• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.036 seconds

Survival of surface-modified short versus long implants in complete or partially edentulous patients with a follow-up of 1 year or more: a systematic review and meta-analysis

  • Medikeri, Raghavendra Shrishail;Pereira, Marisca Austin;Waingade, Manjushri;Navale, Shwetambari
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.4
    • /
    • pp.261-281
    • /
    • 2022
  • Purpose: Short implants are a potential alternative to long implants for use with bone augmentation in atrophic jaws. This meta-analysis investigated the survival rate and marginal bone level (MBL) of surface-modified short vs. long implants. Methods: Electronic and manual searches were performed for articles published between January 2010 and June 2021. Twenty-two randomized controlled trials (RCTs) comparing surface-modified short and long implants that reported the survival rate with at least 1 year of follow-up were selected. Two reviewers independently extracted the data, and the risk of bias and quality of evidence were evaluated. A quantitative meta-analysis was performed regarding survival rate and MBL. Results: The failure rates of surface-modified short and long implants differed significantly (risk ratio, 2.28; 95% confidence interval [CI], 1.46, 3.57; P<0.000). Long implants exhibited a higher survival rate than short implants (mean follow-up, 1-10 years). A significant difference was observed in mean MBL (mean difference=-0.43, 95% CI, -0.63, -0.23; P<0.000), favoring the short implants. Regarding the impact of surface treatment in short and long implants, for hydrophilic sandblasted acid-etched (P=0.020) and titanium oxide fluoride-modified (P=0.050) surfaces, the survival rate differed significantly between short and long implants. The MBL differences for novel nanostructured calcium-incorporated, hydrophilic sandblasted acid-etched, and dual acid-etched with nanometer-scale calcium phosphate crystal surfaces (P=0.050, P=0.020, and P<0.000, respectively) differed significantly for short vs. long implants. Conclusions: Short surface-modified implants are a potential alternative to longer implants in atrophic ridges. Long fluoride-modified and hydrophilic sandblasted acid-etched implants have higher survival rates than short implants. Short implants with novel nanostructured calcium-incorporated titanium surfaces, hydrophilic sandblasted acid-etched surfaces, and dual acid-etched surfaces with nanometer-scale calcium phosphate crystals showed less marginal bone loss than longer implants. Due to high heterogeneity, the MBL results should be interpreted cautiously, and better-designed RCTs should be assessed in the future.

Sex determination from lateral cephalometric radiographs using an automated deep learning convolutional neural network

  • Khazaei, Maryam;Mollabashi, Vahid;Khotanlou, Hassan;Farhadian, Maryam
    • Imaging Science in Dentistry
    • /
    • v.52 no.3
    • /
    • pp.239-244
    • /
    • 2022
  • Purpose: Despite the proliferation of numerous morphometric and anthropometric methods for sex identification based on linear, angular, and regional measurements of various parts of the body, these methods are subject to error due to the observer's knowledge and expertise. This study aimed to explore the possibility of automated sex determination using convolutional neural networks(CNNs) based on lateral cephalometric radiographs. Materials and Methods: Lateral cephalometric radiographs of 1,476 Iranian subjects (794 women and 682 men) from 18 to 49 years of age were included. Lateral cephalometric radiographs were considered as a network input and output layer including 2 classes(male and female). Eighty percent of the data was used as a training set and the rest as a test set. Hyperparameter tuning of each network was done after preprocessing and data augmentation steps. The predictive performance of different architectures (DenseNet, ResNet, and VGG) was evaluated based on their accuracy in test sets. Results: The CNN based on the DenseNet121 architecture, with an overall accuracy of 90%, had the best predictive power in sex determination. The prediction accuracy of this model was almost equal for men and women. Furthermore, with all architectures, the use of transfer learning improved predictive performance. Conclusion: The results confirmed that a CNN could predict a person's sex with high accuracy. This prediction was independent of human bias because feature extraction was done automatically. However, for more accurate sex determination on a wider scale, further studies with larger sample sizes are desirable.

