• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.027 seconds

Diagnostic accuracy of artificially induced vertical root fractures: a comparison of direct digital periapical images with conventional periapical images

  • Lee Ji-Un;Kwon Ki-Jeong;Koh Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • v.34 no.4
    • /
    • pp.185-190
    • /
    • 2004
  • Purpose: To compare the diagnostic accuracy for the detection of root fractures in CMOS-based digital periapical images with conventional film-based periapical images. Materials and Methods: Sixty extracted single-root human teeth with closed apices were prepared endodontically and divided into two groups; artificially induced vertical root fracture group and control group. All radiographs were obtained using the paralleling technique. The radiographs were examined by 4 observers three times within a 4 week interval. Receiver operating characteristic (ROC) analysis was carried out using data obtained from four observers. Intra- and inter-examiner agreements were computed using kappa analysis. Results: The area under the ROC curve (Az) was used as an indicator of the diagnostic accuracy of the imaging system. Az values were as follows: direct-digital images; 0.93, film-based images; 0.92, and inverted digital images; 0.91. There was no significant difference between imaging modalities (P<0.05). The kappa value of inter-observer agreement was 0.42 (range: 0.28-0.60) and intra-observer agreement was 0.57 (range: 0.44-0.75). Conclusion : There is no statistical difference in diagnostic accuracy for the detection of vertical root fractures between digital periapical images and conventional periapical images. The results indicate that the CMOS sensor is a good image detector for the evaluation of vertical root fractures.

  • PDF

Effects of 2-deoxy-D-glucose and quercetin on the expression of osteonectin and osteopontin during the differentiation of irradiated MC3T3-El osteoblastic cells

  • Yu, Su-Kyoung;Koh, Kwang-Joon;Kim, Kyoung-A
    • Imaging Science in Dentistry
    • /
    • v.38 no.4
    • /
    • pp.195-202
    • /
    • 2008
  • Purpose : To characterize the effects of 2-deoxy-D-glucose (2-DG) and quercetin (QCT) on gene expression of osteonectin (ON) and osteopontin (OP) in irradiated MC3T3-El cells. Materials and Methods : When MC3T3-El osteoblastic cells had reached 70-80% confluence, cultures were transferred to a differentiating medium supplemented with 5 mM 2-DG or 10 ${\mu}M$ QCT and then irradiated with 2, 4, 6, and 8 Gy. At various times after irradiation, the cells were analyzed for the expression of bone mineralization genes such as ON and OP. Results : The mRNA expression of both ON and OP was increased according to the culture time in the differentiation medium, and the increase of the genes peaked at 14 days after the differentiation induction. In the case of OP, the increase of mRNA expression was maintained to 28 days after the differentiation, while the mRNA level of ON was reduced to the basal level at the same time. Irradiation adding 2-DG showed a significant peak value in the expression pattern of ON at 4 Gy 7 days after irradiation. Irradiation adding QCT increased the mRNA expression of ON and OP in a dose-dependant manner, but irradiation adding 2-DG did not show any differences between the control and experiments 14 days after irradiation. Irradiation adding QCT increased significantly the expression patterns of ON 21 days after irradiation. Conclusion : The results showed that QCT acted as a radiosensitizer in the gene expression of ON and OP during differentiation of the late stage of irradiated MC3T3-E1 osteoblastic cells in vitro. (Korean J Oral Maxillofac Radiol 2008; 38: 195-202)

  • PDF

Prediction of age-related osteoporosis using fractal analysis on panoramic radiographs

  • Koh, Kwang-Joon;Park, Ha-Na;Kim, Kyoung-A
    • Imaging Science in Dentistry
    • /
    • v.42 no.4
    • /
    • pp.231-235
    • /
    • 2012
  • Purpose: This study was performed to evaluate the trabecular pattern on panoramic radiographs to predict age-related osteoporosis in postmenopausal women. Materials and Methods: Thirty-one postmenopausal osteoporotic women and 25 postmenopausal healthy women between the ages of 50 and 88 were enrolled in this study. The bone mineral density (BMD) of the lumbar vertebrae and femur were calculated using dual-energy X-ray absorptiometry (DXA), and panoramic radiographs were obtained. Fractal dimension (FD) was measured using the box counting method from 560 regions of interest ($51{\times}51$ pixels) in 6 sites on the panoramic radiographs. The relationships between age and BMD and between FD and BMD were assessed, and the intraobserver agreement was determined. Results: There was a significant difference in the FD values between the osteoporotic and normal groups (p<0.05). There was a significant difference in the FD values at three sites in the jaws (p<0.05). Age was significantly correlated with the BMD measurements, with an odds ratio of 1.25. However, the FD values were not significantly correlated with the BMD measurements, with an odds ratio of 0.000. The intraobserver agreement showed relatively higher correlation coefficients at the upper premolar, lower premolar, and lower anterior regions than the other sites. Conclusion: Age was an important risk factor for predicting the presence of osteoporosis in postmenopausal women. The lower premolar region was the most appropriate site for evaluating the FD value on panoramic radiographs. However, further investigation might be needed to predict osteoporosis using an FD value on panoramic radiographs.

