• Title/Summary/Keyword: Radiology science department

Search Result 2,933, Processing Time 0.027 seconds

Low serum 25-hydroxyvitamin D levels, tooth loss, and the prevalence of severe periodontitis in Koreans aged 50 years and older

  • Kim, Hyunju;Shin, Min-Ho;Yoon, Suk-Ja;Kweon, Sun-Seog;Lee, Young-Hoon;Choi, Chang-Kyun;Kim, OkJoon;Kim, Young-Joon;Chung, HyunJu;Kim, Ok-Su
    • Journal of Periodontal and Implant Science
    • /
    • v.50 no.6
    • /
    • pp.368-378
    • /
    • 2020
  • Purpose: Vitamin D deficiency may cause bone loss and increased inflammation, which are well-known symptoms of periodontal disease. This study investigated whether serum 25-hydroxyvitamin D (25(OH)D) levels are associated with periodontal disease status and tooth loss. Methods: Cross-sectional data from 5,405 individuals aged ≥50 years (2,253 males and 3,152 females) were obtained from the 2008-2010 Dong-gu study, a prospective cohort study of risk factors for chronic diseases. Periodontal examinations were conducted to evaluate the number of remaining teeth, the periodontal probing depth (PPD), the clinical attachment level (CAL), and bleeding on probing. The percentages of sites with PPD ≥4 mm and CAL ≥4 mm were recorded for each participant. The severity of periodontitis was classified using the Centers for Disease Control and Prevention and the American Academy of Periodontology case definitions. Serum 25(OH)D levels were classified as reflecting severe deficiency, deficiency, insufficiency, or sufficiency. Multivariate linear regression analysis was performed to assess the associations of serum 25(OH)D levels with periodontal parameters and the number of remaining teeth after adjusting for confounders including age, smoking status, alcohol consumption status, month of blood collection, and physical activity. Multivariate logistic regression was used to evaluate the association between serum vitamin D levels and severe periodontitis. An overall statistical analysis and a stratified analysis by sex were performed. Results: Overall, the rates of severe deficiency, deficiency, insufficiency, and sufficiency were 6.5%, 67.9%, 22.4%, and 3.2%, respectively. After adjustment for confounders, vitamin D levels were directly associated with the number of remaining teeth, an association that was significant in males, but not in females. Sufficient serum 25(OH)D was associated with a low frequency of severe periodontitis. Conclusions: This population-based cross-sectional study indicates that low serum 25(OH) D is significantly associated with tooth loss and severe periodontitis in Koreans aged 50 years and older.

A clinical pilot study of jawbone mineral density measured by the newly developed dual-energy cone-beam computed tomography method compared to calibrated multislice computed tomography

  • Kim, Hyun Jeong;Kim, Ji Eun;Choo, Jiyeon;Min, Jeonghee;Chang, Sungho;Lee, Sang Chul;Pyun, Woong Beom;Seo, Kwang-Suk;Karm, Myong-Hwan;Koo, Ki-Tae;Rhyu, In-Chul;Myoung, Hoon;Heo, Min-Suk
    • Imaging Science in Dentistry
    • /
    • v.49 no.4
    • /
    • pp.295-299
    • /
    • 2019
  • Purpose: This clinical pilot study was performed to determine the effectiveness of dual-energy cone-beam computed tomography (DE-CBCT) in measuring bone mineral density (BMD). Materials and Methods: The BMD values obtained using DE-CBCT were compared to those obtained using calibrated multislice computed tomography (MSCT). After BMD calibration with specially designed phantoms, both DE-CBCT and MSCT scanning were performed in 15 adult dental patients. Three-dimensional (3D) Digital Imaging and Communications in Medicine data were imported into a dental software program, and the defined regions of interest (ROIs) on the 3-dimensional surface-rendered images were identified. The automatically-measured BMD values of the ROIs (g/㎤), the differences in the measured BMD values of the matched ROIs obtained by DE-CBCT and MSCT 3D images, and the correlation between the BMD values obtained by the 2 devices were statistically analyzed. Results: The mean BMD values of the ROIs for the 15 patients as assessed using DE-CBCT and MSCT were 1.09±0.07 g/㎤ and 1.13±0.08 g/㎤, respectively. The mean of the differences between the BMD values of the matched ROIs as assessed using DE-CBCT and calibrated MSCT images was 0.04±0.02 g/㎤. The Pearson correlation coefficient between the BMD values of DE-CBCT and MSCT images was 0.982 (r=0.982, P<0.001). Conclusion: The newly developed DE-CBCT technique could be used to measure jaw BMD in dentistry and may soon replace MSCT, which is expensive and requires special facilities.

