts for detection of lymph node (LN) recurrence in postoperative breast cancer patients. Materials and Methods FNA cytological assessments and CYFRA 21-1 measurement in FNA washouts were performed for 64 axillary LNs suspicious for recurrence in 64 post-operative breast cancer patients. Final diagnosis was made on the basis of FNA cytology and follow-up data over at least 2 years. The concentration of CYFRA 21-1 was compared between recurrent LNs and benign LNs. Diagnostic performance and cut-off value were evaluated using a receiver operating characteristic curve. Results Regardless of the non-diagnostic results, the median concentration of CYFRA 21-1 in recurrent LNs was significantly higher than that in benign LNs (p < 0.001). The optimal diagnostic cut-off value was 1.6 ng/mL. The sensitivity, specificity, positive predictive value, negative predictive value, and accuracy of CYFRA 21-1 for LN recurrence were 90.9%, 100%, 100%, 98.1%, and 98.4%, respectively. Conclusion Measurement of CYFRA 21-1 concentration from ultrasound-guided FNA biopsy aspirates showed excellent diagnostic performance with a cut-off value of 1.6 ng/mL. These results indicate that measurement of CYFRA 21-1 concentration in FNA washouts is useful for the diagnosis of axillary LN recurrence in post-operative breast cancer patients.

Utility of the 16-cm Axial Volume Scan Technique for Coronary Artery Calcium Scoring on Non-Enhanced Chest CT: A Prospective Pilot Study (비 조영증강 흉부 CT에서 관상동맥 칼슘스코어 측정을 위한 16 cm 축상 촬영 기법의 유용성: 전향적 탐색적 연구)

  • So Jung Ki;Chul Hwan Park;Kyunghwa Han;Jae Min Shin;Ji Young Kim;Tae Hoon Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.82 no.6
    • /
    • pp.1493-1504
    • /
    • 2021
  • Purpose This study aimed to evaluate the utility of the 16-cm axial volume scan technique for calculating the coronary artery calcium score (CACS) using non-enhanced chest CT. Materials and Methods This study prospectively enrolled 20 participants who underwent both, non-enhanced chest CT (16-cm-coverage axial volume scan technique) and calcium-score CT, with the same parameters, differing only in slice thickness (in non-enhanced chest CT = 0.625, 1.25, 2.5 mm; in calcium score CT = 2.5 mm). The CACS was calculated using the conventional Agatston method. The difference between the CACS obtained from the two CT scans was compared, and the degree of agreement for the clinical significance of the CACS was confirmed through sectional analysis. Each calcified lesion was classified by location and size, and a one-to-one comparison of non-contrast-enhanced chest CT and calcium score CT was performed. Results The correlation coefficients of the CACS obtained from the two CT scans for slice thickness of 2.5, 1.25, and 0.625 mm were 0.9850, 0.9688, and 0.9834, respectively. The mean differences between the CACS were -21.4% at 0.625 mm, -39.4% at 1.25 mm, and -76.2% at 2.5 mm slice thicknesses. Sectional analysis revealed that 16 (80%), 16 (80%), and 13 (65%) patients showed agreement for the degree of coronary artery disease at each slice interval, respectively. Inter-reader agreement was high for each slice interval. The 0.625 mm CT showed the highest sensitivity for detecting calcified lesions. Conclusion The values in the non-contrast-enhanced chest CT, using the 16-cm axial volume scan technique, were similar to those obtained using the CACS in the calcium score CT, at 0.625 mm slice thickness without electrocardiogram gating. This can ultimately help predict cardiovascular risk without additional radiation exposure.

Benign Adenomyoepithelioma of the Breast: Imaging Characteristics (유방의 양성 선근상피세포종: 영상 특징)

