• 제목/요약/키워드: Radiology science department

Search Result 2,933, Processing Time 0.029 seconds

Estimation of Appropriate Number of Radiologic Technologist Based on Analysis of Time Required for Computed Tomography (전산화단층촬영의 소요시간 분석에 기반한 방사선사의 적정인력 산정에 관한 연구)

  • Lee, Ki-Baek;Kim, Yung-Kyoon;Kim, Eun-Hye;Kim, Yon-Min
    • Journal of radiological science and technology
    • /
    • v.45 no.3
    • /
    • pp.213-223
    • /
    • 2022
  • Although the number of computed tomography(CT) is increasing every year, it is insufficient to establish appropriate workload calculation standards of radiologic technologist to provide optimal medical services to patients, such as patient safety management and infection management. The purpose of this study is to present guidelines for calculating the appropriate workload of radiologic technologist by analyzing the work flow of CT procedures and the time required for CT examination in major hospitals. As for the study subjects and methods, the appropriate process for each step of CT examination was investigated to systematically present the process and time required for the actual examination, and the CT procedure time of 104,105 adult patients and 465 pediatric patients under the age of 6 were analyzed. For the time required, data according to the use of contrast medium, procedure type, and adult/child were collected and compared. The test time of CT examination using contrast medium took about 13 minutes when one radiologic technologist worked and about 9 minutes when two radiologic technologists worked. The time required for the procedures were statistically significant depending on the presence or absence of contrast medium, multi-phase procedure, and patient age (considering pediatric patients). As a result, in order to thoroughly perform patient safety and infection management, the appropriate workload increased by about 40% when there were two radiologic technologists. The limit workload was an average of 32 people per day with one radiologic technologist per 15 minutes, and 48 people per day with two radiologic technologist per 10 minutes. This is a marginal workload, and in the case of procedures that require more time to acquire radiographic images, the interval between reservations should be widened.

Study on the chemical environment for conformational change of i-motif DNA by atomic force microscopy cantilever (AFM 캔틸레버를 이용한 i-motif DNA의 구조 변화에 미치는 화학적 환경에 대한 연구)

  • Jung, Hwi-Hun;Park, Jin-Sung;Yang, Jae-Moon;Lee, Sang-Woo;Eom, Kil-Ho;Kwon, Tae-Yun;Yoon, Dae-Sung
    • Journal of Sensor Science and Technology
    • /
    • v.19 no.3
    • /
    • pp.214-220
    • /
    • 2010
  • Three-dimensional(3D) structure of specific DNA can be changed between two conformations under an external environmental transition such as pH and salt concentration variations. We have experimentally observed the conformational transitions of i-motif DNA using AFM cantilever bioassay. It is shown that pH change of a solvent induces the bending defleciton change of a cantilever functionalized by i-motif DNA. This indicates that cantilever bioassay enables the label-free detection of DNA structural changes upon pH change. It is implied that cantilever bioassay can be a de novo route to quantitatively understand the conformational transitions of biological molecules under environmental changes.

Improvement of Patient Safety and Inspection Satisfaction by Developing Pretreatment Process System with the Patients Who Reserved CT Enhance Examination (CT 조영검사 예약환자의 전처치 프로세스 시스템 개발을 통한 환자안전 및 검사 만족도 향상)

  • Beom, Hyinam;Han, Jaebok;Song, Jongnam;Kim, Wook;Choi, Namgil
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.1
    • /
    • pp.29-37
    • /
    • 2016
  • This study aims to improve the satisfaction level of the patient who undergoes CT contrast examination by developing and applying pretreatment process system, which not only can reduce the side effects caused by the test but also can help carry out the test smoothly. The subjects were 214 patients who booked CT contrast examination from January 2014 to February 2014 but could not carry out their test on schedule. We analyzed the reasons for the delay and conducted follow-up survey on them. We analyzed the usefulness of pretreatment process system by contemplating and developing pretreatment process system and applying it to the patients for whom follow-up survey was conducted from January 2015 to February 2015. The number of outpatients who came to the hospital form January to February 2014 was 2,846 and the number of patients who could not undergo the test was 214, accounting for 7.52% of the total. The specific reason for the delay includes 214 cases of unknown creatinine 98 with 120 minutes of average delay time, 40 cases of creatinine over 1.3(19%) with 30minutes of average delay time, 34 cases of past contrast media side effect 6% with 40 minutes of average delay time and 25 cases of lack of pretreatment such as fasting, etc. 11% with 120minutes of average delay time. The number of CT scan has been increasing ever since the development of CT and the frequency of using the contrast media is expected to increase. If we can employ pretreatment process system in order to effectively control the side effect of contrast media and help the CT contrast examination to be smoothly conducted on schedule, I'm sure we could improve the quality of our medical service and increase our patients' satisfaction who come to our CT scan room.

