• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.05 seconds

The Study of a Diagnostic Algorithm for the Quantitative Evaluation of Stress Urinary Incontinence (복압성 요실금의 정량적 평가를 위한 진단 알고리즘에 관한 연구)

  • Min, Hae Ki;Kim, Ju Young;Noh, Si Cheol;Choi, Heung Ho
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.2
    • /
    • pp.277-287
    • /
    • 2018
  • Pelvic floor muscle is the main sub-system that maintains urinary continence. The weakness of pelvic floor muscles causes the stress urinary incontinence, and therefore the degree of functioning of pelvic floor muscles could be used as an index to assess the degree of stress urinary incontinence. In this study, the quantitative diagnosis algorithm was proposed to estimate the degree of stress urinary incontinence (SUI) by measuring the contraction pressure of pelvic floor muscle. For these reason, the contraction pressure measurement system from pelvic floor muscle was developed, and the measuring protocol was suggested to analysis the obtained data. As the results of clinical test, the proposed diagnosis algorithm shows the 80% of accuracy, and 20% of false positive diagnosis. On the other hand, false negative results were not confirmed. Consequentially, we thought that the proposed urinary incontinence diagnosis algorithm can quantitatively diagnose the progression of the stress urinary incontinence and it can be used for the development of the incontinence diagnosis system.

Local Residents' Perception Analysis of Nuclear Power after the Thyroid Cancer Damage Lawsuit Adjacent to the Nuclear Plant (원전주변 갑상선암 발병 피해 소송 사건 이후 원자력에 대한 지역주민 인식 분석)

  • Lee, Jae-Heon;Kim, Jung-Hoon
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.8
    • /
    • pp.583-590
    • /
    • 2016
  • The subjects in this study are the residents of Busan, analyzing the perception gap between the residents adjacent to the nuclear plant and living in town, about the lawsuit of thyroid cancer damage nearby the nuclear plant, to distinguish the citizen's acceptance level about the nuclear power. 551 people(269 people adjacent to nuclear plant, 282 people in town) were face-to-face surveyed and the result showed that people's perceptions of the nuclear power has changed after the thyroid cancer damage lawsuit. In the case of the residents adjacent to the nuclear plant, it became clear that the negative perception of nuclear power became stronger due to increasing distrust and anxiety about nuclear power after the lawsuit of thyroid cancer damage nearby the nuclear plant. On the other hand, people living in town showed their positive perceptions of nuclear power despite the thyroid cancer damage lawsuit. However, two-sided perception was shown compared to the acceptance of nuclear power, since the safety and reliability of the nuclear power was analyzed as negative perception. Therefore, for the constant increased use of nuclear power in the future, national understanding and credibility, including the communication with the nation or the residents in the neighboring area of nuclear power plant, will be necessary.

Diagnosis of Chronic Kidney Disease using Sonography (초음파 영상을 이용한 만성 콩팥병의 진단)

  • Ahn, Yu-Ji;Ye, Soo-Young
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.3
    • /
    • pp.153-159
    • /
    • 2017
  • Chronic kidney disease can be treated if it is detected early, but as the disease progresses, it becomes impossible to recover. Finally, renal replacement therapy such as transplantation or dialysis should be used. Ultrasonography is used to diagnose kidney cancer, inflammatory disease, nodular disease, and chronic kidney disease. It is used to identify information about degree of inflammation using information such as kidney size, internal echo characteristics. Currently, the degree of disease in the clinic uses the value of glomerular filtration rate. However, even in ultrasound, changes in the degree of inflammation and disease can be observed. In this study, we used ultrasound images to quantify the changes in brightness, size, cortex, and subclinical changes of the kidney with progression of the disease, and compared them with the glomerular filtration rate used in clinical practice. In 105 cases, we performed 35 cases of normal kidney, 35 cases of early kidney disease, and 35 cases of terminal kidney. The brightness of the cortex of the image was obtained and the difference in brightness between the cortex and the proximal portion was obtained by the slope. The graph of the portion which was not smooth due to the ultrasonic characteristics was used as the function regrass. The size reduction was obtained from the original data. The results were as follows: It was proportional to the glomerular filtration rate. It is considered that the algorithm can be applied to the disease if the algorithm study continues.