The Study of Incidence Disease Categories on Breast Medical Examination in Some Area (일부지역 유방검사의 질환별 발생 빈도에 관한 연구)

  • Kwak, Byung-Joon;Im, In-Chul;Ji, Tae-Jeong
    • Journal of radiological science and technology
    • /
    • v.30 no.4
    • /
    • pp.357-363
    • /
    • 2007
  • The breast cancer occurrence have been increase yearly. Consequently the effort for early discovery or prevention is necessary. The study investigated the age distribution rate and a disease distribution occurrence rate in the breast medical examination of Ulsan city area. Breast medical examination distribution ratio it preferred the breast ultrasound with mamography 38.8% breast-ultrasonogrphy 61.2% to be investigated. The disease categories distribution was various from breast-ultrasound medical examination and it was investigated with becomes ramification. The reading find was many most infiltrating duct carcinoma from 40 age stage. The ductal carcinoma in situ was many from 50 age stage. The most many disease was investigated HP(Heterogenous dense nodule or mass parenchyma pattern) with 29.2%. Also the breast abscess or mastitis disease is confirmed only the breast-ultrasonography examination, even from the outside disease it was investigated with the fact that the breast-ultrasound raises the discrimination.

  • PDF

Evaluation of Washing Method for Sterilization of Gel Container for Ultrasound Inspection (초음파검사용 젤 용기의 제균을 위한 세척방법 평가)

  • Lee, Hee-Jeong;Lee, Suk-Jun;Seoung, Youl-Hun
    • Journal of radiological science and technology
    • /
    • v.41 no.3
    • /
    • pp.241-247
    • /
    • 2018
  • The purpose of this study was to compare the ultrasound gel container washing methods for the sterilization of contaminants and to find the useful methods for the prevention of infection caused by the ultrasonic gel containers. In this experiment, a 250 mL ultrasonic gel container was used, and the ultrasonic gel used was a non-sterile gel (ECO GEL 99, SeungWon Medical, Korea). In order to evaluate the degree of contamination, new 250 mL 15 containers were divided into 5 groups to perform five types of washing by no treatment, washing with water, washing with soap, washing with bottle cleaner and high disinfection level washing. After the washing process, filled the gel container with gel and after 2 weeks, the number of colonies in the gel container was sampled repeatedly twice in the same ultrasonic laboratory and compared before and after washing. As a result of among the five cleaning methods used in this study, 87.2% and 88.9% of the soapy water washing (p = 0.028) and high level washing (p = 0.027) showed significant bacterial reduction rates, respectively. Our findings conclusively an ultrasonic gel container cleaning method for removing contaminants has been found to be an effective sterilization method at a low cost with a soapy water cleaning method. Therefore, it is expected that it will be helpful to prevent the infection caused by the ultrasonic gel container by suggesting the sterilization cleaning method that is practically useful in this study.

The Relationship Between Epicardial Adipose Tissue and Diabetes Mellitus (심장외막지방두께와 당뇨와의 연관성 연구)

  • Kim, Sun-Hwa;Kim, Jung-Hoon;Im, In-Chul
    • Journal of radiological science and technology
    • /
    • v.41 no.4
    • /
    • pp.305-312
    • /
    • 2018
  • The incidence of cardiovascular disease increases rapidly after 40's. The thickness of the epicardial adipose tissue was measured to analyze the risk factors affecting the thickness change. We present the cut off value for the epicardial adipose tissue thickness for high impacted variables. For the study, 547 patients underwent echocardiography, epicardial adipose tissue thickness, body mass index, abdominal subcutaneous fat thickness and diabetes mellitus were used as analytical variables. As a result, multiple regression analysis of age group showed that diabetes mellitus was highly influential in all age group, so we could predict the cut off value for the epicardial adipose tissue thickness for diabetes mellitus. As a result of ROC curve analysis, cut off value of 7.44 mm was obtained with sensitivity of 79.6% and specificity of 60.6% for diab etes variab le. Logistic regression analysis b ased on this value showed that the risk for diab etes increased 6 times with each increase in the thickness of the epicardial adipose tissue. Among the various obesity indexes, epicardial adipose tissue is used as an important index especially to prevent the risk of cardiovascular disease. Therefore, we suggest that the use of echocardiography as a routine screening method for the prevention of cardiovascular disease and metabolic syndrome, which is rapidly increasing in patients over 40's age, will enable more effective monitoring. Radiation is the emission or transmission of energy in the form of waves or particles through space or through a material medium.