Gingival crevicular fluid CSF-1 and IL-34 levels in patients with stage III grade C periodontitis and uncontrolled type 2 diabetes mellitus

  • Ahu Dikilitas;Fatih Karaaslan;Sehrazat Evirgen;Abdullah Seckin Ertugrul
    • Journal of Periodontal and Implant Science
    • /
    • v.52 no.6
    • /
    • pp.455-465
    • /
    • 2022
  • Purpose: Periodontal diseases are inflammatory conditions that alter the host's response to microbial pathogens. Type 2 diabetes mellitus (T2DM) is a complex disease that affects the incidence and severity of periodontal diseases. This study investigated the gingival crevicular fluid (GCF) levels of colony-stimulating factor-1 (CSF-1) and interleukin-34 (IL-34) in patients with stage III grade C periodontitis (SIII-GC-P) and stage III grade C periodontitis with uncontrolled type 2 diabetes (SIII-GC-PD). Methods: In total, 72 individuals, including 24 periodontally healthy (PH), 24 SIII-GC-P, and 24 SIII-GC-PD patients, were recruited for this study. Periodontitis patients (stage III) had interdental attachment loss (AL) of 5 mm or more, probing depth (PD) of 6 mm or more, radiographic bone loss advancing to the middle or apical part of the root, and tooth loss (<5) due to periodontal disease. Radiographic bone loss in the teeth was also evaluated; grade C periodontitis was defined as a ratio of the percentage of root bone loss to age greater than 1.0. The plaque index (PI), gingival index (GI), presence of bleeding on probing (BOP), PD, and clinical AL were used for clinical periodontal assessments. GCF samples were obtained and analyzed using an enzyme-linked immunosorbent assay. Results: All clinical parameters-PD, AL, GI, BOP, and PI-were significantly higher in the SIII-GC-PD group than in the PH and SIII-GC-P groups for both the full mouth and each sampling site (P<0.05). The total IL-34 and CSF-1 levels were significantly higher in the SIII-GC-PD group than in the PH and SIII-GC-P groups (P<0.05), and there were significant differences between the periodontitis groups (P<0.05). Conclusions: These findings suggest that IL-34 and CSF-1 expression increases in patients with SIII-GC-PD. CSF-1 was associated with the inflammatory status of periodontal tissues and T2DM, while IL-34 was associated only with T2DM.

Texture analysis in cone-beam computed tomographic images of medication-related osteonecrosis of the jaw

  • Polyane Mazucatto Queiroz;Karolina Castilho Fardim;Andre Luiz Ferreira Costa;Ricardo Alves Matheus;Sergio Lucio Pereira Castro Lopes
    • Imaging Science in Dentistry
    • /
    • v.53 no.2
    • /
    • pp.109-115
    • /
    • 2023
  • Purpose: The aim of this study was to evaluate changes in the trabecular bone through texture analysis and compare the texture analysis characteristics of different areas in patients with medication-related osteonecrosis of the jaw (MRONJ). Materials and Methods: Cone-beam computed tomographic images of 16 patients diagnosed with MRONJ were used. In sagittal images, 3 regions were chosen: active osteonecrosis(AO); intermediate tissue (IT), which presented a zone of apparently healthy tissue adjacent to the AO area; and healthy bone tissue (HT) (control area). Texture analysis was performed evaluating 7 parameters: secondary angular momentum, contrast, correlation, sum of squares, inverse moment of difference, sum of entropies, and entropy. Data were analyzed using the Kruskal-Wallis test with a significance level of 5%. Results: Comparing the areas of AO, IT, and HT, significant differences (P<0.05) were observed. The IT and AO area images showed higher values for parameters such as contrast, entropy, and secondary angular momentum than the HT area, indicating greater disorder in these tissues. Conclusion: Through texture analysis, changes in the bone pattern could be observed in areas of osteonecrosis. The texture analysis demonstrated that areas visually identified and classified as IT still had necrotic tissue, thereby increasing the accuracy of delimiting the real extension of MRONJ.