Radiological study of the mandibular fractures (하악골 골절에 관한 방사선학적 연구)

  • Kim, Ju-Won;Kim, Kyoung-A;Koh, Kwang-Joon
    • Imaging Science in Dentistry
    • /
    • v.39 no.2
    • /
    • pp.93-98
    • /
    • 2009
  • Purpose: To classify and evaluate the mandibular fractures. Materials and Methods : The author classified the mandibular fractures of 284 patients who were referred to the Chonbuk National University Dental Hospital during the period from March 2004 to June 2007. This study was based on the conventional radiographs as well as computed tomographs which were pertained to the 284 patients who have had the mandibular fractures including the facial bone fractures. And mandibular fractures were classified with respect to gender, age, site and type of the fractures. Results: More frequently affected gender with mandibular fracture was male with the ratio of 3.3:1. The most frequently affected age with mandibular fracture was third decade (38%), followed by fourth decade (16%), second decade (15%), fifth decade (11 %), sixth decade (7%), seventh decade (5%), eighth decade (4%), first decade (4%), and ninth decade (0.3%). The most frequent type of mandibular fracture was single fracture (58%), followed by double fracture (39%), triple fracture (3%). The most common site of mandibular fracture was mandibular condyle as 113 cases (27.7%) and the next was mandibular symphysis as 109 cases (26.7%), mandibular angle as 103 cases (25.3%), mandibular body as 83 cases (20.3%) in order. The sum of fracture sites were 408 sites and there were 1.4 fracture sites per one patient. The number of mandible fractures accompanied with facial bone fractures were 41 cases (14.4%). Conclusion: The results showed the most frequent type and common site of mandibular fracture was single fracture and mandibular condyle respectively. (Korean J Oral Maxillofac Radiol 2009; 39: 93-8)

  • PDF

Three dimensional evaluation of impacted mesiodens using dental cone beam CT (치과용 콘빔 CT를 이용한 상악 정중과잉치의 3차원 분석)

  • Lee, Dong-Ho;Lee, Jea-Seo;Yoon, Suk-Ja;Kang, Byung-Cheol
    • Imaging Science in Dentistry
    • /
    • v.40 no.3
    • /
    • pp.109-114
    • /
    • 2010
  • Purpose : This study was performed to analyze the position, pattern of impacted mesiodens, and their relationship to the adjacent teeth using Dental cone-beam CT. Materials and Methods : Sixty-two dental cone-beam CT images with 81 impacted mesiodenses were selected from about 2,298 cone-beam CT images at Chonnam National University Dental Hospital from June 2006 to March 2009. The position, pattern, shape of impacted mesiodenses and their complications were analyzed in cone-beam CT including 3D images. Results : The sex ratio (M : F) was 2.9 : 1. Most of the mesiodenses (87.7%) were located at palatal side to the incisors. 79% of the mesiodenses were conical in shape. 60.5% of the mesiodenses were inverted, 21% normal erupting direction, and 18.5% transverse direction. The complications due to the presence of mesiodenses were none in 43.5%, diastema in 19.4%, tooth displacement in 17.7%, delayed eruption or impaction in 12.9%, tooth rotation in 4.8%, and dentigerous cyst in 1.7%. Conclusions : Dental cone-beam CT images with 3D provided 3-dimensional perception of mesiodens to the neighboring teeth. This results would be helpful for management of the impacted mesiodens.

Effect of Total Remote Classes on Lecture Satisfaction due to Coronavirus disease-19: Focusing on Radiological Science Majors (코로나바이러스감염증-19로 인한 전면적 원격수업이 강의만족도에 미치는 영향: 방사선학 전공자를 중심으로)

  • Hwang, Chulhwan;Yang, Sung Hee;Koo, Hyo Geun
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.3
    • /
    • pp.381-390
    • /
    • 2021
  • The purpose of this study was to examine the lecture satisfaction of radiological science majors in total remote classes due to coronavirus disease 2019, and influencing factors were analyzed. An online survey was conducted from September 1, 2020 to November 15, 2020, lecture satisfaction, teaching presence, academic motivation, self efficacy, behavior regulation and usage simplicity of remote classes for 458 3 and 4-year radiological science majors located in the Yeongnam area. Lecture satisfaction was significantly different according to grade, self-review time, and preferred teaching method. In addition, lecture satisfaction showed a significant positive corrleation with the teaching presence and usage simplicity of remote classes. In the multiple regression model, lecture satisfaction showed a significant explanatory power of 45.7% through usage simplicity, teaching presence, self efficacy and academic motivation. This study was attempted to provide basic data to increase the effect of remote classes at universities that are expected to expand in the post-corona.