Accuracy and reliability of stitched cone-beam computed tomography images

  • Egbert, Nicholas;Cagna, David R.;Ahuja, Swati;Wicks, Russell A.
    • Imaging Science in Dentistry
    • /
    • v.45 no.1
    • /
    • pp.41-47
    • /
    • 2015
  • Purpose: This study was performed to evaluate the linear distance accuracy and reliability of stitched small field of view (FOV) cone-beam computed tomography (CBCT) reconstructed images for the fabrication of implant surgical guides. Material and Methods: Three gutta percha points were fixed on the inferior border of a cadaveric mandible to serve as control reference points. Ten additional gutta percha points, representing fiduciary markers, were scattered on the buccal and lingual cortices at the level of the proposed complete denture flange. A digital caliper was used to measure the distance between the reference points and fiduciary markers, which represented the anatomic linear dimension. The mandible was scanned using small FOV CBCT, and the images were then reconstructed and stitched using the manufacturer's imaging software. The same measurements were then taken with the CBCT software. Results: The anatomic linear dimension measurements and stitched small FOV CBCT measurements were statistically evaluated for linear accuracy. The mean difference between the anatomic linear dimension measurements and the stitched small FOV CBCT measurements was found to be 0.34 mm with a 95% confidence interval of +0.24 - +0.44 mm and a mean standard deviation of 0.30 mm. The difference between the control and the stitched small FOV CBCT measurements was insignificant within the parameters defined by this study. Conclusion: The proven accuracy of stitched small FOV CBCT data sets may allow image-guided fabrication of implant surgical stents from such data sets.

Evaluation of the Patient Dose in Case of Standard Radiographic Examinations Using CR and DR (표준영상의학검사를 대상으로 한 CR과 DR에서의 환자선량평가)

  • Kim, Sang-Tae;Han, Beom-Hui
    • Journal of radiological science and technology
    • /
    • v.33 no.3
    • /
    • pp.173-178
    • /
    • 2010
  • In projection radiography, two types of digital imaging systems are currently available, computed radiography (CR) and digital radiography (DR): a difference between them can be stated in terms of dose and image quality. In the Department of Radiology our hospital, a flat-panel DR equipment (Digital diagnost, Philips) and two CR systems (ADC Compact plus digitizer, AGFA) are employed. Eight standard radiographic examinations (Skull AP, Skull LAT, Chest PA, Chest LAT, Abdomen AP, L-spine AP, L-spine LAT, Pelvis AP) were considered: doses delivered to patients in terms of both entrance skin dose (ESD) were calculated and compared in order to study the dosimetric discrepancies between CR and DR. Assessment of image quality is undertaken by Consultant Radiologists to ensure that the quality criteria for diagnostic radiographic images of the European guidelines were met. Results showed that both ESD in DR are lower than that in CR; all images met the criteria in the European Guidelines for both modalities and were used for reporting by the radiologists. Since the operators are the same and the image quality is comparable in both modalities, this study shows that in the considered examinations, DR can perform better than CR from a dosimetric point of view.