The Study of Dosimetry according to the Thickness of Beam Spoiler on Total Body Irradiation (전신방사선치료시 산란체의 두께에 따른 선량측정)

  • Kim, Youngjae;Jeon, Byeongkyou;Lee, Jaesik;Jung, Jaeeun
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.5
    • /
    • pp.265-269
    • /
    • 2014
  • The therapy of total body irradiation on leukemia carries out to kill harmful bacteria or suppression of immune system by external beam therapy, which is a preparatory stage to reconstitute bone marrow before a pre-treatment of bone marrow transplantation to patients with health bone marrow cells. In case of this kind of radiation therapy, the spoiler use to increase surface dose of patient which varies depending on distance and thickness between patient and spoiler. In this study, the change was investigated the surface dose according to thickness of spoiler. The 0.5% increase of surface dose was observed with each 2.0 cm when the spioler in acrylic was prepared from 0.5 cm to 3.0 cm at intervals of 0.5 cm was evaluated. Based on this result, it suggests that this kind of application will be somewhat limited on clinical trials directly but proper surface dose can be useful method when is applied on patients of treatment prognosis who are required each different surface dose.

Influence of Social Support for a Cancer Patient undergoing Radiation Treatment on Quality of Life (방사선치료중인 암환자의 사회적 지지가 삶의 질에 미치는 영향)

  • Kim, Sunggil;Ruy, Soyeon
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.3
    • /
    • pp.145-152
    • /
    • 2016
  • This study, targeting a cancer patient undergoing radiation treatment, conducted this research with the aim of looking into the relevance between family support belonging to a patient's primary environment, social support consisting of medical personnel, and the quality of life; this study set 199 patients available for investigation from Jan. 25, 2012 until April 30, 2012 as research subjects among the cancer patients undergoing radiation treatment at the Radiation Oncology Department of a university hospital located in Seoul Metropolitan City. In the analysis of collected data, this study conducted t-test using SPSS/WIN 18.0 Statistical Program, and looked into the relevancy between independent variables including social support, and the quality of life as a dependent variable using analysis of variance, correlation analysis and multi-regression analysis. Conclusively, it was found that the higher the family support perceived by a cancer patient undergoing radiation treatment, the higher the quality of his/her life; thus, this study could learn that there exists a significant relation between family support and the quality of life. Accordingly, it is thought that it's necessary to develop an intervention strategy which makes it possible to intensify family support and social support, etc. for the purpose of improving the quality of life of cancer patients undergoing radiation treatment; further, this study thinks that it's necessary to do additional research which could analyze diverse aspects by subdividing the future quality of life by area.

Evaluation of Image Quality for Compressed SENSE(CS) Method in Cerebrovascular MRI: Comparison with SENSE Method (뇌혈관자기공영영상에서 Compressed SENSE(CS) 기법에 대한 영상의 질 평가: SENSE 기법과 비교)

  • Goo, Eun-Hoe
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.7
    • /
    • pp.999-1005
    • /
    • 2021
  • The object of this research is CS, which increases resolution while shortening inspection time, is applied to MRA to compare the quality of images for SENSE and CS techniques and to evaluate SNR and CNR to find out the optimal techniques and to provide them as clinical basic data based on this information. Data were analyzed on 32 patients who performed TOF MRA tests at a university hospital in Chung cheong-do (15 males, 17 females), ICA stenosis:10, M1 Aneurysm:10, and average age 53 ± 4.15). In the inspection, the inspection equipment was Ingenia CX 3.0T, Archieva 3.0T, and 32 channel head coil and 3D gradient echo as a method for equipment data. SNR and CNR of each image were measured by quantitative analysis, and the quality of the image was evaluated by dividing the observer's observation into 5 grades for qualitative evaluation. Imaging evaluation is described as being significant when the p-value is 0.05 or less when the paired T-test and Wilcoxon test are performed. Quantitative analysis of SNR and CNR in TOF MRA images Compared to the SENSE method, the CS method is a method measurement method (p <0.05). As an observer's evaluation, the sharpness of blood vessels: CS (4.45 ± 0.41), overall image quality: CS (4.77 ± 0.18), background suppression of images: CS (4.57 ± 0.18) all resulted in high CS technique (p = 0.000). In conclusion, the Compressed SENSE TOF MRA technique shows superior results when comparing and evaluating the SENSE and Compressed SENSE techniques in increased flow rate magnetic resonance angiography. The results are thought to be the clinical basis material in the 3D TOF MRA examination for brain disease.

Measurement of CT Numbers for Effective Atomic Number And Physical Density of Compound (화합물의 물리적 밀도와 유효원자번호에 대한 CT수 측정)

  • Kim, Jong Eon
    • Journal of the Korean Society of Radiology
    • /
    • v.15 no.2
    • /
    • pp.125-130
    • /
    • 2021
  • In the AAPM CT performance phantom, there is little data on the CT number of the effective atomic number and physical density corresponding to each peg and water of the CT number calibration insert. Therefore, the necessity of documentation was raised.The purpose of this study is to calculate the effective atomic number for each peg and water of the CT number calibration insert in the AAPM CT performance phantom, and to measure the CT number for the calculated effective atomic number and physical density for comparative analysis.In order to obtain CT number data on the effective atomic number and physical density of each peg and water from the CT number calibration insert of the AAPM CT performance phantom, the effective atomic number for each peg and water was first calculated. Then, CT slices were obtained by scanning the CT number calibration with a CT scanner. CT numbers were measured for each peg and water in the central CT slice. As a result, the CT numbers for the effective atomic number showed a nonlinear pattern of repeating the increase and decrease as the effective atomic number increased. In addition, the CT numbers for physical density showed a nonlinear pattern of repeating the increase and decrease as the physical density increased.