Effects of skin temperature change, cold pain and muscle activity by Cold Air Application type on the induced delayed onset muscle soreness (지연성 근육통 유발 후 냉기 적용 방법이 피부온도의 변화, 냉각 통과 근육 기능에 미치는 효과)

  • Choi, Yoorim;Jung, Bongjae;Hwang, Byeongjun
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.1
    • /
    • pp.99-106
    • /
    • 2013
  • The purpose of this study was to after induced delayed onset muscle soreness, the purpose of this study is to present the effective way on skin temperature changes and cold pain for 14 subjects during to applied with only Cold-jet stream and Cold-jet stream with infra red. 14 healthy men and women who delayed onset muscle soreness eccentric contractions induced by exercise and then the biceps alone was applied to the Cold-jet stream. We measured the time that skin temperature fall from room temperature to $10^{\circ}C$(first period), the time rewarmed from $10^{\circ}C$ to $20^{\circ}C$(second period), the time fall again to $10^{\circ}C$(third period) and the time rewarmed again to $20^{\circ}C$(fourth period). Cold-jet stream with infrared combination therapy was performed with the same method. Results of this study were 1st and 2nd experimental cooling experiments in the to fall to $10^{\circ}C$ Cold-jet stream with infrared combination therapy than in the Cold-jet stream was longer(p<.05). At second period, It took longer in Cold-jet stream with infrared rewarmed than Cold-jet stream to rewarm skin(p<.05). Cold-jet stream with infrared combination therapy than Cold-jet stream had less incidence of cold pain(p<.05). Thickness of biceps brachii were found significant difference related measurment each group was consistent. In this study, Cold-jet stream with infrared combination therapy more effective than Cold-jet stream in reduced cold pain and lowering skin temperature. This work was supported by education capacity building project fund of Taegu Science University, 2012.

The Evaluation of Imaging Quality Depending the Shift of the Central Axis in FOCUS DWI Investigation (Focus DWI 검사에서 중심축 이동에 따른 화질 평가)

  • Kim, Younghwa;Jeong, Moontaeg;Choi, Namgil
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.5
    • /
    • pp.631-636
    • /
    • 2018
  • The problem that the existing the magnetic resonance image (MRI) was prone to have not only long readout duration and low bandwidth in the phase-encode direction, but also geometric distortion was pointed out. The purpose of this study is to identify the usefulness of FOCUS-DWI through comparing FOCUS-DWI with the Conventional-DWI on a degree of uniformity and artifacts caused by the distance change in the central axis within the magnetic field. In terms of artifacts, there happened irregular striped artifacts in the Conventional-DWI technique, which in particular, more often arose in the central axis. Also, the overlap of imaging drastically increased. By contrast, there were no irregular striped artifacts in the FOCUS-DWI technique. In conclusion, it was found that the FOCUS-DWI technique was superior to the Conventional-DWI technique in terms of artifacts, the overlap of imaging, and a degree of uniformity. In addition, there was no difference of the change in distance from the central axis between the FOCUS-DWI technique and the Conventional-DWI technique. Thus, it is considered the FOCUS-DWI technique having less imaging distortion and high image quality will be highly clinically used.

Denoising of Digital Mammography Images Using Wavelet Transform (웨이블릿을 이용한 디지털유방영상의 노이즈 제거)

  • Choi, Seokyoon;Ko, Seongjin;Kang, Sesik
    • Journal of the Korean Society of Radiology
    • /
    • v.7 no.3
    • /
    • pp.181-189
    • /
    • 2013
  • The optimum exposure parameters are found when examined using the automatic mode in FFDM. improve the image quality by applying denoising algorithm and propose methods to reduce AGD(Average Grandular Dose) a patient can receive. For the experiment, Nuclear Associates Model 18-222 phantom was the used, and the entrance dose and AGD were measured. And then, Signal, Noise, SNR and FOM(Figure of Merit) were measured, compared and analyzed image denoising before and after. As the experiment result, first, SNR was the highest at Mo/Mo 23kVp and W/Rh 35kvp was the lowest for the average glandular dose. It showed to use 28kVp of W/Rh to be the best through the result of FOM. SNR was the highest at Mo/Mo 23kVp(image denoising), and it showed to W/Rh and 28kVp to be the best in the FOM result which AGD was considered at the same time. By the image denoising, it is possible to reduce noise while maintain important information in the image.