The Evaluation of Image Quality According to the Change of Reconstruction Algorithm of CT Images (재구성 알고리즘 변화에 따른 CT 영상의 화질 평가)

  • Han, Dong-Kyoon;Park, Kun-Jin;Ko, Shin-Kwan
    • Korean Journal of Digital Imaging in Medicine
    • /
    • v.12 no.2
    • /
    • pp.127-132
    • /
    • 2010
  • In this study, the correlation among the changes of Modulation Transfer Function(MTF) in the noise and high-contrast resolution and the change of Contrast to noise ratio(CNR) in the low-contrast resolution will be examined to investigate the estimation of image quality according to the type of algorithms. The image data obtained by scanning American Association of Physicists in Medicine(AAPM) phantom was applied to each algorithm and the exposure condition of 120 kVp, 250 mAs, and then the CT number and noise were measured. The MTF curved line of the high-contrast resolution was calculated with Point Spread Function(PSF) by using the analysis program by Philips, resulting in 0.5 MTF, 0.1 MTF and 0.02 MTF respectively. The low-contrast resolution was calculated with CNR and the uniformity was measured to each algorithm. Since the measurement value for the uniformity of the equipment was below ${\pm}$ 5 HU, which is the criterion figure, it was found to belong to the normal range. As the algorithm got closer from soft to edge, the standard deviation of CT number increased, which indicates that the noise increased as well. As for MTF, 0.5 MTF, 0.1 MTF and 0.02 MTF were all sharp algorithms, and as the algorithm got closer from soft to edge, it was possible to distinguish more clearly with the naked eye. On the other hand, CNR gradually decreased, because the difference between the contrast hole CT number and the acrylic CT number was the same while the noise of hole increased.

  • PDF

Dose Assessment in Accordance with the Measured Position of Size Specific Dose Estimates (Size Specific Dose Estimates(SSDE)측정 위치에 따른 피폭선량 평가)

  • Kim, Jung-Su;Hong, Sung-Wan;Kim, Jung-Min
    • Journal of radiological science and technology
    • /
    • v.38 no.4
    • /
    • pp.383-387
    • /
    • 2015
  • This study investigated the size specific dose estimates of difference localizer on pediatric CT image. Seventy one cases of pediatric abdomen-pelvic CT (M:F=36:35) were included in this study. Anterior-posterior and lateral diameters were measured in axial CT images. Conversion factors from American Association of Physicists in Medicine (AAPM) report 204 were obtained for effective diameter to determine size specific dose estimate (SSDE) from the CT dose index volume (CTDIvol) recorded from the dose reports. For the localizer of mid-slice SSDE was 107.63% higher than CTDIvol and that of xiphoid-process slices SSDE was higher than 92.91%. The maximum error of iliac crest slices, xiphoid process slices and femur head slices between mid-slices were 7.48%, 17.81% and 14.04%. In conclusion, despite the SSDE of difference localizer has large number of errors, SSDE should be regarded as the primary evaluation tool of the patient radiation in pediatric CT for evaluation.

Quantitative assessment of periimplant bone density (HU) on CBCT image (CBCT 영상에서 무치악부 임프란트 매식체 주위골 골밀도(HU)의 정량적 평가)

  • Goo, Jong-Gook;Kim, Jin-Soo;Kim, Jae-Duk
    • Imaging Science in Dentistry
    • /
    • v.38 no.1
    • /
    • pp.1-5
    • /
    • 2008
  • Purpose: The primary aims of this retrospective study were to compare subjective bone quality and bone quality based on the Hounsfield scale in different segments of the edentulous jaw, and to establish quantitative and objective assessment of the bone quality. Materials and Methods: Twenty eight randomly selected cone-beam computed tomographic (CBCT) scans were analyzed. For evaluation one hundred and twelve edentulous areas were selected. Implant recipient sites were evaluated visually for Lekholm and Zarb classification. The same sites were subsequently evaluated digitally using the Hounsfield scale with Vimplant$2.0^{TM}$, and the results were correlated with visual classification. Data was subject for statistical analysis in order to determine correlation between recorded HU and the regions of the mouth with the Kruskal-Wallis test. Results: The highest unit/mean density value (311 HU) was found in the anterior mandible, followed by 259 HU for the posterior mandible, 216 HU for the anterior maxilla, and 127 HU for the posterior maxilla. These results demonstrate a strong correlation for HU depending on the region of the mouth (p<0.001). The relationship between HU and type 4 bone was found to be significant (r=0.74). Conclusion: Knowledge of the Hounsfield value as a quantitative measurement of bone density can be helpful as a diagnostic tool by using $CBMercuRa6^{TM}$ with $Vimplant^{TM}$ software.

  • PDF