  • So Ra Shin;Eun Young Ko;Boo-Kyung Han;Eun Sook Ko;Ji Soo Choi;Haejung Kim
    • Journal of the Korean Society of Radiology
    • /
    • v.84 no.2
    • /
    • pp.398-408
    • /
    • 2023
  • Purpose This study aimed to evaluate the radiological and clinical characteristics of benign adenomyoepitheliomas of the breast. Materials and Methods Over the last 20 years, 120 patients were histologically diagnosed with breast adenomyoepithelioma (AME) at our institution. We excluded 43 patients who were incidentally diagnosed during mastectomy for breast cancer, 28 who underwent percutaneous biopsy without further excision, and 8 who had biopsy-confirmed benign AME and were found to have another pathology after complete excision. We retrospectively reviewed the clinical records and radiological findings of the remaining 41 patients with histologically diagnosed benign breast AMEs after complete excision. Results All 41 patients underwent US; 38 underwent mammography (MG) and US; and 18 underwent MG, US, and MRI. MG detected 38 cases with a round or oval shape (56%), and mass (89%), were non-circumscribed (62%), hyperdense (53%), and without microcalcifications (95%). Breast US revealed suspicious masses (98%) with a non-circumscribed margin (66%), hypoechogenicity (43%), and intratumoral vascularity (63%). All lesions on breast MRI showed suspicious masses (100%) with ill-defined margins (61%), and 84% showed wash-out kinetics. Benign AMEs showed suspicious features of Breast Imaging Reporting and Data System (BI-RADS) category 4 or 5 in 83%-95% of the MG, US, and MRI. Sixteen of the 41 cases were misdiagnosed on the initial core needle biopsy and two were diagnosed as malignancy. Conclusion Benign breast AME often shows suspicious radiological features mimicking a malignant mass on MG, US, and MRI. Differentiating benign AME from other pathologies might be difficult on core needle biopsy, and complete excision is needed for a correct diagnosis.

Relationship of Clinical Thinking Disposition and Satisfaction of Clinical Practice in Radiology Students (방사선학과 대학생의 비판적 사고성향과 임상실습 만족도와의 관련성)

  • Kwon, Soon-Mu;Chon, Kwon-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.3
    • /
    • pp.359-366
    • /
    • 2018
  • This study was conducted to identify the relationship between critical thinking disposition and satisfaction of clinical practice in radiology students. The participants were 187 radiology students who were experienced clinical practice. Data was collected from December 1 to 15, 2017 using self-report questionnaires and analyzed through descriptive statistics, t-test, ANOVA and Pearson correlation coefficient with SPSS 16.0. Critical thinking disposition and satisfaction of clinical practice averaged 3.68 and 3.59. Significant positive correlation between Critical thinking disposition and satisfaction of clinical practice were found(r=.522, p<.01). Therefore it is necessary to strengthen critical thinking disposition and satisfaction of clinical practice through effective radiology educational program.

Size-Specific Dose Estimation In the Korean Lung Cancer Screening Project: Does a 32-cm Diameter Phantom Represent a Standard-Sized Patient in Korean Population?

  • Kim, Eun Young;Kim, Tae Jung;Goo, Jin Mo;Kim, Hyae Young;Lee, Ji Won;Lee, Soojung;Lim, Jun-tae;Kim, Yeol
    • Korean Journal of Radiology
    • /
    • v.19 no.6
    • /
    • pp.1179-1186
    • /
    • 2018
  • Objective: The purposes of this study were to evaluate size-specific dose estimate (SSDE) of low-dose CT (LDCT) in the Korean Lung Cancer Screening (K-LUCAS) project and to determine whether CT protocols from Western countries are appropriate for lung cancer screening in Korea. Materials and Methods: For participants (n = 256, four institutions) of K-LUCAS pilot study, volume CT dose index ($CTDI_{vol}$) using a 32-cm diameter reference phantom was compared with SSDE, which was recalculated from $CTDI_{vol}$ using size-dependent conversion factor (f-size) based on the body size, as described in the American Association of Physicists in Medicine Report 204. This comparison was subsequently assessed by body mass index (BMI) levels (underweight/normal vs. overweight/obese), and automatic exposure control (AEC) adaptation (yes/no). Results: Size-specific dose estimate was higher than $CTDI_{vol}$ ($2.22{\pm}0.75mGy$ vs. $1.67{\pm}0.60mGy$, p < 0.001), since the f-size was larger than 1.0 for all participants. The ratio of SSDE to $CTDI_{vol}$ was higher in lower BMI groups; 1.26, 1.37, 1.43, and 1.53 in the obese (n = 103), overweight (n = 70), normal (n = 75), and underweight (n = 4), respectively. The ratio of SSDE to $CTDI_{vol}$ was greater in standard-sized participants than in large-sized participants independent of AEC adaptation; with AEC, SSDE/$CTDI_{vol}$ in large- vs. standard-sized participants: $1.30{\pm}0.08$ vs. $1.44{\pm}0.08$ (p < 0.001) and without AEC, $1.32{\pm}0.08$ vs. $1.42{\pm}0.06$ (p < 0.001). Conclusion: Volume CT dose index based on a reference phantom underestimates radiation exposure of LDCT in standard-sized Korean participants. The optimal radiation dose limit needs to be verified for standard-sized Korean participants.