Deep-learning performance in identifying and classifying dental implant systems from dental imaging: a systematic review and meta-analysis

  • Akhilanand Chaurasia;Arunkumar Namachivayam;Revan Birke Koca-Unsal;Jae-Hong Lee
    • Journal of Periodontal and Implant Science
    • /
    • v.54 no.1
    • /
    • pp.3-12
    • /
    • 2024
  • Deep learning (DL) offers promising performance in computer vision tasks and is highly suitable for dental image recognition and analysis. We evaluated the accuracy of DL algorithms in identifying and classifying dental implant systems (DISs) using dental imaging. In this systematic review and meta-analysis, we explored the MEDLINE/PubMed, Scopus, Embase, and Google Scholar databases and identified studies published between January 2011 and March 2022. Studies conducted on DL approaches for DIS identification or classification were included, and the accuracy of the DL models was evaluated using panoramic and periapical radiographic images. The quality of the selected studies was assessed using QUADAS-2. This review was registered with PROSPERO (CRDCRD42022309624). From 1,293 identified records, 9 studies were included in this systematic review and meta-analysis. The DL-based implant classification accuracy was no less than 70.75% (95% confidence interval [CI], 65.6%-75.9%) and no higher than 98.19 (95% CI, 97.8%-98.5%). The weighted accuracy was calculated, and the pooled sample size was 46,645, with an overall accuracy of 92.16% (95% CI, 90.8%-93.5%). The risk of bias and applicability concerns were judged as high for most studies, mainly regarding data selection and reference standards. DL models showed high accuracy in identifying and classifying DISs using panoramic and periapical radiographic images. Therefore, DL models are promising prospects for use as decision aids and decision-making tools; however, there are limitations with respect to their application in actual clinical practice.

Distribution of the intraosseous branch of the posterior superior alveolar artery relative to the posterior maxillary teeth

  • Carsen R. McDaniel;Thomas M. Johnson;Brian W. Stancoven;Adam R. Lincicum
    • Imaging Science in Dentistry
    • /
    • v.54 no.2
    • /
    • pp.121-127
    • /
    • 2024
  • Purpose: Preoperative identification of the intraosseous posterior superior alveolar artery (PSAA) is critical when planning sinus surgery. This study was conducted to determine the distance between the cementoenamel junction and the PSAA, as well as to identify factors influencing the detection of the PSAA on cone-beam computed tomography (CBCT). Materials and Methods: In total, 254 CBCT scans of maxillary sinuses, acquired with 2 different scanners, were examined to identify the PSAA. The distance from the cementoenamel junction (CEJ) to the PSAA was recorded at each maxillary posterior tooth position. Binomial logistic regression and multiple linear regression were employed to evaluate the effects of scanner type, CBCT parameters, sex, and age on PSAA detection and CEJ-PSAA distance, respectively. P-values less than 0.05 were considered to indicate statistical significance. Results: The mean CEJ-PSAA distances at the second molar, first molar, second premolar, and first premolar positions were 17.0±4.0 mm, 21.8±4.1 mm, 19.5±4.7 mm, and 19.9±4.9 mm for scanner 1, respectively, and 17.3±3.5 mm, 16.9±4.3 mm, 18.5±4.1 mm, and 18.4±4.3 mm for scanner 2. No independent variable significantly influenced PSAA detection. However, tooth position (b=-0.67, P<0.05) and scanner type (b=-1.3, P<0.05) were significant predictors of CEJ-PSAA distance. Conclusion: CBCT-based estimates of CEJ-PSAA distance were comparable to those obtained in previous studies involving cadavers, CT, and CBCT. The type of CBCT scanner may slightly influence this measurement. No independent variable significantly impacted PSAA detection.