Radiology Residents' Independent Diagnosis of Appendicitis Using 2-mSv Computed Tomography: A Secondary Analysis of a Large Pragmatic Randomized Trial

  • Jungheum Cho;Hae Young Kim;Seungjae Lee;Ji Hoon Park;Kyoung Ho Lee
    • Korean Journal of Radiology
    • /
    • v.24 no.6
    • /
    • pp.529-540
    • /
    • 2023
  • Objective: To compare the diagnostic performance and clinical outcomes of 2-mSv computed tomography (CT) and conventional-dose CT (CDCT), following radiology residents' interpretation of CT examinations for suspected appendicitis. Materials and Methods: Altogether, 3074 patients with suspected appendicitis aged 15-44 years (28 ± 9 years, 1672 females) from 20 hospitals were randomly assigned to the 2-mSv CT (n = 1535) or CDCT (n = 1539) groups in a pragmatic trial from December 2013 and August 2016. Overall, 107 radiology residents participated in the trial as readers in the form of daily practice after online training for 2-mSv CT. They made preliminary CT reports, which were later finalized by attending radiologists via addendum reports, for 640 and 657 patients in the 2-mSv CT and CDCT groups, respectively. We compared the diagnostic performance of the residents, discrepancies between preliminary and addendum reports, and clinical outcomes between the two groups. Results: Patient characteristics were similar between the 640 and 657 patients. Residents' diagnostic performance was not significantly different between the 2-mSv CT and CDCT groups, with a sensitivity of 96.0% and 97.1%, respectively (difference [95% confidence interval {CI}], -1.1% [-4.9%, 2.6%]; P = 0.69) and specificity of 93.2% and 93.1%, respectively (0.1% [-3.6%, 3.7%]; P > 0.99). The 2-mSv CT and CDCT groups did not significantly differ in discrepancies between the preliminary and addendum reports regarding the presence of appendicitis (3.3% vs. 5.2%; -1.9% [-4.2%, 0.4%]; P = 0.12) and alternative diagnosis (5.5% vs. 6.4%; -0.9% [-3.6%, 1.8%]; P = 0.56). The rates of perforated appendicitis (12.0% vs. 12.6%; -0.6% [-4.3%, 3.1%]; P = 0.81) and negative appendectomies (1.9% vs. 1.1%; 0.8% [-0.7%, 2.3%]; P = 0.33) were not significantly different between the two groups. Conclusion: Diagnostic performance and clinical outcomes were not significantly different between the 2-mSv CT and CDCT groups following radiology residents' CT readings for suspected appendicitis.

The Pathology of Infection in the Department of Radiology (영상의학과 검사실의 감염 실태)

  • Shin, Seong-Gyu;Lee, Hyo-Yeong
    • Journal of radiological science and technology
    • /
    • v.35 no.3
    • /
    • pp.211-218
    • /
    • 2012
  • This study was performed to understand the bacteriologic contamination level of radiological equipments which have frequent contacts with patients in the Department of Radiology of an university hospital in Busan area. Before sterilizing in-patient of the radiology rooms, MRSA, VRE, acinetobacter baumannii, candida albicans, and enterococcus sp. were detected. After sterilization, all the bacteria were not found. As examine times become longer, more bacteria were detected and after 7 hours, bacillus sp.(GPR), CNS, acinetobacter baumannii, and Enterococcus sp. were detected. After examining infected patients, bacillus sp.(GPR), VRE, enterococcus sp. CNS, and micrococcus sp. were detected and on the hands of radiological technologists, CNS, enterococcus sp. escherichia coli, and enterobacter sp. were detected. Similar species of bacteria were detected from each radiology room, but pseudomonas aeruginosa was detected on the handles of portable radiological equipments and the chair in the waiting room. Therefore, it is the most important to regularly sterilize radiological equipments and devices which have frequent contacts with patients and to sterilize them right after the use of infected patients in order to prevent the spread of infection. Also, thorough hand washing, education on infection and management for the characteristics of Department of Radiology should be performed for the systematic prevention of infection.