MDCT Angiography of the Subclavian Artery Thrombosis of the 3D Findings (쇄골하동맥 혈전증에서의 MDCT 혈관조영술의 3D 영상)

  • Kweon, Dae Cheol
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.813-819
    • /
    • 2018
  • To demonstrate the 3D usefulness of MDCT, a 73-year-old male patient with subclavian thrombosis was obtained 3D images of maximum intensity projection (MIP), volume rendering, and multiplanar reformation (MPR) to clearly detect and locate the subclavian artery. The data will be provided to the patient for diagnosis and treatment. The scan data were acquired as 3D CT images MIP, volume rendering, curved MPR, and virtual endoscopy images. In the 3D program, the ascending aorta was measured as 364.28 HU, the left carotid artery was 413.77 HU, and the left subclavian artery was 15.72 HU. MIP coronal image shows the closure of the subclavian artery in the left side. Three-dimensional volume images were obtained with 100% permeability and 87-1265 HU. The coronal curved MPR and sagittal curved MPR images show the closure of the subclavian artery due to thrombus using 3D image processing. In the case of subclavian arterial occlusion due to thrombosis, the patient is scanned with MDCT and 3D image processing can be used to confirm occlusion of subclavian artery.

Cross Calibration of Dual Energy X-ray Absorptiometry Equipment for Diagnosis of Osteoporosis: between Domestic Manufacturers and Global Manufacturers (골밀도 장치의 교차분석 ; 국내 제조사와 해외 제조사 비교)

  • Kim, Jung-Su
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.7
    • /
    • pp.833-844
    • /
    • 2018
  • Dual energy X-ray absorptiometry is mainly used as an X-ray test method. For equipment manufactured GE and Hologic, cross-calibration analyses (CCA) of machines from the same manufacturer and between units from different manufacturers have been conducted, but the CCA of equipment manufactured in Korea are inadequate. Through CCA, we present a formula of the intersections between the Korean medical equipment company (KEC) with GE and Hologic manufactured DXA, and among the KEC DXA. The CCA was conducted for the European Spine Phantom on DXA from four KEC and three global medical equipment company (GEC) manufacturers. We compared bone mineral density (BMD) values and calculated the CCA equation by linear regression analysis. The standard-deviations (SD) of the BMD values were highest for the Dexxum T for the low, medium, and high spine, which were 0.030, 0.029, and 0.037, respectively. The smallest SD in the low and medium vertebrae were 0.005 and 0.004 for the Horizon Ci, respectively, and 0.005 for the Osteo Pro Max in the high vertebrae. Based on the intersection equations of the KEC DXA established in this study, CCA of various KEC DXA should be established for more accurate follow-up of BMD tests in clinical environments.

Design of Two Layer Depth-encoding Detector Module with SiPM for PET (SiPM을 사용한 두 층의 반응 깊이를 측정하는 양전자방출단층촬영기기의 검출기 모듈 설계)

  • Lee, Seung-Jae
    • Journal of the Korean Society of Radiology
    • /
    • v.13 no.3
    • /
    • pp.319-324
    • /
    • 2019
  • A depth-encoding detector module with silicon photomultipliers(SiPMs) using two layers of scintillation crystal array was designed, and the position measurement capability was verified using DETECT2000. The depth of interaction of the crystal pixels with the gamma rays was tracked through the image acquired with the combination of surface treatment of the crystal pixels and reflectors. The bottom layer was treated as a reflector except for the optically coupled surfaces, and the crystals of top layer were optically coupled each other except for the outer surfaces so that the light sharing was made easier than the bottom layer. Flood images were obtained through the combination of specular reflectors and random reflectors, grounded and polished surfaces of crystal pixels, and the positions at which layer images were generated were measured and analyzed. The images were reconstructed using the Anger algorithm, whose the SiPM signals were reduced as the 16-channels to 4-channels. In the combination of the grounded surface and all reflectors, the depth positions were discriminated into two layers, whereas it was impossible to separate the two layers in the all polished surface combinations. Therefore, using the combination of grounded surface crystal pixels and reflectors could improve the spatial resolution at the outside of the field of view by measuring the depth position in preclinical positron emission tomography.