Evaluation of mandibular condyle position in Class III patients after bimaxillary orthognathic surgery: A cone-beam computed tomography study

  • Osman Kucukcakir;Nilufer Ersan;Yunus Ziya Arslan;Erol Cansiz
    • The korean journal of orthodontics
    • /
    • v.54 no.4
    • /
    • pp.247-256
    • /
    • 2024
  • Objective: This retrospective study evaluated the mandibular condyle position before and after bimaxillary orthognathic surgery performed with the mandibular condyle positioned manually in patients with mandibular prognathism using cone-beam computed tomography. Methods: Overall, 88 mandibular condyles from 44 adult patients (20 female and 24 male) diagnosed with mandibular prognathism due to skeletal Class III malocclusion who underwent bilateral sagittal split ramus osteotomy (BSSRO) and Le Fort I performed using the manual condyle positioning method were included. Cone-beam computed tomography images obtained 1-2 weeks before (T0) and approximately 6 months after (T1) surgery were analyzed in three planes using 3D Slicer software. Statistical significance was set at P < 0.05 level. Results: Significant inward rotation of the left mandibular condyle and significant outward rotation of the right mandibular condyle were observed in the axial and coronal planes (P < 0.05). The positions of the right and left condyles in the sagittal plane and the distance between the most medial points of the condyles in the coronal plane did not differ significantly (P > 0.05). Conclusions: While the change in the sagittal plane can be maintained as before surgery with manual positioning during the BSSRO procedure, significant inward and outward rotation was observed in the axial and coronal planes, respectively, even in the absence of concomitant temporomandibular joint disorder before or after the operation. Further long-term studies are needed to correlate these findings with possible clinical consequences.

Efficiency and accuracy of artificial intelligence in the radiographic detection of periodontal bone loss: A systematic review

  • Asmhan Tariq;Fatmah Bin Nakhi;Fatema Salah;Gabass Eltayeb;Ghada Jassem Abdulla;Noor Najim;Salma Ahmed Khedr;Sara Elkerdasy;Natheer Al-Rawi;Sausan Alkawas;Marwan Mohammed;Shishir Ram Shetty
    • Imaging Science in Dentistry
    • /
    • v.53 no.3
    • /
    • pp.193-198
    • /
    • 2023
  • Purpose: Artificial intelligence (AI) is poised to play a major role in medical diagnostics. Periodontal disease is one of the most common oral diseases. The early diagnosis of periodontal disease is essential for effective treatment and a favorable prognosis. This study aimed to assess the effectiveness of AI in diagnosing periodontal bone loss through radiographic analysis. Materials and Methods: A literature search involving 5 databases (PubMed, ScienceDirect, Scopus, Health and Medical Collection, Dentistry and Oral Sciences) was carried out. A specific combination of keywords was used to obtain the articles. The PRISMA guidelines were used to filter eligible articles. The study design, sample size, type of AI software, and the results of each eligible study were analyzed. The CASP diagnostic study checklist was used to evaluate the evidence strength score. Results: Seven articles were eligible for review according to the PRISMA guidelines. Out of the 7 eligible studies, 4 had strong CASP evidence strength scores (7-8/9). The remaining studies had intermediate CASP evidence strength scores (3.5-6.5/9). The highest area under the curve among the reported studies was 94%, the highest F1 score was 91%, and the highest specificity and sensitivity were 98.1% and 94%, respectively. Conclusion: AI-based detection of periodontal bone loss using radiographs is an efficient method. However, more clinical studies need to be conducted before this method is introduced into routine dental practice.