Myocardial Blood Flow Quantified by Low-Dose Dynamic CT Myocardial Perfusion Imaging Is Associated with Peak Troponin Level and Impaired Left Ventricle Function in Patients with ST-Elevated Myocardial Infarction

  • Jingwei Pan;Mingyuan Yuan;Mengmeng Yu;Yajie Gao;Chengxing Shen;Yining Wang;Bin Lu;Jiayin Zhang
    • Korean Journal of Radiology
    • /
    • v.20 no.5
    • /
    • pp.709-718
    • /
    • 2019
  • Objective: To investigate the association of myocardial blood flow (MBF) quantified by dynamic computed tomography (CT) myocardial perfusion imaging (MPI) with troponin level and left ventricle (LV) function in patients with ST-segment elevated myocardial infarction (STEMI). Materials and Methods: Thirty-five STEMI patients who successfully had undergone reperfusion treatment within 1 week of their infarction were consecutively enrolled. All patients were referred for dynamic CT-MPI. Serial high-sensitivity troponin T (hs-TnT) levels and left ventricular ejection fraction (LVEF) measured by echocardiography were recorded. Twenty-six patients with 427 segments were included for analysis. Various quantitative parameters derived from dynamic CT-MPI were analyzed to determine if there was a correlation between hs-TnT levels and LVEF on admission and again at the 6-month mark. Results: The mean radiation dose for dynamic CT-MPI was 3.2 ± 1.1 mSv. Infarcted territories had significantly lower MBF (30.5 ± 7.4 mL/min/100 mL versus 73.4 ± 8.1 mL/min/100 mL, p < 0.001) and myocardial blood volume (MBV) (2.8 ± 0.9 mL/100 mL versus 4.2 ± 1.1 mL/100 mL, p = 0.044) compared with those of reference territories. MBF showed the best correlation with the level of peak hs-TnT (r = -0.682, p < 0.001), and MBV showed a moderate correlation with the level of peak hs-TnT (r = -0.437, p = 0.026); however, the other parameters did not show any significant correlation with hs-TnT levels. As for the association with LV function, only MBF was significantly correlated with LVEF at the time of admission (r = 0.469, p = 0.016) and at 6 months (r = 0.585, p = 0.001). Conclusion: MBF quantified by dynamic CT-MPI is significantly inversely correlated with the level of peak hs-TnT. In addition, patients with lower MBF tended to have impaired LV function at the time of their admission and at 6 months.

T2 Mapping with and without Fat-Suppression to Predict Treatment Response to Intravenous Glucocorticoid Therapy for Thyroid-Associated Ophthalmopathy

  • Linhan Zhai;Qiuxia Wang;Ping Liu;Ban Luo;Gang Yuan;Jing Zhang
    • Korean Journal of Radiology
    • /
    • v.23 no.6
    • /
    • pp.664-673
    • /
    • 2022
  • Objective: To evaluate the performance of baseline clinical characteristics and pretherapeutic histogram parameters derived from T2 mapping of the extraocular muscles (EOMs) in the prediction of treatment response to intravenous glucocorticoid (IVGC) therapy for active and moderate-to-severe thyroid-associated ophthalmopathy (TAO) and to investigate the effect of fat-suppression (FS) in T2 mapping in this prediction. Materials and Methods: A total of 79 patients clinically diagnosed with active, moderate-to-severe TAO (47 female, 32 male; mean age ± standard deviation, 46.1 ± 10 years), including 43 patients with a total of 86 orbits in the responsive group and 36 patients with a total of 72 orbits in the unresponsive group, were enrolled. Baseline clinical characteristics and pretherapeutic histogram parameters derived from T2 mapping with FS (i.e., FS T2 mapping) or without FS (i.e., conventional T2 mapping) of EOMs were compared between the two groups. Independent predictors of treatment response to IVGC were identified using multivariable analysis. Receiver operating characteristic (ROC) curve analysis was performed to evaluate the predictive performance of the prediction models. Differences between the models were examined using the DeLong test. Results: Compared to the unresponsive group, the responsive group had a shorter disease duration, lower kurtosis (FS-kurtosis), lower standard deviation, larger 75th, 90th, and 95th (FS-95th) T2 relaxation times in FS mapping and lower kurtosis in conventional T2 mapping. Multivariable analysis revealed that disease duration, FS-95th percentile, and FS-kurtosis were independent predictors of treatment response. The combined model, integrating all identified predictors, had an optimized area under the ROC curve of 0.797, 88.4% sensitivity, and 62.5% specificity, which were significantly superior to those of the imaging model (p = 0.013). Conclusion: An integrated combination of disease duration, FS-95th percentile, and FS-kurtosis was a potential predictor of treatment response to IVGC in patients with active and moderate-to-severe TAO. FS T2 mapping was superior to conventional T2 mapping in terms of prediction.