Effects of Cervical Joint Mobilization on the Forward Head Posture and Neck Disability Indexes (경부관절가동술이 두부전방자세와 경부장애지수에 미치는 영향)

  • Oh, Hyunju;Hwang, Byeongjun;Choi, Yoorim
    • Journal of the Korean Society of Radiology
    • /
    • v.8 no.2
    • /
    • pp.89-96
    • /
    • 2014
  • This paper tries to examine whether the application of joint mobilization to subjects who have the forward head posture due to malalignment in the cervical joint has influence on posture changes and functions in the cervical joint. The subjects were 39 students from G University in Gyeongsangbuk-do. The cervical joint mobilization was applied to 20 subjects and not to 19. The students with a cervical lordosis angle of $21^{\circ}C$ or less, an anterior weight bearing (AWB) of 15mm or greater, and a cervical extension ROM of $70^{\circ}C$ or less in terms of radiography were selected as subjects under their voluntary agreement. The patients actively performed the joint mobilization slowly 8 times per session while therapists continuously applied sustained accessory glide to their painful joints 3 times per week for 4 weeks along with the cervical expansion and flexion in SNAGS among other Mulligan's (1995) techniques. The measurement was carried out in terms of radiographic inspection and neck disability indexes. As a result of the experiment, it turned out that the subjects with the forward head posture had changes in the cervical AWB and ARA, the ranges of expansion and flexion, and the NDI(Neck Disability Index) after the intervention for the experimental group by applying cervical joint mobilization. There were no changes observed in the control group. In conclusion, the application of joint mobilization turned out to have influence on the improvement of cervical joint postures, and craniocervical region functions.

Analysis of Counting Rate according to Presence or Absence of Detector's Protector in Beta-rays Measurement using Geiger-Muller Counter (Geiger-Muller 계수관을 이용한 베타선측정에서 디텍터 보호유무에 따른 계수율 분석)

  • Jang, Ji-Yong;Jeong, Moon-Taeg;Song, Jong-Nam;Ha, Jae-Jun;Han, Jae-Bok
    • Journal of the Korean Society of Radiology
    • /
    • v.12 no.1
    • /
    • pp.31-37
    • /
    • 2018
  • In the surface contamination test using the end-window Geiger-Muller type counter, the wrap is used as a method for protecting the detector exposed to the outside in order to measure the beta-rays. We analyze the effect of this method on the measurement rate and the correction factor, and wanted to make it clear to radiation workers that excessive use of the wrap can affect the measured value of the beta-rays. The experimental method was to compare and analyze the change of the beta-rays measurement counting rate and the calibration factor according to the wrap thickness using the beta-rays with different energy of 3 KBq, 1.5 KBq and 0.3 KBq. The subjects of this study were the end-window Geiger-Muller type counter which were held at the calibration center certified by Korea Laboratory Accreditation Scheme (KOLAS) in March 2012, Cl-36 (Chlorine) and Sr-90 (Strontium) were used as the source of beta radiation. The measurement counting rate decreased with increasing wrap thickness, and the calibration factor increased with increasing wrap thickness. Since the changes of the measurement counting rate and the calibration factors can reduce the accuracy of the instrument readings, but also have a significant impact on detector contamination and damage, so there is a need to find out what thickness of wrap is most effective. If we using a wraps with thickness that show a low rate of change of the measurement counting rate and the calibration factor, it will protect the detector and minimize the effect on the measured value of the beta-rays.

Evaluation of Quantitative Image Quality using Frequency and Parameters in the Ultrasound Image (초음파영상에서 주파수와 파라미터를 이용한 정량적 영상평가)

  • Kim, Changsoo;Kang, Se Sik;Kim, Junghoon
    • Journal of the Korean Society of Radiology
    • /
    • v.10 no.4
    • /
    • pp.247-253
    • /
    • 2016
  • Ultrasound devices diagnose many disease, which is widely used, can not be standardized quantitative evaluated in order to evaluate sonography image of quality. Therefore, in this papers, aims to get correct image in order to accurate diagnosis by figuring out the appropriate parameter based on each target by measuring distortion which results in the analyzation of the sensitivity of SNR and the histogram of signal by manipulating parameter of 8 mm target in ATS-539 multipurpose phantom. Equipment using Acuson sequoia 512, convex probe and utilizes multi-objective phantom. experiment method is that first you put the phantom on the flat and acquire 85 sheets of image, changing frequency(2,3,4 MHz, harmonic 3, 4, 4.5 MHz), Focus(2, 4, 6 unit), and Dynamic Range(58, 68, 78, 88, 98) for a 8 mm structure. through the Image J program. The sensitivity angle of 8mm target through Image J program is gauged by each separate target SNR and the distorted angle subtract and measure Histogram of background from Histogram of signal and take top 40% from the given result value above. According to parameter variation we found out proper parameter by acquiring SNR of sensitivity and distortion data for aspect of transition. The more this findings have Focus, the lower distortion value and at 4 MHz frequency this result have high SNR and low distortion value. Dynamic Range got an appropriate image on 88 and 98. It is considered on the basis of the experimental data, the probability of disease diagnosis will get higher.