$^{17}O$ NMR Study On Water Excharge Rate of Paramagnetic Contrast Agents ($^{17}O$ NMR 기법을 이용한 상자성 자기공명조영제의 물분자 교환에 관한 연구)

  • Yongmin Chang;Sung Wook Hong;Moon Jung Hwang;Il Soo Rhee;Duk-Sik Kang
    • Investigative Magnetic Resonance Imaging
    • /
    • v.5 no.1
    • /
    • pp.33-37
    • /
    • 2001
  • Purpose : The water exchange rate between bulk water and bound water is an important parameter in deciding the efficiency of paramagnetic contrast agents. In this study, we evaluated the water exchange rates of various Gd-chelates using oxygen-17 NMR technique. Material and Methods : The samples (Gd-DTPA, Gd-DTPA-BMA, Gd-DOTA, Gd-EOB-DTPA) were prepared by mixing 5% $^{17}O-enriched$ water (Isotech, USA). The pH of the samples was adjusted to physiological value [pH=7.0] by buffer solution. The variable temperature $^{17}O-NMR$ measurements were performed using Bruker-600 (14.1 T, 81.3 MHz) spectrometer. Bruker VT-1000 temperature control units were used to stabilize the temperature. The $^{17}O$ spin-spin relaxation times (T2) were measured using Carr-Purcell-Meiboom-Gill (CPMG)I pulse sequence with 24 echo trains. The variable temperature T2 relaxation data were then fitted into Solomon-Bloembergen equations using least square fit algorithm to estimate the water exchange times. Results : From the measured $^{17}O-NMR$ relaxation rates, the determined water exchange rates at 300K are $0.42{\;}{\mu}s$ for Gd-DTPA, $1.99{\;}{\mu}s$ for Gd-DTPA-BMA, $0.27{\;}{\mu}s$ for Gd-DOTA, and $0.11{\;}{\mu}s$ for Gd-EOB-DTPA. The Gd-DTPA-BMA showed slowest exchange whereas Gd-EOB-DTPA had fastest water exchange rate. In addition, it was found that the water exchange rates (${\tau}_m$) of all samples had exponential temperature dependence with different decay constant. Conclusion : $^{17}O-NMR$ relaxation rate measurements, when combined with variable temperature technique, provide a solid tool for studying water exchange rate, which is very important in investigating the detailed mechanism of relaxation enhancement effect of the paramagnetic contrast agents.

  • PDF

The Effects of Image Quality due to Scattering X-ray according to increasing Patient Thickness (피사체 두께에 따른 산란선 발생이 화질에 미치는 영향)

  • Park, Ji-Koon;Yang, Sung-Woo;Jun, Jae-Hoon;Cho, Su-Yeon;Kim, Kyo-Tae;Heo, Ye-Ji;Kang, Sang-Sik
    • Journal of the Korean Society of Radiology
    • /
    • v.11 no.7
    • /
    • pp.671-677
    • /
    • 2017
  • In this study, scattering factors affecting the quality of medical images were quantitatively analyzed and investigated. MCNPX simulation was conducted by using ANSI phantom, made of tissue equivalent materials, to calculate the scattering ratio occurred by the increase of the object thickness. Then, the result of the simulation was compared with the result of actual radiation measurement. In addition, we evaluated the image quality by the RMS evaluation, RSD and NPS analysis using X-ray images acquired with increasing object thickness. Furthermore, the scattering ratio was analyzed by increasing the thickness of acrylic phantom on chest phantom. The result showed that the scattering ratio was increased to 57.2%, 62.4%, and 66.8% from 48.9%, respectively, when the acrylic phantom thickness was increased by 1 inch from 6.1 inches. The results of MCNPX simulation and the actual measured scattering dose showed similar results. Also, as a result of RMS measurement from acquired x-ray images, the standard deviation decreased as the object thickness increased. However, in the RSD analysis considering the average incident dose, the results were increased from 0.028 to 0.039, 0.051, 0.062 as the acrylic phantom thickness was increased from 6.1 inches to 7.1 inch, 8.1 inch, and 9.1 inch, respectively. It can be seen that the increase of the scattering effect due to the increase of the object thickness reduces the SNR. Also, the NPS results obtained by measuring scattered radiation incident on the detector resulted in the increase of the noise as the object thickness increased.